3,264 534 14MB
Pages 380 Page size 396 x 612 pts Year 2001
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK
The Mechanical Engineering Handbook Series Series Editor
Frank Kreith Consulting Engineer
Published Titles Handbook of Heating, Ventilation, and Air Conditioning Jan F. Kreider Computational Intelligence in Manufacturing Handbook Jun Wang and Andrew Kusiak The CRC Handbook of Mechanical Engineering Frank Kreith The CRC Handbook of Thermal Engineering Frank Kreith The Handbook of Fluid Dynamics Richard W. Johnson Hazardous and Radioactive Waste Treatment Technologies Handbook Chang Ho Oh The MEMS Handbook Mohamed Gad-el-Hak Air Pollution Control Technology Handbook Karl B. Schnelle, Jr. and Charles A. Brown
Forthcoming Titles Biomedical Technology and Devices Handbook James Moore and George Zouridakis Fuel Cell Technology Handbook Gregor Hoogers Handbook of Mechanical Engineering, Second Edition Frank Kreith and Massimo Capobianchi Handbook of Non-Destructive Testing and Evaluation Engineering James Tulenko and David Hintenlang Inverse Engineering Handbook Keith A. Woodbury Opto-Mechatronic Systems Handbook: Techniques and Applications Hyung Suck Cho, Toshio Fukuda, and George Barbastathis
© 2002 by CRC Press LLC
AIR POLLUTION CONTROL TECHNOLOGY HANDBOOK Authored by
Karl B. Schnelle, Jr., Ph.D., P.E. Vanderbilt University Nashville, Tennessee
Charles A. Brown, P.E. VECO Pacific, Inc. Bellingham, Washington
CRC PR E S S Boca Raton London New York Washington, D.C.
9588 fm frame Page 4 Wednesday, September 5, 2001 9:38 PM
Library of Congress Cataloging-in-Publication Data Schnelle, Karl B. Air pollution control technology handbook / Karl B. Schnelle, Jr. and Charles A. Brown. p. cm. -- (Mechanical engineering handbook series) Includes bibliographical references and index. ISBN 0-8493-9588-7 (alk. paper) 1. Air--Pollution--Handbooks, manuals, etc. 2. Air--Purification--Equipment and supplies--Handbooks, manuals, etc. I. Brown, Charles A. (Charles Arnold), 1951- II. Title. III. Series. TD883 .S283 2001 628.5′3--dc21
2001037498
This book contains information obtained from authentic and highly regarded sources. Reprinted material is quoted with permission, and sources are indicated. A wide variety of references are listed. Reasonable efforts have been made to publish reliable data and information, but the author and the publisher cannot assume responsibility for the validity of all materials or for the consequences of their use. Neither this book nor any part may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, microfilming, and recording, or by any information storage or retrieval system, without prior permission in writing from the publisher. The consent of CRC Press LLC does not extend to copying for general distribution, for promotion, for creating new works, or for resale. Specific permission must be obtained in writing from CRC Press LLC for such copying. Direct all inquiries to CRC Press LLC, 2000 N.W. Corporate Blvd., Boca Raton, Florida 33431. Trademark Notice: Product or corporate names may be trademarks or registered trademarks, and are used only for identification and explanation, without intent to infringe.
Visit the CRC Press Web site at www.crcpress.com © 2002 by CRC Press LLC No claim to original U.S. Government works International Standard Book Number 0-8493-9588-7 Library of Congress Card Number 2001037498 Printed in the United States of America 1 2 3 4 5 6 7 8 9 0 Printed on acid-free paper
9588 fm frame Page 5 Wednesday, September 5, 2001 9:38 PM
Dedication The authors would like to dedicate this book to all the students who have been in their air pollution control courses at Vanderbilt University, Western Washington University, Gonzaga University, and Education Services of the American Institute of Chemical Engineers. We appreciate your attendance, your attentiveness, and your desire to improve our environment.
© 2002 by CRC Press LLC
9588 fm frame Page 6 Wednesday, September 5, 2001 9:38 PM
Preface DESIGN YIELDS NEW ACTION MOST IDEAL TO ENVIRONMENT This book is written to serve as a reference handbook for the practicing engineer or scientist who needs to prepare the basic process engineering and cost estimation required for the design of an air pollution control system. The user of this book should have a fundamental understanding of the factors resulting in air pollution and a general knowledge of the techniques used for air pollution control. The topics presented in this handbook are covered in sufficient depth so that the user can proceed with the basic equipment design using the methods and design equations presented. Although moving sources, especially those powered by internal combustion engines, are serious contributors to the air pollution problem, this book will focus on stationary sources. Furthermore, this handbook will not consider nuclear power plants or other radioactive emissions. Therefore, the major audience for this book will be engineers and scientists in the chemical and petroleum processing industry and steam power plant and gas turbine industry. Using this book the air pollution control systems designer may • • • •
Begin to select techniques for control Review alternative design methods Review equipment proposals from vendors Initiate cost studies of control equipment
This book is certainly suitable for anyone with an engineering or science background who needs to get a basic introduction to air pollution control equipment design. It could also be used as a text or reference book in a continuing education program or a university classroom.
© 2002 by CRC Press LLC
9588 fm frame Page 7 Wednesday, September 5, 2001 9:38 PM
Acknowledgments Professor Schnelle wishes to acknowledge the assistance of his former student Dr. Partha Dey and his wife Anita Dey as well as his current student Atip Laungphairojana for the preparation of 70 drawings which are part of the chapters he wrote. There would have been no book without their help. Furthermore, Professor Schnelle is forever grateful to his wife Mary Dabney Schnelle who read every word he wrote including the equations. She helped remove many errors of grammar and spelling and corrected errors of algebra and definition that the author did not find. Mr. Brown would like to acknowledge the assistance of Dr. Michael Durham, Dr. Jean Bustard, and Ms. Lynn McGuire for their review and suggestions for content of selected chapters. Also, he truly appreciates the software application support provided by his wife Susan Brown, and is eternally thankful for her loving encouragement, patience, and support while writing this book and during all of his professional endeavors.
© 2002 by CRC Press LLC
9588 fm frame Page 8 Wednesday, September 5, 2001 9:38 PM
Authors Karl B. Schnelle, Jr., Ph.D., P.E., is Professor of Chemical and Environmental Engineering, has been a member of the Vanderbilt University Faculty for more than 40 years. He has served as Chair of the Environmental and Water Resources Engineering Program and the Chemical Engineering Department for a total of 14 years. He has extensive publications in the chemical engineering and environmental area. Dr. Schnelle is an emeritus member of both the American Institute of Chemical Engineers and the Air and Waste Management Association. He is a Fellow of the American Institute of Chemical Engineers and a Diplomate of the American Academy of Environmental Engineers. He has been a lecturer in the American Institute of Chemical Engineers continuing education program for more than 30 years, where he has taught the Designing Air Pollution Control Systems and the Atmospheric Dispersion Modeling courses. Dr. Schnelle is a licensed Professional Engineer in the State of Tennessee. He has been an environmental consultant to the World Health Organization, the Environmental Protection Agency, the U.S. State Department, and the state of Tennessee and Nashville Air Pollution Control Agencies as well as to numerous private corporations. He has served two terms as a member of the Air Pollution Control Board of the state of Tennessee and continues teaching full time at Vanderbilt University. Charles A. Brown, P.E., is a Principal Staff Process Engineer with VECO Pacific, Inc., in Bellingham, WA, where he is responsible for air pollution control process design and air permitting projects for various clients. Also, he is an instructor for the short course on Designing Air Pollution Control Equipment for the American Institute of Chemical Engineers and an instructor for the course in Air Quality at Western Washington University’s Huxley College. He is a member of the American Institute of Chemical Engineers, where he served as Director of the Environmental Division, and of the Air and Waste Management Association. Mr. Brown is a licensed Professional Engineer in Washington, California, and North Dakota. He has more than 26 years of experience in a variety of industries, and has authored several articles and papers related to chemical engineering and air pollution controls.
© 2002 by CRC Press LLC
9588 fm frame Page 9 Wednesday, September 5, 2001 9:38 PM
Contents Chapter 1
A Historical Overview of the Development of Clean Air Regulations
1.1 1.2 1.3 1.4
A Brief History of the Air Pollution Problem Federal Involvement in Air Pollution Control Characterizing the Atmosphere Recipe for an Air Pollution Problem 1.4.1 Sources of Air Pollution 1.4.2 Meteorological Parameters Affecting Transport of Pollutants 1.4.3 The Effects of Air Pollution — A Comparison of London Fog and Los Angeles Smog Refereances
Chapter 2 2.1
2.2
Clean Air Act
History of the Clean Air Act 2.1.1 1970 Clean Air Act Amendments 2.1.1.1 National Ambient Air Quality Standards 2.1.1.2 New Source Performance Standards 2.1.1.3 Hazardous Air Pollutants 2.1.1.4 Citizen Suits 2.1.2 1977 Clean Air Act Amendments 2.1.2.1 Prevention of Significant Deterioration 2.1.2.2 Offsets in Non-Attainment Areas 1990 Clean Air Act Amendments 2.2.1 Title I: Provisions for Attainment and Maintenance of National Ambient Air Quality Standards 2.2.1.1 NAAQS Revisions 2.2.2 Title II: Mobile Sources 2.2.3 Title III: Hazardous Air Pollutant Program 2.2.3.1 Source Categories 2.2.3.2 Establishing MACT Standards 2.2.3.3 Risk Management Plans 2.2.4 Title IV: Acid Deposition Control 2.2.5 Title V: Operating Permits 2.2.6 Title VI: Stratospheric Ozone Protection 2.2.7 Title VII: Enforcement 2.2.8 Title VIII: Miscellaneous Provisions 2.2.9 Title IX: Research
© 2002 by CRC Press LLC
9588 fm frame Page 10 Wednesday, September 5, 2001 9:38 PM
2.2.10 Title X: Disadvantaged Business 2.2.11 Title XI: Employment Transition Assistance References Chapter 3
Air Permits for New Source
3.1
Elements of a Permit Application 3.1.1 Applicability 3.1.1.1 Potential to Emit 3.1.1.2 Fugitive Emissions 3.1.1.3 Secondary Emissions 3.1.2 Significant Emission Rates 3.1.3 Modification 3.1.4 Emissions Netting 3.1.4.1 Netting Example 3.2 Best Available Control Technology 3.2.1 Step 1: Identify Control Technologies 3.2.2 Step 2: Eliminate Technically Infeasible Options 3.2.3 Step 3: Rank Remaining Options by Control Effectiveness 3.2.4 Step 4: Evaluate Control Technologies in Order of Control Effectiveness 3.2.4.1 Energy Impacts 3.2.4.2 Environmental Impacts 3.2.4.3 Economic Impacts and Cost Effectiveness 3.2.5 Step 5: Select BACT 3.3 Air Quality Analysis 3.3.1 Preliminary Analysis 3.3.2 Full Analysis 3.4 NSR Reform References Chapter 4 4.1
4.2 4.3
Atmospheric Diffusion Modeling for PSD Permit Regulations
Introduction — Meteorological Background 4.1.1 Inversions 4.1.1.1 Surface or Radiation Inversions 4.1.1.2 Evaporation Inversion 4.1.1.3 Advection Inversion 4.1.1.4 Subsidence Inversion 4.1.2 The Diurnal Cycle 4.1.3 Principal Smoke-Plume Models The Tall Stack Classifying Sources by Method of Emission 4.3.1 A Definition of Tall Stacks 4.3.2 Process Stacks
© 2002 by CRC Press LLC
9588 fm frame Page 11 Wednesday, September 5, 2001 9:38 PM
4.4
Atmospheric-Diffusion Models 4.4.1 Other Uses of Atmospheric-Diffusion Models 4.5 EPA Computer Programs for Regulation of Industry 4.5.1 The Industrial Source Complex Model 4.5.2 Screening Models 4.5.3 The New Models 4.6 The Source–Transport–Receptor Problem 4.6.1 The Source 4.6.2 Transport 4.6.2.1 The Effective Emission Height 4.6.2.2 Bulk Transport of the Pollutants 4.6.2.3 Dispersion of the Pollutants 4.6.3 The Receptor References
Chapter 5
Source Testing
5.1 5.2 5.3
Introduction Code of Federal Regulations Representative Sampling Techniques 5.3.1 Gaseous Pollutants 5.3.2 Velocity and Particulate Traverses 5.3.3 Isokinetic Sampling References
Chapter 6 6.1 6.2 6.3
6.4 6.5 6.6 6.7 6.8
Ambient Air Quality and Continuous Emissions Monitoring
Ambient Air Quality Sampling Program Objectives of a Sampling Program Monitoring Systems 6.3.1 Fixed vs. Mobile Sampling 6.3.2 Continuous vs. Integrated Sampling 6.3.3 Selection of Instrumentation and Methods Federal Reference Methods and Continuous Monitoring The “Complete” Environmental Surveillance and Control System Typical Air Sampling Train Integrated Sampling Devices for Suspended Particulate Matter Continuous Air Quality Monitors 6.8.1 Electroconductivity Analyzer for SO2 6.8.2 Coulometric Analyzer for SO2 6.8.3 Nondispersive Infrared Method for CO 6.8.4 Flame Photometric Detection of Total Sulfur and SO2 6.8.5 Hydrocarbons by Flame Ionization 6.8.6 Fluorescent SO2 Monitor
© 2002 by CRC Press LLC
9588 fm frame Page 12 Wednesday, September 5, 2001 9:38 PM
6.8.7 6.8.8
Chemilumenescence for Detection of Ozone and Nitrogen Oxides Calibration of Continuous Monitors 6.8.8.1 Specifications for Continuous Air-Quality Monitors 6.8.8.2 Steady-State Calibrations
References
Chapter 7
Cost Estimating
7.1
Time Value of Money 7.1.1 Annualized Capital Cost 7.1.2 Escalation Factors 7.2 Types of Cost Estimates 7.3 Air Pollution Control Equipment Cost 7.3.1 OAQPS Control Cost Manual 7.3.2 Other Cost-Estimating Resources References
Chapter 8
Process Design and the Strategy of Process Design
8.1 8.2
Introduction to Process Design The Strategy of Process Design 8.2.1 Process Flowsheets 8.3 Mass and Energy Balances 8.3.1 A Mass-Balance Example 8.3.2 An Energy-Balance Example References
Chapter 9
Profitability and Engineering Economics
9.1 9.2
Introduction — Profit Goal Profitability Analysis 9.2.1 Mathematical Methods for Profitability Evaluation 9.2.2 Incremental Rate of Return on Investments as a Measure of Profitability 9.2.2.1 An Example 9.3 The Effect of Depreciation 9.3.1 An Example 9.4 Capital Investment and Total Product Cost 9.4.1 Design Development References
© 2002 by CRC Press LLC
9588 fm frame Page 13 Wednesday, September 5, 2001 9:38 PM
Chapter 10 Introduction to Control of Gaseous Pollutants 10.1 Absorption and Adsorption 10.1.1 Fluid Mechanics Terminology 10.1.2 Removal of HAP and VOC by Absorption and Adsorption Reference
Chapter 11 Absorption for HAP and VOC Control 11.1 11.2 11.3 11.4 11.5
Introduction Aqueous Systems Nonaqueous Systems Types and Arrangements of Absorption Equipment Design Techniques for Countercurrent Absorption Columns 11.5.1 Equilibrium Relationships 11.5.2 Ideal Solutions — Henry’s Law 11.5.3 Countercurrent Absorption Tower Design Equations 11.5.4 Origin of Volume-Based Mass-Transfer Coefficients 11.5.4.1 Steady-State Molecular Diffusion 11.5.5 The Whitman Two-Film Theory 11.5.6 Overall Mass-Transfer Coefficients 11.5.7 Volume-Based Mass-Transfer Coefficients 11.5.8 Determining Height of Packing in the Tower: the HTU Method 11.5.9 Dilute Solution Case 11.6 Countercurrent Flow Packed Absorption Tower Design 11.6.1 General Considerations 11.6.2 Operations of Packed Towers 11.6.3 Choosing a Tower Packing 11.6.3.1 Dumped Packings 11.6.4 Packed Tower Internals 11.6.5 Choosing a Liquid–Gas Flow Ratio 11.6.6 Determining Tower Diameter — Random Dumped Packing 11.6.7 Determining Tower Diameter — Structured Packing 11.6.8 Controlling Film Concept 11.6.9 A Correlation for the Effect of L/G Ratio on the Packing Height 11.6.10 Henry’s Law Constants and Mass-Transfer Information 11.6.11 Using Henry’s Law for Multicomponent Solutions 11.7 Sample Design Calculation 11.7.1 Flooding 11.7.2 Structured Packing References
© 2002 by CRC Press LLC
9588 fm frame Page 14 Wednesday, September 5, 2001 9:38 PM
Chapter 12 Adsorption for HAP and VOC Control 12.1 12.2 12.3
Introduction to Adsorption Operations Adsorption Phenomenon Adsorption Processes 12.3.1 Stagewise Process 12.3.2 Continuous Contact, Steady-State, Moving-Bed Adsorbers 12.3.3 Unsteady-State, Fixed-Bed Adsorbers 12.3.4 Newer Technologies 12.3.4.1 Rotary Wheel Adsorber 12.3.4.2 Chromatographic Adsorption 12.3.4.3 Pressure Swing Adsorption 12.4 Nature of Adsorbents 12.4.1 Adsorption Design with Activated Carbon 12.4.1.1 Pore Structure 12.4.1.2 Effect of Relative Humidity 12.5 The Theories of Adsorption 12.6 The Data of Adsorption 12.7 Adsorption Isotherms 12.7.1 Freundlich’s Equation 12.7.2 Langmuir’s Equation 12.7.3 The Brunner, Emmett, Teller, or BET, Isotherm 12.7.3.1 Adsorption without Capillary Condensation 12.7.3.2 Adsorption with Capillary Condensation 12.8 Polanyi Potential Theory 12.9 Unsteady-State, Fixed-Bed Adsorbers 12.10 Fixed-Bed Adsorber Design Considerations 12.10.1 Safety Considerations 12.11 Pressure Drop Through Adsorbers 12.12 Adsorber Effectiveness and Regeneration 12.12.1 Steam Regeneration 12.12.2 Hot Air or Gas Regeneration 12.13 Breakthrough Model 12.13.1 Mass Transfer 12.13.2 Breakthrough Curve Example 12.14 Regeneration Modeling References
Chapter 13 Thermal Oxidation for VOC Control 13.1 13.2
Combustion Basics Flares 13.2.1 Elevated, Open Flare 13.2.2 Smokeless Flare Assist 13.2.3 Flare Height
© 2002 by CRC Press LLC
9588 fm frame Page 15 Wednesday, September 5, 2001 9:38 PM
13.2.4 Ground Flare 13.2.5 Safety Features 13.3 Incineration 13.3.1 Recuperative Thermal Oxidizer 13.3.2 Regenerative Thermal Oxidizer 13.3.3 Recuperative vs. Regenerative Design Selection 13.4 Catalytic Oxidation References Chapter 14 Control of VOC and HAP by Condensation 14.1 14.2
Introduction VOC Condensers 14.2.1 Contact Condensers 14.2.2 Surface Condensers 14.2.2.1 An Example — Condensation Temperature 14.3 Coolant and Heat Exchanger Type 14.3.1 An Example — Heat Exchanger Area and Coolant Flow Rate 14.4 Mixtures of Organic Vapors 14.4.1 An Example — Condensation of a Binary Mixture 14.5 Air As a Noncondensable References Appendix A: Derivation of the Area Model for a Mixture Condensing from a Gas Appendix B: Algorithm for the Area Model for a Mixture Condensing from a Gas Chapter 15 Control of VOC and HAP by Biofiltration 15.1 15.2 15.3
Introduction Theory of Biofilter Operation Design Parameters and Conditions 15.3.1 Depth and Media of Biofilter Bed 15.3.2 Microorganisms 15.3.3 Oxygen Supply 15.3.4 Inorganic Nutrient Supply 15.3.5 Moisture Content 15.3.6 Temperature 15.3.7 pH of the Biofilter 15.3.8 Loading and Removal Rates 15.3.9 Pressure Drop 15.3.10 Pretreatment of Gas Streams 15.4 Biofilter Compared to Other Available Control Technology 15.5 Successful Case Studies 15.6 Further Considerations References
© 2002 by CRC Press LLC
9588 fm frame Page 16 Wednesday, September 5, 2001 9:38 PM
Chapter 16 Membrane Separation 16.1 Overview 16.2 Polymeric Membranes 16.3 Performance 16.4 Applications References Chapter 17 NOx Control 17.1
NOx from Combustion 17.1.1 Thermal NOx 17.1.2 Prompt NOx 17.1.3 Fuel NOx 17.2 Control Techniques 17.2.1 Combustion Control Techniques 17.2.1.1 Low-Excess Air Firing 17.2.1.2 Overfire Air 17.2.1.3 Flue Gas Recirculation 17.2.1.4 Reduce Air Preheat 17.2.1.5 Reduce Firing Rate 17.2.1.6 Water/Steam Injection 17.2.1.7 Burners out of Service (BOOS) 17.2.1.8 Reburn 17.2.1.9 Low-NOx Burners 17.2.1.10 Ultra Low-NOx Burners 17.2.2 Flue Gas Treatment Techniques 17.2.2.1 Selective Noncatalytic Reduction (SNCR) 17.2.2.2 Selective Catalytic Reduction (SCR) 17.2.2.3 Low-Temperature Oxidation with Absorption 17.2.2.4 Catalytic Absorption 17.2.2.5 Corona-Induced Plasma References Chapter 18 Control Of SOx 18.1 18.2
H2S Control SO2 (and HCl) Removal 18.2.1 Reagents 18.2.1.1 Calcium-Based Reactions 18.2.1.2 Calcium-Based Reaction Products 18.2.1.3 Sodium-Based Reactions 18.2.1.4 Sodium-Based Reaction Products 18.2.2 Capital vs. Operating Costs 18.2.2.1 Operating Costs
© 2002 by CRC Press LLC
9588 fm frame Page 17 Wednesday, September 5, 2001 9:38 PM
18.2.3
SO2 Removal Processes 18.2.3.1 Wet Limestone 18.2.3.2 Wet Soda Ash or Caustic Soda 18.2.3.3 Lime Spray Drying 18.2.3.4 Circulating Lime Reactor 18.2.3.5 Sodium Bicarbonate/Sodium Sesquicarbonate Injection 18.2.3.6 Other SO2 Removal Processes 18.2.4 Example Evaluation 18.3 SO3 and Sulfuric Acid 18.3.1 SO3 and H2SO4 Formation 18.3.2 Toxic Release Inventory References
Chapter 19 Fundamentals of Particulate Control 19.1 19.2 19.3 19.4
Particle-Size Distribution Aerodynamic Diameter Cunningham Slip Correction Collection Mechanisms 19.4.1 Basic Mechanisms: Impaction, Interception, Diffusion 19.4.1.1 Impaction 19.4.1.2 Interception 19.4.1.3 Diffusion 19.4.2 Other Mechanisms 19.4.2.1 Electrostatic Attraction 19.4.2.2 Gravity 19.4.2.3 Centrifugal Force 19.4.2.4 Thermophoresis 19.4.2.5 Diffusiophoresis References
Chapter 20 Hood and Ductwork Design 20.1 20.2
20.3
Introduction Hood Design 20.2.1 Flow Relationship for the Various Types of Hoods 20.2.1.1 Enclosing Hoods 20.2.1.2 Rectangular or Round Hoods 20.2.1.3 Slot Hoods 20.2.1.4 Canopy Hoods Duct Design 20.3.1 Selection of Minimum Duct Velocity 20.3.2 The Mechanical Energy Balance
© 2002 by CRC Press LLC
9588 fm frame Page 18 Wednesday, September 5, 2001 9:38 PM
20.3.2.1 Velocity Head 20.3.2.2 Friction Head 20.4 Effect of Entrance into a Hood 20.5 Total Energy Loss 20.6 Fan Power 20.7 Hood-Duct Example References
Chapter 21 Cyclone Design 21.1
Collection Efficiency 21.1.1 Factors Affecting Collection Efficiency 21.1.2 Theoretical Collection Efficiency 21.1.3 Lapple’s Efficiency Correlation 21.1.4 Leith and Licht Efficiency Model 21.1.5 Comparison of Efficiency Model Results 21.2 Pressure Drop 21.3 Saltation References
Chapter 22 Design and Application of Wet Scrubbers 22.1 22.2 22.3 22.4 22.5 22.6 22.7
Introduction Collection Mechanisms and Efficiency Collection Mechanisms and Particle Size Selection and Design of Scrubbers Devices for Wet Scrubbing The Semrau Principle and Collection Efficiency A Model for Counter-Current Spray Scrubbers 22.7.1 Application to a Spray Tower 22.8 A Model for Venturi Scrubbers 22.9 The Calvert Cut Diameter Design Technique 22.9.1 An Example Calculation 22.9.2 Second Example Problem 22.10 The Cut-Power Relationship References Additional References Appendix A: Calvert Performance Cut Diameter Data
Chapter 23 Filtration and Baghouses 23.1 23.2
Introduction Design Issues
© 2002 by CRC Press LLC
9588 fm frame Page 19 Wednesday, September 5, 2001 9:38 PM
23.3
Cleaning Mechanisms 23.3.1 Shake/Deflate 23.3.2 Reverse Air 23.3.3 Pulse Jet (High Pressure) 23.3.4 Pulse Jet (Low Pressure) 23.3.5 Sonic Horns 23.4 Fabric Properties 23.4.1 Woven Bags 23.4.2 Felted Fabric 23.4.3 Surface Treatment 23.4.4 Weight 23.4.5 Membrane Fabrics 23.4.6 Catalytic Membranes 23.4.7 Pleated Cartridges 23.4.8 Ceramic Candles 23.5 Baghouse Size 23.5.1 Air-to-Cloth Ratio 23.5.2 Can Velocity 23.6 Pressure Drop 23.7 Bag Life 23.7.1 Failure Modes 23.7.2 Inlet Design 23.7.3 Startup Seasoning References
Chapter 24 Electrostatic Precipitators 24.1 24.2
24.3
24.4
Early Development Basic Theory 24.2.1 Corona Formation 24.2.2 Particle Charging 24.2.3 Particle Migration 24.2.4 Deutsch Equation 24.2.4.1 Sneakage 24.2.4.2 Rapping Re-Entrainment 24.2.4.3 Particulate Resistivity 24.2.4.4 Gas-Flow Distribution Practical Application of Theory 24.3.1 Effective Migration Velocity 24.3.2 Automatic Voltage Controller Flue Gas Conditioning 24.4.1 Humidification 24.4.2 SO3 24.4.3 Ammonia 24.4.4 SO3 and Ammonia
© 2002 by CRC Press LLC
9588 fm frame Page 20 Wednesday, September 5, 2001 9:38 PM
24.4.5 Ammonium Sulfate 24.4.6 Proprietary Additives 24.5 Using V-I Curves for Troubleshooting References
© 2002 by CRC Press LLC
9588ch01 frame Page 1 Wednesday, September 5, 2001 9:39 PM
1
A Historical Overview of the Development of Clean Air Regulations
1.1 A BRIEF HISTORY OF THE AIR POLLUTION PROBLEM Media reports about air pollution might lead us to think of air pollution as being something that developed in the second half of the 20th century. But this is not so. The kind of air pollution to which human beings have been exposed has changed with time, but air pollution has been known in larger cities at least from the 14th century when people first started using coal for heating their homes.1 In England, during the reign of Edward I, there was a recorded protest by the nobility about the use of “sea” coal which burned in an unusually smoky manner. Under his successor, Edward II (1307–1327), a man was put to torture for filling the air with a “pestilential odor” through the use of coal. Under the reigns of Richard III and Henry V, England undertook to restrict the use of coal through taxation. Nevertheless, the situation continued to grow worse in the larger cities, so much so that during the reign of Elizabeth I (1533–1603, Queen, 1550–1603) Parliament passed a law forbidding the use of coal in the city of London while Parliament was in session. While this may have eased the pollution for the parliamentarians, it did very little to actually solve the problem. As cities grew and the Industrial Revolution developed, the spread of coal smoke grew. In 1686, a paper was presented to the Royal Philosophical Society on “An Engine That Consumes Smoke.” To this day we have been working on this same problem, as yet to no avail. Legislation that was introduced often ignored the technical aspects of the problem, and hence was unenforceable. For example, a law passed by Parliament in 1845 stated that locomotives must consume their own smoke, which would be grand but, of course, it is not realizable. The air pollution problem in the U.S. was first recognized as being due to coal smoke. In 1881 Chicago adopted a smoke control ordinance. St. Louis, Cincinnati, and other cities also adopted smoke ordinances in the years that followed. In these early years, it was established that the responsibility rested with the state and local governments. Nashville, Tennessee had a population of 80,865 in 1900, and it was a typical community of that period that depended on bituminous coal for heating. A short story written by O’Henry describes his visit to Nashville in 1900 as follows:
© 2002 by CRC Press LLC
9588ch01 frame Page 2 Wednesday, September 5, 2001 9:39 PM
A MUNICIPAL REPORT Nashville — a city, port of delivery, and the capital of the state of Tennessee, is on the Cumberland River and on the N.C. & St. L. and the L&N Railroads. This city is regarded as the most important educational centre in the South. I stepped off the train at 8 P.M. Having searched thesaurus in vain for adjectives, I must, as a substitution, hie me to comparison in the form of a recipe: “ Take of London fog, thirty parts; malaria, ten parts; gas leaks, twenty parts; dewdrops gathered in a brick-yard at sunrise, twenty-five parts; odor of honeysuckle, fifteen parts. Mix. The mixture will give you a approximate conception of a Nashville drizzle. It is not so fragrant as a moth ball, nor as thick as pea soup; but ’tis enough — ’twill serve.”
From 1930 to 1941, the focus of air pollution was on smoke control laws. Public protest groups from Chicago, St. Louis, Cincinnati, and Pittsburgh had some success. However, air pollution was not recognized as the health hazard we know it to be today. In 1941 war was declared on the Axis Powers of Germany and Japan and their allies, and from late 1941 until 1945, there was an all-out effort to defeat these countries. This effort allowed no time nor materials for air pollution control. Smoke levels reached new highs as the national effort rallied to the war. Finally with a return to peace, action on pollution control was initiated. In the prewar era, Pittsburgh had enacted a stringent new control regulation. In October 1946, a regulation which centered on the type of coal used was put into effect. Then, in October of 1948, tragedy struck at Donora, Pennsylvania.2 Weather conditions were perfect for a stagnating inversion. As the inversion deepened, people in Donora became ill, and 20 died from the effects of the excessive air pollution which was prevalent. The result was an awakening to the health hazards of air pollution. Other such incidents were recognized throughout the world as indicated in Table 1.1 compiled from several sources.2-4 Thus, October 1948 marks the start of a more vigorous program of air pollution control in the U.S. For example, on May 1, 1949 the Pittsburgh smoke ordinance was extended to the whole of Allegheny County. Air pollution abatement was soon to attract the public’s eye and money, but it wasn’t until the advent of the Clean Air Act of 1963 that there was a national awakening to the value of our air environment. During World War II a new type of air pollution had been discovered in the Los Angeles atmosphere. New effects were manifest in the form of eye and skin irritation and plant damage not evident from simple smoke pollution. It was the result of a photochemical smog that was at first attributed to the oil refineries and storage facilities. When controls of these facilities did not result in a significant reduction of the problem, it was then discovered that the internal combustion engine was a major cause of this new type of pollution. The result of photochemical oxidation is seen in the brown haze apparent in the upper layer of the atmosphere. The brown haze is a mixture of particulates, oxides of nitrogen, sulfuric-acid mist condensed from the oxidation of sulfur dioxide, and particles produced from photochemical reaction in the atmosphere. The haze limits visibility, decreases the
© 2002 by CRC Press LLC
9588ch01 frame Page 3 Wednesday, September 5, 2001 9:39 PM
TABLE 1.1 The Horrible Total-Man Breathes, Coughs, and Dies Location
Date
Meuse Valley, Belgium Donora, PA
12/1/30 10/26/48
London Poza Rica, Mexico London New York, NY London London London London London New York, NY New York, NY
11/26/48 11/21/50 12/5/52 11/22/53 11/56 12/2/57 1/26/59 12/5/62 1/7/63 1/9/63 11/23/66
Deaths* 63 18 700–800 22 3500–4000 175–260 1000 700–800 200–250 700 700 200–400 170
Reported Illness 6000 5900 (43%)
Common Conditions Low atmospheric dilution Fog and gaseous materials
>320 Unknown Unknown Unknown
Unknown
*Number of deaths above expected average death rate.
amount of sunlight reaching the earth, results in an increase in the amount of cloudy weather present, and, when it accumulates, results in all the unpleasant effects we associate with air pollution. Perhaps it was in response to these visual signs of air pollution that people could see occurring that the nation decided to act. Most certainly it was at this point that the federal government entered the picture.
1.2 FEDERAL INVOLVEMENT IN AIR POLLUTION CONTROL After the World War II and the advent of the air pollution episodes in Donora and London, it became apparent that a more concerted federal action was required. Congress first passed an air pollution law in 1955. At this time, Congress was particularly reluctant to interfere in states’ rights, and early laws were not strong. These laws more or less defined the role of the federal government in research and training in air pollution effects and control. The following brief summary leads up to the 1970 Amendments to the Clean Air Act, beginning with: The Air Pollution Control Act of 1955, Public Law 84-159, July 14, 1955 • Left states principally in charge of prevention and control of air pollution at the source • Recognized the danger to the population of the growing problem • Provided for research and training in air pollution control
© 2002 by CRC Press LLC
9588ch01 frame Page 4 Wednesday, September 5, 2001 9:39 PM
Air Pollution Control Act Amendments of 1960, Public Law 86-493, June 6, 1960 and Amendments of 1962, Public Law 87-761, October 9, 1962 • Directed the Surgeon General to conduct a thorough study of the effects of motor vehicle exhausts on human health The Clean Air Act of 1963, Public Law 88-206, December 1963 • Encouraged state and local programs for the control and abatement of air pollution while reserving federal authority to intervene in interstate conflicts • Required development of air quality criteria which would be used as guides in setting ambient and emission standards • Provided research authority to develop methods for removal of sulfur from fuels Motor Vehicle Air Pollution Control Act of 1965, Public Law 89-272, October 20, 1965 • Recognized the technical feasibility of setting automobile emission standards • Determined that such standards must be national standards and relegated automotive emission control to the federal government • Gave the state of California waivers to develop standards more appropriate to the local situation The Air Quality Act of 1967, Public Law 90-148, November 21, 1967 • Designated air quality control regions (AQCRs) within the USA, either inter- or intrastate • Required issuance of air quality criteria • Required states to established air quality standards consistent with air quality criteria in a fixed time schedule • Gave states primary responsibility for action, but a very strong federal authority was provided • Required development and issuance of information on recommended air pollution control technique The Clean Air Amendments Act of 1970, Public Law 91-604, December 31, 1970 • Created the Environmental Protection Agency (EPA) • Required states to prepare implementation plans on a given time schedule • Set automotive emission standards • Set the following basic control strategy to be employed, establishing a. National Ambient Air Quality Standards (NAAQS) b. Standards of performance for new stationary sources c. National emission standards for hazardous pollutants The Clean Air Act of 1970 and the Clean Air Act Amendments of 1977 are discussed in more detail in Chapter 2.
© 2002 by CRC Press LLC
9588ch01 frame Page 5 Wednesday, September 5, 2001 9:39 PM
FIGURE 1.1 Layers of the atmosphere.
1.3 CHARACTERIZING THE ATMOSPHERE The atmosphere seems boundless, but of course it isn’t! If we consider the relative amount of all living matter of mass equivalent to 1.0 unit; then the atmosphere, that is all gases as we know them, would be about 300 units, and the hydrosphere, all waters, oceans, lakes, rivers, streams, ponds, etc. would be about 70,000 units. Figure 1.1 illustrates the layers of the atmosphere. • Ionosphere (above 50 km) — ions and activated molecules produced by ultraviolet radiation such as in the following reaction: O2 = hv → 0 − + 0 − • Stratosphere (11 to 50 km) — layer in which chemical composition changes takes place as illustrated by the following chain reaction: NO2 + hv → NO + O − O + O 2 + M → O3 + M O3 + NO → NO2 + O2 Sinks above polar caps may be responsible for these actions. Temperature variation with altitude is small. • Troposphere (0 to 11 km) — area of major concern in air pollution: Temperature decreases with altitude. Micrometeorological processes control the amount of pollution as it spreads and reaches ground level.
© 2002 by CRC Press LLC
9588ch01 frame Page 6 Wednesday, September 5, 2001 9:39 PM
TABLE 1.2 Chemical Composition of Normal Air Substance
% By Volume in Dry Air
N2 O2 Ar CO2 Ne He CH4 Kr N2O H2 Xe
78.09% 20.94% 0.93% 0.03% 0.0018% 0.00052% 0.00022% 0.00010% 0.00010% 0.00005% 0.00008%
Note: 1 ppm by volume = 0.0001% by volume.
Table 1.2 records the chemical composition of air. Air normally contains water vapor which would be somewhere around 1% by volume of the total mixture. The concentrations in Table 1.2 remain nearly constant or vary slowly. The following are variable in their concentration: 1. 2. 3. 4. 5. 6.
Water > variable 1.0% by volume Meteoric dust Sodium chloride Soil NO2 formed by electric discharge O3 formed by electric discharge
7. 8. 9. 10. 11. 12. 13.
Pollen Bacteria Spores Condensation nuclei SO2 volcanic oxygen HCl volcanic origin HF of volcanic origin
When doing combustion calculations it is usual to assume that dry air contains 21% by volume of O2 and 79% by volume of N2. Table 1.3 compares concentrations of what could be considered pure air to concentrations in polluted air. Table 1.4 is a historical record of concentrations of pollutants in cities in the U.S. in 1956, compiled by H. C. Wohlers and G. B. Bell at the Stanford Research Institute.
1.4 RECIPE FOR AN AIR POLLUTION PROBLEM To have an air pollution incident, such as the one that occurred in Donora, or to have a problem, such as in Nashville, there are three factors that must occur simultaneously. There must be sources, a means of transport, and receptors. Figure 1.2 illustrates the process. Air pollution sources are relatively common knowledge. Their strength, type, and location are important factors. By transport, reference is made
© 2002 by CRC Press LLC
9588ch01 frame Page 7 Wednesday, September 5, 2001 9:39 PM
TABLE 1.3 A Comparison of Pure Air and a Polluted Atmosphere Component
Considered to Be Pure Air
Typical Polluted Atmosphere
10–20 µg/m3 0.001–0.01 ppm 300–330 ppm 1 ppm 0.001–0.01 ppm 1 ppm 0.01 ppm
260–3200 µg/m3 0.02–3.2 ppm 350–700 ppm 2–300 ppm 0.30–3.5 ppm 1–20 ppm 0.01–1.0 ppm
Particulate matter Sulfur dioxide Carbon dioxide Carbon monoxide Oxides of nitrogen Total hydrocarbons Total oxidant
TABLE 1.4 Ranges of Concentrations of Gaseous Pollutants — A Historical Record from 1956
Pollutant Aldehyde (as formaldehyde) Ammonia Carbon monoxide Hydrogen fluoride Hydrogen sulfide Nitrogen oxides Ozone Sulfur dioxide
Range of Average Concentrations (ppm)
Range of Maximum Concentrations (ppm)
Number of Cities from Which Data Was Compiled
0.02–0.2
0.03–2.0
8
0.02–0.2 2.0–10.0 0.001–0.02 0.002–0.1 0.02–0.9 0.009–0.3 0.001–0.7
0.05–3.0 3.0–300 0.005–0.08 Up to 1.0 0.03–3.5 0.03–1.0 0.02–3.2
7 8 7 4 8 8 50
Source: Compiled by H. C. Wohlers and G.B. Bell, Stanford Research Institute Project No. SU-1816 (1956).
to the meteorological conditions, and the topography and climatology of a region, which are the important factors in dispersion — that is, in getting the material from the sources to the receptors. The receptors include human beings, other animals, materials, and plants. We also know that air pollution can affect visibility and can endanger our lives simply by making it difficult to travel on the highways and difficult for planes to land. The dollar cost of air pollution is the subject of much debate. However, it must be an astronomical figure especially when you add such things as the extra dry cleaning and washing, houses that need more paintings than they should, etc. The dollars lost to poor crops is a costly item in our economy, notwithstanding the impairment to shrubs, flowers, and trees. © 2002 by CRC Press LLC
9588ch01 frame Page 8 Wednesday, September 5, 2001 9:39 PM
FIGURE 1.2 The trilogy: Sources — Transport — Receptors.
1.4.1 SOURCES
OF
AIR POLLUTION
Sources of air pollution are either man made or natural. Man-made sources are what we focus on because we may be able to effect some control of these sources. Both gaseous and particulate sources are troublesome. We have set standards for concentrations for both these materials in the atmosphere and in emission from chimneys for those sources we have recognized to be harmful. The concentration and the flow rate of the emissions are information required to determine the downwind transport of the pollutants. Knowing the location of the source relative to the receptor would allow us to calculate the concentration at a particular downwind receptor using a dispersion model. In Chapter 2 there is more detail about the pollutants which we are trying to control. The Environmental Protection Agency (EPA) estimates the quantities of pollutants emitted each year. This information and many other facts are available at: http//www.epa.gov/airtrends. Figure 1.3 records the annual production of air pollution by categories.
1.4.2 METEOROLOGICAL PARAMETERS AFFECTING TRANSPORT OF POLLUTANTS The meteorological characteristics of the Los Angeles and Donora areas combine with the topographical features to form a container that traps the contaminants. The mountains in Los Angeles and the river valley in Donora form the walls of the containers that hamper horizontal air flow through these areas. A high pressure area over the region forms the lid of such a container. A temperature inversion occurs, and the air becomes thermally stable, which has the effect of stopping vertical air flow, reinforcing the “lid” effect. In this way, the polluted air is not allowed to flow up and over the mountains or hills. Meteorologists have long known that the amount of vertical motion of the atmosphere depends to an important extent on how the temperature varies with © 2002 by CRC Press LLC
9588ch01 frame Page 9 Wednesday, September 5, 2001 9:39 PM
FIGURE 1.3 Annual production of pollutants by categories.
altitude. Near the ground, air temperature normally decreases with height. When the rate of decrease is rapid, there is a pronounced tendency toward vertical air mixing. On the other hand, when the air temperature increases with height, vertical air motions are suppressed. This temperature structure is called a “temperature inversion” because it is “inverted” from the normal condition of temperature decreasing with height. Under adiabatic conditions, the temperature of dry air decreases at 5.45°F for each gain in altitude of 1000 feet. This temperature gradient is known as the Dry Adiabatic Lapse Rate (DALR). However, when the temperature of the air increases as the altitude increases, a condition known as an inversion is present. An inversion may take place at the surface or in the upper air. A surface or radiation inversion usually occurs on clear nights with low wind speed. In this situation, the ground cools the surface air by nature of its own cooling due to long wave radiation of heat to the outer atmosphere. The surface air becomes cooler than the upper layers, and vertical air flow is halted. (Hot air rises, cool air sinks.) A parcel of warm air trying to rise finds the air above it hotter than itself. Thus, it will not rise because the temperature gradient is inverted. This type of inversion is common and is broken up as the sun once again heats the ground the next morning. In Los Angeles the typical inversion occurs in the upper air. There is an almost permanent high pressure area centered over the north Pacific near the city. The axis of this high is inclined in such a way that air reaching the California coast is descending or subsiding. During the subsidence, the air is heated by compression creating an inversion of the temperature gradient in the upper atmosphere over the city as the air moves from the sea over the land. This is termed a subsidence inversion. Since the surface air in the Los Angeles area usually results from the sea breeze, the temperature difference between the upper layer and the surface is increased. The © 2002 by CRC Press LLC
9588ch01 frame Page 10 Wednesday, September 5, 2001 9:39 PM
water is relatively cold and so the surface air that moves on over the land as the sea breeze is also cold. One might think that the daily cycle of sea and land breezes would break up the inversion, but this is not the case. The sea breezes only serve to raise and lower the altitude of the inversion layer. In the Los Angeles area, the effect of large air masses overrides the effect of the less powerful local heating from the surface. In Donora in the fall of 1948, as in London 4 years later, the weather was the wicked conspirator. A high pressure area moved over western Pennsylvania on October 26, 1948, and remained fairly stationary for the next 5 days. Winds in the lowest 2000 feet of the atmosphere were quite weak. Mostly they were between a dead calm and 3 mph, but for brief periods they were slightly higher. The air was “thermally stable,” a formal description implying that there was very little vertical motion of the air. Donora, lying near the bottom of a steep valley, is about 500 feet below the surrounding terrain. During the period October 26 to 31, 1948, an inversion capped the valley. Pilot reports and weather balloons showed that the cap, at least part of the time, was less than 1000 feet above the town. Thus, smoke fed to the atmosphere was largely confined within the valley walls and the inversion top. The air near the ground was very humid. Fog formed in the night, and in some low-lying areas of western Pennsylvania, it persisted during the day. At Donora, the visibility, cut by smoke and fog, ranged from about 0.6 to 1.5 miles. The overall weather conditions were similar to those that occurred in London, and the consequences tragically alike.
1.4.3 THE EFFECTS OF AIR POLLUTION — A COMPARISON OF LONDON FOG AND LOS ANGELES SMOG What makes a Los Angeles fog different from a London fog? Here is a list of a few conditions that apply to both. They are both similar in that they result in community air pollution, and the major source is the combustion of fuels. In London, it is coal and many hydrocarbons. In Los Angeles, it is primarily hydrocarbons. The peak time in London is early morning. In Los Angeles the peak time is midday. In London the temperature is 30 to 40°F; in Los Angeles, 75 to 90°F. The humidity is high with fog in London. Generally speaking, in Los Angeles, pollution occurs on a relatively clear day with low humidity. The inversions in London are at the surface, in Los Angeles inversions are overhead. Visibility is severely reduced in London, but only partially reduced in Los Angeles. The effects in London are to produce bronchial irritation, whereas in Los Angeles the effects are to produce eye and skin irritations. In Los Angeles, the smog is primarily produced through photochemical oxidation of the hydrocarbons by the ozone and nitrogen oxides that are in the atmosphere. The product of this photochemical reaction is an organic type molecule that causes plant damage and reduced visibility, and irritates skin and eyes very badly. The London type chokes us. We get a feeling of being in the midst of a big smoke, because that is primarily what it is — smoke and fumes mixed with moisture in the air. A summary of these conditions is given in Table 1.5. Both problems result from community air pollution. However, Los Angeles is different from London, Pittsburgh, and St. Louis. © 2002 by CRC Press LLC
9588ch01 frame Page 11 Wednesday, September 5, 2001 9:39 PM
TABLE 1.5 A Comparison of London Smog and Los Angeles Smog Condition Fuel Season during year Peak time Temperature Humidity Wind speed Inversions Visibility Principal constituents Effects on humans Chemical effects
London
Los Angeles
Coal and hydrocarbons Dec.–Jan. Early morning 30–40°F High with fog Calm Surface (radiation) Severely reduced (16.5 ppm
Area that can achieve attainment by November 1996 Area that cannot achieve compliance by November 1996
2.2.1 TITLE I: PROVISIONS FOR ATTAINMENT AND MAINTENANCE OF NATIONAL AMBIENT AIR QUALITY STANDARDS The 1990 CAAA recognized that many urban areas were not in attainment of the NAAQS, and that there were major problems with high levels of tropospheric ozone, carbon monoxide. To address the problems practically, the Amendments extended the time for states to achieve compliance, but required constant progress in reducing emissions and established provisions for sanctions on areas of the country that do not meet the conditions. The new amendments also established degrees of severity for non-attainment for ozone, carbon monoxide, and particulate matter with an aerodynamic diameter of less than 10 microns (PM10). Ozone non-attainment was broken into five degrees of severity, as listed in Table 2.3. Areas of extreme severity were allowed more time to achieve attainment, but receive increased federal scrutiny for new source review of major sources. The definition of “major” stationary source, discussed further in new source review permit applications in the next chapter, applies to smaller sources, and the emission offset ratio requirement for new sources is increased. Carbon monoxide (CO) and particulate matter degrees of severity for nonattainment were established at two levels as shown in Table 2.4. 2.2.1.1 NAAQS Revisions Current NAAQS as of February 2001 are listed in Table 2.5. The Clean Air Act requires that the EPA reviews all its air standards every 5 years to determine if new © 2002 by CRC Press LLC
9588ch02 frame Page 19 Wednesday, September 5, 2001 9:40 PM
TABLE 2.5 National Ambient Air Quality Standards Primary
Ozone PM-10 CO SO2 NO2 Lead
Ozone PM-2.5
Secondary
Level
Averaging Time
Level
Averaging Time
0.12 ppm 150 µg/m3 50 µg/m3 35 ppm 9 ppm 0.14 ppm 0.030 ppm 0.053 ppm 1.5 µg/m3
1h 24 h 1 yr. 1h 8h 24 h 1 yr. 1 yr. 3 mo.
Ozone PM-10
0.12 ppm 150 µg/m3 50 µg/m3 35 ppm 9 ppm 0.14 ppm 0.030 ppm 0.053 ppm 1.5 µg/m3
0.08 ppm 65 µg/m3 15 µg/m3
CO SO2 NOx Lead
Proposed New Standards 8h 24 h 1 yr.
studies and scientific evidence warrant revisions to the standards. In 1997, the EPA issued a new primary and secondary ozone standard of 0.08 ppm for an 8-hour average in addition to the existing standard of 0.12 ppm for a 1-hour average. The EPA determined that longer-term exposures to lower levels of ozone caused health effects including asthma attacks, breathing and respiratory problems, loss of lung function, and possible long-term lung damage and decreased immunity to disease. This was the first update of the ozone standard in 20 years. Also in 1997, EPA established a new particulate matter standard for fine particulates with an aerodynamic diameter of less than 2.5 microns (PM2.5). The standard was established at 65 µg/m3 for a 24-hour average and 15 µg/m3 for an annual average. The new standards followed a lawsuit by the American Lung Association that the EPA missed the deadline for the required review of the particulate standard. The previous review of the particulate standard was conducted in 1987. A new courtordered deadline of July 1997 was established to finalize the particulate standard, and the EPA finalized the ozone standard simultaneously. In May 1999, the new ozone and particulate standards were remanded by the Court of Appeals following a lawsuit by the American Trucking Association. The key issue was neither the quality of the health-based review, the review process, nor the degree of public health concern. Indeed, the Court of Appeals agreed that there was growing empirical evidence demonstrating a relationship between fine particle pollution and adverse health effects that justified a new fine particle standard. Instead, the key issue centered around EPA’s authority to establish a standard for a “nonthreshold” pollutant that weighs health with the cost of implementing the standard. A threshold pollutant is one that exhibits a minimum level, or threshold, below which no health effects are observed. A non-threshold pollutant has diminishing health effects with decreasing concentration, but there will always be some effect © 2002 by CRC Press LLC
9588ch02 frame Page 20 Wednesday, September 5, 2001 9:40 PM
80 70 60 50 40
Data
30
No Threshold
20 Threshold 10 0 0.0
0.1
0.2
0.3
0.4
0.5
0.6
FIGURE 2.1 Threshold vs. no threshold response. (Adapted from De Neveres, N., Air Pollution Control Engineering, Copyright 1995. The McGraw-Hill Companies, Inc., p. 16.)
even at extremely low concentrations. Threshold and non-threshold pollutant responses are illustrated in Figure 2.1. The data are the difference in mortality between mice exposed to ozone and an unexposed control group, then both subsequently exposed to Streptococcus bacteria.4 Figure 2.1 also demonstrates the difficulty in collecting data to measure and interpret a threshold level. A large number of expensive data at very low concentrations and with very small responses may be required to detect a threshold. If a pollutant indeed has no health-based threshold, then the only healthy level is zero, which is impractical. Therefore, a judgment that compromises an acceptable level of health risk with a reasonable implementation cost must be reached, and such judgment constitutes establishing policy. The Court of Appeals said that the EPA lacked any determinate criterion for establishing where the standard for a nonthreshold pollutant should be set, so choosing a standard was capricious and arbitrary. In a decision of two to one, the Court of Appeals determined that the Clean Air Act, as applied and absent further clarification, is unconstitutional because it gives “an unconstitutional delegation of legislative power” to the EPA. The dissenting opinion of the Court was that this interpretation “ignores the last half-century of Supreme Court nondelegation jurisprudence.” EPA appealed to the Supreme Court. On February 27, 2001, the Supreme Court unanimously upheld the constitutionality of EPA’s interpretation in setting the 1997 NAAQS revisions. Specifically, the Supreme Court held that the Clean Air Act does not permit the EPA to consider implementation costs in setting NAAQS, and disagreed that EPA lacked determinate criteria for drawing the lines that guide the protection of public health.5
2.2.2 TITLE II: MOBILE SOURCES Cars and trucks account for almost half the emissions of the ozone precursors, VOCs and NOx, and up to 90% of the CO emissions in urban areas. Although today’s motor © 2002 by CRC Press LLC
9588ch02 frame Page 21 Wednesday, September 5, 2001 9:40 PM
vehicles emit less pollution (60 to 80% less, depending on the pollutant) than those built in the 1960s, there has been a rapid growth in the number of vehicles on the roadways and in the total miles driven, which has offset a large portion of the emission reductions gained from motor vehicle controls. The 1990 Amendments established standards that reduced tailpipe emissions of VOCs, NOx, and CO on a phased-in basis beginning in model year 1994. Automobile manufacturers also are required to reduce vehicle emissions resulting from the evaporation of gasoline during refueling. Reductions in the vapor pressure of gasoline and the sulfur content of diesel fuel also are required. Reformulated gasoline programs were initiated in 1995 for cities with the worst ozone problems. Higher levels (2.7%) of alcohol-based oxygenated fuels are produced and sold in areas that exceed the NAAQS for CO during the winter months. The new law also established a clean fuel car pilot program in California, and a program limiting emissions from centrally fueled fleets of 10 or more vehicles in several areas of the country with severe smog problems.
2.2.3 TITLE III: HAZARDOUS AIR POLLUTANT PROGRAM The 1990 Amendments took a completely new approach toward controlling hazardous air pollutants (HAPs). HAPs are those pollutants that are hazardous to human health or the environment but are not specifically covered under another portion of the Clean Air Act. These pollutants are typically carcinogens, mutagens, and reproductive toxins. The original NESHAP program was based on establishing healthbased standards for individual HAPs, but this approach became bogged down and unproductive with its burdensome requirements for regulatory development. The new program requires establishment of technology-based standards for source categories that originally included 189 different HAPs, although caprolactam, used for manufacturing nylon, has been de-listed. The idea was to stop worrying about the specifics of health and risk for specific chemicals and start taking action by applying established control technologies to industrial sources. A determination of health-based “residual risk” could come later. A second major portion of Title III was requiring plans to prevent and mitigate accidental releases of HAPs. The new technology-based NESHAP program requires the EPA to determine Maximum Achievable Control Technology (MACT) standards for major sources of HAPs. Major sources are defined as facilities with the potential to emit (PTE) 10 tons per year of any single HAP or a total of 25 tons per year of all listed HAPs. The “potential to emit” is key, as opposed to actual emissions. 2.2.3.1 Source Categories In 1992, the EPA published a list of 174 major source categories, e.g., alkyd resins production; polystyrene production; petroleum refineries–catalytic cracking; catalytic reforming; and sulfur plant units; primary aluminum production; primary copper smelting; and industrial boilers. The list was updated in 1998, and again in 1999.6 Among other changes, the latest revision added six new source categories (cellulosic sponge manufacturing, brick and structural clay products manufacturing, ceramics © 2002 by CRC Press LLC
9588ch02 frame Page 22 Wednesday, September 5, 2001 9:40 PM
TABLE 2.6 Area Source Categories Original Asbestos processing Chromic acid anodizing Commercial sterilization facilities Halogenated solvent cleaners Commercial dry cleaning transfer machines Commercial dry cleaning dry-to-dry machines Hard chromium electroplating Decorative chromium electroplating
Added Secondary lead smelting Hazardous waste incineration Portland cement manufacturing Secondary aluminum production
manufacturing, clay minerals processing, lightweight aggregate manufacturing, and wet-formed fiberglass mat production) and deleted two source categories (aerosol can-filling facilities and antimony oxides manufacturing). Eight area source categories were listed for small stationary sources that were considered to pose a health threat on an individual or aggregate basis. Area sources are required to use Generally Available Control Technology (GACT). The area sources are listed in Table 2.6. The original schedule for MACT and GACT standards called for promulgating 40 standards by November 1992, 28 by November 1994, 28 by November 1997, and 54 by November 2000. These are designated 2-, 4-, 7-, and 10-year standards. It soon became apparent that the EPA could not meet this schedule, and a lawsuit resulted in a consent decree for court-ordered deadlines that required standards for 14 major sources and 4 area sources to be promulgated by July 1993.7 Court-ordered deadlines tend to be missed less frequently than statutory deadlines to avoid the legal issue of being held in contempt of court. A list of source categories for which MACT standards have been promulgated is provided in Table 2.7. Source categories for which MACT standards have been proposed or are scheduled to be proposed is provided in Table 2.8. 2.2.3.2 Establishing MACT Standards The EPA must establish technology-based MACT standards for new and existing sources in the source categories. The minimum level of this technology is called the “MACT floor.” First, EPA establishes the floor, then determines if the cost and benefit warrant more stringent technology, or going “beyond the floor.” To evaluate the control technologies, EPA collects information from companies by sending “114 Letters,” which must be answered under the authority of section 114 of the CAA. The information includes emissions, controls, and costs. The EPA also may require source testing of designated facilities. For existing facilities, the “floor” is the technology used by the best-performing 12% of the existing sources within a source category; unless there are fewer than 30 sources, in which case the standard must be at least as stringent as the average © 2002 by CRC Press LLC
9588ch02 frame Page 23 Wednesday, September 5, 2001 9:40 PM
23
TABLE 2.7 Final MACT Standards (as of March 6, 2001) Standard and Source Category
40 CFR 63 Subpart
Federal Register
2-Year Bin Originally Due 11/15/92 Dry cleaning: M 9/22/93 Commercial dry-to-dry (Area) Commercial transfer machines (Area) Commercial transfer machines Industrial dry-to-dry Industrial transfer machines Synthetic organic chemical manufacturing F, G, H, I 4/22/94 (hazardous organic NESHAP or HON)
4-Year Bin Originally Due 11/15/94 Aerospace GG 9/1/95 Asbestos — Delisted 11/30/95 Chromium Chemicals Manufacturing — Delisted 11/30/95 Chromium electroplating: N 1/25/95 Chromic acid anodizing Chromic acid anodizing (Area) Decorative chromium electroplating Decorative chromium electroplating (Area) Hard chromium electroplating Hard chromium electroplating (Area) Coke ovens L 10/27/93 Commercial sterilizers: O 12/6/94 Commercial sterilization facilities Commercial sterilization facilities (Area) Degreasing organic cleaners: T 12/2/94 Halogenated solvent cleaners Halogenated solvent cleaners (Area) Gasoline distribution (Stage 1) R 12/14/94 Hazardous waste combustors Parts 63, 261, 9/30/99 and 270 Industrial cooling towers Q 9/8/94 Magnetic tape EE 12/15/94 Marine vessel loading operationsc Off-site waste recovery operations Petroleum refineries Polymers and Resins I: Butyl rubber Epichlorohydrin elastomers Ethylene propylene rubber Hypalon™ production Neoprene production © 2002 by CRC Press LLC
Y DD CC U
9/19/95 7/1/96 8/18/95 9/5/96
Compliance Date
9/23/96
5/12/98 5/12/99 5/14/01
9/1/98 — — 1/25/96 1/25/97
— 12/6/98
12/2/97
12/15/97 9/30/02 3/8/95 12/15/96 12/15/97 9/19/95 7/1/96 8/18/98 7/31/97
9588ch02 frame Page 24 Wednesday, September 5, 2001 9:40 PM
TABLE 2.7 (continued) Final MACT Standards (as of March 6, 2001) Standard and Source Category Nitrile butadiene rubber Polybutadiene rubber Polysulfide rubber Styrene-butadiene rubber and latex Polymers and Resins II: Epoxy resins production Non-nylon polyamides production Polymers and Resins IV: Acrylonitrile-butadiene-styrene production Methyl methacrylate-acrylonitrilebutadiene-styrene production Methyl methacrylate-butadiene-styrene terpolymers production Styrene-acrylonitrile production Polyethylene terephthalate production Printing/publishing Secondary lead smeltersc Shipbuilding and ship repair Wood furniture
40 CFR 63 Subpart
Federal Register
W
3/8/95
3/3/98
JJJ
9/12/96
7/31/97
KK X H JJ
5/30/96 6/23/95 12/16/95 12/7/95
5/30/99 6/23/97 12/16/96 11/21/97
7-Year Bin Originally Due 11/15/97 Aerosol can-filling facilitiesc — Delisted Antimony oxides manufacturingc — Delisted Chromium chemical manufacturing — Delisted Electric arc furnace: stainless and non— Delisted stainless steel Ferroalloys production: silicomanganese and XXX 5/20/99 ferromanganese Flexible polyurethane foam production III 10/7/98 Generic MACT: YY 6/29/99 Acetal resins Hydrogen fluorideb Polycarbonates production Acrylic/modaacrylic fibers Mineral wool production DDD 6/1/99 Non-stainless steel manufacturing — electric — Delisted arc furnace operation Nylon 6 production — Delisted Oil and natural gas production HH 6/17/99 Pesticide active ingredient production MMM 6/23/99 Pharmaceuticals production GGG 9/21/98 Phosphate fertilizers productionc BB 6/10/99 Phosphoric acid manufacturingc AA 6/10/99
© 2002 by CRC Press LLC
Compliance Date
11/18/99 11/18/99 6/4/96 6/4/96
— — — — 5/20/01 10/8/01 6/29/02
6/1/02 6/4/96 2/12/98
— 6/17/02 6/30/02 9/21/01 6/10/02 6/10/02
9588ch02 frame Page 25 Wednesday, September 5, 2001 9:40 PM
TABLE 2.7 (continued) Final MACT Standards (as of March 6, 2001) Standard and Source Category Polyether polyols production Polymers and Resins III: Amino/phenolic resins Portland cement manufactruing Primary aluminum productioin Primary lead smelting Publicly owned treatment works Pulp and paper (non-combust) MACT I Pulp and paper (non-combust) MACT III Secondary aluminum production Stainless steel manufacturing — electric arc furnace operation Steel pickling-HCl process facilities and hydrochloric acid regeneration plants Tetrahydrobenzaldehyde manufacture Wood treatment Wool fiberglass manufacturing
40 CFR 63 Subpart
Federal Register
PPP OOO
6/1/99 1/20/00
6/1/02 —
LLL LL TTT VVV S S RRR —
6/14/99 10/7/97 6/4/99 10/26/99 4/15/98 3/8/96 3/23/00 Delisted 6/4/96
6/10/02 10/7/99 6/4/02 10/26/02 4/15/01 4/16/01 — —
CCC
6/22/99
6/22/01
F — NNN
5/12/98 Delisted 6/4/96 6/14/99
5/12/01 — 6/14/01
10-Year Bin Originally Due 11/15/00 Combustion sources at kraft, soda, and sulfite MM 12/15/00 pulp and paper millsa Cyanuric chloride production — Delisted 2/12/98 Lead acid battery manufacturing — Delisted 5/17/96 Natural gas transmission and storage HHH 6/17/99 a b
Compliance Date
— — — 6/17/02
Moved from 7-year bin. Moved from 10-year bin.
of the five best-performing facilities. This may not be as onerous as it first appears. In some industries, the same control technology is commonly used by most facilities. New source performance standards have been established for a long time for some source categories. It may well be that the best-performing 12% of sources use the same control technology as the best-performing 80% of the existing sources. Then, if MACT is set at the floor level, only 20% of the existing facilities would have to be upgraded to comply with MACT. For new (and reconstructed) sources, the MACT “floor” is the single bestcontrolled similar facility within the source category. Again, if all of the bestperforming plants use the same technology, this stringent requirement does not necessarily require that new technology will be required. The EPA can, however, determine that available technology and the cost and health benefits warrant control technology that is more stringent than the floor technology. Typically, cost effectiveness is expressed in terms of dollars per ton of
© 2002 by CRC Press LLC
9588ch02 frame Page 26 Wednesday, September 5, 2001 9:40 PM
TABLE 2.8 Planned MACT Standards (as of March 6, 2001) Standard and Source Category 10-Year Bin Originally Due 11/15/00 Alumina processing Asphalt concrete manufacturing Asphalt roofing and processing Asphalt/coal tar application-metal pipes Auto and light duty truck (surface coating) Boat manufacturing Brick and structural clay products manufacturing Cellulose manufacturing: Caroxymethylcellulose production Cellulose ethers production Cellulose food casing manufacturing Cellophane production Methylcellulose production Rayon production Ceramics manufacturing Clay minerals processing Coke by-product plants Coke oven: pushing, quenching, and battery stacks Combustion turbines Engine test facilities Flexible polyurethane foam fabrication operation Friction products manufacturing Fumed silica production Generic MACT: Carbon black production Cyanide chemicals mfg.a Ethylene production Spandex production Hydrochloric acid production Industrial/commercial/institutional boilers Integrated iron and steel manufacturing Iron and steel foundries Large appliance surface coating Leather tanning and finishing operations Lightweight aggregate manufacturing Lime manufacturing Mercury cell chlor-alkali plantsb Metal can surface coating Metal coil surface coating Metal furniture surface coating
© 2002 by CRC Press LLC
40 CFR 63 Subpart
LLLLL IIII VVVV
Tentative Proposal
Proposal Date
Tentative Final Date
To be delisted To be delisted 5/01 5/01 3/01 — 5/01
— — — — — 7/14/00
— — 5/02 5/02 2/02 4/01 2/02
—
8/28/00
4/01
5/01 5/01 To be delisted 9/00
5/02 5/02
YYYY
12/00 3/01 1/01
9/01 5/02 5/02
QQQQQ
1/01 3/01 —
12/01 2/02 4/01
CCCCC
YY
DDDDD FFFFF EEEEE NNNN TTTT AAAAA KKKK SSSS RRRR
2/01 3/01 12/00 3/01 — — 7/01 5/01 2/00 5/01 — 12/00
9/01
12/6/00
12/22/00 10/2/00 — — — 7/18/00
2/02 2/02 10/01 2/02 9/01 4/01 5/02 5/02 10/01 5/02 4/01 9/01
9588ch02 frame Page 27 Wednesday, September 5, 2001 9:40 PM
TABLE 2.8 (continued) Planned MACT Standards (as of March 6, 2001) Standard and Source Category 10-Year Bin Originally Due 11/15/00
40 CFR 63 Subpart
Misc. Metal parts surface coating Miscellaneous Organic NESHAP (MON): Alkyd resins Ammonium sulfate Benzyltrimethylammonium chloride Carbonyl sulfide Chelating agents Chlorinated paraffins Ethyllidene norbomene Explosives Hydrazine Maleic anhydride copolymers Paints, coatings, and adhesives OBPA/1,3-diisocyanate Photographic chemicals Phthalate plasticizers Polyester resins Polymerized vinylidene chloride Polymethyl methacrylate resins Polyvinyl acetate emulsions Polyvinyl alcohol Polyvinyl buryral Quaternary ammonium compounds Rubber chemicals Symmetrical tetrachloropyridine Municipal solid waste landfills Nutritional yeast manufacturing Organic liquids distribution (non-gasoline) Paint stripping operations Paper and other webs surface coating Petroleum refineries — catalytic cracking, catalytic reforming, and sulfur plant units a Petroleum solvent dry cleaning
MMMM FFFF
3/01 12/00
AAAA CCCC EEEE — JJJJ UUU
— — 1/01 5/01 — —
Plastic parts and products surface coating Plywood and composite wood products Polyvinyl chloride and copolymers production Primary copper smeltingb Primary magnesium refining Printing, coating, and dyeing of fabrics Reciprocating internal combustion engines Refractories manufacturing
PPPP ZZZ
© 2002 by CRC Press LLC
QQQ OOOO ZZZZ
Tentative Proposal
Potential delisting 3/01 12/00 — — 5/01 4/01 12/00 5/01
Proposal Date
Tentative Final Date 2/02 7/01
11/7/00 10/19/98 — — 9/13/00 9/11/98
9/01 12/00 10/01 5/02 6/01 9/00
12/8/00
12/01 12/01 2/01
4/20/98 —
11/00 3/02 4/02 11/01 5/02
9588ch02 frame Page 28 Wednesday, September 5, 2001 9:40 PM
TABLE 2.8 (continued) Planned MACT Standards (as of March 6, 2001) Standard and Source Category 10-Year Bin Originally Due 11/15/00
40 CFR 63 Subpart
Reinforced plastics composites productiona Rocket testing facilities Rubber tire manufacturing Semiconductor manufacturing Sewage sludge incinerators Site remediation Taconite iron ore processing Uranium hexafluoride production Vegetable oil production Wet formed fiberglass mat production Wood building products — surface coating
WWWW
a
XXXX BBBB GGGGG
GGGG HHHH QQQQ
Tentative Proposal
Proposal Date
12/00 3/01 — 5/01 Pending 5/01 5/01 5/01 — — 3/01
Tentative Final Date 8/01
10/18/00
5/26/00 5/26/00
5/02 8/01 5/02 3/02 3/02 5/02 4/01 4/01 12/01
Moved from 7-year bin.
pollutant removed, and considers both capital and operating costs. Also, the EPA promotes flexibility in an attempt to enhance cost effectiveness by incorporating emissions averaging between units into the standards. This allows facilities to choose between lower cost options while still reducing hazardous air pollutant emissions. While the technology-based MACT standards give a jump-start for action toward controlling HAPs, health-based standards have not been abandoned completely. Within 8 years after promulgation of the technology-based standards, the EPA is required to review the residual risk associated with hazardous air pollutants. If the EPA determines that the remaining emissions from a facility after application of technology standards still pose a health risk, the facility may have to reduce emissions further. This may yet cause the program to fall into the same difficulties that burdened the NESHAP program prior to the 1990 amendments. 2.2.3.3 Risk Management Plans A second feature of Title III is a program to prevent accidental releases of hazardous air pollutants and to reduce the risk of exposure to HAPs in the event of accidents. This is directly related to the accidental release of methyl isocyanate in Bhopal, India. The heart of the program is the requirement for “risk-management plans.” The program requires facilities to evaluate accidental release scenarios, mitigation action, and consequences and prepare a risk-management plan. While this may seem like common sense for any facility that handles hazardous materials, it was not always done well. Hence, the regulation is intended to ensure that all facilities review, understand, mitigate, and plan for accidental releases of the HAPs.
© 2002 by CRC Press LLC
9588ch02 frame Page 29 Wednesday, September 5, 2001 9:40 PM
Because many facilities used or stored hazardous chemicals, but did not emit them during normal operations, this provision brings those facilities under Clean Air Act regulations for the first time. It affects facilities that store or handle greater than threshold quantities of regulated substances from a list that is different from the list of HAPs for which MACT standards are promulgated.
2.2.4 TITLE IV: ACID DEPOSITION CONTROL Title IV is directed at SO2 and NOx emissions from utility power plants to control the precursors of acid deposition, which include acid rain, acid snow, and acid fog. Coal-fired utility power plants are the largest source of man-made SO2 emissions. The amendment repealed the requirement for a specified percentage reduction for new power plants and established a two-phase program for SO2 and NOx emission reductions. The amendments also established a market-based SO2 allowance-trading program to promote cost-effective reductions. Phase I, which became effective January 1, 1995, required 110 listed power plants of greater than 100 MW electrical capacity to reduce their emissions to a level equivalent to the product of an emissions rate of 2.5 lb of SO2/MMBTU by an average of their 1985–1987 fuel use. An additional 182 units joined Phase I of the program as substitution or compensating units, bringing the total number of affected units to 445. The success of the flexible program is reflected in that 1995 SO2 emissions were reduced by almost 40% below the required level overall. Phase I also specified NOx emission limits for tangentially fired boilers and dry-bottom, coal-fired boilers. Phase II became effective January 1, 2000. It affected all electric utility units greater than 25 MW electrical capacity. The SO2 emission rate was limited to 1.2 lb per million BTU. And a permanent cap of 8.9 million tons SO2 per year was established for the utility industry. Also, regulations for NOx control were promulgated in order to achieve a NOx reduction of 2 million tons per year. For the market-based SO2 allowance-trading program, each utility is allocated SO2 allowances by the EPA based on an emission rate of 1.2 lb SO2 per million Btu. An allowance is permission to emit 1 ton of SO2. Therefore, Phase II limits the number of available allowances in 2000 at 8.9 million. Each source must have sufficient allowances to cover its annual emissions. If a source’s emissions exceeds its allowance, it is subject to a $2000/ton excess emissions fee and a requirement to offset the excess emissions in the following year. Allowances are fully marketable commodities that may be bought, sold, and traded by any individual, corporation, or governing body, including brokers, municipalities, environmental groups, and private citizens. There have been cases of allowances being purchased and not used in order to keep those tons of SO2 from being emitted. Under this program, utilities that emit less than their allocated allowances may sell the excess allowances or bank them for later use. In addition to the allocated allowances, a certain number of allowances are made available for direct sale, by EPA-sponsored auction. New power plants after 1996 are not allocated allowances, and must obtain them from the market.
© 2002 by CRC Press LLC
9588ch02 frame Page 30 Wednesday, September 5, 2001 9:40 PM
250
200
150
100
50
0
FIGURE 2.2 SO2 allowance price history.
To keep track of SO2 emissions, stringent monitoring requirements have been developed. Of course, to measure the mass of SO2 emitted, both exhaust gas flow and pollutant concentration are required. Daily calibration and record-keeping requirements must be met. Initially, the program was met with some skepticism and cynicism. Some opponents claimed that utilities were given the ability to “buy the right to pollute.” However, the program has been a significant success. Through the end of 1999, over 80 million allowances have been traded, with approximately 62% of the trades between power plants within organizations, and 38% between organizations. The price of allowances, displayed in Figure 2.2, has fluctuated between $70 and $215, which is much lower than the anticipated $1500 value as the program was being planned. The General Accounting Office estimated that the allowance trading system saves as much as $3 billion per year — over 50% — compared with a command and control approach typical of previous environmental protection programs.
2.2.5 TITLE V: OPERATING PERMITS The concept of an operating permit is to detail in one place a description of a major emission source, how it operates, the effect of operations on emissions, and all air emissions permit limitations and obligations. This would provide understanding and clarity for both the operator and the regulatory agency, which would aid in ensuring compliance. Currently, a source’s pollution control obligations may be scattered throughout numerous hard-to-find provisions of state and federal regulations. The permit program is intended to ensure that all of a source’s air pollutant obligations are being met, and that the source files periodic reports identifying the extent to which it has complied with those obligations. The EPA struggled with a variety of monitoring programs that would ensure compliance with permit obligations. Initially, the Compliance Assurance Monitoring (CAM) rule was proposed, which emphasized continuous measurement of either © 2002 by CRC Press LLC
9588ch02 frame Page 31 Wednesday, September 5, 2001 9:40 PM
pollutants or surrogate operating parameters that could be linked to pollutants. Eventually the monitoring requirements were relaxed into Periodic Monitoring, which would be less stringent than continuous monitoring. Title V also authorizes regulatory agencies to collect emission fees based on the quantity of emissions. This provision is intended to augment the resources for agencies to carry out enforcement of the Clean Air Act, as well as to provide some incentive for facilities to reduce emissions.
2.2.6 TITLE VI: STRATOSPHERIC OZONE PROTECTION The law requires a complete phase-out of chlorofluorcarbons (CFCs) and bromochlorofluorocarbons (i.e., halons) with interim reductions and some related changes to the existing Montreal Protocol, revised in June 1990. Under these provisions, EPA must list all regulated substances along with their ozone depletion potential, atmospheric lifetimes, and global warming potentials within 60 days of enactment. EPA must ensure that Class I chemicals are phased out on a schedule similar to that specified in the Montreal Protocol — CFCs, halons, and carbon tetrachloride by 2000; methylchloroform by 2002 — but with more stringent interim reductions. Class II chemicals (HCFCs) will be phased out by 2030. The law also requires EPA to publish a list of safe and unsafe substitutes for Class I and II chemicals and to ban the use of unsafe substitutes.
2.2.7 TITLE VII: ENFORCEMENT The 1990 Amendments granted the EPA new authority to issue administrative penalty orders, and enhanced civil judicial penalties. Criminal penalties for knowing violations are upgraded from misdemeanors to felonies. Knowingly releasing a hazardous air pollutant that places another person in imminent danger of death or serious injury can result in a fine of up to $1,000,000 for organizations, and imprisonment of up to 15 years. Negligent release of a HAP is punishable by up to 1 year in prison. Making a false material statement, representation, or certification, or falsifying, tampering with, or failing to install monitoring devices can result in 2 years in prison. Company officials must certify either compliance or acknowledgment of being out of compliance with regulations. If out of compliance, there must be a plan in place to achieve compliance. Certification adds personal liability and causes many managers to be much more concerned about compliance than they had been in the past. Administrative penalties can result in fines of up to $25,000 per day, to a maximum of $200,000. When assessing penalties, EPA is required to consider the size of the business, compliance history, duration of the violation, good faith efforts to comply, payment of penalties previously assessed for the same violation, the economic advantage to the company for noncompliance, and the seriousness of the violation. An added legal right now allows citizens to seek penalties against violators. Penalties are placed in a U.S. Treasury fund to be used by the EPA for compliance and enforcement activities. An award of up to $10,000 also was established for information leading to criminal conviction or administrative penalties for violations © 2002 by CRC Press LLC
9588ch02 frame Page 32 Wednesday, September 5, 2001 9:40 PM
of the hazardous air pollutant, acid deposition, operating permit, or stratospheric ozone programs.
2.2.8 TITLE VIII: MISCELLANEOUS PROVISIONS Among several other miscellaneous provisions, Title VIII requires that EPA review the emission factors that are used to estimate quantities of CO, VOC, and NOx emissions every 3 years. In addition, any person may demonstrate, after appropriate public participation, and request approval for improved emission estimating techniques.
2.2.9 TITLE IX: RESEARCH Title IX provides federal funding for research programs including monitoring and modeling, health effects, ecological effects, accidental releases, pollution prevention, emissions control, acid rain, and alternative motor vehicle fuels. Ecosystem studies must be conducted for the effects of air pollutants on water quality, forests, and biological diversity.
2.2.10 TITLE X: DISADVANTAGED BUSINESS Title X requires that at least 10% of federal research funds be made available to disadvantaged businesses.
2.2.11 TITLE XI: EMPLOYMENT TRANSITION ASSISTANCE Title XI provides additional unemployment benefits through the Job Training Partnership Act for workers laid off as a consequence of compliance with the Clean Air Act.
REFERENCES 1. Chambers, A., Fanning the flames, Power Eng., 104(1), 16, 2000. 2. Boubel, R. W., Fox, D. L., Turner, D. B., and Stern, A. C., Fundamentals of Air Pollution, 3rd ed., Academic Press, San Diego, 1994, 395. 3. General Overview of the CAAA, www.epa.gov/ttn/oarpg/gen/overview.txt, EPA OAQPS Technology Transfer Network, 1993. 4. Coffin, D. L., Blommer, E. J., Gardner, D. E., and Holzman, R. S., Effects of air pollution on alteration of susceptibility to pulmonary infection, in Proc. Third Ann. Conf. Atmospheric Contaminants in Confined Spaces, Aerospace Medical Research Laboratory, Wright Patterson Air Force Base, Dayton, OH, 1968, 71. 5. Whitman, EPA v. American Trucking Association, Inc., U.S. Supreme Court, 99-1257. 6. National emission standards for hazardous air pollutants: revision of source category list and schedule for standards under Section 112 of the Clean Air Act, Fed. Register, 64, (222), Nov. 18, 1999. 7. Sierra Club v. Browner, D.C. District Court, 93-0124.
© 2002 by CRC Press LLC
9588ch03 frame Page 33 Wednesday, September 5, 2001 9:42 PM
3
Air Permits for New Source
A facility that proposes to add or modify a source of air pollution may be required to obtain an approved air permit before starting construction of the new source. Local regulations define the permit requirements for small sources. Federal regulations define the air permit application requirements for major stationary sources. The process for evaluation and approval of a new major source permit application is called New Source Review (NSR). It covers permits for new major sources in both attainment, called Prevention of Significant Deterioration or PSD permits, and Non-Attainment Area (NAA) permits. Although available for over 10 years in “Draft” form, EPA’s New Source Review Workshop Manual contains excellent guidance for preparing an air permit application.1 Permit requirements are specific for each pollutant, including each criteria pollutant, precursors to tropospheric ozone (i.e., VOCs), and each hazardous air pollutant. Depending on the quantity of each pollutant emitted, each may be subject to a local regulation or to federal regulations for new source review.
3.1 ELEMENTS OF A PERMIT APPLICATION In general, an air permit application will include the following: • • • • • • •
Facility information Description of the new source of air pollution Estimated quantities of each pollutant Applicability determination (if a major source is being considered) Description of air pollution control devices and justification for selection Effect on ambient air pollutant concentration Other impacts
Local regulatory agencies may provide forms that detail the required information explicitly and succinctly. A major new source review requires a large amount of discussion, so simple forms are not appropriate for the wide variety of circumstances and the long discussions of pertinent subjects. Instead, the required elements of the permit application are presented in chapters of a document with appendices for supporting information (e.g., detailed dispersion modeling output). Although local requirements for small sources may not require as much detailed information as major sources, a similar evaluation process often is used. Many local agencies require a Best Available Control Technology (BACT) analysis for selection of controls for small sources styled in the same manner and using the same approach as required for major sources.
© 2002 by CRC Press LLC
9588ch03 frame Page 34 Wednesday, September 5, 2001 9:42 PM
Interestingly, a permit application for a new major source in a non-attainment area may require less information that a PSD permit application in an attainment area. The reason is because some of the information, such as cost effectiveness of control equipment and PSD increment consumption, is moot. Control equipment for new sources in a non-attainment area must meet Lowest Achievable Emission Rate (LAER), where cost effectiveness is not a consideration.
3.1.1 APPLICABILITY Applicability must be evaluated to determine which regulations apply to a new source. Three basic criteria are considered: (1) whether the source is sufficiently large to be considered a “major” stationary source; (2) if the source is in an attainment area; and (3) if “significant” amounts of specific pollutants will be emitted. A stationary source is considered to be “major” if the “potential to emit” exceeds the specified major source threshold. The threshold for industrial categories listed in Table 3.1 is 100 tons per year of any regulated pollutant except the listed hazardous air pollutants. For all other industrial categories, the threshold is 250 tons per year. However, as discussed in Chapter 2, the emission threshold for a “major” source is reduced in ozone non-attainment areas, bringing smaller facilities into the scrutiny of federal new source review requirements in those areas. 3.1.1.1 Potential to Emit Potential to emit (PTE) is the amount of pollution that a facility is capable of emitting at the maximum design capacity of the facility, except as constrained by federally enforceable conditions. The PTE is determined separately for each pollutant. Federally enforceable conditions are permit restrictions that can be verified, such as installed air pollution control equipment at prescribed efficiency, restrictions on hours of operation, and restrictions on the raw materials or fuel that is burned, stored, or processed. The facility must be able to show continual compliance (or noncompliance) with each limitation through testing, monitoring, and/or recordkeeping. 3.1.1.2 Fugitive Emissions Fugitive emissions, to the extent that they are quantifiable, are included in the PTE and in subsequent impact analysis. Fugitive emissions are emissions that cannot reasonably be collected and pass through a stack, vent, or similar opening. Examples include particulate matter from coal piles, roads, and quarries, and VOC emissions from leaking valves, flanges, and pump seals at refineries and organic chemical plants. 3.1.1.3 Secondary Emissions Secondary emissions are not considered as part of the potential to emit. Secondary emissions are associated with the source, but are not emitted from the source itself. For example, a production increase from a new cement plant could require increased emissions at the adjacent quarry owned by another company. Increased secondary © 2002 by CRC Press LLC
9588ch03 frame Page 35 Wednesday, September 5, 2001 9:42 PM
TABLE 3.1 PSD Source Categories with Major Source Threshold of 100 tpy Fossil-fuel-fired steam electric plants of more than 250 million BTU/h heat input Coal cleaning plants (with thermal dryers) Kraft pulp mills Portland cement plants Primary zinc smelters Iron and steel mill plants Primary aluminum ore reduction plants Primary copper smelters Municipal incinerators capable of charging more than 250 tons of refuse per day Hydrofluoric acid plants Sulfuric acid plants Nitric acid plants Petroleum refineries Lime plants Phosphate-rock processing plants Coke oven batteries Sulfur recovery plants Carbon black plants (furnace plants) Primary lead smelters Fuel conversion plants Sintering plants Secondary metal production plants Chemical process plants Fossil fuel boilers (or combinations thereof) totaling more than 250 million BTU/h heat input Petroleum storage and transfer units with a total storage capacity exceeding 300,000 barrels Taconite ore processing plants Glass fiber processing plants Charcoal production plants
emissions at the quarry would not be included in the cement plant’s PTE. However, if they are specific, well-defined, quantifiable, and impact the same general area as the cement plant, they would be considered in the discussion of the cement plant’s ambient impacts analysis.
3.1.2 SIGNIFICANT EMISSION RATES The significant emission rate thresholds, often called the “PSD trigger,” for federal NSR for specific pollutants are listed in Table 3.2. In attainment areas, any new or modified source emissions at a major source facility that increases the PTE of any of these pollutants by the significant emission rate triggers the requirement for a PSD permit. There is a second criterion for significant emission threshold. If any new major stationary source is constructed within 10 km of a Class I area and if the potential emissions would increase the 24-hour average concentration of any regulated air pollutant by 1.0 µg/m3 or more, then a PSD review is triggered. © 2002 by CRC Press LLC
9588ch03 frame Page 36 Wednesday, September 5, 2001 9:42 PM
TABLE 3.2 Significant Emission Rates for Federal New Source Review Pollutant Carbon monoxide Nitrogen oxides (all oxides of nitrogen) Sulfur dioxide Particulate matter PM10 VOC (ozone precursor) Lead Asbestos Beryllium Mercury Vinyl chloride Fluorides Sulfuric acid mist Hydrogen sulfide Total reduced sulfur compounds including H2S
Significant Emission Rate (tons per year) 100 40 40 25 15 40 0.6 0.007 0.0004 0.1 1 3 7 10 10
3.1.3 MODIFICATION A “modification” is generally a physical change or a change in the method of operation that results in an increase of air pollutant emissions, and a NSR for a modification is treated in the same way as for a new source. Existing sources that are not modified generally are “grandfathered” with no change in their existing pollution controls, although existing sources in nonattainment areas may be required to install Reasonably Available Control Technology (RACT) for criteria pollutants, and existing sources of hazardous air pollutants may be regulated by the Maximum Achievable Control Technology (MACT) standards for hazardous air pollutants as discussed in the previous chapter. A modification is subject to PSD review only if the existing source is a “major” stationary source and if the net emissions increase of any pollutant emitted by the source is equal to or greater than the “significant emission rate.” The regulations do not define “physical change” or “change in the method of operation” precisely. However, they specifically exclude certain activities, including: • Routine maintenance, repair, and replacement • A fuel switch due to an order under the Energy Supply and Environmental Coordination Act of 1974 (or any superceding legislation) or due to a natural gas curtailment plan under the Federal Power Act • A fuel switch due to an order or rule under section 125 of the CAA • A switch at a steam generating unit to a fuel derived in whole or in part from municipal solid waste
© 2002 by CRC Press LLC
9588ch03 frame Page 37 Wednesday, September 5, 2001 9:42 PM
• A switch to a fuel or raw material which (a) the source was capable of accommodating before January 6, 1975, so long as the switch would not be prohibited by any federally enforceable permit condition established after that date under a federally approved SIP (including any PSD permit condition) or a federal PSD permit, or (b) the source is approved to make under a PSD permit • Any increase in the hours or rate of operation of a source, so long as the increase would not be prohibited by any federally enforceable permit condition established after January 6, 1975 under a federally approved SIP (including any PSD permit condition) or a federal PSD permit • A change in ownership of a stationary source
3.1.4 EMISSIONS NETTING In determining the change in emissions that result from a modification at an existing source, other contemporaneous increases and decreases can be considered. A facility may increase NOx emissions with one project, and decrease NOx emissions at nearly the same time with another project. The net NOx emissions may be less than the significant emission rate for NOx, and the projects could “net out of PSD.” Avoiding the scrutiny of a PSD permit approval process may have advantages for the facility, including different agency jurisdiction for the review, fewer agencies involved in the process, and no PSD increment evaluation. The advantage to the environment is the incentive for reducing emissions while allowing improvements at existing facilities to proceed. The net emissions change equals the emissions increases associated with the proposed modification minus source-wide creditable contemporaneous emissions decreases plus source-wide creditable contemporaneous emissions increases. The increases and decreases are changes in actual emissions (not permitted or potential emissions). They must be at the same major source facility. They cannot be traded between facilities. And the netting equation is pollutant specific. The contemporaneous time period is defined by federal regulations as 5 years before the date that construction on the proposed modification is expected to commence. Changes older than the contemporaneous period are not considered. Many states to which jurisdiction for the PSD program has been delegated by the EPA have developed regulations with different time periods for the definition of contemporaneous. Where approved by the EPA, these time periods are used. Establishing the exact dates for the contemporaneous time period can be very important and a bit difficult to determine. Since the date that construction will commence is unknown when the permit application is prepared and reviewed, the scheduled date may be used. The date of increases and decreases is set when the changed emission unit becomes operational, which may be after a reasonable shakedown period that does not exceed 180 days. 3.1.4.1 Netting Example A major source proposes a modification to its facility that would result increasing the potential to emit by 35 tons per year (tpy) NOx, 80 tpy SO2, and 25 tpy particulate
© 2002 by CRC Press LLC
9588ch03 frame Page 38 Wednesday, September 5, 2001 9:42 PM
matter less than 10 microns (PM10). Two years ago, the facility incorporated a smaller modification that increased the potential to emit by 30 tpy NOx, 15 tpy SO2, and 5 tpy PM10, all of which were less than the significant amounts that would trigger a PSD review for that modification. Three years ago, the facility made a change that decreased actual emissions by 10 tpy NOx, 50 tpy SO2, and 20 tpy PM10. The facility applied for and received emission reduction credits for the decreased emissions. Since the proposed increase in NOx emissions of 35 tpy is less than the significant amount of 40 tpy, a PSD review for NOx is not required. The net increase in potential SO2 emissions is 45 tpy (+80 +15 –50), which is greater than the PSD trigger and a PSD review for SO2 is required. The net increase in potential particulate matter emissions is +10 tpy (+25 +5 –20), which is less than the PSD trigger and a PSD review for PM10 is not required.
3.2 BEST AVAILABLE CONTROL TECHNOLOGY The Federal New Source Review program requires that Best Available Control Technology (BACT) be applied to major new sources and major modifications in attainment areas. Many local agencies also require that BACT be applied to smaller new sources of air pollution. Often the selection of control technology does not depend on whether a PSD review is triggered because the same control technology will be required in any case. BACT is a technology-based standard that can be met by available technology. Typically it is specified in an air permit as a maximum emission rate or concentration that can be monitored and verified. Frequently one will read or hear a vendor’s advertisement that their technology is BACT for a type of emission source. More precisely, they mean that their technology usually is accepted by permitting agencies as the technology that will be used to control emissions to a specified limit. BACT is determined on a case-by-case basis as the technology that will provide the maximum degree of reduction taking into account energy, environmental, and economic impacts and other costs. The permit applicant proposes BACT for the proposed project and provides a detailed BACT analysis to support their proposal. The permitting agency reviews the permit application for completeness and accuracy, and may approve the proposed technology and emission limitation, reject it, or request more information. BACT may be differentiated from other acronymed technologies. Reasonable Available Control Technology (RACT) applies to retrofits for existing sources in nonattainment areas while BACT applies to new and modified sources. Lowest Achievable Emission Rate (LAER) applies to new and modified sources in nonattainment areas while BACT applies to areas that are in attainment of the NAAQS. Maximum Achievable Control Technology (MACT) applies to hazardous air pollutants from industrial point sources while BACT applies to criteria pollutants. Generally Available Control Technology (GACT) applies to hazardous air pollutants from area sources, which is any stationary source of hazardous air pollutants that is not a major source.
© 2002 by CRC Press LLC
9588ch03 frame Page 39 Wednesday, September 5, 2001 9:42 PM
Some local agencies adopt additional distinctions for control technologies. Best Available Retrofit Control Technology (BARCT) is used in California for existing sources in nonattainment areas, just like RACT. It may be difficult to distinguish between BARCT and RACT, although both are based on judgment resulting from an evaluation of the source and situation, and BARCT is sometimes more stringent than RACT for a given source type.2 Toxic Best Available Control Technology (T-BACT) is used by some local agencies for new sources of toxic air pollutants. Cost effectiveness is a very important part of BACT, whereas it is not considered when selecting the LAER for new sources in NAAQS non-attainment areas. One also frequently anticipates permitting agencies to be looking for a specific cost effectiveness, expressed as dollars per ton of pollutant removed, when they accept BACT. Agencies, meanwhile, are reluctant to establish a firm threshold for cost effectiveness, because a BACT analysis is more than a simple economic evaluation and needs to take other criteria into account. This makes it difficult for an applicant to judge what an agency considers to be cost effective. Precedent, both locally and nationally, can be used as a guide. The EPA has adopted a “top down” methodology for determining BACT. This means that the control technology with the highest degree of pollutant reduction must be evaluated first. If that technology meets all of the criteria for feasibility, cost effectiveness, air quality impacts, and other impacts, it is determined to be BACT for the proposed new source and the analysis ends. If not, the next most effective control technology is evaluated for BACT. The “top down” approach is rigorous, and drives using the highest reduction technology that is considered costeffective by the agency rather than more cost effective compromises that would be desired by an applicant. As a minimum level, BACT must at least meet the emission limitations of New Source Performance Standards (NSPS). Established NSPS have already been based on a thorough technology and economic evaluation. But as control technology improves, BACT may become more stringent than NSPS.
3.2.1 STEP 1: IDENTIFY CONTROL TECHNOLOGIES First, potential control technologies are identified. The potential technologies include those that are used outside of the U.S. and those that are used for similar emission sources. Innovative control technologies may be included, but if a technology has not been commercially demonstrated and if it is not commercially available, then it is not considered to be a potential for “available” control technology. This step takes some research. As a minimum, research should include EPA’s Office of Air Quality Planning and Standards Technology Transfer Network Clean Air Technology Center RACT/BACT/LAER Clearinghouse . Agencies use this database to post permit application emission limits, technologies, and restrictions for other agencies and applicants to use for just this purpose. Technical books and journals are another common source of technology information. Internet searches now can be quite valuable. Control equipment vendors often are invaluable sources of information, although one must bear in mind their vested
© 2002 by CRC Press LLC
9588ch03 frame Page 40 Wednesday, September 5, 2001 9:42 PM
interest in selling their equipment. Environmental consultants often are hired to prepare permit applications because of their prior knowledge of control technologies and permit application requirements. Less common, but acceptable, sources of information include technical conference reports, seminars, and newsletters. Agencies typically expect a reasonably complete list, but it does not have to be exhaustive. Agency personnel use their own knowledge of the industry to check for completeness, and will request additional information for a potential technology if they believe a good possibility has been left out.
3.2.2 STEP 2: ELIMINATE TECHNICALLY INFEASIBLE OPTIONS Some of the potential control technologies may not work in the specific application being proposed. To be technically feasible, the control technology must be available and applicable to the source. Technical infeasibility may be based on physical, chemical, or engineering principles. Technical judgment must be used by the applicant and the reviewing agency in determining whether a control technology is applicable to the specific source. For example, while modifying a process heater, low-NOx burners might not be able to be retrofit into the heater due to its configuration. The longer flame length produced by low-NOx burners may impinge on the back wall of the heater. Demonstrating unresolvable technical difficulty due to the size of the unit, location of the proposed site, or operating problems related to specific circumstances could show technical infeasibility. However, when the resolution of technical difficulties is a matter of cost, the technology should be considered technically feasible, and let the economic evaluation determine if the cost is reasonable. There may be instances where huge cost can solve many problems. Judgment should be exercised to avoid wasteful effort in detailed economic evaluations that don’t stand a chance of being reasonable.
3.2.3 STEP 3: RANK REMAINING OPTIONS
BY
CONTROL EFFECTIVENESS
All remaining control technologies that are not eliminated during Step 2 are ranked in order of control effectiveness for the pollutant under review. While seemingly straightforward, two key issues must be addressed in this step. The first is ensuring that a comparable basis is used for emission reduction capability. Calculating potential emissions on a basis of mass per unit production, i.e., pounds SO2 per million BTU heat input, can help. A more difficult problem arises for control techniques that can operate over a wide range of emission performance levels, depending on factors such as size (e.g., a large electrostatic precipitator vs. a small one) and operating parameters (e.g., scrubber recirculation rate and reagent concentration). Every possible level of efficiency does not have to be analyzed. Again, judgment is required. Recent regulatory decisions and performance data can help identify practical levels of control. This reduces the need to analyze extremely high levels in the range of control. By spending a huge amount of money and installing a huge electrostatic precipitator, an extremely high particulate removal efficiency is theoretically possible. However, as discussed
© 2002 by CRC Press LLC
9588ch03 frame Page 41 Wednesday, September 5, 2001 9:42 PM
in Chapter 24, there are practical limitations to theoretical performance. Demonstrated performance is critical to the evaluation of available technology. Also, it generally is presumed that demonstrated levels of control can be achieved unless there are source-specific factors that limit the effectiveness of the technology. This eliminates the need to analyze lower levels of a range of control.
3.2.4 STEP 4: EVALUATE CONTROL TECHNOLOGIES OF CONTROL EFFECTIVENESS
IN
ORDER
Starting with the feasible technology having the highest pollutant removal performance, the technology is evaluated for energy impacts, environmental impacts (other than air quality, which will be analyzed in detail in another section of a new source permit application), and economic impacts. Both adverse and beneficial effects should be discussed, and supporting information should be presented. 3.2.4.1 Energy Impacts Many control technologies either consume or produce energy or change the amount of energy that is produced by the process. Thermal oxidation of volatile organics in a concentrated gas stream may be an example of energy production if that energy can be recovered and put to use. Energy and energy conservation is considered by the government to be important to the economy of the nation, and the energy analysis assures that energy has been considered. However, quantitative thresholds for energy impacts have not been established, so it is difficult to reject a technology based on energy alone. There may be a circumstance where the required energy is not available at the proposed source. The cost of energy will be considered separately in the economic evaluation. The energy evaluation should consider only direct energy consumption by the control technology. Indirect energy consumption that should not be considered includes the energy required to produce the raw materials for the control technology (e.g., the heat required to produce lime from limestone) and for transportation of raw materials and byproducts. 3.2.4.2 Environmental Impacts This section of the BACT analysis provides information about environmental impacts other than air quality. A detailed discussion of pollutant concentration in ambient air must be provided separately in the air permit application. This discussion of environmental impacts includes topics such as creation of solid or hazardous waste (e.g., as byproducts of the control technology or as spent catalyst), wastewater, excess water use in an area with inadequate supply, emissions of unregulated air pollutants, and destruction of critical habitat. It also contains an evaluation of impacts on visibility. Both positive and negative impacts should be discussed. That a control technology generates liquid or solid waste or has other environmental impacts does not necessarily eliminate the technology as BACT. Rather, if the other impacts create significant environmental problems, there may be a basis
© 2002 by CRC Press LLC
9588ch03 frame Page 42 Wednesday, September 5, 2001 9:42 PM
for elimination. Site-specific and local issues may define what problems are considered to be “significant.” 3.2.4.3 Economic Impacts and Cost Effectiveness The section on economic impacts and cost effectiveness tends to be more objective than the energy and environmental impacts sections because costs are quantified in terms of dollars spent per ton of pollutant reduced. The focus is the cost of control, not the economic situation of the facility. The primary factors required to calculate cost effectiveness, defined as dollars per ton of pollutant reduced, are the emission rate, the control effectiveness, the annualized capital cost of the control equipment, and the operating cost of the control equipment. With these factors, the cost effectiveness is simply the annualized capital and operating costs divided by the amount of pollution controlled by the technology in 1 year. Estimating and annualizing capital costs are discussed in Chapter 7. Total capital cost includes equipment, engineering, construction, and startup. Annual operating costs include operating, supervisory, and maintenance labor, maintenance materials and parts, reagents, utilities, overhead and administration, property tax, and insurance. In addition to the overall cost effectiveness for a control technology, the incremental cost effectiveness between dominant control options can be presented. The incremental cost effectiveness is the difference in cost between two dominant technologies divided by the difference in the pollution emission rates after applying these two technologies. An extraordinarily high incremental cost effectiveness can be used as justification that a control technology having only slightly higher removal efficiency than the next technology, but which has significantly higher cost, is not cost effective. The incremental cost effectiveness approach sometimes can be used to establish the practical limits for technologies with variable removal efficiency. For example, an electrostatic precipitator with 98% removal efficiency may be considered by an applicant to be cost effective. But to achieve 99.5% efficiency, a much larger and more expensive precipitator would be required. The large additional cost for a small improvement in efficiency is not cost effective.
3.2.5 STEP 5: SELECT BACT Step 4 is repeated for each technology in order of the control effectiveness established in Step 3 until one of the technologies is not eliminated by the evaluation. The most effective level of control that is not eliminated by the evaluation is proposed by the applicant to be BACT. It is not necessary to continue evaluating technologies that have lower control effectiveness. The permitting agency will review the application for completeness and accuracy, and is responsible for assuring that all pertinent issues are addressed before approving the application. The ultimate BACT decision is made by the agency after public comment is solicited and public review is held and comments are addressed.
© 2002 by CRC Press LLC
9588ch03 frame Page 43 Wednesday, September 5, 2001 9:42 PM
3.3 AIR QUALITY ANALYSIS Each PSD source or modification must perform an air quality analysis to demonstrate that its new pollutant emissions would not violate either the applicable NAAQS or the applicable PSD increment. To determine if a new industrial source of air pollution can be established in any area, the projected increase in ambient pollutant concentration must be determined using dispersion modeling. If the proposed source is large and if there is any doubt that either the allowed increment could be exceeded or that the NAAQS could be approached, air permitting agencies may require up to 2 years of ambient air monitoring to establish accurate background concentrations. Additional monitoring may be required after the source starts up to ensure that modeling calculations did not underpredict the effect of the new source.
3.3.1 PRELIMINARY ANALYSIS A preliminary dispersion modeling analysis is first performed to: (1) determine whether the applicant can forego further air quality analyses for a particular pollutant; (2) allow the applicant to be exempted from ambient monitoring data requirements; and (3) determine the impact area within which a full impact analysis must be carried out. The levels of significance for air quality impacts in Class II areas are listed in Table 3.3. If a proposed source is located within 100 km of a Class I area, an impact of 1 µg/m3 on a 24-h basis is significant. If the projected increase in pollutant concentration is less than the significance level for the appropriate time averaging period, then it is considered “insignificant,” and an evaluation of PSD increment consumption is not required. Also, the available increment is not reduced by projects having an insignificant impact, so future PSD increment analyses can neglect these small projects. Sometimes a simple, conservative screening model can be used to quickly demonstrate that a new source is insignificant. The SCREEN model can be downloaded from the EPA OAQPS Technology Transfer network web page. This model
TABLE 3.3 Significance Levels for Air Quality Impacts in Class II Areas Time Averaging Period Pollutant SO2 TSP PM10 NOx CO O3 a
Annual 1 1 1 1
µg/m3 µg/m3 µg/m3 µg/m3 — —
24-h
8-h
3-h
1-h
5 µg/m3 5 µg/m3 5 µg/m3 — — —
— — — — 500 µg/m3 —
25 µg/m3 — — —
— — — — 2000 µg/m3 —a
—
No significant ambient impact concentration has been established. Instead, any net emissions increase of 100 tons per year of VOC subject to PSD would be required to perform an ambient impact analysis.
© 2002 by CRC Press LLC
9588ch03 frame Page 44 Wednesday, September 5, 2001 9:42 PM
applies conservative default meteorological conditions so meteorological data input is not required. As a result, it calculates conservatively high ambient pollutant concentrations. A more complex model that uses local meteorological data can be used to calculate the impact of a source on local ambient air quality, with more realistic results than are obtained from a screening model. The ISCST and ISCLT (Industrial Source Complex Short Term and Long Term) models often are used. Many commercial pollutant dispersion models use the ISC model as the base for the calculations and add input/output routines to make them user friendly and to display results attractively.
3.3.2 FULL ANALYSIS A full impact analysis is required when the estimated increased in ambient pollutant concentration exceeds the prescribed significant ambient impact level. The full analysis expands the scope of the dispersion modeling to include existing sources and the secondary emissions from residential, commercial, and industrial growth that accompanies the new activity at the new source or modification. The full impact analysis is used to project ambient pollutant concentrations against which the applicable NAAQS and PSD increments are compared.
3.4 NSR REFORM In July, 1996, the EPA proposed revisions to the NSR program. The goals of the reform were to reduce the regulatory burden and to streamline the NSR permitting process. According to the EPA, the proposed revisions would reduce the number and types of activities at a source that would be subject to major NSR review, provide state agencies with more flexibility, encourage the use of pollution prevention and innovative technologies, and address concerns related to permitting sources near Class I areas. However, not everyone agrees with the EPA’s assessment of the value of the reforms. Significant debate delayed adoption of the 1996 proposal. A major issue has been the applicability of major NSR to modifications of existing sources.3 With the new administration, the direction of NSR reform may undergo significant change.
RERERENCES 1. New Source Review Workshop Manual, U.S. Environmental Protection Agency, Draft, October 1990. 2. Leonard, R. L., Air Quality Permitting, Lewis Publishers, Boca Raton, 1997, 68. 3. Evans, B. and Weiss, K., Summary of progress on EPA’s NSR reform initiative, EM, 27, June 2000.
© 2002 by CRC Press LLC
9588ch04 frame Page 45 Wednesday, September 5, 2001 9:44 PM
4
Atmospheric Diffusion Modeling for PSD Permit Regulations
4.1 INTRODUCTION — METEOROLOGICAL BACKGROUND Reduction of ground-level concentrations from a point source can be accomplished by elevation of the point of emission above the ground level. The chimney has long been used to accomplish the task of getting the smoke from fires out of the house and above the inhabitants’ heads. Unfortunately meteorological conditions have not cooperated fully, and, thus, the smoke from chimneys does not always rise up and out of the immediate neighborhood of the emission. To overcome this difficulty for large sources where steam is produced, for example, such as power plants and space heating boiler facilities, taller and taller stacks have been built. These tall stacks do not remove the pollution from the atmosphere, but they do aid in reducing groundlevel concentrations to a value low enough so that harmful or damaging effects are minimized in the vicinity of the source.
4.1.1 INVERSIONS Inversions are the principal meteorological factor present when air pollution episodes are observed. They can be classified according to the method of formation and according to the height of the base, the thickness, and the intensity. An inversion may be based at the surface or in the upper air. 4.1.1.1 Surface or Radiation Inversions A surface inversion usually occurs on clear nights with low wind speed. In this situation the ground cools rapidly due to the prevalence of long-wave radiation to the outer atmosphere. Other heat transfer components are negligible which means the surface of the earth is cooling. The surface air becomes cooler than the air above it, and vertical air flow is halted. In the morning the sun warms the surface of the earth, and the breakup of the inversion is rapid. Smoke plumes from stacks are quite often trapped in the radiation inversion layer at night and then brought to the ground in a fumigation during morning hours. The result is high ground-level concentration. 4.1.1.2 Evaporation Inversion After a summer shower or over an irrigated field, heat is required as the water evaporates. The result is a transfer of heat downward, cooling the upper air by convection and forming an evaporation inversion.
© 2002 by CRC Press LLC
9588ch04 frame Page 46 Wednesday, September 5, 2001 9:44 PM
4.1.1.3 Advection Inversion An advection inversion forms when warm air blows across a cooler surface. The cooling of the air may be sufficient to produce fog. When a sea breeze occurs from open water to land, an inversion may move inland, and a continuous fumigation may occur during the daytime. 4.1.1.4 Subsidence Inversion In Los Angeles, the typical inversion is based in the upper air. This inversion results from an almost permanent high pressure area centered over the north Pacific Ocean near the city. The axis of this high is inclined in such a way that air reaching the California coast is slowly descending or subsiding. During the subsidence, the air compresses and becomes warmer, forming an upper-air inversion. As the cooler sea breeze blows over the surface, the temperature difference increases, and the inversion is intensified. It might be expected that the sea breeze would break up the inversion but this is not the case. The sea breeze serves only to raise and lower the altitude of the upper air inversion.
4.1.2 THE DIURNAL CYCLE On top of the general circulation a daily, or 24-hour cycle, referred to as the diurnal cycle is superimposed. The diurnal cycle is highly influenced by radiation from the sun. When the sun appears in the morning, it heats the earth by radiation, and the surface of the earth becomes warmer than the air above it. This causes the air immediately next to the earth to be warmed by convection. The warmer air tends to rise and creates thermal convection currents in the atmosphere. These are the thermals which birds and glider pilots seek out, and which allow them to soar and rise to great altitudes in the sky. On a clear night, a process occurs which is the reverse of that described above. The ground radiates its heat to the blackness of space, so that the ground cools off faster than the air. Convection heat transfer between the lower air layer and the ground causes the air close to the ground to become cooler than the air above, and a radiation inversion forms. Energy lost by the surface air is only slowly replaced, and a calm may develop. These convection currents set up by the effect of radiant heat from the sun tend to add or subtract from the longer-term mixing turbulence created by the weather fronts. Thus, the wind we are most familiar with, the wind close to the earth’s surface, tends to increase in the daytime and to die down at night. There are significant diurnal differences in the temperature profiles encountered in a rural atmosphere and those in an urban atmosphere. On a clear sunny day in rural areas, a late afternoon normal but smooth temperature profile with temperatures decreasing with altitude usually develops. As the sun goes down, the ground begins to radiate heat to the outer atmosphere, and a radiation inversion begins to build up near the ground. Finally by late evening, a dog-leg shaped inversion is firmly established and remains until the sun rises in the early morning. As the sun begins to warm the ground, the inversion is broken from the ground up, and the temperature © 2002 by CRC Press LLC
9588ch04 frame Page 47 Wednesday, September 5, 2001 9:44 PM
profile becomes “z” shaped. Smoke plumes emitted into the atmosphere under the late evening inversion tend to become trapped. Since vertical mixing is very poor, these plumes remain contained in very well-defined layers and can be readily observed as they meander downwind in what is called a fanning fashion. In the early morning as the inversion breaks up, the top of the thickening normally negative temperature gradient will encounter the bottom edge of the fanning plume. Since vertical mixing is steadily increasing under this temperature profile, the bottom of the fanning plume suddenly encounters a layer of air in which mixing is relatively good. The plume can then be drawn down to the ground in a fumigation which imposes high ground-level concentrations on the affected countryside. A similar action is encountered in the city. However, in this case, due to the nature of the surfaces and numbers of buildings, the city will hold in the daytime heat, and thus the formation of the inversion is delayed in time. Furthermore, the urban inversion will form in the upper atmosphere which loses heat to the outer atmosphere faster than it can be supplied from the surfaces of the city. Thus, the evening urban inversion tends to form in a band above the ground, thickening both toward the outer atmosphere and toward the ground. Smoke plumes can be trapped by this upper air radiation inversion, and high ground concentrations will be found in the early morning urban fumigation.
4.1.3 PRINCIPAL SMOKE-PLUME MODELS Even though the objective of air pollution control is to reduce all smoke emissions to nearly invisible conditions, some visible plumes are likely to be with us for quite a long while. Visible plumes are excellent indicators of stability conditions. Five special models have been observed and classified by the following names: 1. 2. 3. 4. 5.
Looping Coning Fanning Fumigation Lofting
All of these types of plumes can be seen with the naked eye. A recognition of these conditions is helpful to the modeler and in gaining an additional understanding of dispersion of pollutants. In the section immediately preceding this one, the condition for fanning followed by fumigation has been described. Lofting occurs under similar conditions to fumigation. However, in this case the plume is trapped above the inversion layer where upward convection is present. Therefore, the plume is lofted upwards with zero ground-level concentration resulting. When the day is very sunny with some wind blowing, radiation from the ground upward is very good. Strong convection currents moving upward are produced. Under these conditions plumes tend to loop upwards and then down to the ground in what are called looping plumes. When the day is dark with steady relatively strong winds, the temperature profile will be neutral so that the convection currents will be small. Under these conditions the plume will proceed downwind spreading in a cone shape. Hence the name coning © 2002 by CRC Press LLC
9588ch04 frame Page 48 Wednesday, September 5, 2001 9:44 PM
TABLE 4.1 The Size of Tall Things Sears Tower World Trade Center Empire State Building (1475 ft to top of mast) Chrysler Tower Eiffel Tower Gateway Arch Washington Monument
1450 ft 1350 ft 1250 ft 1040 984 630 555
ft ft ft ft
INCO Stack (Sudbury, ON) Kennecott Company (Magna, UT) Penn Electric Company New York State Electric Co. (Homer City, PA) American Electric Power Mitchell Plant (Cresap, WV) Keystone Group (Conamaugh, PA) TVA-Cumberland Plant TVA-Widows Creek Plant TVA-Kingston Plant
1250 ft 1215 ft 1210 ft 1206 ft 1000 ft 1000 ft 1000 ft 1000 ft
plume is applied. Under these conditions dispersion should most readily be described by Gaussian models.
4.2 THE TALL STACK The Tennessee Valley Authority (TVA) has pioneered the use of tall stacks in the U.S. and has carried out extensive experiments, collected data, and determined the design variables and mathematical models to predict minimum ground-level concentrations. The 170 ft stacks provided at the first large steam plant constructed by TVA at Johnsonville, TN, in 1952 were soon found to be inadequate. These stacks were then extended to 270 ft in 1955, and TVA stack height has crept upwards ever since. As evidence, the large coal-fired power plant at Cumberland City, TN, has two 1000-ft stacks, and the Kingston and Widows Creek Plants which each have a 1000-ft stack, topping the former tallest stacks at the Bull Run and Paradise plants by 200 ft. Ever since structural steel became plentiful and strong enough to carry extreme loads, longer and taller structures have been built. Competition in this area is keen, and one wonders whether stack structures grow out of a rational need to reduce ground-level concentrations, or out of man’s need to excel. Whatever the reason, it is amusing to compile and contemplate the statistics on tall structures, as listed in Table 4.1. Table 4.2 has the details of the TVA stacks at their major steam plants.
4.3 CLASSIFYING SOURCES BY METHOD OF EMISSION Table 4.3 summarizes useful methods by which air pollution sources can be classified. Dispersion models exist which fit into this scheme. For stationary sources three cases are defined: area sources, process stacks, and tall stacks.
4.3.1 A DEFINITION
OF
TALL STACKS
Adopting the TVA viewpoint to define a tall stack requires reference to the amount of furnace heat input which should be greater than 293 MW (109 BTU/h). A furnace
© 2002 by CRC Press LLC
9588ch04 frame Page 49 Wednesday, September 5, 2001 9:44 PM
TABLE 4.2 Major TVA Steam Plants First Unit in Operation
Unit No.
Rated Capacity Per Unit (MW)
Cumberland Bull Run Paradise
1972 1967 1963
Allen Gallatin
1959 1956
Colbert
1955
John Sevier
1955
Kingston
1954
Shawnee
1953
Widows Creek
1952
1–2 1 1–2 3 1–3 1–2 3–4 1–2 3–4 5 1–2 3–4 1–4 5–9 1 2–7 8 9 10 1–2 3 4,5,6 7 8 1–4 5–6 7–10 1–4
1300 950 704 1150 330 300 327.5 200 223 550.5 223 200 175 200 150 175 150 175 150 140.6 150 140.6 575 550 125 147 173 60
Name
Johnsonville
1951
Watts Bar
1942
a b c d
Stacks Total Plant (MW)
Number
Height (ft)
1700
2 1 2 1 3 1 1 2 2 1 1 1 2
1000 800 600 800 400 500 500 300 300 500 350 350 1000a
1750
2
800b
1978
1
1000c
1 1 4 2 2 4
500 500 270d 270d 400 177
2600 950 2558 990 1255 1397
846
1485
240
Original heights units 1–4, 250 ft, units 5–9, 300 ft. Replaces ten 250 ft stacks. Original six stacks 170 ft high, raised to 270 ft, then replaced. Original height 170 ft.
with this heat input would require 9072 kg/d (10,000 tons/d) of coal with a total heating value of 27.89 × 1010 J/kg (12,000 BTU/lb). A 100 MW plant would use about 771 kg/d (850 tons/d) and could qualify as having a tall stack. Most tall stack sources will be associated with fossil fuel burning steam electric power generating facilities. Another method to identify a tall stack is through the heat emission rate. This quantity should be greater than 20 MW (68.24 × 106 BTU/h) to define a tall stack. © 2002 by CRC Press LLC
9588ch04 frame Page 50 Wednesday, September 5, 2001 9:44 PM
TABLE 4.3 Classifying Air Pollution Sources by Method of Emission Moving Sources Transportation Using Fossil Fuel Internal combustion engine Jet engine Steam engine Stationary Sources Area Based Low-Level Urban Sources Result of space heating and trash burning Homes, apartments, commercial buildings Improper firing of furnaces, poor quality coal, uncontrolled emission Models: Require extensive source-emission information Process Stacks Chemical and Petroleum Processing Space heating and process steam May be result of leak or venting waste inorganic or organic gases Heights up to about 250 ft Low buoyancy, high velocity — could be a pure jet emission — plume rise not great Model: Gaussian, but must evaluate the effects of stack and building downwash and surrounding topographical features Tall Stacks Fossil Fuel Burning for Electrical Power Production Heights up to 1250 ft High buoyancy and velocity Plume rise significant Furnace heat input: 109 BTU/h (100 MW plant and larger) Heat emission rate: 19,000 BTU/s Stack height: 2.5 times height of tallest structure near stack Stack velocity: 1.5 times maximum average wind speed expected Model: Gaussian, maximum concentration encountered depends upon regional meteorological conditions and topographical features
Heat input is not the only requirement for establishing a tall stack. Such stacks produce plumes with great buoyancy, and these plumes have a high plume rise after leaving the stack. Furthermore, the exit velocity is high enough to avoid any building downwash. Rules of thumb to estimate the required exit velocity and stack height are h s > 2.5 h b vs > 1.5 u © 2002 by CRC Press LLC
9588ch04 frame Page 51 Wednesday, September 5, 2001 9:44 PM
where hs = vs = hb = u– =
height of stack stack exit velocity height of tallest structure near stack maximum average wind speed that will be encountered
When a stack satisfies all these conditions, it may be considered a tall stack, and calculations are simplified.
4.3.2 PROCESS STACKS All other point sources differ in several ways. Most process stacks are not connected to sources with a high furnace heat input. Thus buoyancy is limited, and plume rise may be smaller. Quite often these stack plumes will have a high velocity, but little density difference, compared to ambient conditions. Thus the plumes might be considered as jets into the atmosphere. Furthermore, since these stacks are usually shorter than 400 ft, the plumes may be severely affected by the buildings and the terrain that surround them. If stack efflux velocity is low, stack downwash may become prominent. In general, this is the kind of stack that is found in a chemical or a petroleum processing plant. Emissions from such a stack range from the usual mixture of particulates, sulfur oxides, nitrogen oxides, and excess air to pure organic and inorganic gases. To further complicate matters, these emissions usually occur within a complex of multiple point emissions; the result being that single-point source calculations are not valid. A technique for combining these process complex sources must then be devised.
4.4 ATMOSPHERIC-DIFFUSION MODELS An atmospheric-diffusion model is a mathematical expression relating the emission of material into the atmosphere to the downwind ambient concentration of the material. The heart of the matter is to estimate the concentration of a pollutant at a particular receptor point by calculating from some basic information about the source of the pollutant and the meteorological conditions. For a detailed discussion of the models and their use, refer to the texts by Turner1 and Schnelle and Dey.2 Deterministic, statistically regressive, stochastic models and physical representations in water tanks and wind tunnels have been developed. Solutions to the deterministic models have been analytical and numerical, but the complexities of analytical solution are so great that only a few relatively simple cases have been solved. Numerical solutions of the more complex situations have been carried out but require a great amount of computer time. Progress appears to be the most likely for the deterministic models. However, for the present, the stochastically based Gaussiantype model is the most useful in modeling for regulatory control of pollutants. Algorithms based on the Gaussian model form the basis of models developed for short averaging times of 24 hours or less and for long-time averages up to a year. The short-term algorithms require hourly meteorological data, while the long-term algorithms require meteorological data in a frequency distribution form. Algorithms © 2002 by CRC Press LLC
9588ch04 frame Page 52 Wednesday, September 5, 2001 9:44 PM
are available for single and multiple sources as well as single and multiple receptor situations. On a geographical scale, effective algorithms have been devised for distances up to 10 to 20 km for both urban and rural situations. Long-range algorithms are available but are not as effective as those for the shorter distance. Based on a combination of these conditions, the Gaussian plume model can provide at a receptor either 1. The concentration of an air pollutant averaged over time and/or space, or 2. A cumulative frequency distribution of concentration exceeded during a selected time period
4.4.1 OTHER USES
OF
ATMOSPHERIC-DIFFUSION MODELS
Atmospheric-diffusion models have been put to a variety of scientific and regulatory uses. Primarily the models are used to estimate the atmospheric concentration field in the absence of monitored data. In this case, the model can be a part of an alert system serving to signal when air pollution potential is high, requiring interaction between control agencies and emitters. The models can serve to locate areas of expected high concentration for correlation with health effects. Real-time models can serve to guide officials in cases of nuclear or industrial accidents or chemical spills. Here the direction of the spreading cloud and areas of critical concentration can be calculated. After an accident, models can be used in a posteriori analysis to initiate control improvements. The models also can be used for • • • • • • • •
Stack-design studies Combustion-source permit applications Regulatory variance evaluation Monitoring-network design Control strategy evaluation for state implementation plans Fuel (e.g., coal) conversion studies Control-technology evaluation New-source review
A current frequent use for atmospheric-diffusion models is in air-quality impact analysis. The models serve as the heart of the plan for new-source reviews and the prevention of significant deterioration of air quality (PSD). Here the models are used to calculate the amount of emission control required to meet ambient air quality standards. The models can be employed in preconstruction evaluation of sites for the location of new industries. Models have also been used in monitoring-network design and control-technology evaluation.
4.5 EPA COMPUTER PROGRAMS FOR REGULATION OF INDUSTRY The EPA has developed a series of atmospheric-dispersion programs available through the Support Center for Regulatory Air Models (SCRAM), now on the Web. © 2002 by CRC Press LLC
9588ch04 frame Page 53 Wednesday, September 5, 2001 9:44 PM
Models used for regulatory purposes were initially made available through the Users Network of Applied Modeling of Air Pollution (UNAMAP) system in three ways: (1) executable codes on EPA’s IBM mainframe at Research Triangle Park, (2) source codes for the UNISYS UNIVAC computer and test data on a magnetic tape from the National Technical Information Service (NTIS), or (3) source codes and test data in packed form from EPA’s UNAMAP Bulletin Board Service (BBS). During the summer of 1989, a new system for distribution was put in place. Source codes for models used for regulatory purposes were made available from the SCRAM Bulletin Board Service (SCRAM BBS) operated by EPA’s Office of Air Quality Planning and Standards (OAQPS). Updating this service, the models and technical information concerning their use are now available on the Web, at the OAQPS-established Technology Transfer Network. SCRAM is now available under this network at: http//www.epa.gov/scram001/main.htm. Using these programs, it is possible to predict the ground-level concentrations of a pollutant resulting from a source or a series of multiple sources. These predictions are suitable evidence to submit to states when requesting a permit for new plant construction. Of course, the evidence must show that no ambient air quality standard set by the EPA is exceeded by the predicted concentration. The basic dispersion model employed by the EPA SCRAM programs is the Gaussian equation. Briggs plume-rise method and logarithmic wind speed–altitude equations are also used in the algorithms comprising SCRAM. SCRAM requires the source–receptor configuration to be placed in either a rectangular or polar-type grid system. The rectangular system is keyed to the Universal Transverse Mercator (UTM) grid system employed by the U.S. Geological Survey on its detailed land contours maps. This grid is indicated on the maps by blue ticks spaced 1 km apart running both North–South and East–West. Sources and receptors can be located in reference to this grid system and the dispersion axis located from each source in reference to each of the receptor grid points. The polar grid system is used in a screening model to select worst meteorological conditions. If concentrations under the worst conditions are high enough, a more detailed study is conducted using the rectangular coordinate system. The location of the highest concentration then is determined within 100 m on the rectangular grid. Meteorological data is obtained from on-site measurement, if possible. If not, data must be used from the nearest weather bureau station. This data can be obtained from the National Weather Records Center in Asheville, NC. At the weather stations, data is recorded every hour. However, since 1964 the center in Asheville only digitizes the data every third hour. Thus air-quality impact analysis studies can employ 1964 hourly data for short averaging time studies. However, some of the SCRAM programs have meteorological data preprocessors which take the surface data and daily upper air data from the Asheville center and produce an hourly record of wind speed and direction, temperature, mixing-depth, and stability. The meteorological data is used in the dispersion programs to calculate hourly averages which are then further averaged to determine 3-hour, 8-hour, etc. up to 24-hour averages. Long-term modeling for monthly, seasonal, or annual averages require use of the same data and a special program known as STAR, for Stability Array. This program will compute an array of frequencies of occurrence of wind from the sixteen compass © 2002 by CRC Press LLC
9588ch04 frame Page 54 Wednesday, September 5, 2001 9:44 PM
directions, in one of six wind speed classes, for either five, six, or seven stability classes.
4.5.1 THE INDUSTRIAL SOURCE COMPLEX MODEL One of the most widely used models for estimating concentrations of nonreacting pollutants within a 10 mile radius of the source is EPA’s Industrial Source Complex Short-Term, Version 3 (ISCST3) program. It is a steady-state Gaussian plume model. Therefore, the parameters such as meteorological conditions and emission rate are constant throughout the calculation. There is also a long-term program, ISCLT. The time periods for the short- term program include 1, 2, 3, 4, 6, 8, 12, and 24 h. The ISCST3 program can calculate annual concentration if used with a year of sequential hourly meteorological data. The ISCLT is a sector-averaged model which combines basic features of several older programs prepared for the EPA. It uses statistical wind summaries and calculates seasonal or annual ground-level concentrations. ISCLT accepts stack-, area-, and volume-source types, and like the ISCST model, it uses the Gaussian-plume model. In both of these programs, the generalized plume-rise equations of Briggs, which are common to most EPA dispersion models, are used. There are procedures to evaluate effects of aerodynamic wakes and eddies formed by buildings and other structures. A wind-profile law is used to adjust observed wind speed from measurement height to emission height. Procedures from former models are used to account for variations in terrain height over receptor grid. There are one rural and three urban options which vary due to turbulent mixing and classification schemes. The models make the following assumptions about plume behavior in elevated terrain: • The plume axis remains at the plume stabilization height above mean sea level as it passes over elevated or depressed terrain. • Turbulent mixing depth is terrain following. • The wind speed is a function of height above the surface. • It truncates terrain at stack height if terrain height exceeds stack height.
4.5.2 SCREENING MODELS In scenarios where there are few sources or emissions which are not very large, it is usually advantageous to employ a screening model. For regulatory purposes, if the concentrations predicted by the screening model exceed certain significant values, a more refined model must be employed. EPA’s SCREEN3 is available for this screening operation. SCREEN3 allows a group of sources to be merged into one source, and it can account for elevated terrain, building downwash, and wind speed modifications for turbulence.
4.5.3 THE NEW MODELS CALPUFF, a multilayer, multispecies, nonsteady-state dispersion model that views a plume as a series of puffs is a new model under consideration. This model simulates © 2002 by CRC Press LLC
9588ch04 frame Page 55 Wednesday, September 5, 2001 9:44 PM
space–time, varying meteorological conditions on pollutant–transport, chemical reaction, and removal. It can be applied from around 100 ft downwind up to several hundreds of miles. The American Meteorological Society/EPA Regulatory Model (AERMOD) is a refined model currently under development by EPA as a supplement to ISCST3 for regulatory purposes. By accounting for varying dispersion rates with height, refined turbulence based on planetary boundary layer theory, advanced treatment of turbulent mixing, plume height, and terrain effects, AERMOD improves the estimate of downwind dispersion. AERMOD, along with AERMET, a meteorological data preprocessor, and AERMAP, a terrain data preprocessor, are state-of-the-art air quality models destined to become EPA’s regulatory model of choice. A new version of the ISCST3 model known as ISC-PRIME has become available. This model incorporates plume-rise enhancements and the next generation of building downwash effects. There are also a variety of specialized models for accidental release modeling, roadway modeling, offshore sources, and regional transport modeling.
4.6 THE SOURCE–TRANSPORT–RECEPTOR PROBLEM The heart of the matter with which we are dealing is, given a source emitting a pollutant, can we estimate, by calculation, the ambient concentration of that pollutant at a given receptor point? To make the calculation, it is obvious that we must have a well-defined source and that we must know the geographic relation between the source and the receptor. But we must understand the means of transport between the source and the receptor, as well. Thus source–transport–receptor becomes the trilogy which we must quantitatively define in order to make the desired computation.
4.6.1 THE SOURCE Defining the source is a difficult matter in most cases. We need to consider first whether it is mobile or stationary and then whether it is emitted from a point, in a line, or more generally from an area. Then we must determine its chemical and physical properties. The properties can be determined most appropriately by sampling and analysis, when possible. It is then that we turn, for example, to estimation by a mass balance to determine the amount of material lost as pollutant. The major factors that we need to know about the source are 1. 2. 3. 4. 5. 6.
Composition, concentration, and density Velocity of emission Temperature of emission Pressure of emission Diameter of emitting stack or pipe Effective height of emission
From these data, we can calculate the flow rate of the total stream and of the pollutant in question. © 2002 by CRC Press LLC
9588ch04 frame Page 56 Wednesday, September 5, 2001 9:44 PM
4.6.2 TRANSPORT Understanding transport begins with three primary factors that affect the mixing action of the atmosphere: radiation from the sun and its effect at the surface of the earth, rotation of the earth, and the terrain or topography and the nature of the surface itself. These factors are the subject of basic meteorology. The way in which atmospheric characteristics affect the concentration of air pollutants after they leave the source can be viewed in three stages: 1. Effective emission height 2. Bulk transport of the pollutants 3. Dispersion of the pollutants 4.6.2.1 The Effective Emission Height After a hot or buoyant effluent leaves a properly designed source, such as a chimney, it keeps on rising. The higher the plume goes, the lower will be the resultant groundlevel concentration. The momentum of the gases rising up the chimney initially forces these gases into the atmosphere. This momentum is proportional to the stack gas velocity. However, stack gas velocity cannot sustain the rise of the gases after they leave the chimney and encounter the wind, which eventually will cause the plume to bend over. Thus mean wind speed is a critical factor in determining plume rise. As the upward plume momentum is spent, further plume rise is dependant upon the plume density. Plumes that are heavier than air will tend to sink, while those with a density less than that of air will continue to rise until the buoyancy effect is spent. The buoyancy effect in hot plumes is usually the predominate mechanism. When the atmospheric temperature increases with altitude, an inversion is said to exist. Loss of plume buoyancy tends to occur more quickly in an inversion. Thus, the plume may cease to rise at a lower altitude, and be trapped by the inversion. Many formulas have been devised to relate the chimney and the meteorological parameters to the plume rise. The most commonly used model, credited to Briggs, will be discussed in a later section. The plume rise that is calculated from the model is added to the actual height of the chimney and is termed the effective source height. It is this height that is used in the concentration-prediction model. 4.6.2.2 Bulk Transport of the Pollutants Pollutants travel downwind at the mean wind speed. Specification of the wind speed must be based on data usually taken at weather stations separated by large distances. Since wind velocity and direction are strongly affected by the surface conditions, the nature of the surface, predominant topologic features such as hills and valleys, and the presence of lake, rivers, and buildings, the exact path of pollutant flow is difficult to determine. Furthermore, wind patterns vary in time, for example, from day to night. The Gaussian concentration model does not take into account wind speed variation with altitude, and only in a few cases are there algorithms to account for the variation in topography. For the future, progress in modeling downwind
© 2002 by CRC Press LLC
9588ch04 frame Page 57 Wednesday, September 5, 2001 9:44 PM
concentrations will come through increased knowledge of wind fields and numerical solutions of the deterministic models. 4.6.2.3 Dispersion of the Pollutants Dispersion of the pollutant depends on the mean wind speed and atmospheric turbulence. The dispersion of a plume from a continuous elevated source increases with increasing surface roughness and with increasing upward convective air currents. Thus, a clear summer day produces the best meteorological conditions for dispersion, and a cold winter morning with a strong inversion results in the worst conditions for dispersion.
4.6.3 THE RECEPTOR In most cases, legislation will determine the ambient concentrations of pollutant to which the receptor is limited. Air quality criteria delineate the effects of air pollution and are scientifically determined dosage–response relationships. These relationships specify the reaction of the receptor or the effects when the receptor is exposed to a particular level of concentration for varying periods of time. Air quality standards are based on air quality criteria and set forth the concentration for a given averaging time. Regulations have been developed from air quality criteria and standards which set the ambient quality limits. Thus the objective of our calculations will be to determine if an emission will result in ambient concentrations which meet air quality standards that have been set by reference to air quality criteria. Usually, in addition to the receptor, the locus of the point of maximum concentration, or the contour enclosing an area of maximum concentration, and the value of the concentration associated with the locus or contour should be determined. The short-time averages that are considered in regulations are usually 3 min, 15 min, 1 h, 3 h, or 24 h. Long-time averages are one week, one month, a season, or a year.
REFERENCES 1. Turner, D. B., A Workbook of Atmospheric Dispersion Estimates, 2nd ed., Lewis Publishers, CRC Press, Inc., Boca Raton, 1994. 2. Schnelle, Jr. K. B. and Dey, P. R., Atmospheric Dispersion Modeling Compliance Guide, McGraw-Hill, New York, 1999.
© 2002 by CRC Press LLC
9588ch05 frame Page 59 Wednesday, September 5, 2001 9:45 PM
5
Source Testing
5.1 INTRODUCTION Source testing is measuring the air pollutant concentration and/or quantity at a source or stack. The terminology implies using test methods to measure concentration on a one-time or snapshot basis, as opposed to continuously monitoring the source as discussed in Chapter 6. Source testing may be performed to provide design data or to measure performance of a process, or it may be prescribed on a periodic basis to demonstrate compliance with air permit emission limitations. Most source test procedures require labor to set up the test, collect samples, and analyze the results.
5.2 CODE OF FEDERAL REGULATIONS The gospel of source testing is the Code of Federal Regulations, 40 CFR Part 60, Appendix A.1 Very specific test procedures with step-by-step instructions are detailed in the CFR. A list of source test methods that are described in the CFR is provided in Table 5.1. These procedures have been tested, reviewed, and adopted by the EPA as the reference source test methods for a number of pollutants in a variety of applications. The universality of these test methods makes it easy for those practicing in the field to know just how a source test was conducted, and understand its limitations, just by giving a shorthand reference such as “Method 8.” Of course, the CFR test methods cannot be applied to all possible applications because it would have been impossible to evaluate and fund the research required for all circumstances. It would be an inefficient use of public funds for the EPA to sponsor research for test methods that cover unusual operating conditions for a unique process, and it is impossible to predict future processes, conditions, and improvements. Sometimes experience, judgment, and skill are needed to modify the test method to overcome a limitation that arises in a specific application. In such cases, test reports can reference the test method and describe the modification.
5.3 REPRESENTATIVE SAMPLING TECHNIQUES 5.3.1 GASEOUS POLLUTANTS One of the fundamentals in source testing for air contaminants is to obtain a representative sample of the gas stream. This is easy to do for gaseous pollutants, since molecules of gas can be assumed to be evenly distributed throughout the gas stream due to mixing and diffusion. It is highly unlikely that gaseous pollutants will segregate in a moving gas stream. A simple probe can be used to withdraw a sample. Due care must be used to avoid pulling a sample from a nonrepresentative location, such as just downstream of an injection point.
© 2002 by CRC Press LLC
9588ch05 frame Page 60 Wednesday, September 5, 2001 9:45 PM
TABLE 5.1 Code of Federal Regulations Source Test Methods Method 1 1A 2 2A 2B 2C 2D 3 3A 4 5 5A 5B 5C 5D 5E 5F 5G 5H 6 6A 6B 6C 7 7A 7B 7C 7D 7E 8
Description Sample and velocity traverses for stationary sources Sample and velocity traverses for stationary sources with small stacks or ducts Determination of stack gas velocity and volumetric flow rate (Type S pitot tube) Direct measurement of gas volume through pipes and small ducts Determination of exhaust gas volume flow rate from gasoline vapor incinerators Determination of stack gas velocity and volumetric flow rate in small stacks or ducts (standard pitot tube) Measurement of gas volumetric flow rates in small pipes and ducts Gas analysis for carbon dioxide, oxygen, excess air, and dry molecular weight Determination of oxygen and carbon dioxide concentrations in emissions from stationary sources (instrumental analyzer procedure) Determination of moisture content in stack gases Determination of particulate emissions from stationary sources Determination of particulate emissions from the asphalt processing and asphalt roofing industry Determination of nonsulfuric acid particulate matter from stationary sources Reserved Determination of particulate emissions from positive-pressure fabric filters Determination of particulate emissions from the wool fiberglass insulation manufacturing industry Determination of nonsulfate particulate matter from stationary sources Determination of particulate emissions from wood heaters from a dilution tunnel sampling location Determination of particulate emissions from wood heaters from a stack location Determination of sulfur dioxide emissions from stationary sources Determination of sulfur dioxide, moisture, and carbon dioxide emissions from fossil-fuel combustion sources Determination of sulfur dioxide and carbon dioxide daily average emissions from fossil-fuel combustion sources Determination of sulfur dioxide emissions from stationary sources (instrumental analyzer procedure) Determination of nitrogen oxide emissions from stationary sources Determination of nitrogen oxide emissions from stationary sources — ion chromatographic method Determination of nitrogen oxide emissions from stationary sources (ultraviolet spectrophotometry) Determination of nitrogen oxide emissions from stationary sources — alkalinepermanganate/colorimetric method Determination of nitrogen oxide emissions from stationary sources — alkalinepermanganate/ion chromatographic method Determination of nitrogen oxide emissions from stationary sources (instrumental analyzer method) Determination of sulfuric acid mist and sulfur dioxide emissions from stationary sources
© 2002 by CRC Press LLC
9588ch05 frame Page 61 Wednesday, September 5, 2001 9:45 PM
TABLE 5.1 (continued) Code of Federal Regulations Source Test Methods Method
Description
9 9 Alt. 1 10 10A
Visual determination of the opacity of emissions from stationary sources Determination of the opacity of emissions from stationary sources remotely by LIDAR Determination of carbon monoxide emissions from stationary sources Determination of carbon monoxide emissions in certifying continuous emission monitoring systems at petroleum refineries Determination of carbon monoxide emissions from stationary sources Determination of hydrogen sulfide content of fuel gas streams in petroleum refineries Determination of inorganic lead emissions from stationary sources Determination of total fluoride emissions from stationary sources — SPADNS zirconium lake method Determination of total fluoride emissions from stationary sources — specific ion electrode method Determination of fluoride emissions from potroom roof monitors for primary roof monitors for primary aluminum plants Determination of hydrogen sulfide, carbonyl sulfide, and carbon disulfide emissions from stationary sources Determination of total reduced sulfur emissions from sulfur recovery plants in petroleum refineries Semicontinuous determination of sulfur emissions from stationary sources Determination of total reduced sulfur emissions from stationary sources (impinger technique) Determination of total reduced sulfur emissions from stationary sources Determination of particulate emissions from stationary sources (in-stack filtration method) Measurement of gaseous organic compound emissions by gas chromatography Determination of sulfur dioxide removal efficiency and particulate, sulfur dioxide, and nitrogen oxides emission rates Determination of nitrogen oxides, sulfur dioxide, and diluent emissions from stationary gas turbines Determination of volatile organic compound leaks Visual determination of fugitive emissions from material sources and smoke emissions from flares Determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans from stationary sources Determination of volatile matter content, water content, density, volume solids, and weight solids of surface coatings Determination of volatile matter content and density of printing inks and related coatings Determination of total gaseous nonmethane organic emissions as carbon Determination of total gaseous organic concentration using a nondispersive infrared analyzer Determination of hydrogen chloride emissions from stationary sources Determination of vapor tightness of gasoline delivery tank using pressure–vacuum test Certification and auditing of wood heaters Measurement of air-to-fuel ratio and minimum achievable burn rates for wood-fired appliances
10B 11 12 13A 13B 14 15 15A 16 16A 16B 17 18 19 20 21 22 23 24 24A 25 25A 26 27 28 28A
© 2002 by CRC Press LLC
9588ch05 frame Page 62 Wednesday, September 5, 2001 9:45 PM
The primary consideration for gaseous pollutant sampling is that the sample is not contaminated, or decontaminated, by incompatibility with the materials of the sampling device or container. Teflon, stainless steel, and glass sample lines and containers often are used to avoid reactions with pollutants.
5.3.2 VELOCITY
AND
PARTICULATE TRAVERSES
Volumetric flow rate in a duct or stack is measured using a pitot tube to detect the difference between the static and dynamic pressure difference created by the velocity head at several points in the duct. Details of the tip of a pitot tube are shown in Figure 5.1. The measured pressure difference is used to calculate velocity. The key is to position the pitot tube at the correct points in the duct so that the average velocity is determined. This is done by positioning the pitot tube at the centroid of equal-area segments of the duct. Method 1 (CFR) provides tables for probe positions based on this principle. Figure 5.2 is an example of sampling points for a circular stack cross section. Figure 5.3 is an example for a rectangular duct. Note that the two lines of sampling points lie at 90°. For a circular duct, this requires at least two sampling ports at 90°. For small diameter stacks, the pitot tube can reach across the stack to pick up the points on the far side. For large diameter stacks, it is easier to reach no more than half way across the stack, so four sampling ports are provided to allow shorter sampling probes.
FIGURE 5.1 Pitot tube for velocity measurement.
© 2002 by CRC Press LLC
9588ch05 frame Page 63 Wednesday, September 5, 2001 9:45 PM
FIGURE 5.2 Traverse point locations for a round duct. The stack cross-section is divided into 12 equal areas with the location of traverse points indicated.
FIGURE 5.3 Traverse point locations for a rectangular duct.
Similarly, because each sampling position is representative of a small area of the duct or stack, particulate samples are withdrawn at the same traverse points at which velocity measurements are made. However, because particles do not necessarily follow the streamlines of gas flow and because gravity can act on particles in a horizontal duct, Method 1 recommends more traverse points for particulate sampling than for a simple velocity traverse. The minimum number of sample points for traverses depends on the proximity of the test port to flow disturbances in the duct, and to a lesser extent, the duct size. The minimum number of sample points for a velocity traverse is illustrated in Figure 5.4. The minimum number of samples to be taken for a particulate traverse is illustrated in Figure 5.5.
5.3.3 ISOKINETIC SAMPLING Extracting a particulate sample from a moving gas stream using a probe in a duct requires that the sample be taken at the same velocity as the gas flow, i.e., isokinetically. If the velocity of the sample is higher than that of the gas flow, then excess © 2002 by CRC Press LLC
9588ch05 frame Page 64 Wednesday, September 5, 2001 9:45 PM
FIGURE 5.4 Minimum number of sample points for a velocity traverse.
FIGURE 5.5 Minimum number of sample points for a particulate traverse.
gas moving toward the probe will divert toward the probe and be collected with the sample. Meanwhile, particles with sufficient momentum will tend to continue traveling in a straight line, leaving the gas flow streamlines and will not be carried into the sampling probe, as illustrated in Figure 5.6a. This produces a sample that, after measuring the collected gas volume and weighing the collected particulate filter, has an erroneously low particulate concentration. Similarly, if the sample velocity is too low, excess gas is diverted away from the probe while particles are carried into the probe, as illustrated in Figure 5.6b, resulting in an erroneously high particulate concentration. The correct isokinetic sample flow rate is determined by conducting a velocity traverse prior to collecting a particulate sample. During the particulate sample, the
© 2002 by CRC Press LLC
9588ch05 frame Page 65 Wednesday, September 5, 2001 9:45 PM
FIGURE 5.6 Reason for isokinetic sampling.
collected gas volume is measured with a gas meter. After the sample is taken and as data are being evaluated, the sample velocity as a percentage of gas velocity is determined and reported as a quality check on the particulate sample.
REFERENCES 1. Code of Federal Regulations, 40 CFR Part 60, Appendix A, Office of the Federal Register, National Archives and Records Administration, Washington, D.C., July 1, 1993.
© 2002 by CRC Press LLC
9588ch06 frame Page 67 Wednesday, September 5, 2001 9:46 PM
6
Ambient Air Quality and Continuous Emissions Monitoring
6.1 AMBIENT AIR QUALITY SAMPLING PROGRAM Air pollution monitoring is conducted to determine either emission concentration or ambient air quality. The range of emission concentrations, temperature, and pressures encountered is sometimes many magnitudes greater than found at an ambient air sampling station. For this reason, sampling and analysis techniques and equipment are different for each case, even though the same general principles may be employed. This chapter deals with both ambient air quality sampling procedures and monitoring and continuous emissions monitoring. Lodge1 presents a good discussion in Methods of Air Sampling and Analysis.
6.2 OBJECTIVES OF A SAMPLING PROGRAM Instrumentation for ambient air quality monitoring is perhaps best described in terms of the types of measurements that would be made in a typical community by the local air pollution control agency. Usually a sample network would be installed that would blanket the area with a series of similar stations. The object would be to measure the amount of gaseous and particulate matter at enough locations to make the data statistically significant. It is not uncommon to find each station in a network equipped with simple, unsophisticated grab sampling devices. However, quite a few sophisticated monitoring networks have been developed which contain continuous monitors with telemetry and computer control. Meteorological variables are also monitored and correlated with the concentration data. The information is then used: 1. To establish and evaluate control measures 2. To evaluate atmospheric-diffusion model parameters 3. To determine areas and time periods when hazardous levels of pollution exist in the atmosphere 4. For emergency warning systems
6.3 MONITORING SYSTEMS Ambient air quality data may be obtained through the use of mobile or fixed sampling networks and the use of integrated samplers or continuous monitors. Decisions
© 2002 by CRC Press LLC
9588ch06 frame Page 68 Wednesday, September 5, 2001 9:46 PM
regarding these monitoring techniques constitute the first important steps in design of a monitoring network.
6.3.1 FIXED
VS.
MOBILE SAMPLING
Fixed-point sampling entails a network of monitoring stations at selected sites, operated simultaneously throughout the study. Stations are permanent or, at least, long-term installations. In a mobile sampling network, the monitoring/sampling instruments are rotated on schedule among selected locations. The monitoring/sampling is not conducted simultaneously at all locations, and the equipment is generally housed in trailers, automobiles, or other mobile units. An advantage of fixed sampling is that measurements are made concurrently at all sites, providing directly comparable information, which is particularly important in determining relationship of polluting sources to local air quality and in tracing dispersion of pollutants throughout the area. The chief advantage of mobile sampling is that air quality measurements can be made at many sites — far more than would be feasible in a fixed sampling program. Mobile sampling provides better definition of the geographical variations if the program is long enough to generate meaningful data.
6.3.2 CONTINUOUS
VS. INTEGRATED
SAMPLING
Continuous monitoring is conducted with devices that operate as both sampler and analyzer. Pollutant concentrations are instantaneously displayed on a meter, continuously recorded on a chart, magnetic tape, or disk. Integrated sampling is done with devices that collect a sample over some specified time interval after which the sample is sent to a laboratory for analysis. The result is a single pollutant concentration that has been integrated, or averaged, over the entire sampling period. This is an older technique and currently in limited use. Continuous or automatic monitoring instruments offer some advantages over integrating samplers; for example, there is a capability for furnishing short-interval data, and there is a rapid availability of data. Moreover, output of the instruments can be electronically sent to a central point. Also, continuous monitors require less laboratory support. They also may be necessary to monitor some pollutants where no integrating method is available or where it is necessary to collect data over short averaging times, for example, 15 min. Automated monitors also have some drawbacks. They require more sophisticated maintenance and calibration, and the operators and maintenance personnel have to be more highly technically trained. The selection of a monitoring system is influenced by the averaging time for which concentrations are desired, i.e., 15-min, 1-h, 3-h, 8-h, 12-h, or 24-h time intervals. It should be consistent with the averaging times specified by air quality standards. For example, in assessing SO2 levels, good coverage can be provided by use of integrated samples, widely dispersed over the area, and one or more continuous sampler/analyzers situated in heavily populated areas. The integrated sampler defines SO2 levels over a broad area, and the continuous devices provide detailed information on diurnal patterns. The short averaging time of interest for CO and ozone dictates the use of continuous monitors for these pollutants.
© 2002 by CRC Press LLC
9588ch06 frame Page 69 Wednesday, September 5, 2001 9:46 PM
6.3.3 SELECTION
OF INSTRUMENTATION AND
METHODS
Choice of instrumentation for an air-monitoring network depends on the following factors: • • • • • •
Type of pollutants Averaging time specified by air quality criteria or standards Expected pollutant levels Available resources Availability of trained personnel Presence in the air of interfering materials
Most pollutants may be monitored by a number of different methods and techniques. The selection of the methodology to be used is an important step in the design of the monitoring portion of the assessment study.
6.4 FEDERAL REFERENCE METHODS AND CONTINUOUS MONITORING In order to evaluate the current air quality and the effect of air pollution control measures, most larger communities maintain monitoring networks. The EPA, as well as most of the states, maintains its own surveillance networks. The ideal objective when installing a monitoring network is to be able to obtain continuous real time data. Table 6.1 lists standard methods of measurement. Only 3 of these standard methods employ continuous or semicontinuous monitors. No satisfactory device exists as yet for determining suspended particulate on a continuous basis. However, Table 6.2 lists continuous methods which are now commonly employed for the measurement of the five regulated air pollutants.
TABLE 6.1 Federal Reference Methods Pollutant
Collection Method
Analysis
Sulfur dioxide Particulate matter Carbon monoxide Nitrogen dioxide Hydrocarbons
Absorption in bubbler Filtration in hi-volume sampler Continuous NDIR monitor Continuous monitor Semi-continuous monitor
Ozone Lead
Continuous monitor Filtration in hi-volume sampler
Spectrophotochemically Gravimetrically Absorption of infrared energy Chemiluminescence reaction with ozone Chromatographic separation with flame ionization detector Chemiluminescence reaction with ethylene Extracted by acid, atomic absorption spectrometry
© 2002 by CRC Press LLC
9588ch06 frame Page 70 Wednesday, September 5, 2001 9:46 PM
TABLE 6.2 Continuous Monitor Methods for Federally Regulated Pollutants Pollutant Sulfur dioxide
Carbon monoxide Nitrogen dioxide Hydrocarbons
Ozone
Continuous Monitor Method Conductrometric Coulometric Flame chemiluminescence Non-dispersive infrared or gas chromatograph, with conversion to methane, flame ionization detection, a semicontinuous method Coulometric Chemiluminescent reaction with ozone Gas chromatograph Flame ionization detector Semicontinuous Coulometric Chemiluminescent reaction with ethylene
Particulate matter emissions can be continuously detected through opacity measurements. Opacity is a function of light transmission through the plume and is define by the following equation OP = (1 − I I 0 ) × 100
(6.1)
where OP = percent opacity I = light flux leaving the plume I0 = incident light flux The following information, Documentation of the Federal Reference Methods for the Determination of the Regulated Air Pollutants, can be found in the Code of Federal Regulations, Title 40 (CFR 40) — Protection of Environment, Chapter 1, Environmental Protection Agency, Subchapter C — Air Programs, Part 50, National Primary and Secondary Ambient Air Quality Standards. The following is a list of those methods with reference to CFR 40.
Documentation of the Federal Reference Methods for the Determination of Regulated Air Pollutants Sulfur Dioxide Appendix A Reference Method for the Determination of Sulfur Dioxide in the Atmosphere (Pararosaniline Method) Particulate Matter Appendix B Reference Method for the Determination of Suspended Particulate in the Atmosphere — High Volume Method (Total suspended particulate has been replaced by PM10 and PM2.5.) © 2002 by CRC Press LLC
9588ch06 frame Page 71 Wednesday, September 5, 2001 9:46 PM
Carbon Monoxide Appendix C Measurement Principle and Calibration Procedure for the Continuous Measurement of Carbon Monoxide in the Atmosphere (Non-Dispersive Infrared Spectrometry) Ozone Appendix D Measurement Principle and Calibration Procedure for the Measurement of Photochemical Oxidants Corrected for Interferences Due to Nitrogen Oxides and Sulfur Dioxide Hydrocarbons Appendix E (Corrected for Methane) Reference Method for Determination of Hydrocarbons Corrected for Methane Nitrogen Dioxide Appendix F Measurement Principle and Calibration Procedure for the Measurement of Nitrogen Dioxide in the Atmosphere (Gas Phase Chemiluminescence) Lead Appendix G Reference Method for the Determination of Lead in Suspended Particulate Matter Collected from Ambient Air Ozone Appendix H Interpretation of the National Ambient Air Quality Standards for Ozone PM10 Appendix J Reference Method for the Determination of Particulate Matter as PM10 in the Atmosphere Particulate Matter Appendix K Interpretation of the National Ambient Air Quality Standards for Particulate Matter (Includes PM2.5)
6.5 THE “COMPLETE” ENVIRONMENTAL SURVEILLANCE AND CONTROL SYSTEM An ideal surveillance and control system can be devised employing continuous monitoring, telemetering, and electronic data processing. It is possible to assemble such a system from the hardware components that are now available. The major drawback of this automatic system is the limitations of the computer software; there is little economic information available for formulating the ambient air quality and optimizing models. Figure 6.1 illustrates one conception of a surveillance and control system. This system would demand instruments which could be calibrated to a known standard, would retain their calibration over long periods of time, would be © 2002 by CRC Press LLC
9588ch06 frame Page 72 Wednesday, September 5, 2001 9:46 PM
FIGURE 6.1 Conception of a surveillance and control system.
free of electronic drift over these long-time periods, and would possess suitable dynamic response. Many automated environmental surveillance systems employing continuous monitors exist in the U.S. and throughout the world. None are quite as sophisticated as would be implied by the system of Figure 6.1.
© 2002 by CRC Press LLC
9588ch06 frame Page 73 Wednesday, September 5, 2001 9:46 PM
6.6 TYPICAL AIR SAMPLING TRAIN A typical air pollution sampling train is applicable to the intermittent collection of an air sample containing either gaseous or particulate pollutants. The sample is retained in the collection equipment which is then removed for the sample train. Further processing takes place to prepare the sample for analysis. Most of the analysis techniques are standard procedures involving one or more of the following methods: 1. 2. 3. 4.
Gravimetric Volumetric Microscopy Instrumental a. Spectrophotometric i. Ultraviolet ii. Visible (Colorimetry) iii. Infra-red b. Electrical i. Conductometric ii. Coulometric iii. Titrimetric c. Emission Spectroscopy d. Mass Spectroscopy e. Chromatography
6.7 INTEGRATED SAMPLING DEVICES FOR SUSPENDED PARTICULATE MATTER Suspended particulate are small particulate that vary in size from less than 1 micron to approximately 100 microns. They remain suspended in the atmosphere for long periods of time and absorb, reflect, and scatter the sunlight, obscuring visibility. When breathed, they penetrate deeply into the lungs. They also cause economic loss because of their soiling and corrosive properties. The new EPA ambient particulate-matter definition includes only the part of the size distribution that could penetrate into the human thorax. This requires a sampling inlet with a 10 µm cutpoint to mimic deposition in the extra thoracic regions. Figure 6.2 is a schematic of a sampler designed to meet this requirement. There is a two-stage selective inlet. Air is drawn into the inlet and deflected downward into acceleration jets of the first-stage fractionator. Larger, non-inhalable particles are removed. Air then flows through the first stage vent tubes and then through the second fractionation stage. More non-inhalable particles are removed, and the remaining aerosol is drawn through the usual 8″ × 10″ sampling filter. The new PM10 standard includes only those particles with an aerodynamic diameter less than or equal to 10 µm. This standard went into effect on July 31, 1987.
© 2002 by CRC Press LLC
9588ch06 frame Page 74 Wednesday, September 5, 2001 9:46 PM
FIGURE 6.2 Two-stage particulate sampler.
6.8 CONTINUOUS AIR QUALITY MONITORS Continuous emissions monitoring (CEM) is required by the Clean Air Act Amendments to monitor SO2, NOx, CO, CO2, opacity, total hydrocarbons, and total reduced sulfur (TRS). Title IV, which is to ensure compliance with the Acid Rain Program, sets out provisions for CEM in the two-phase utility power industry control strategy. Phase I Utilities were required to install CEM by November 15, 1993, and Phase II Utilities by January 1, 1995. Title III focuses on 189 hazardous air pollutants (HAP), some of which will possibly require CEM. This should spawn CEM techniques optimized for the chemical compound being monitored. Title V will require CEM for compliance assurance. The collection of real-time emission data will be the first step to attaining the national mandated reduction in SO2 and NOx emissions. Furthermore, CEM can be used to track use of allowances in the new market-based SO2 emissions trading program. CEM is carried out by two general methods — in situ and extractive. Each of the methods measures on a volumetric basis, ppm for example. Therefore, the measurements require conversion to mass emission rates on a lb/h or lb/106 BTU basis. Monitoring instrumentation requires at least 10% relative accuracy. Performance specifications and test procedures can be found in Title 40 CFR, Part 60, Appendix B. © 2002 by CRC Press LLC
9588ch06 frame Page 75 Wednesday, September 5, 2001 9:46 PM
The EPA Emission Measurement Center (EMC) at Research Triangle Park and the Midwest Research Institute have created a data base on CEM. You may use browse techniques or search the data base by HAP or analyzer type. The data base is found on the EPA home page at: www.epa.gov/ttnami1/siteindx.html. Figure 6.3 is a schematic flow diagram of a general continuous air-quality monitor. The device contains: 1. Primary air-moving device, usually a vacuum pump, to pull the air sample through the instrument 2. Flow-control and -monitoring device, usually a constant pressure regulator and rotameter 3. Pollutant detection by various primary sensing techniques 4. Automatic reagent addition where needed 5. Electronic circuitry for transducing the primary signal to a signal suitable for recording and telemetering 6. Provisions for automatic calibration, usually several solenoid valves which can be operated remotely to connect the inlet gas to a scrubbing train for removal of all pollutants and establishing a chemical zero, or, alternatively, to one or more span gases for setting the chemical range of the instruments. Many monitors of the general type described above have been developed for all of the federally regulated gaseous pollutants and others as well. The remainder of this section will provide details of these devices. This list is not exhaustive. Furthermore, although the devices described below are indicated for a particular pollutant, they can be used for other types of pollutants as well.
6.8.1 ELECTROCONDUCTIVITY ANALYZER
FOR
SO2
Electrical conductivity was the basis of the first continuous monitor used to detect and monitor an air pollutant — SO2. This monitor was built by a Dr. Thomas to monitor SO2 in a greenhouse during a study of the effects of SO2 on plants. Later, it was employed by TVA in its original studies of SO2 from power plant plumes. In an electroconductivity apparatus, a reagent passes through a reference conductivity cell and then into an absorbing column. Air is drawn by a vacuum pump counter-currently to the reagent flow through the absorbing tube, then through a separator to the exhaust. The SO2 is absorbed in the reagent which then passes through a measuring conductivity cell. A stabilized AC voltage is impressed across the conductivity cells resulting in a current flow that is directly proportional to the conductivity of the solution. The value of this current is measured by connecting a resistor in series with the cell to obtain an AC voltage which is proportional to the current. This voltage is then rectified to direct current. The DC signals from the rectifiers are connected in opposition, thus resulting in a voltage that induces a current through a meter which is directly related to the difference in conductivity between the two solutions. To set the zero on the instrument, any SO2 is removed by passing the air through a soda-lime absorber. The conductivity in both cells should then be the same, and the meter output should be zero. © 2002 by CRC Press LLC
9588ch06 frame Page 76 Wednesday, September 5, 2001 9:46 PM
FIGURE 6.3 Generalized automatic continuous air pollution monitor.
© 2002 by CRC Press LLC
9588ch06 frame Page 77 Wednesday, September 5, 2001 9:46 PM
The principle of operation is as follows: a. The SO2 is oxidized in a reagent such as deionized water to form the sulphate ion which will cause a conductometric change related to amount of SO2 present. The reaction is as follows, H 2O + SO2 → H 2SO3 H 2SO3 + 1 2 O2 → H 2SO 4 b. Use of an acidified H2O2 solution reduces interference from acid gases such as CO2 SO2 + H 2O2 → H 2SO 4 c. The method is basically simple. However, since conductivity is temperature dependent, the analyzer section of any instrument must be thermostated.
6.8.2 COULOMETRIC ANALYZER
FOR
SO2
Principle of operation of a coulometric analyzer is similar to an electroconductivity apparatus, except three electrodes are required. One is a reference electrode. Figure 6.4 shows the three-electrode circuit. An air sample is drawn through a detector cell which contains a buffered solution of KI. Then iodine, I2, is generated at the anode, 2I − → I 2 + 2e −
FIGURE 6.4 Electrical circuit for a coulometric continuous monitor. © 2002 by CRC Press LLC
9588ch06 frame Page 78 Wednesday, September 5, 2001 9:46 PM
The SO2 is oxidized by the I2. Unreacted iodine is reduced to iodide, I–, at the cathode. I 2 + 2e − → 2I − Due to the loss of I2 by reaction with SO2, the cathode current is less than the anode current. The difference is proportional to the SO2 concentration through a Faradaic expression. The reference electrode serves as a reference to both poles and registers this imbalance in anodic input current and cathodic output current, ir = ia = ic. A selective scrubber removes interferents such as O3, mercaptans, and H2S, improving specificity of instrument. A zero gas is provided by using an activated carbon filter to remove impurities in air, including SO2. The gas flow is regulated by pressure control and a capillary tube which provides a constant pressure and pressure drop, and thus a constant flow. A pulsation damper adds volume to the system to provide stability of flow. The water supply is constantly replenished when evaporation occurs.
6.8.3 NONDISPERSIVE INFRARED METHOD
FOR
CO
Over the past 40 years, continuous infrared spectrometers have grown to be one of the most satisfactory instruments for determining carbon monoxide concentration in the atmosphere. The nondispersive instruments do not employ spectral separation of the radiation but make use of the specific radiation absorption of heteroatomic gases in the infrared range between 2.5 and 12 µm. The total absorption in the range is measured by an alternating light photometer with two parallel beams and a selective radiation receiver. The sample gas is passed through the sample cell which is arranged parallel to a reference cell containing a gas which absorbs no radiation. The radiation emitted by two nickel-chrome filaments reaches the two receiving cells after passing through the sample cell and reference cell, respectively. The receiving cells are filled with the gas component to be measured (CO in this case) and are separated by a metal diaphragm. The incident radiation is absorbed selectively in the specific absorption bands. Every gas has an absorption spectrum consisting of one or two individual absorption bands which are specific for the gas. Carbon monoxide has a band from 4.5–5.0 µm. The absorbed energy is transformed into thermal energy. Any difference in absorbed energy produces a temperature and pressure difference between the two receiving cells. This pressure difference deflects the diaphragm and thus changes the capacitance of the diaphragm capacitor. The diaphragm capacitor is connected to a high-impedance resistor which generates an alternating millivolt voltage that can be amplified, rectified, and displayed by a recorder. All infrared analyzers employ the same nondispersive measurement principle, but there are differences in the manufacturer’s design. One major difference among the analyzers is the length of the measuring cell. The length of the cell has little effect on the measuring range of the analyzer, and both analyzers are capable of being changed to provide several measuring ranges.
© 2002 by CRC Press LLC
9588ch06 frame Page 79 Wednesday, September 5, 2001 9:46 PM
Two infrared sources are used, one for the sample energy beam, the other for the reference energy beam. The beams are blocked simultaneously ten times per second by the chopper, a two-segmented blade rotating at five revolutions per second. In the unblocked condition, each beam passes through the associated cell and into the detector. The sample cell is a flow-through tube that receives a continuous stream of sample. The reference cell is a sealed tube filled with a reference gas. The reference gas is selected for minimal absorption of infrared energy of those wavelengths absorbed by the sample component of interest. The detector consists of two sealed compartments separated by a flexible metal diaphragm. Each compartment has an infrared transmitting window, to permit entry of the corresponding energy beam. Both chambers are filled, to the same subatmospheric pressure, with the vapor of the component of interest. Use of this substance as the gas charge in the detector causes the instrument to respond only to that portion of net difference in energy due to the presence of the measured component. In operation, the presence of the infrared-absorbing component of interest in the sample stream causes a difference in energy levels between the sample and reference sides of the system. This differential energy increment undergoes the following sequence of transformation: a. Radiant energy: In the sample cell, part of the original energy of the sample beam is absorbed by the component of interest. In the reference cell, however, absorption of energy from the reference beam is negligible. b. Temperature: Inside the detector, each beam heats the gas in the corresponding chamber. However, since energy of the reference beam is greater, gas in the reference chamber is heated more. c. Pressure: Higher temperature of gas in the reference chamber raises the pressure of this compartment above that of the sample chamber. d. Mechanical energy: Gas pressure in the reference chamber distends the diaphragm toward the sample chamber. The energy increment is thus expended in flexing the diaphragm. e. Capacitance: The diaphragm and the adjacent stationary metal button constitute a two-plate variable capacitor. Distention of the diaphragm away from the button decreases the capacitance. When the chopper blocks the beams, pressures in the two chambers equalize, and the diaphragm returns to the undistended condition. As the chopper alternately blocks and unblocks the beams, therefore, the diaphragm pulses, thus changing detector capacitance cyclically. The detector is part of an amplitude modulation circuit that impresses the 10 Hz information signal on a 10 MHz carrier wave provided by a crystal-controlled radio-frequency oscillator. Additional electronic circuitry in the oscillator unit demodulates and filters the resultant signal, yielding a 10 Hz signal. The 10 Hz signal is routed to the amplifier/control section for amplification and phase inversion, then back into the analyzer section for synchronous rectification. The resulting fullwave-rectified signal is returned to the amplifier/control section for filtering and additional conditioning, as required, to drive the meter and recorder.
© 2002 by CRC Press LLC
9588ch06 frame Page 80 Wednesday, September 5, 2001 9:46 PM
6.8.4 FLAME PHOTOMETRIC DETECTION
OF
TOTAL SULFUR
AND
SO2
Sulfur compounds introduced into a hydrogen-rich flame produce strong luminescent emissions between 300 and 423 nm. A narrow-band optical filter placed between the flame and detector permits transmission at 394 ± 5 nm. This produces a specificity ratio of between 10,000 and 30,000 to 1 for sulfur compounds. A photomultiplier tube detects the emission. When it is desired to study a mixture of sulfur compounds such as SO2, H2S, CS2, and CH2SH, the mixture is first passed through a gas chromatograph. A typical column employs 24 ft of 1/8 in. i.d. tubing packed with 30 to 40 mesh Teflon® which is coated with 10% polyphenol containing phosphoric acid. For the usual ambient conditions, the use of a chromatographic column is not warranted since the sulfur in ambient air is usually in the form of SO2.
6.8.5 HYDROCARBONS
BY
FLAME IONIZATION
A simple hydrocarbon monitor can be built using a flame ionization detector. Carbon atoms produce ions in a hydrogen flame. Thus, the air stream containing hydrocarbons is fed into a hydrogen flame. The ions produced are detected by an electrometer. The hydrocarbon concentration is proportional to the current. It has been found that CH4 can be separated by gas chromatographic technique from other hydrocarbons. An employing flame ionization detection has been constructed. Carbon monoxide is detected in the device by catalytically converting the CO to CH4 over a nickel catalyst after it has been separated from the rest of the gases by the gas chromatographic technique.
6.8.6 FLUORESCENT SO2 MONITOR Sulfur dioxide molecules fluoresce when irradiated by ultraviolet light in the 1900 to 3000 nm waveband. The optimum excitation takes place in the narrower range between 2100 and 2300 nm. An ultraviolet light such as a quartz deuterium lamp is used to produce the source of radiation. Selective narrow-band transmission is achieved by optical filters. Subsequently, the collimated narrow-band light beam then passes through a reaction chamber, where the sample also flows. The resultant fluorescence, directly proportional to the number of SO2 molecules present in the reaction chamber, is then measured by a blue sensitive photomultiplier tube.
6.8.7 CHEMILUMENESCENCE FOR DETECTION AND NITROGEN OXIDES
OF
OZONE
In 1889, Arrhenius first proposed that an energy of activation was required in order for a chemical reaction to take place. By acquiring this activation energy, a reacting molecule or atom could combine with other molecules or atoms in a chemical reaction. Around 1914 to 1930, the collision theory of reaction prevailed in which the molecules were postulated to acquire the necessary energy of activation by colliding with each other. Molecules were then conceived to be somewhat like hard spheres, and the rate of reaction was determined to be proportional to the number © 2002 by CRC Press LLC
9588ch06 frame Page 81 Wednesday, September 5, 2001 9:46 PM
of collisions of these marble-like molecules in a given time. Quantum theory of the 1920s introduced the idea of probability, and the round-sphere idea was replaced by the probability function. Building on the Arrhenius activation energy idea and the probability theory of quantum mechanics, Eyring and Polyani in 1931 proposed an activated complex theory2 of chemical reaction. This theory looks at the potential energy of the reacting system as the molecules come closer together. The rate of reaction is then found as the probability of a molecule crossing an energy barrier. In order to cross the barrier, the molecule must become an activated complex. The picture one can write of a chemical reaction is illustrated by the nitric oxide–oxygen reaction. 2 NO + O2 → ( NO − O2 )
Activated
(NO − O2 ) → 2NO2
Complex
Thus, the collision of hard spheres is replaced by a smooth continuous transition of reactants to products. In a photochemical reaction, the activation energy comes from a quarter of light. This light may be obtained from the ultraviolet or infrared region as well as from the visible range. Photochemical reactions are primary processes; however, luminescence belongs to a class of reactions in which a secondary photochemical process takes place after the acquisition of an initial energy. Four luminescence processes are recognized. 1. Fluorescence — after excitation by light there is an emission of light of a different wave length. 2. Phosphorescence — where an emission of light continues after the excitation source is removed. 3. Thermoluminescence — where, for example, crystals are irradiated with X-rays. Electrons are excited and trapped at a higher energy level. When the crystal is heated, the electrons drop to a lower energy level with the emission of light. 4. Chemiluminescence — which is an emission of light as a result of a chemical reaction at environmental temperature. An example of chemiluminescence is the reaction between nitric oxide and ozone. 1. NO in lower energy state than O3 becomes activated. NO → ( NO)
‡
2. NO crosses over to the O3 energy level. 3. An activated complex is formed between (NO) and O3.
(NO)‡ → (NO − O3 )
‡
© 2002 by CRC Press LLC
9588ch06 frame Page 82 Wednesday, September 5, 2001 9:46 PM
4. Reaction proceeds to nitrogen dioxide leaving NO2 in a higher energy state.
(NO − O3 )
‡
→ ( NO2 ) + O2 ‡
5. NO2 drops to a lower energy state with the emission of a quanta of light, hv.
(NO2 )
‡
→ NO2 + hv
Commercial monitors have been developed employing this process. Ozone is detected in reaction with ethylene. Nitric oxide is detected in reaction with ozone, and nitrogen dioxide is detected by first reducing it to nitric oxide then using the ozone reaction.
6.8.8 CALIBRATION
OF
CONTINUOUS MONITORS
6.8.8.1 Specifications for Continuous Air-Quality Monitors It is unfortunate that terms used in specifying and calibrating air-monitoring instrumentation are sometimes ambiguous. Thus we find the term “dynamic” dilution being used to mean diluting a flowing gas stream under carefully controlled constant flow conditions to produce an accurately and precisely known concentration. A preferred term would be “steady state” dilution which can be used to describe gas in flow but has none of the connotation of transient which the term dynamic might imply. To be most useful, specifications for instrumentation where flowing fluids are involved should provide information about the instrument which would impart to the user a knowledge about both its steady state and transient performance. Steady-state calibrations should be made at several levels of concentration over the expected range of concentrations that will be found. Comparison to the accepted standard method, absorption in a bubbler with West and Gaeke analysis for sulfur dioxide, for example, should be made as well. Replicate runs at the several levels of concentration can be compared through statistical analysis using factors such as the multiple correlation coefficient. In addition, the drift of the zero and span or range of the instrument should be low so that very little error will be introduced into the accuracy and precision of the instrument. Dynamic response testing can be used to determine transient and frequency response characteristics of continuous monitors. The most complete dynamic description of a system is its transfer function which is the ratio of the Laplace transformed output signal to the Laplace transformed input signal. Knowing the transfer function means that the output signal can be determined from any given input signal. Frequency response curves are essentially a graphical record of the transfer function and are thus useful to depict the dynamic response of a system. Transient response curves such as might be provided from a step test are valid only for the particular input function which produced the curves and are, thus, of limited © 2002 by CRC Press LLC
9588ch06 frame Page 83 Wednesday, September 5, 2001 9:46 PM
usefulness. Even more limited in specifying instruments is the rise time and fall time, which provides no information about the shape of the transient curve. The bad news is the difficulty to which the experimenter is put in order to determine the transient characteristics or the transfer function. The good news is that the need for the detailed transient information provided by the transfer function is not usually required. Additional instrument specifications are concerned with the effect of the ambient conditions imposed on the instrument including interfering substances. A common glossary of terms follows. These terms have been classified according to definition, steady-state specification, dynamic specification, or ambient specification. 6.8.8.2 Steady-State Calibrations One of the most difficult problems encountered in calibrating air pollution instrumentation is the production of low-level concentrations which are in the range encountered in the atmosphere. There are several suppliers of gas cylinders with prepared and certified low-level gas concentrations. Most usually these gases will have to be diluted before use, which poses a problem in maintaining strictly controlled temperatures, pressures, and flow rates. This writer discovered a paradox when using a cylinder of carbon monoxide prepared to a specified low concentration. A small but significant difference between two low levels of concentration was found when calibrating a nondispersive infrared analyzer (NDIR). The companies supplying the gases were contacted. One company reported that they were sure of their analysis because they used the best instrument for lowlevel carbon monoxide concentration determination — a nondispersive infrared instrument. The net result was that the company was comparing NDIR instruments and not conducting a calibration with a true standard. From the author’s viewpoint this situation is to be avoided. The permeation tube is a device which can provide low-level concentrations. These tubes TABLE 6.3 are made of a material such as Teflon and conAvailable Permeation Tubes tain a compound whose concentration is Sulfur dioxide Propane desired, sealed into the tube as a liquid. The Nitrogen dioxide Propylene vapor will then permeate through the walls of Hydrogen sulfide Butane the tube at a constant rate dependent on the Chlorine Butene-1 surface area exposed and the temperatures to Hydrogen fluoride Cis-butene-2 which the tube is subjected. The basic determiDimethyl sulfide Trans butene-2 nation of permeation rate can be made graviDimethyl disulfide Ethylene oxide metrically; thus, a permeation tube can become Methyl mercaptan Others a true standard. Table 6.3 lists some of the gases for which permeation tubes are available. Tubes of proper length can be used to calibrate gas analyzers at a steady-state flow condition. An apparatus must be prepared to hold the tube in a pure-air or nitrogen stream of known flow rate and at a constant temperature. A tube holder may be made from a standard vacuum trap with the tube in the center well and the outer section filled with glass beads to promote heat exchange. The tube holder is © 2002 by CRC Press LLC
9588ch06 frame Page 84 Wednesday, September 5, 2001 9:46 PM
placed in a constant temperature bath. Concentration can be varied through a manipulation of pure carrier gas flow rate, temperature, or tube length. The length of the tube required to produce the desired gas concentration can be estimated from the formula given below: L=
CF K Pt
(6.2)
where L = C = F = K =
length in cm concentration in ppm (vol) flowrate of carrier gas in cm3/min constant dependent upon gas at 1 atm, 25°C 0.382 for SO2; 0.532 for NO2; 0.556 for propane Pt = permeation rate for stated operating temperature
Note that concentration can be varied by changing tube temperature or length or carrier gas flowrate.
REFERENCES 1. Lodge, J. P., Jr., Ed., Methods of Air Sampling and Analysis, Interscience Committee of A&WMA, ACS, AIChE, APWA, ASME, AOAC, HPS, and ISA; Lewis Publishers Inc., Chelsea, MI, 1989. 2. Glasastone, S., Laidler, K. J., and Eyring, H., The Theory of Rate Processes, McGrawHill Book Co., New York, 1941.
© 2002 by CRC Press LLC
9588ch07 frame Page 85 Wednesday, September 5, 2001 9:47 PM
7
Cost Estimating
Cost is a basic and crucial decision-making factor in the selection of air-pollution control equipment. Evaluating costs can be straightforward, as long as there is an understanding as to the objective of the analysis and an appreciation of the time value of money. The classic cost trade-off is between capital and operating costs. This chapter is designed to assist the practicing engineer with cost engineering techniques for estimating capital cost of equipment and for determining the annualized cost of operating air-pollution control systems, such as required for the cost analysis portion of a BACT analysis. It is not intended to cover detailed cost accounting methods that include different types of depreciation and taxes.
7.1 TIME VALUE OF MONEY Because of interest and inflation, a dollar in U.S. currency today will be worth more than a dollar in the future. Right off the bat we must distinguish between the “real” interest rate, which does not include inflation, and the “nominal” interest rate, which includes inflation. The “real” or “constant” dollar cost analysis considers the return on investment as profit. This type of analysis frequently is used by engineers because it is straightforward, easy to use, and easy to understand. Annual operating and labor costs of $100,000 this year will remain at $100,000 per year in 10 years. To be clear, the analysis is stated to be in “year 2000 dollars.” Conversely, inflation reduces the value or buying power of the currency with time. $100,000 worth of materials and labor this year will require more money in 10 years. The real and nominal interest rates are related by:
(1 + i n ) = (1 + i) (1 + r )
(7.1)
where in = nominal interest rate i = real interest rate r = annual inflation rate Financial decisions that include the effect of income taxes use the nominal interest rate because both depreciation deductions and taxes are figured on the basis of nominal dollars.
7.1.1 ANNUALIZED CAPITAL COST The key to annualizing capital cost in real, pre-tax dollars is to calculate the capital recovery factor (CRF).
© 2002 by CRC Press LLC
9588ch07 frame Page 86 Wednesday, September 5, 2001 9:47 PM
i (1 + i) (1 + i)n − 1 n
CRF =
(7.2)
where CFR = capital recovery factor i = real pretax marginal rate of return on private investment n = economic life of the equipment for the analysis The product of the capital recovery factor and the capital cost, or investment (P), is the annualized capital recovery cost (CRC). CRC = CRF × P
(7.3)
7.1.2 ESCALATION FACTORS Several cost indexes are available that reflect current costs to a baseline cost. Examples include the Marshall & Swift Equipment Cost Index and the Chemical Engineering Plant Cost Index. Specific to the air-pollution control industry is the Vatavuk Air Pollution Control Cost Index.1 An index is used to convert a known cost at one point in time to an escalated cost at another point in time. The conversion is simply the ratio of the index values for the two points in time. Indexes are useful for the time periods covered by the index. The Vatavuk Air Pollution Control Cost Index begins in the first quarter of 1994 with a baseline value of 100. Cost data obtained prior to 1994 cannot be escalated using the Vatavuk index, but the Marshall & Swift Equipment Cost Index can be used from a baseline date of 1926. Vatavuk Air Pollution Control Cost Indexes are provided for specific air-pollution control devices, including carbon adsorbers, catalytic incinerators, electrostatic precipitators, fabric filters, flares, gas absorbers, mechanical collectors, refrigeration systems, regenerative thermal oxidizers, and wet scrubbers. Updated values of the indexes are published in each biweekly issue of Chemical Engineering. Annual values for these indexes are provided in Table 7.1
7.2 TYPES OF COST ESTIMATES The accuracy of the project cost estimate and the effort required to calculate it must be appropriate for the decision being made. The American Association of Cost Engineers lists2 three types of estimates: • Order of magnitude • Budget • Definitive The “order-of-magnitude” cost estimate uses rules-of-thumb based on prior experience. The only data requirement is the system capacity. Frequently an exponential © 2002 by CRC Press LLC
9588ch07 frame Page 87 Wednesday, September 5, 2001 9:47 PM
TABLE 7.1 Vatavuk Annual Average Air-Pollution Control Cost Index1
Carbon adsorbers Catalytic incinerators Electrostatic precipitators Fabric filters Flares Gas absorbers Mechanical collectors Refrigeration systems Regenerative thermal oxidizers Thermal incinerators Wet scrubbers a
1994
1995
1996
1997
1998
1999
2000a
101.2 102.0 102.8 100.5 100.5 100.8 100.3 100.5 101.4 101.3 101.3
110.7 107.1 108.2 102.7 107.5 105.6 103.0 103.0 104.4 105.9 112.5
106.4 107.0 108.0 104.5 104.9 107.8 103.3 104.4 106.3 108.2 109.8
104.7 107.7 108.8 106.2 105.8 107.6 103.9 106.1 107.9 109.4 109.0
103.6 106.5 109.2 109.5 103.6 109.7 111.0 107.6 108.9 110.5 109.7
100.8 102.9 101.2 111.7 99.4 110.9 119.6 105.7 108.1 108.1 108.8
107.8 113.0 101.0 113.2 104.5 112.8 121.8 106.1 109.1 108.0 113.7
Preliminary.
factor of 0.6 is used to factor the capacity of large facilities.3 The accuracy of orderof-magnitude is supposed to be +50% to –30% rather than a factor of 10 as the name implies. However, there is little control of accuracy, and this approach may amount to a best-guess with a very high level of inaccuracy. Budget estimates typically have an accuracy of +30% to –15%. These estimates require knowledge of the site, flow sheet, equipment, and buildings. Also, rough specifications for items such as insulation and instrumentation are needed. Definitive cost estimates, accurate to within ±20%, require complete plot plans, piping and instrument diagrams, specifications, and site surveys, as well as vendor bids for major equipment. Perry’s Chemical Engineers’ Handbook describes five levels of detail and accuracy for cost estimates:4 • • • • •
Order-of-magnitude Study (factored) with an accuracy of ±30% Preliminary (budget authorization) with an accuracy of ±20% Definitive (project control) with an accuracy of ±10% Detailed (firm or contractors) with an accuracy of ±5%
Note that these definitions for level of accuracy are not consistent between the two sources, which can easily lead to confusion when one simply refers to a descriptor such as a “budget” or “definitive” estimate. Even describing an estimate by its desired accuracy can be misleading. To achieve a desired level of accuracy, it is best to define the resources and approach that are to be used to develop the cost estimate. Air-pollution control equipment cost estimating at the “study” level with ±30% accuracy has received a great deal of attention because of the requirement to determine the “cost effectiveness” for best available control technology (BACT) analyses. To make a good study estimate, the following resources4,5 should be used: © 2002 by CRC Press LLC
9588ch07 frame Page 88 Wednesday, September 5, 2001 9:47 PM
• • • •
Location of the source within the plant Preliminary process flow sheet Preliminary sizing and material specifications for major equipment Approximate sizes and types of construction of any buildings required to house the control system • Rough estimates of utility requirements (e.g., steam, water, electricity, etc.)
7.3 AIR POLLUTION CONTROL EQUIPMENT COST 7.3.1 OAQPS CONTROL COST MANUAL To assist permit applicants and reviewing agencies, and to bring some semblance of consistency to the permit applications, the EPA has published guidelines5 for estimating the cost of various equipment including thermal and catalytic incinerators, carbon adsorbers, fabric filters, electrostatic precipitators, flares, refrigerated condensers, gas absorbers, and hoods, ductwork, and stacks. The manual provides a good overview of cost estimating methodology, descriptions of the control equipment and fundamentals of operation, cost correlations based on size and materials, and factors for operating costs.
7.3.2 OTHER COST-ESTIMATING RESOURCES The OAQPS Control Cost Manual does not discuss all air-pollution control devices, nor does it cover large, complex air-pollution control systems such as flue gas desulfurization systems. Traditional engineering cost estimating approaches may be applied in these cases. The design engineer produces a bill of materials including individual equipment items (vessels, pumps, blowers, exchangers, etc.). Using the equipment size and weight and material of construction, a cost-estimate can be produced. Common sources of equipment cost estimates include Perry’s Chemical Engineers’ Handbook4 and Richardson’s Process Plant Construction Estimating Standards.6 Additional material has been published by Vatavuk,7 who is also the primary author and editor of the OAQPS Control Cost Manual. A large amount of detailed cost information on utility flue gas desulfurization systems has been sponsored and published by the Electric Power Research Institute.8,9
REFERENCES 1. Vatavuk, W. M., Escalation Indexes for Air Pollution Control Costs, U.S. Environmental Protection Agency, EPA-452/R-95-006, Research Triangle Park, NC, 1995. 2. Humphreys, K. K. and Katell, S., Basic Cost Engineering, Marcel Dekker, New York, 1981, 108. 3. Peters, M. S. and Timmerhaus, K. D., Plant Design and Economics for Chemical Engineers, 3rd ed., McGraw-Hill, New York, 1980, 183. 4. Perry, R. H., Green, D. W, and Maloney, J. O., Perry’s Chemical Engineers’ Handbook, 7th ed., McGraw-Hill, New York, 1997, 9–64.
© 2002 by CRC Press LLC
9588ch07 frame Page 89 Wednesday, September 5, 2001 9:47 PM
5. OAQPS Control Cost Manual, 5th ed., U.S. Environmental Protection Agency, EPA 453/B-96-001, Research Triangle Park, NC, 1996. 6. Process Plant Construction Estimating Standards, Richardson Engineering Services, Inc., San Marcos, CA, 2001. 7. Vatavuk, W. M., Estimating Costs of Air Pollution Control, Lewis Publishers, Chelsea, MI, 1990. 8. Keeth, R. et al., Economic Evaluation of FGD Systems, GS-7193, Vol. 1 and 2, Electric Power Research Institute, Palo Alto, CA, 1991. 9. Keeth, R. J., Ireland, P. A., and Radcliffe, P. T., Economic evaluations of 28 FGD processes, presented at 1991 EPRI/EPA/DOE SO2 Control Symp., Washington, D.C., Dec. 3–6, 1991.
© 2002 by CRC Press LLC
9588ch08 frame Page 91 Wednesday, September 5, 2001 9:49 PM
8
Process Design and the Strategy of Process Design
8.1 INTRODUCTION TO PROCESS DESIGN Process design is the distinguishing feature which differentiates the chemical engineer from all other engineers. As the field of air-pollution control engineering has evolved over the past several decades, it is obvious that the air-pollution control engineer must adopt the ideas and principles of process design. In defining process design, we first define design as the development of a plan to accomplish a goal. The engineer must modify that definition to consider engineering design. Borrowing from a 19th century definition for railway engineering and extending the definition to our time, engineering design is “The art of engineering a safe, environmentally sound system for $1.00 which any fool can do for $2.00.” The engineer must now accept the responsibility to see that any engineering system is not only economically feasible, but it must be safe and meet environmental regulations. Two books that would be of assistance in developing the ideas of process analysis, synthesis, and design principles are the texts by Seider, Seader and Lewin1 and by Turton et al.2 Both of these books emphasize the use of computer-aided process design and are up to date in their viewpoint.
8.2 THE STRATEGY OF PROCESS DESIGN This book focuses on environmental process design and specifically air-pollution control design. This design proceeds in a sequence of steps from the planning stage to the equipment stage of an “air-pollution control” project. As each decision point is reached, the engineer must evaluate alternatives. The most technically and economically feasible alternatives must be chosen; these alternatives must also be safe and environmentally sound. Consider the following process as an example: It has been determined that NO2 emissions from the GREASKO LTD. plant have exceeded emission limitations. The orange cloud continues to be visible every day. The company management is deeply concerned for the community surrounding the plant and has determined that action must be taken to eliminate these emissions. Figure 8.1 illustrates the following likely sequence of events. • Calculated emission rates are verified by measurement, and sampling and laboratory analysis determine if emission limitations are being exceeded. • Equipment for the reduction of the NO2 must be installed.
© 2002 by CRC Press LLC
9588ch08 frame Page 92 Wednesday, September 5, 2001 9:49 PM
FIGURE 8.1 The process of process design. © 2002 by CRC Press LLC
9588ch08 frame Page 93 Wednesday, September 5, 2001 9:49 PM
• Final problem definition will identify the following factors as part of the design basis: • Composition of the stream • Flow rate • Temperature • Pressure • Variation of the operating parameters A series of decisions must now be made. 1. Decision Point 1: Alternative Control Techniques • Condensation • Absorption — Chosen • Adsorption 2. Decision Point 2: Absorption — Type of Absorber • Continuous — Packed Column — Chosen • Stage-wise 3. Decision Point 3: Flow Pattern • Counterflow — Chosen • Crossflow • Concurrent flow 4. Decision Point 4: A Major Impact — Disposing of the Collected Pollutant • Recycle • Recover • Incinerate • Landfill • React • Neutralize
Emphasizing the decision process, Phillips3 presents a detailed decision tree for the selection of the right device for removing particulates from a gas stream. He states that his process will help the designer to rapidly identify processes that are suitable for a particular application from 40 or more classes of processes available. In a letter to the editor, Nair4 takes issue with this detailed decision tree. He points out that a knowledgeable air-pollution control process designer will contact a vendor with the minimum information necessary for the design, and the vendor will do the design. Nair’s method leaves the air pollution control process designer with the question: What is an acceptable and feasible design? The authors present the material in this handbook to assist the air pollution control engineer in determining and recognizing a safe, environmentally sound, and feasible process design.
8.2.1 PROCESS FLOWSHEETS Beginning the process design, a simple basic flowsheet should be made. Even a pencil sketch can help explain better what will be required. Adding the process variables and the flowsheet can be a useful tool at every step. One way to begin is to draw a boundary around the whole process. This diagram can then serve to initiate
© 2002 by CRC Press LLC
9588ch08 frame Page 94 Wednesday, September 5, 2001 9:49 PM
FIGURE 8.2 The general mass and energy balance.
the basic mass and energy balances which will be discussed in the next section. As the process design develops, the recycle streams can be added to this input–output sketch. The flowsheet should then be modified and moved toward the final document to be used for the detailed design and cost estimation. Start with the air pollution control equipment, then add the needed appurtances such as ducting, piping, pumps, fans, and tanks. Finally, the instrument and automatic controls can be added.
8.3 MASS AND ENERGY BALANCES The basis for all process design is the mass and energy balances. Thermodynamics serves as the scientific background for these calculations. For a treatment featuring chemical processes see Smith, Van Ness, and Abbott.5 The basic mass and energy balance concept is presented by Felder and Rousseau.6 Figure 8.2 presents the general mass and energy balance. Here the “system” is receiving two input streams from the “surroundings” and is producing one outlet stream to the surroundings. Each stream enters the system at a height zi above a reference plane. Heat, Q, and shaft work, WS, are being supplied and considered positive transferred to the system from the surroundings. The overall mass balance in terms of flow rate is M A + MB = MC
(8.1)
A component mass balance can be made where the concentration xij is given in mass or mole fractions depending on the units of the flow rate. Here “i” designates the component and “j” designates the stream. x AA M A + x ABM B = x AC M c
© 2002 by CRC Press LLC
(8.2)
9588ch08 frame Page 95 Wednesday, September 5, 2001 9:49 PM
The energy balance can then be written using the convention of exit quantities minus inlet quantities. U2 U2 M C U C + PC ρC + C + zC g gC − M A U A + PA ρA + A + z A g gC α α 2 2 g g c c (8.3) U − M B U B + PB ρB + + z Bg gC = Q + WS α 2 g c 2 B
where Uj = internal energy Pj = pressure ρj = density of fluid — Uj = average velocity of stream α = a correction factor of 1.0 for turbulent conditions and 1/2 for laminar conditions g = acceleration due to gravity gc = gravitational constant Enthalpy is defined as H = U + Pv
(8.4)
where v = specific volume = 1/ρ The enthalpy can be calculated from specific heat at constant pressure. ∂H CP ≡ ∂TP T2
∆H =
∫ C dT = C P
P avg
(8.4)
(T2 − T1 )
(8.5)
T1
Equation 8.3 can be simplified for a single stream in, A, and a single stream out, C. Then, M A = MC Using ∆ to indicate the output–input difference,
© 2002 by CRC Press LLC
9588ch08 frame Page 96 Wednesday, September 5, 2001 9:49 PM
FIGURE 8.3 The mass balance.
∆H = H C − H A ∆U 2 = UC2 − U A2 ∆z = zC − Z A Equation 8.3 may now be written, ∆U 2 M ∆H + + ∆z g gC = Q + WS 2αgC
(8.6)
8.3.1 A MASS-BALANCE EXAMPLE Two streams enter a separations apparatus as shown in Figure 8.3. The streams mix and are separated. Two streams also leave the apparatus. The following lists the stream compositions. Stream 1
Stream 2
Stream 3
60% A 40% B
100% N
95% A 5% B
It is also known that the ratio of the flow rate of Stream 2 to Stream 1 is 5/1. The composition of Stream 4 is unknown and must be determined. All of the component A goes into Stream 3. Set the basis for calculation.
© 2002 by CRC Press LLC
9588ch08 frame Page 97 Wednesday, September 5, 2001 9:49 PM
Basis: 100 units of Stream 1. The units could be lb mass, kg mass, lb moles, or kg moles. Use kg moles. Stream 1 = 60 kg moles of A, 40 kg moles of B Stream 2 = 5 × 100 = 500 kg moles N A is a “tie substance” which can be used to determine how much of the total flow goes into Stream 3. Stream 3: 60 kg moles A = 95% of the stream 60/0.95 = 63.16 kg moles total flow 63.16 – 60 = 3.16 kg moles B Check: (3.16/63.16) × 100 = 5.00% B — Ok! Stream 4: N B
= 40 – 3.16
Total moles = 500 + 36.84 %N %B
= 500 kg moles = 36.84 kg moles = 536.84 kg moles
= (500/536.84) × 100 = 93.14% = (36/536.84) × 100 = 6.86%
Total
100.00%
8.3.2 AN ENERGY-BALANCE EXAMPLE Hot dirty air at 10,000 acfm, 1.0 atm, and 500°F is blown by a fan into a heat exchanger and then into a waste treatment process. Figure 8.4 illustrates the process. The air enters the blower at 125 ft/s. The blower has a 15 HP motor operating at 85% efficiency. The dirty air is cooled to 130°F at Point 2 and leaves the heat exchanger at 275 ft/s. Water at 80°F is available as a coolant. A 10°F temperature rise is allowed. Determine the amount of coolant required.
FIGURE 8.4 The energy balance.
© 2002 by CRC Press LLC
9588ch08 frame Page 98 Wednesday, September 5, 2001 9:49 PM
Data: Air density at 500°F: ρair = 0.0412 lbm ft 3 Air specific heat: C P avg = 0.241 BTU lbm - °F Water specific heat C P avg = 1.0 BTU lbm - °F Air enthalpy at 1: H1 = 231.1 BTU lbm Air enthalpy at 2: H 2 = 141.1 BTU lbm Solve Equation 8.6 for Q. ∆U 2 Q = M ∆H + + ∆z g g C − WS g 2α C Assume z = z2 – z1 = 0.0 and α = 1.0 M = 10, 000 ft 3 min × 0.0412 lbm ft 3 × 1.0 min 60 sec = 6.87 lbm sec ∆H = C P avg (T2 − T1 ) = 0.241(130 − 500) = −89.17 BTU lbm or ∆H = H 2 − H1 = 141.1 − 231.1 = −90.0 BTU lbm ∆H = 90 BTU lbm × 778 ft - lbf BTU × 6.87 lbm s = −476, 370 ft - lbf sec ∆U 2 (275) − (125) = 2αg c 2 × 32.174 2
2
ft 2 s2 = 932.4 ft - lbf lbm 2 ft - lbm lbf -s
∆U 2 = 932.4 ft - lbf lbm × 6.86 lbm s = 6402.7 ft - lbf s 2αg c WS = 0.80 × 15 HP × 550 ft - lbf s- HP = 6600.0 ft - lbf s Q = −476, 370 + 6403 − 6600 = −476, 567 ft - lbf s
(Shows ∆H to be the most significant factor.) Q = −476, 576 ft - lbf s × BTU 778 ft - lbf = −612.6 BTU s
© 2002 by CRC Press LLC
(8.6)
9588ch08 frame Page 99 Wednesday, September 5, 2001 9:49 PM
For the coolant QC = – Q,
Q C = mC p avg ∆T, ∆T limited to 10°F m=
QC 612.6 = = 61.26 lbm s C P avg ∆T 1 × 10
m = 61.26 lbm s × 60 s min = 3675.3 lbm min q w = 3675.3 lbm min × 1.0 gal 8.34 lbm = 440 gpm
REFERENCES 1. Seider, W. D., Seader, J. D., and Lewin, D. L., Process Design Principles — Synthesis, Analysis, and Evaluation, John Wiley & Sons, Inc., New York, 1999. 2. Turton, R., Bailie, R. C., Whiting, W. B., and Shaeiwitz, J. A., Analysis, Synthesis, and Design of Chemical Processes, Prentice-Hall, Englewood Cliffs, NJ, 1998. 3. Phillips, H. W., Select the proper gas cleaning equipment, Chem. Eng. Prog., 96(9), 19, 2000. 4. Nair, C., Letters — Gas cleaning equipment, Chem. Eng. Prog., 97(1), 10, 2001. 5. Smith, J. M., Van Ness, H. C., and Abbott M. M., Introduction to Chemical Engineering Thermodynamics, 6th ed., McGraw-Hill, New York, 2001. 6. Felder, M. R. and Rousseau, R. W., Elementary Principles of Chemical Processes, 3rd ed., John Wiley & Sons Inc., New York, 2000.
© 2002 by CRC Press LLC
9588ch09 frame Page 101 Wednesday, September 5, 2001 9:50 PM
9
Profitability and Engineering Economics
9.1 INTRODUCTION — PROFIT GOAL A major decision point in process design is the selection of the most technically and economically feasible solution alternative. All companies set a profit goal. Most generally it is to maximize profit, i.e., maximize income above the cost of the capital which must be invested to generate the income. In addition, current governmental regulations require that processes must be safe and ecologically/environmentally sound. Others goals sometimes are used. For example: • • • • •
Minimize loss Minimize operating cost Minimize environmental damage Zero emissions Produce a product that does not cost the company money
Furthermore, companies usually have set a required rate of return on the investment. In some cases such as with required environmental control equipment, the process must be built and operated even if it does not meet the rate of return that has been set.
9.2 PROFITABILITY ANALYSIS An analysis must be made to provide a measure of the attractiveness of a project for comparison to other possible courses of action. In some cases, the capital that would be invested in a process could earn more in some other investment or even in a savings account. For required environmental control processes there would be no other alternative investment allowed. It should be remembered, a profitability standard can only serve as a guide, and the profitability standard must be weighed against overall judgment and evaluation.
9.2.1 MATHEMATICAL METHODS
FOR
PROFITABILITY EVALUATION
There are at least five reasonable methods to carry out a profitability evaluation. These methods are 1. Rate or incremental rate of return on investment 2. Discounted cash flow on full-life performance
© 2002 by CRC Press LLC
9588ch09 frame Page 102 Wednesday, September 5, 2001 9:50 PM
FIGURE 9.1 Optimization of cost for a typical fabric filter or baghouse.
3. Net present worth 4. Capitalized costs 5. Payout period Peters and Timmerhaus1 present an excellent discussion of all these methods. Figure 9.1 illustrates the well-known concept in balancing fixed capital charges for a fabric filter against operating cost to find the minimum of the sum of the two.
9.2.2 INCREMENTAL RATE OF RETURN ON INVESTMENTS AS A MEASURE OF PROFITABILITY One of the more simple methods of profitability analysis is based on rate of return and the incremental rate of return. It is assumed that there is a base case design that will provide the desired pollution control and meet the profitability objective set as the rate of return. As pointed out above, in some cases a pollution control apparatus must be built even if it does not meet a the profitability objective of a company. The base case should represent a system operating under nearly optimum conditions. All other designs are then compared against this base case. Defining the terms: ROI = percent return on investment IROI = incremental percent return on investment P = annual profit from invesment (income – expenses), or incremental profit or annual savings I = total investment or incremental investment ROI or IROI = The process is as follows: © 2002 by CRC Press LLC
P I
(9.1)
9588ch09 frame Page 103 Wednesday, September 5, 2001 9:50 PM
• Set the base case — the alternative case that meets ROI at the least total initial cost. • Check IROI with base case compared to alternative case that meets the ROI and has the second lowest initial cost. • Accept the second alternative as base case if IROI is met. • With this new base case, check ROI compared to alternative that has the third lowest initial cost and then check the IROI. Set new base case if IROI is met. • Repeat process with all alternatives and select one that meets the ROI and the IROI by balancing the initial cost the ROI and the IROI. 9.2.2.1 An Example A chemical plant must install a new control system. Four alternatives are being considered. Each alternative will result in a reduction of emissions from the current 2000 T/year. The emissions fee is $35/T, and, therefore, the new equipment will reduce the annual emission fee. Furthermore, two of the processes will result in saving product for which an additional cost saving can be included. The company is demanding a 15% return on any investment. Which of the processes should be selected? DESIGN Installed cost ($) Operating cost ($) Fixed charges % of initial cost ($/yr) Emission reduction ($) Product saved ($/yr)
A
B
C
D
100,000 5000 10% 10,000 900 T 31,500 0
150,000 10,000 10% 15,000 1200 T 42,000 6000
200,000 15,000 10% 20,000 1200 T 42,000 8000
250,000 10,000 10% 25,000 1500 T 52,500 21,000
Design A serves as the base case. A. Annual savings = 0 + 31,500 – 5,000 – 10,000 = $16,500 ROI =
16, 500 × 100 = 16.5% 100, 000
Meets ROI criteria. B. Annual savings = 6000 + 42,000 – 10,000 – 15,000 = $23,000 ROI = This ROI is acceptable. © 2002 by CRC Press LLC
23, 000 × 100 = 15.3% 150, 000
9588ch09 frame Page 104 Wednesday, September 5, 2001 9:50 PM
IROI =
23, 000 × 100 = 46.0% 50, 000
This IROI is acceptable, therefore, this becomes the base case. C. Annual savings = 8000 + 42,000 – 15,000 – 20,000 = $15,000 ROI =
15, 000 × 100 = 7.5% 200, 000
This is an unacceptable ROI. Design C must be rejected. Design D is now compared to Design B which is the current base case. D. Annual savings = 21,000 + 52,500 – 10,000 – 25,000 = $38,500 ROI =
38, 500 × 100 = 15.4% 250, 000
This is an acceptable ROI. IROI =
38, 500 × 100 = 38.5% 100, 000
In this case, Design B produces nearly the same ROI and results in a better IROI. Select Design B and get a greater return on the incremental money.
9.3 THE EFFECT OF DEPRECIATION Depreciation is used to take into account the value of the equipment when it reaches obsolescence or must be replaced because of new technology. Assets before 1981 could be depreciated using the double declining balance method. From 1981 to 1986, the accelerated cost recovery system (ACRS) was used. Here all property was classified in 3-, 5-, 10-, 15-, or 20-year service life groups with no salvage value. The majority was in the 5-year group. A ½ full-year depreciation in the year placed in service was allowed; no deduction was granted in the year when property is disposed. From 1987 on, the modified accelerated cost recovery system (MACRS) has been used. This is the same as ACRS but also allows ½ of a full-year depreciation during the year of disposal. A 200% declining balance (i.e., double declining balance) for class lives of 3, 5, 7, and 10 years and a 150% depreciation for class lives of 15 and 20 years is allowed. A switch to straight-line depreciation at a time appropriate to maximize deduction is permitted. Straight-line depreciation, although no longer permitted, can be used to illustrate the effect of depreciation. The following definitions apply. VR = initial cost VS = salvage value © 2002 by CRC Press LLC
9588ch09 frame Page 105 Wednesday, September 5, 2001 9:50 PM
VA n a d
= = = =
asset value useful service life years in service annual depreciation d=
VR − VS = annual depreciation n
VS = VR − nd VA = VR − da or d =
(9.2) VR − VA a
As a part of the example below, the declining balance method will be used. This method is somewhat similar to the ACRS and MACRS, but is easier to see in an example. Here equipment depreciates rapidly over the first few years to minimize taxes during the initial period. The annual depreciation is a fixed percentage at the beginning of the depreciation year. f = annual depreciation at a fixed percentage factor VS = VR (1 − f )
n
VA = VR (1 − f )
a
9.3.1 AN EXAMPLE Companies P and Q bought identical Venturi scrubbers for $50,000. The service life of the scrubbers was eight years with no salvage value. The corporate tax rate is 34% for these companies. Company P uses the straight-line method of depreciation, and company Q uses the double declining-balance method. Compare the tax savings for these two companies for a period of 3 years. VR = initial cost = $50, 000 VS = salvage value = 0 n = useful service life = 8 years a = years in service = 3 years 34% tax rate — applied at end of year • Without depreciation, tax would be 0.34 × 50,000 = $17,000/year 3 × 17.000 = $51,000 over the 3 years © 2002 by CRC Press LLC
9588ch09 frame Page 106 Wednesday, September 5, 2001 9:50 PM
• Company P — straight-line depreciation d=
50, 000 − 0 = $6250 year 8
Tax Computation 1st year: 50,000 – 6250 = $43,750 2nd year: 43,750 – 6250 = $37,500 3rd year: 37,500 – 6250 = $31,250
Tax = $14,875 Tax = 12,750 Tax = 10,625
Total
$38,250
Savings = 51,000 – 38,250 = $12,750 • Company Q — double declining-balance depreciation First year factor =
VR − VS 1 n VR
First year factor =
50, 000 − 0 1 = 0.1250 50, 000 8
f = 2 × 0.1250 = 0.2500 Tax Computation 1st year: VR (1 – f) = 50,000 × 0.7500 = $37,500 Tax = $12,750 2nd year: VR (1 – f)2 = 50,000 × 0.5625 = $28,125 Tax = 9563 7172 3rd year: VR (1 – f)3 = 50,000 × 0.4219 = $21.094 Tax = Total
$29,485
Savings = 51,000 – 29,485 = $20,515 Obviously a method like the double declining-balance is favorable when computing taxes.
9.4 CAPITAL INVESTMENT AND TOTAL PRODUCT COST Numerous costs are required to build and operate a chemical plant other than installed equipment costs and operating costs. However, the usual cost estimation technique is to relate these costs to the installed equipment costs. Guthrie2 presents a capital cost-estimating technique which can be useful. Vatavuk3 also discusses a method for estimating capital and operating costs. He presents a table of factors which should be roughly valid at this time.
© 2002 by CRC Press LLC
9588ch09 frame Page 107 Wednesday, September 5, 2001 9:50 PM
9.4.1 DESIGN DEVELOPMENT In order to employ cost estimation and profitability analysis, it is suggested that the following process be used. 1. 2. 3. 4. 5. 6. 7.
Select a process to develop from alternative processes. Prepare the process flowsheet. Calculate sizes of all equipment and estimate fixed capital cost. Estimate installed cost. Determine utilities usage and estimate cost. Determine other costs — taxes, buildings, land, insurance. Undertake a profitability analysis.
In carrying out the design, it is recommended to set a budget for pollution control equipment. Then make as accurate a cost estimate as possible. Keep in mind maintaining a satisfactory profit structure if alternate choices are available. The following factors will affect equipment costs. • • • • •
Company policies Local and federal government regulations Design standards Union contracts and agreements Agreements with fabricators
REFERENCES 1. Peters, M. S. and Timmerhaus, K. D., Plant Design and Economics for Chemical Engineers, 4th ed., McGraw-Hill, Inc., New York, 1991. 2. Guthrie, K. M., Capital cost estimating, Chem. Eng., pp. 114, March 24, 1969. 3. Vatavuk, W. M. and Neveril, R. B., Factors for estimating capital and operating costs, Chem. Eng., pp. 157–162, November 3, 1980.
© 2002 by CRC Press LLC
9588ch10 frame Page 109 Wednesday, September 5, 2001 9:51 PM
10
Introduction to Control of Gaseous Pollutants
Under the auspices of the EPA Center for Environmental Research Information in conjunction with the EPA Control Technology Center, a handbook for design of hazardous air pollution control equipment was published in 1986. A revised version of the handbook was published in June 1991.1 Current information is furnished through the Clean Air Technology Center (CATC). This center serves as a resource on all areas of emerging and existing air pollution prevention and control technologies and their cost. The information now may be found on the Web at: http//www.usepa.gov/ttn/catc/. There are six main processes by which a gaseous pollutant may be removed from an air stream. Table 10.1, taken from the EPA handbook,1 lists those processes with the advantages and disadvantages of using each one. The table may be used as a guide to determine which process may provide the best means of cleaning the air stream. Separation processes are used as a means of air pollution control for both particulate matter and gas. These processes essentially remove the pollutant from the carrier gas resulting in a cleaned gas stream. If the pollutant content of the cleaned stream meets the effluent emission standards, the cleaned stream can be discharged to the atmosphere. Absorption and adsorption are both diffusional separation processes that can be used to collect hazardous air pollutants. In the case of absorption, the pollutant is transferred to the solvent which then may need further treatment. Recovery of the solvent might be undertaken by distillation or by stripping the absorbed material from the solvent. The problem of treating the waste material in the stream separated from the solvent remains. If the pollutant material has a value, adsorption may provide the means for the material to be more readily recovered. In the case of particulate matter, wet scrubbing collects the particles primarily through the mechanism of inertial impaction. Gaseous contaminants such as sulfur oxide, nitrogen oxide, or hydrochloric acid, if present along with the particulates, may be collected simultaneously by absorption. Many organic materials may be removed by condensation, which is essentially a diffusional operation. If a suitable coolant is available and the pollutant concentration is high enough, condensation can be very effective in recovering material that may be used again. For organic pollutants when the concentration is low or recovering the material is not desired, incineration can be used to convert the pollutant to carbon dioxide and water. For large emissions such as would be found in petroleum refineries the pollutant may be flared.
© 2002 by CRC Press LLC
9588ch10 frame Page 110 Wednesday, September 5, 2001 9:51 PM
TABLE 10.1 VOC Control Technologies Device Absorption
Adsorption
Condensation Thermal incineration
Inlet Conc. PPMV
Efficiency
250 1000 5000 200 1000 5000 500 10,000 20
90% 95% 98% 50% 90–95% 98% 50% 95% 95%
100
99%
50
90%
100
>95%
Catalytic incineration
Flares
>98%
Advantages
Disadvantages
Especially good for inorganic acid gasses
Limited applicability
Low capital investment Good for solvent recovery
Selective applicability Moisture and temperature constraints Limited applicability
Good for product or solvent recovery High destruction efficiency Wide applicability Can recover heat energy High destruction efficiency Can be less expensive than thermal incineration High destruction efficiency
No organics can be recovered Capital intensive No organics can be recovered Technical limitations that can poison No organics can be recovered Large emissions only
10.1 ABSORPTION AND ADSORPTION Both absorption and adsorption are diffusional processes employed in the cleanup of effluent gases before the main carrier gas stream is discharged to the atmosphere. Both of these operations are controlled by thermodynamic equilibrium. In pollution control, the concentrations of gases to be treated are relatively low. Thus, the equipment design is one in which it is reasonable to assume that gas is very dilute. In absorption it is quite likely that the liquid effluent will be dilute as well. Absorption of the contaminant from the dilute gas results in a chemical solution of the contaminating molecule. However, adsorption is a surface phenomenon in which the molecules of the contaminant adhere to the surface of the adsorbent. In diffusional operations where mass is to be transferred from one phase to another, it is necessary to bring the two phases into contact to permit the change toward equilibrium to take place. The transfer may take place with both streams flowing in the same direction, in which case the operation is called concurrent or co-current flow. When the two streams flow in opposite directions, the operation is termed countercurrent flow, an operation carried out with gas entering at the bottom and flowing upward, and the liquid entering at the top and flowing down. This process is illustrated in Figure 10.1. Figure 10.2 shows a combined operation in which the contaminated gas is first cleaned in a countercurrent operation, and then the gas is further treated to remove more of the contaminant in a co-current operation. © 2002 by CRC Press LLC
9588ch10 frame Page 111 Wednesday, September 5, 2001 9:51 PM
FIGURE 10.1 Countercurrent flow.
FIGURE 10.2 Combined countercurrent–co-current operation.
Countercurrent operation is the most widely used absorption equipment arrangement. As the gas flow increases at constant liquid flow, liquid holdup must increase. The maximum gas flow is limited by the pressure drop and the liquid holdup which © 2002 by CRC Press LLC
9588ch10 frame Page 112 Wednesday, September 5, 2001 9:51 PM
FIGURE 10.3 Cross-flow absorber operation.
will build up to flooding. Contact time is controlled by the bed depth and the gas velocity. In countercurrent flow, mass transfer driving force is maximum at the gas entrance and liquid exit. Co-current operation can be carried out at high gas velocities because there is no flooding limit. In fact, liquid holdup decreases as velocity increases. However, the mass transfer driving force is smaller than in countercurrent operation. Some processes for both absorption and the removal of particulates employ a cross-flow spray chamber operation. Here water is sprayed down on a bed of packing material. The carrier gas, containing pollutant gas or the particulate, flows horizontally through the packing, where the spray and packing cause the absorbed gas or particles to be forced down to the bottom of the spray chamber where they can be removed. Figure 10.3 illustrates a cross-flow absorber. The design of cross-flow absorption equipment is more difficult than vertical towers because the area for mass transfer is different for the gas and liquid phases. Continuous and steady-state operation is usually most economical. However, when smaller quantities of material are processed, it is often more advantageous to charge the entire batch at once. In fact, in many cases this is the only way the process can be done. This is called batch operation and is a transient operation from startup to shutdown. A batch operation presents a more difficult design problem. Adsorption is a semi-batch operation in which the contaminant in the carrier gas adheres
© 2002 by CRC Press LLC
9588ch10 frame Page 113 Wednesday, September 5, 2001 9:51 PM
to the absorbent until the adsorbent is saturated. The process must then be stopped to regenerate or replace the adsorbent. Absorption takes place in either a staged or continuous contactor. However, in both cases the flow is continuous. In the ideal equilibrium stage model, two phases are contacted, well mixed, come to equilibrium, and then are separated with no carryover. Real processes are evaluated by expressing an efficiency as a percent of the change that would occur in the ideal stages. Any liquid carryover is removed by mechanical means. In the continuous absorber, the two immiscible phases are in continuous and tumultuous contact within a vessel which is usually a tall column. A large surface is made available by packing the column with ceramic or metal materials. The packing provides more surface area and a greater degree of turbulence to promote mass transfer. The penalty for using packing is the increased pressure loss in moving the fluids through the column, causing an increased demand for energy. In the usual counter-current flow column, the lighter phase enters the bottom and passes upward. Transfer of material takes place by molecular and eddy diffusion processes across the interface between the immiscible phases. Contact may be also co-current or cross-flow. Columns for the removal of air contaminants are usually designed for counter-current or cross-flow operation.
10.1.1 FLUID MECHANICS TERMINOLOGY Defining velocity through a column packed with porous material is difficult. Even if a good measure of porosity has been made, it is not possible to assure that the same porosity will be found the next time a measurement is made after the packing has been changed. Also, during operation the bed may expand or in the case of a two-phase, gas-liquid operation, liquid holdup can occur which varies with the flow. Therefore, determining the unoccupied tower cross-sectional area is difficult, and it becomes advantageous to base the velocity on the total tower cross-section which is the usual way to calculate tower flow, especially in absorption design. The conservation of mass principle at steady state is m = ρA V
(10.1)
where m = mass flow rate ρ = mass density A = area — V = mean velocity in compatible units. If G is defined as the mass rate of gas flow, then a superficial mass velocity can be defined as G where G=G A
© 2002 by CRC Press LLC
(10.2)
9588ch10 frame Page 114 Wednesday, September 5, 2001 9:51 PM
Note that the mean velocity can be calculated from V = m ρA
(10.3)
and that the volumetric flow rate Q is given by Q = AV
(10.4)
V=Q A
(10.5)
Thus
defines a superficial velocity which is dependent upon the total tower cross-sectional area.
10.1.2 REMOVAL OF HAP AND ADSORPTION
AND
VOC
BY
ABSORPTION
Absorption is widely used as a product-recovery method in the chemical and petroleum industry. As an emission control technique, it is more commonly employed for inorganic vapors. Some common absorption processes for inorganic gases are • • • • •
Hydrochloric acid vapor in water Mercury vapor in brine and hypochlorite solution Hydrogen sulfide vapor in sodium carbonate and water Hydrofluoric acid vapor in water Chlorine gas in alkali solution
In order for absorption to be a suitable process for emission control, there must be a suitable solvent which can readily be treated after it leaves the process. Both vapor–liquid equilibrium data and mass-transfer data must be available or capable of being estimated. Absorption may be most effective when combined with other processes such as adsorption, condensation, and incineration. Adsorption can be used to treat very dilute mixtures of pollutant and air. Activated carbon is the most widely used adsorbent. Silica gel and alumina are also frequently used adsorbents. Removal efficiencies can be as high as 99%. The maximum inlet concentration should be about 10,000 ppmv with a usual minimum outlet concentration at 50 ppmv. In some cases it may be advisable to design for minimum outlet concentration of 10 to 20 ppmv. The maximum concentration entering an adsorption bed is limited by the carbon capacity and in some cases by bed safety. Exothermic reactions can occur when some compounds are mixed in an adsorption bed. Thus, if concentrations are too high, the bed may reach a flammable condition which could lead to an explosion. It is best to keep the entering concentration to less than 25% of the Lower Explosive Limit (LEL). For excessively high concentrations, condensation or dilution could be used to bring the concentration to a more reasonable lower level. © 2002 by CRC Press LLC
9588ch10 frame Page 115 Wednesday, September 5, 2001 9:51 PM
Other limitations for adsorption operation are concerned with the molecular mass of the adsorbate. High molecular weight compounds are characterized by low volatility and are strongly adsorbed. Adsorption technology should be limited to compounds whose boiling points are below 400°F or molecular mass is less than about 130. Strongly adsorbed high-molecular-mass compounds are difficult to remove when regenerating the adsorbent. With low molecular mass, compounds below a molecular mass of 45 are not readily adsorbed due to their high volatility. On the other hand, lower molecular-weight compounds are more readily removed during the regeneration process. Furthermore, gases to be treated may have liquid or solid particles present or have a high humidity. Pretreatment may then be required. Humidity needs to be reduced below 50% in most cases, or the water will selectively adsorb to such a great extent that the desired adsorbate to be removed will be blocked out. Gases to be treated may also be required to be cooled if the temperature is greater than 120–130°F and the possibility of exothermic reactions exist.
REFERENCE 1. U.S. EPA Handbook: Control Technologies for Hazardous Air Pollutants, EPA/625/691/014, Cincinnati, OH, 1991.
© 2002 by CRC Press LLC
9588ch11 frame Page 117 Tuesday, September 11, 2001 10:16 AM
11
Absorption for HAP and VOC Control
11.1 INTRODUCTION Absorption is a diffusional mass-transfer operation by which a soluble gaseous component is removed from a gas stream by dissolution in a solvent liquid.1 The driving force for mass transfer is the concentration difference of the solute between the gaseous and liquid phases. In the case of absorption this driving force can be interpreted as the difference between the partial pressure of the soluble gas in the gas mixture and the vapor pressure of the solute gas in the liquid film in contact with the gas. If the driving force is not positive, no absorption will occur. If it is negative, desorption or stripping will occur and the concentration of the pollutant in the gas being treated will increase. Absorption systems can be divided into those that use water as the primary absorbing liquid and those that use a low volatility organic liquid. The system can be simple absorption in which the absorbing liquid is used in a single pass and then disposed of while containing the absorbed pollutant. Alternatively, the pollutant can be separated from the absorbing liquid and recovered in a pure, concentrated form by distillation or stripping (desorption). The absorbing liquid is then used in a closed circuit and is continuously regenerated and recycled. Examples of regeneration alternatives to distillation or stripping are pollutant removal through precipitation and settling; chemical destruction through neutralization, oxidation, or reduction; hydrolysis; solvent extraction; and pollutant liquid adsorption.
11.2 AQUEOUS SYSTEMS Absorption is one of the most frequently used methods for removal of water-soluble gases. Acidic gases such as HCI, HF, and SiF4 can be absorbed in water efficiently and readily, especially if the last contact is made with water that has been made alkaline. Less soluble acidic gases such as SO2, C12, and H2S can be absorbed more readily in a dilute caustic solution. The scrubbing liquid may be made alkaline with dissolved soda ash or sodium bicarbonate, or with NaOH, usually no higher a concentration in the scrubbing liquid than 5 to 10%. Lime is a cheaper and more plentiful alkali, but its use directly in the absorber may lead to plugging or coating problems if the calcium salts produced have only limited solubility. A technique often used is the two-step flue gas desulfurization process, where the absorbing solution containing NaOH is used inside the absorption tower, and then the tower
© 2002 by CRC Press LLC
9588ch11 frame Page 118 Tuesday, September 11, 2001 10:16 AM
effluent is treated with lime externally, precipitating the absorbed component as a slightly soluble calcium salt. The precipitate may be removed by thickening, and the regenerated sodium alkali solution is recycled to the absorber. Scrubbing with an ammonium salt solution can also be employed. In such cases, the gas is often first contacted with the more alkaline solution and then with a neutral or slightly acid contact to prevent stripping losses of NH3 to the atmosphere. When flue gases containing CO2 are being scrubbed with an alkaline solution to remove other acidic components, the caustic consumption can be inordinately high if CO2 is absorbed. However, if the pH of the scrubbing liquid entering the absorber is kept below 9.0, the amount of CO2 absorbed can be kept low. Conversely, alkaline gases, such as NH3, can be removed from the main gas stream with acidic water solutions such as dilute H2SO4, H3PO4, or HNO3. Single-pass scrubbing solutions so used can often be disposed of as fertilizer ingredients. Alternatives are to remove the absorbed component by concentration and crystallization. The absorbing gas must have adequate solubility in the scrubbing liquid at the resulting temperature of the gas–liquid system. For pollutant gases with limited water solubility, such as SO2 or benzene vapors, the large quantities of water that would be required are generally impractical on single-pass basis, but may be used in unusual circumstances. An early example from the U.K. is the removal of SO2 from flue gas at the Battersea and Bankside electric power stations, described by Rees.2 Here the normally alkaline water from the Thames tidal estuary is used in large quantity on a one-pass basis.
11.3 NONAQUEOUS SYSTEMS Although water is the most common liquid used for absorbing acidic gases, amines (monoethanol-, diethanol-, and triethanolamine; methyldietnolamine; and dimethylanaline) have been used for absorbing SO2 and H2S from hydrocarbon gas streams. Such absorbents are generally limited to solid-particulate-free systems, because solids can produce difficult to handle sludges as well as use up valuable organic absorbents. Furthermore, because of absorbent cost, absorbent regeneration must be practiced in almost all cases. At first glance, an organic liquid appears to be the preferred solvent for absorbing hydrocarbon and organic vapors from a gas stream because of improved solubility and miscibility. The lower heat of vaporization of organic liquids is an energy conservation plus when solvent regeneration must occur by stripping. Many heavy oils, No. 2 fuel oil or heavier, and other solvents with low vapor pressure can do extremely well in reducing organic vapor concentrations to low levels. Care must be exercised in picking a solvent that will have sufficiently low vapor pressure that the solvent itself will not become a source of VOC pollution. Obviously, the treated gas will be saturated with the absorbing solvent. An absorber–stripper system for recovery of benzene vapors has been described by Crocker.3 Other aspects of organic solvent absorption requiring consideration are stability of the solvent in the gas–solvent system, for example its resistance to oxidation, and possible fire and explosion hazards.
© 2002 by CRC Press LLC
9588ch11 frame Page 119 Tuesday, September 11, 2001 10:16 AM
11.4 TYPES AND ARRANGEMENTS OF ABSORPTION EQUIPMENT Absorption requires intimate contact between a gas and a liquid.4 Usually means are provided to break the liquid up into small droplets or thin films, which are constantly renewed through turbulence to provide high liquid surface area for mass transfer as well as a fresh, unsaturated surface film for high driving force. The most commonly used devices are packed and plate columns, open spray chambers and towers, cyclonic spray chambers, and combinations of sprayed and packed chambers. Some of these devices are illustrated in Figures 10.1, 10.2, and 10.3. Additional illustrations of absorption equipment are shown in Figures 11.1 to 11.5. Packed towers give excellent gas–liquid contact and efficient mass transfer. For this reason, they can generally be smaller in size than open spray towers. A countercurrent packed tower maximizes driving force, because it brings the least concentrated outlet gas into contact with fresh absorbing liquid. These features make this type of tower design the best choice when the inlet gas is essentially free of solid particulates. However, packed towers plug rapidly when appreciable insoluble particulates are present. The cross-flow packed scrubber is more plug resistant when properly designed.5 In plate columns, contact between gas and liquid is obtained by forcing the gas to pass upward through small orifices, bubbling through a liquid layer flowing across a plate. The bubble cap tower is a classical contacting device. A variation is the valve tray, which permits greater variations in gas flow rate without dumping the liquid through the gas passages. Sieve plates are simple flat plates perforated with small holes. The advantages are low cost and high plate efficiency, but they have narrow gas flow operating ranges. Spray chambers and towers are considerably more resistant to plugging when solid particulates are present in the inlet gas. However, difficulties with plugging in spray towers and erosion can be troublesome when the spray liquid is recycled. Particle settling followed by fine strainers or even coarse filters is beneficial. Another tower contacting device for absorption is the baffle tower, which has been employed occasionally when plugging and scaling problems are expected to be severe. Gases passing up the tower must pass through sheets downwardly cascading liquid, providing some degree of contact and liquid atomization. Baffle tower design may use alternating segmental baffles (Figure 11.4) or disk and doughnut plates, in which the gas alternately flows upward through central orifices and annuli, traversing through liquid curtains with each change in direction. Mass transfer is generally poor, and information on design parameters is extremely scarce.
11.5 DESIGN TECHNIQUES FOR COUNTERCURRENT ABSORPTION COLUMNS Although the design of co-current and cross-flow towers are important, countercurrent towers are the most frequently used. Moreover, the design of cross-flow towers involves complicated calculations which do not enhance the theory of tower design. Therefore, the principles of design of the countercurrent tower will be explained in more detail.
© 2002 by CRC Press LLC
9588ch11 frame Page 120 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.1 Packed column with all equipment.
The two main factors to be determined in countercurrent absorption column design are the height of packing influenced by the mass-transfer conditions, and the tower diameter, influenced by the flow rate of the gas to be treated. Size and type of packing affects both the mass-transfer conditions and the pressure loss through the column. Height of packing is determined by the rate of mass transfer from one phase to another. The amount of mass transferred is equal to the rate of mass transfer times
© 2002 by CRC Press LLC
9588ch11 frame Page 121 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.2 Spray chamber.
the time of contact. The time of contact is dependent upon column size and flow rates. For a very high tower, one might expect that most of the pollutant in the gas stream can be removed. Tower diameter is determined by the quantity of gas passing up the tower. The upper limit of flow occurs when the tower begins to flood. Most efficient mass transfer occurs at flow rates just short of flooding. Higher flow rates result in higher pressure losses. Thus an economic optimum column size could be established, if cost data and information regarding mass transfer and pressure loss as a function of flow rate are known. Because we are dealing with dilute solutions in the case of pollution removal from an effluent, the heat of solution will most usually be negligible. Therefore, we will assume that air contaminant absorption columns operate isothermally, and the design equations presented in this chapter will be for the isothermal, dilute gas case.
© 2002 by CRC Press LLC
9588ch11 frame Page 122 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.3 Cyclonic spray chamber.
11.5.1 EQUILIBRIUM RELATIONSHIPS For a very detailed introductory discussion of phase equilibria see the text by Smith, van Ness, and Abbott.6 Vapor–liquid equilibria for miscible systems is determined from the equality of fugacity in both phases at the same temperature and pressure: fˆi v = fˆi L
(11.1)
For component i in the liquid phase: fˆi L = x i γ i fi o
© 2002 by CRC Press LLC
(11.2)
9588ch11 frame Page 123 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.4 Plate column.
© 2002 by CRC Press LLC
9588ch11 frame Page 124 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.5 Baffle tray tower.
and in the vapor phase fˆi v = y i φi P
(11.3)
According to Equation 11.1, therefore: y i φi P = x i γ i fio
(11.4)
This system is structured so that only the fugacity coefficient φi and the activity coefficient γi depend upon the compositions at any given temperature and pressure. The standard state fugacity f oi is a property of the pure component only. The Gibbs–Duhem equation which involves partial molar solution properties is extremely useful in dealing with phase equilibria. It can be written as follows for n components, © 2002 by CRC Press LLC
9588ch11 frame Page 125 Tuesday, September 11, 2001 10:16 AM
∂M ∂M dT + dP − ∂T P ∂P T
n
∑ x d(ln M ) = 0 i
i
(11.5)
i
— Here M is a solution property M i and is the corresponding partial molar property. By using excess Gibbs free energy changes, this equation can be written in terms of the enthalpy and volume changes on mixing ∆H and ∆V, respectively, and the activity coefficient:
−
∆H ∆V dT + dP = RT 2 RT
n
∑ x d(ln γ ) i
i
(11.6)
i
In the case of solutions of nonpolar molecules or for solutions at low concentration, the enthalpy and volume changes on mixing are small and Equation 11.6 for a binary mixture becomes: x i d(ln γ 1 ) + x 2 d(ln γ 2 ) = 0
(11.7)
For a solution at low pressure where the vapor is an ideal gas, and presuming f oi to be equivalent of the pure component fugacity at the temperature and pressure of the solution, Equation 11.7 can be rewritten at constant temperature: x1d ln(y1P ) + x 2 d ln(y 2 P ) = 0
(11.8)
Note that (y1P) = P1 and (y2P) = P2, the partial pressures, and x2 = 1 – x1, therefore, P2
P1
∫ d(ln P ) = −∫ d(ln P ) 2
1
P2o
P ln 2o = − P2
(11.9)
0
P2
∫ (1 − x ) P x1
0
dP1
1
(11.10)
1
Therefore, from partial pressure data of one component of a binary solution, the partial pressure of the second component may be calculated. Use of this technique is recommended when limited experimental data are available.
11.5.2 IDEAL SOLUTIONS — HENRY’S LAW A general relationship for fugacity of a component in a liquid mixture in terms of the pure component fugacity is given by the following equation: © 2002 by CRC Press LLC
9588ch11 frame Page 126 Tuesday, September 11, 2001 10:16 AM
fˆ 1 ln i L = x f RT ii
P
∫ (V − V ) dP i
(11.11)
i
0
—
According to Amagat’s Law, an ideal solution is one in which (Vi – Vi = 0), and the value of the integral in Equation 11.11 is also zero. This makes fˆi L = fi id = x i fi L
(11.12)
for an ideal solution. This relationship is known as the Lewis and Randall Fugacity Rule. More generally to be consistent with Equation 11.2, the ideal fugacity would be defined as: fi id = x i fio
(11.13)
where f oi is the fugacity of component i in the standard state at the same temperature and pressure of the solution. If the standard states adopted were that of the pure substance designated by i, then f oi = fi . Equation 11.13 is plotted in Figure 11.6 in such a manner that both broken lines are valid representations of the equation. Each broken line represents one model of the ideal solution while the solid line represents the value of fˆ iL for a real solution
FIGURE 11.6 Defining Henry’s Law and the Lewis and Randall Fugacity Rule in relation to the true fugacity.
© 2002 by CRC Press LLC
9588ch11 frame Page 127 Tuesday, September 11, 2001 10:16 AM
as given by Equation 11.11. From the figure, it can be seen that while f oi(A) and f oi(B) are both fugacities of pure component i, only f oi(A) represents the fugacity of a pure component as it actually exists. Thus, f oi(B) represents an imaginary state of the real solution. In either case the broken line is drawn tangent to the solid curve for the real solution where it meets the curve. Real solution behavior is represented by f oi(A) as xi → 1.0, and by f oi(B) as xi → 0.0. Then, fˆ L lim i = fio (A) = fi x i → 1.0 x i
(11.14)
Henry’s Law, which is valid for a dilute solution, may be defined as follows. fˆ L lim i = k = fio (B) x i → 0.0 xi
(11.15)
Equation 11.15 can be written as fˆi L = x i k i
(11.16)
where ki is Henry’s Law constant. Equation 11.4 can now be written, y i φˆ i P = x i k i
(11.17)
— For solutions at low pressure φˆ i ≈ φi ≈ 1.0 and yiP = Pi , thus,
Pi = x i k i
(11.18)
which is a more common form of Henry’s Law. The composition xi could be expressed as a weight fraction as well as a mole fraction. However, k must have — i units to make the equation consistent in units. Noting that yiP = Pi is the partial pressure and putting Equation 11.18 into mole fraction terms on both sides of the equation, results in the following equation: yi =
ki x P i
(11.19)
Define m = ki/P and a common definition for Henry’s Law constant, and Equation 11.19 becomes yi = mixi
© 2002 by CRC Press LLC
(11.20)
9588ch11 frame Page 128 Tuesday, September 11, 2001 10:16 AM
an equation which has application to the case of absorption of dilute solutions. Henry’s Law is an adequate method of representing vapor–liquid phase equilibria for many dilute solutions encountered in absorption work. However, in the case of weak electrolytes, dissociation of the electrolyte may take place upsetting the normal equilibrium relationship. In this case, Henry’s Law must be altered.
11.5.3 COUNTERCURRENT ABSORPTION TOWER DESIGN EQUATIONS Figure 11.7 illustrates a packed absorption tower with countercurrent flow. A mass balance is made around a cross-section through the tower assuming that the gas and liquid molar flow rates are constant. Making a differential mass balance around the tower in molar units, y A G + x A L = (ya − dy A ) G + (x a + dx a ) L
(11.21)
FIGURE 11.7 Packed tower definitions: L and G = molar flow rates, x and y = mole fractions. © 2002 by CRC Press LLC
9588ch11 frame Page 129 Tuesday, September 11, 2001 10:16 AM
This equation can be reduced to the following. Gdy A = Ldx A
(11.22)
If it is assumed that the flow rates do not remain constant through the column, Equation 11.22 can be written as, d(Gy A ) = d( Lx A )
(11.23)
This equation can now be integrated from the top of the column down to the tower cross-section AA. y A G − y A1G1 = x A L − x A1L1
(11.24)
A common practice for solution of the equations for general use, especially when dilute solutions are not expected, is to rewrite the flow rates on a solute-free basis. The following equations present these solute-free flow rates designated by the subscript B. G B = (1 − y A ) G = (1 − y A1 ) G A1 L B = (1 − x A ) L = (1 − x A1 ) L A1
(11.25)
The material balance of Equation 11.24 can be rewritten in terms of these solutefree flow rates as, yA x A1 xA y A1 1 − y GB + 1 − x LB = 1 − x LB + 1 − y GB A1 A A1 A
(11.26)
For dilute solutions such as found in most air pollution control conditions,
(1 − yA ) ≈ 1.0, (1 − x A1 ) ≈ 1.0, etc. and G B ≈ G ≈ G A1 L B ≈ L ≈ L A1 Equation 11.26 reduces to Equation 11.24 which is called the “operating line” since it represents concentrations in an operating absorption column. Equation 11.26 is a general equation which can be used along with a general equilibrium relationship © 2002 by CRC Press LLC
9588ch11 frame Page 130 Tuesday, September 11, 2001 10:16 AM
such as Equation 11.4. For this case of a dilute solution, Equation 11.24 will be used along with Henry’s Law Equation 11.20, yA* = m xA* . Both the equilibrium line, 11.20, and the operating line, 11.24, will plot as a straight line on an x–y plot.
11.5.4 ORIGIN
OF
VOLUME-BASED MASS-TRANSFER COEFFICIENTS
Interphase mass transfer takes place due to a difference of concentration across the interface between phases. Several important theories have been devised to describe this transport by Higbie1 and Dankwerts.7 These theories serve as a realistic description of the dynamic activities at the interface between two fluids. However, the Whitman8 “two-film” concept remains an excellent basis for defining mass transfer coefficients and as a picture of interfacial action. 11.5.4.1 Steady-State Molecular Diffusion Molecular diffusion serves as a basis for an initial definition of mass transfer coefficients. Molecular diffusion appears as a random motion of molecules in which a net movement of molecules takes place from a region of high concentration to a region of low concentration. The driving force for diffusion across the interface can be considered to be due to the difference in concentration. This driving force continues to act until the concentrations are the same through the vessel containing the molecule. When there is no concentration, temperature, or pressure difference in the areas of the diffusion, it is assumed that complete thermodynamic equilibrium has been achieved. In molecular diffusion, we can assume that only one component is in motion across the interface. Molecular diffusivity is interpreted in terms of a relative velocity of the diffusing component with respect to an average velocity of the entire stream in a direction normal to the interface. Mass transfer of component A in a mixture with component B is depicted as a movement to or from a fixed surface that is parallel to the interface and stationary in relation to the interface. The molecular motion is accounted for by Fick’s Law and the total flux is the sum of the molecular diffusion and the convective bulk flow. Defining NA as the flux of component A with the units of moles per unit time per unit area, and NB similarly for component B, the bulk flux is given by N bulk = N A + N B
(11.27)
Then for component A with mole fraction yA, the sum of the bulk flux and the flux due to molecular diffusion in the z direction is given by N A = y A ( N A + N B ) − D ABρm
dy A dz
where DAB is the molecular diffusivity and ρm is the density of the gas.
© 2002 by CRC Press LLC
(11.28)
9588ch11 frame Page 131 Tuesday, September 11, 2001 10:16 AM
In the case of absorption of a single component A, it is assumed that A is diffusing through a stagnant layer of B, thus NB = 0.0. Equation 11.22 then can be rearranged and integrated over a distance L with the following boundary conditions, y A = y AO when z = 0.0 y A = y AL when z = L The result is NA =
D ABρm 1 − y AL ln L 1 − y AO
(11.29)
y AO + y BO = 1.0
(11.30)
y AL + y BL = 1.0
(11.31)
Because
and
a logarithmic mean concentration can be defined, y BM =
(yBO − yBL ) = (yAO − yAL ) ln(y BO y BL ) 1 − y AL ln
(11.32)
1− y AO
Then a mass transfer coefficient can be defined as k my =
D ABρm Ly BM
(11.33)
and Equations 11.32 and 11.33 can be substituted into Equation 11.29, N A = k my (y AO − y AL )
(11.34)
11.5.5 THE WHITMAN TWO-FILM THEORY Mass transfer in real absorption equipment resembles a molecular diffusion process only in the basic idea of a concentration difference driving force. However, the Whitman8 two-film theory can be used to construct a model similar in many respects
© 2002 by CRC Press LLC
9588ch11 frame Page 132 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.8 Whitman two-film theory: yA = mole fraction of A in bulk gas stream; xA = mole fraction of A in the bulk liquid stream; yAi = mole fraction of A in the gas film at the interface; xAi = mole fraction of A in the liquid film at the interface; and yAi = mxAi .
to the molecular diffusion equations. Figure 11.8 is a schematic representing the Whitman two-film theory. The theory may be summarized as follows. 1. Visualize two films, the gas film and the liquid film, on either side of the interface. 2. Material is transferred in the bulk of the phases by convection currents. Concentration differences are negligible except in the vicinity of the interface. 3. On each side of the interface, convection currents die out and the two thin films form. 4. Both films offer resistance to mass transfer. Transfer takes place through these films by a mechanism similar to molecular diffusion. 5. The interface is at equilibrium and offers no resistance to mass transfer. 6. There is uniform composition in the main stream. 7. At the interface, yAi and xAi are considered to be in equilibrium described by Henry’s Law, yAi = mxAi , where mi = Henry’s Law Constant. In a packed absorption column, the fluid is in turbulent motion. Mass transfer through the films is defined by ky and kx which are now turbulent mass transfer coefficients. An equation similar to 11.29 for molecular diffusion can be used to describe the mass transfer. However, the concentration difference is expressed in terms of mole fractions at the interface. N A = k y (y A − y Ai ) = k x (x Ai − x A )
© 2002 by CRC Press LLC
(11.35)
9588ch11 frame Page 133 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.9 Illustrating new pseudo-equilibrium mole fractions.
11.5.6 OVERALL MASS-TRANSFER COEFFICIENTS Mass-transfer coefficients defined on the basis of interfacial mole fractions have little practical value since these mole fractions cannot be measured. A new masstransfer coefficient can be defined which can be determined from measured data. Two new pseudo-mole fractions are defined as illustrated in the Figure 11.9. Overall mass transfer coefficients Ky and Kx are defined based on these new pseudo-mole fractions. yA* = equilibrium mole fraction of the solute in the vapor corresponding to the mole fraction xA in the liquid xA* = equilibrium mole fraction of the solute in the liquid corresponding to the mole fraction yA in the vapor and the mass transfer may now be written
(
)
(
N A = K y y A − y A* = K x x A* = x A
)
(11.36)
The mass balance line is termed the operating line and this line and the equilibrium curve are both plotted in Figure 11.9. The construction in the figure illustrates how to determine yA* for any yA, and for any xA. The overall coefficients can be related to the individual phase coefficients making use of Henry’s Law. Equations 11.35 and 11.36 then can be equated.
© 2002 by CRC Press LLC
9588ch11 frame Page 134 Tuesday, September 11, 2001 10:16 AM
(
)
N A = K y y A − y A* = k y (y A − y Ai ) = k x (x Ai − x A ) =
(
kx y − y A* m Ai
)
(11.37)
also
(
N A = K y y A − y Ai + y Ai − y A*
)
(11.38)
Then combining Equations 11.37 and 11.38, N mN A NA = K y A + k x ky
(11.39)
Then dividing both sides of the Equation 11.39 by NA and rearranging, 1 1 m = + Ky ky kx
(11.40)
11.5.7 VOLUME-BASED MASS-TRANSFER COEFFICIENTS Absorption towers are packed with plastic, metal, or ceramic pieces to provide a greater area for contact between the vapor and liquid phases. Each of these packings has a characteristic area per unit volume of packing which can be denoted by the quantity “a,” where a=
interfacial area unit volume
Flow rate of both phases, viscosity, density, surface tension, and size and shape of the packing determine the value of “a.” These same factors affect the value of the mass transfer coefficients Ky and Kx. Therefore, it is expedient to include “a” in the mass transfer equation and define two new quantities Kya and Kxa. These quantities would then be correlated with the solution parameters as functions of various chemical systems. If A is the absorption tower cross-sectional area, and z the packing height, then Az is the tower packing volume. Defining Ai as the total interfacial area: A i = aAz
(11.41)
dA i = aAdz
(11.42)
or in differential form
We can now rewrite Equation 11.36 in terms of a differential rate of mass transfer dNA, with units (moles/unit time) = (moles/unit time – area) × (area), © 2002 by CRC Press LLC
9588ch11 frame Page 135 Tuesday, September 11, 2001 10:16 AM
(
)
dN A = N A dA i = K y y A − y A* aAdz
(11.43)
or
(
)
(
)
dN A = K ya y A − y A* Adz = K xa x A − x A* Adz
(11.44)
Equation 11.44 defines the volumetric mass transfer coefficients Kya and Kxa which have the typical units moles/(h-m3-mole fraction). Note also that the term Adz represents the differential packed tower volume.
11.5.8 DETERMINING HEIGHT THE HTU METHOD
OF
PACKING
IN THE
TOWER:
The differential rates of mass transfer given by Equation 11.44 is equal to the differential rate of change of mass Equation 11.23 within a phase. Then for the gas phase, the differential rate of mass transfer of component A is equal to the differential rate of change of the mass of A in the incoming gas stream. dN A = d(Gy A )
(11.45)
Rewriting Equation 11.25 where GB is a constant, G B = (1 − y A ) G
(11.46)
G y d(Gy A ) = d B A (1 − y A )
(11.47)
G y Gdy A d B A = (1 − y A ) (1 − y A )
(11.48)
then
It can be shown that
Therefore, Gdy A
(1 − yA )
(
)
= K ya y A − ya* Adz
(11.49)
becomes the basic design equation. A similar equation based on the liquid phase can be written which would be useful in stripping calculations. © 2002 by CRC Press LLC
9588ch11 frame Page 136 Tuesday, September 11, 2001 10:16 AM
We now define a mass transfer coefficient Kyo which is independent of concentration: Ky =
K oy
(11.50)
(1 − yA )LM
where (1 – yA) LM is the log mean concentration defined by
(1 − yA )LM =
(1 − yA ) − (1 − yA* ) (1 − y A ) ln
(
(11.51)
)
* 1 − y A
Define set of flow rates based on tower cross section G=
G L and L = A A
(11.52)
Then rewrite Equation 11.49, dy A Ky oAa G y − y A* dz = 1 − y A (1 − y A )LM
(
)
(11.53)
Assuming constant flow rate, G, through the column, this equation can now be integrated from z = 0 to z = z down the column to determine tower height. G z= o K ya
yA 0
(1 − yA )LM
∫ (1 − y ) (y
y A1
A
A
− y A*
)
dy A
(11.54)
The ratio of flow rate to mass transfer has been designated as the height of a transfer unit (HTU), or, for the gas phase, HOG. G H OG = o K ya
(11.55)
Therefore, HOG has been defined in such a way that it remains constant through the absorption column. The integral portion of Equation 11.54 is designated as the number of overall mass transfer units (NTU), or, for the gas phase, NOG. Thus yA 0
N OG =
∫
y A1
© 2002 by CRC Press LLC
(1 − yA )LM dy (1 − yA ) (yA − yA* ) A
(11.56)
9588ch11 frame Page 137 Tuesday, September 11, 2001 10:16 AM
The integral may be evaluated by graphical or numerical techniques. The height of the column may now be calculated from z = H OG N OG
(11.57)
11.5.9 DILUTE SOLUTION CASE For dilute solutions, Henry’s Law is usually a good choice for an equilibrium relationship. In this case, yA* = mxA which is associated with the overall mass-transfer coefficient as defined in Equation 11.36. For a dilute solution,
(1 − yA ) ≈ (1 − yA )LM ≈ 1.0
(11.58)
and Equation 11.56 reduces to yA 0
N OG =
∫ (y
y A1
dy A * A − yA
(11.59)
)
The operating line, Equation 11.24, may now be rewritten as L y A = (x A − x A1 ) + y A1 G
(11.60)
Rewrite Equation 11.60, multiplying and dividing by Henry’s Law constant, m, L yA = mx − mx A1 ) + y A1 mG ( A
(11.61)
– – Note that the ratio L/G = L/G. Then the absorption factor, Ab, can be defined as Ab =
L L = mG mG
(11.62)
Then rewrite Equation 11.61 using Henry’s Law and the absorption factor and solve for yA* y A* =
y A − y A1 + mx A1 Ab
(11.63)
Substitute Equation 11.63 in Equation 11.59 and integrate
N OG =
© 2002 by CRC Press LLC
ln
[((y
A0
)
]
− mx A1 ) (y A1 − mx A1 ) (1 − 1 Ab) + (1 Ab)
(1 − 1 Ab)
(11.64)
9588ch11 frame Page 138 Tuesday, September 11, 2001 10:16 AM
When a pure solvent such as water is used, xa1 = 0.0, and Equation 11.64 reduces to 1 N OG = ln (y A 0 y A1 ) (1 − 1 Ab) + 1 Ab 1 − 1 Ab
[
]
(11.65)
11.6 COUNTERCURRENT FLOW PACKED ABSORPTION TOWER DESIGN 11.6.1 GENERAL CONSIDERATIONS Filters, heat exchangers, dryers, bubble cap columns, cyclones, etc. are ordinarily designed and built by process equipment manufacturers. However, units of special design for one-of-a-kind operations such as packed absorption cleanup towers are quite often designed and built under the supervision of plant engineers. Thus, there is a large variety of this type of equipment, none of it essentially standard. When a packed tower is designed for treating a given quantity of gas per hour, the height of packing is determined from mass transfer considerations, and the diameter or cross-sectional area is determined by the gas velocity in the empty tower cross-section. The smaller the diameter of the tower, the higher the gas velocity will be, which will help the gas to overcome the tower pressure drop. This could result in a lower cost of pushing the gas through the packed tower. The chief economic factors to be considered in design are listed in Table 11.1.
11.6.2 OPERATIONS
OF
PACKED TOWERS
In the past, absorbers operating as cleanup towers to remove undesirable gaseous effluents were customarily called scrubbers. At that time most of the gases being removed were acid gases being scrubbed with water. The designation of scrubber to scrub the discharge gas and clean it seemed rather natural. Today we carry out the same kind of operation, but with more stringent regulations imposed by the local
TABLE 11.1 Economic Factors in Packed Tower Design: Operating and Capital Cost Factors Operating Costs Pumping power for gas and liquid Labor and maintenance Steam and cooling water Loss of unabsorbed material Disposal of absorbed material Solvent makeup Solvent purification
© 2002 by CRC Press LLC
Capital Costs Tower and shell packing Packing support Gas and liquid distributor Pumps, blowers, and compressors Piping and ducts Heat exchanger Solvent recovery system
9588ch11 frame Page 139 Tuesday, September 11, 2001 10:16 AM
FIGURE 11.10 Pressure drop vs. superficial gas mass velocity with superficial liquid mass velocity as the parameter for 3 in. Intalox® ceramic saddles. (Courtesy of Saint-Gobain NorPro Corporation, Akron, Ohio.)
air pollution control agency. Since we now also have more stringent regulations imposed for the removal of particulate matter in effluents, the term scrubber will be applied to those operations in this book which may also include the simultaneous removal of gaseous pollutants. Therefore, in this book the term “absorber” will refer to the removal of gaseous contaminants. Most gas absorption columns are operated as countercurrent contactors with gas entering at the bottom and the liquid at the top. In a packed tower operating in countercurrent flow at constant liquid rate, the pressure drop varies with the gas mass velocity. With liquid holdup in the packing, there is smaller void space in the column, and a higher pressure drop exists than with dry packing. A typical set of pressure drop curves is shown in Figure 11.10. It can be seen that at low gas flow rates the liquid flow rate lines are nearly parallel to the dry line up to high liquid flow rates. Figure 11.10 shows a continually increasing pressure drop with gas flow at any liquid flow rate until the slope of the curve become infinite. The point at which the rate of change of pressure drop increases more rapidly than a constant value has been called the upper loading point. The liquid holdup is now increasing with the increasing gas rate. Above the loading region the column will approach the maximum hydraulic capacity at the point where the slope becomes infinite. This is the upper limit to the gas rate. The velocity corresponding to this upper limit is known as the flooding velocity. Flooding can be observed as a crowning of the packing which begins at the bottom and progresses to the top of the packing where a layer of liquid is visible above the packing. At gas rates greater than the flooding velocity, the column will © 2002 by CRC Press LLC
9588ch11 frame Page 140 Tuesday, September 11, 2001 10:16 AM
act as a gas bubbler. The greater the liquid rate, the lower the gas velocity at which flooding occurs. Larger, more open packings flood at high velocities than smaller, more dense packings. Liquid holdup is a function of liquid flow rate and column pressure drop. Two types of holdup have been defined. Static holdup is the volume of liquid per volume of packing that remains after gas and liquid flows are stopped and the bed has drained. Static holdup depends on packing surface characteristics. The second type is operating holdup which is the volume of liquid per volume of packing that drains out of the bed after gas and liquid flows have been stopped. Gas flow rate has little effect on holdup below loading. Packed towers may be operated above 90% of the flooding velocity, when pressure controls are provided to maintain a fixed maximum pressure drop not to exceed the desired flooding velocity. Strigle9 suggests the following operational characteristics for countercurrent towers. • Pressure drop between 0.25 in. and 0.60 in. H2O per foot of packing • Air velocity between 5.0 and 8.0 ft/s with modern high capacity plastic packing • Inlet concentrations of contaminant in the gas stream not to exceed 5000 ppm byvolume • Liquid irrigation rates typically between 2 and 8 gpm/ft2 of column crosssectional area
11.6.3 CHOOSING
A
TOWER PACKING
There are two major types of packing, random dumped pieces and structured modular forms. The structured packing is usually crimped or corrugated sheets. The packing provides a large interfacial area for mass transfer. It must permit passage of large volumes of fluid without flooding. It should have enough mechanical strength to carry the load and allow easy handling and installation. It should be able to resist thermal shock and possible extreme temperature changes, and it must be chemically resistant to the fluids being processed. The pressure drop should be the result of skin friction and not form drag. Thus, flow should be through the packing and not around the packing. 11.6.3.1 Dumped Packings Random dumped tower packing comes in many different shapes. Two of the most popular are rings and saddles. Sizes range from ¼ in. to 3½ in. with 1 in. being a very common size. The choice of packing is most usually dependent upon the service in which the tower will be engaged. Packings are ceramic, metal, or plastic, dependent upon the service. Ceramic materials will withstand corrosion and are therefore used where the resultant solutions are aqueous and corrosive. Metals are used where noncorrosive organic liquids are present. Plastic packing may be used in the case of corrosive aqueous solutions and for organic liquids which are not solvents for the plastic of which the packing is made. Metal packing is more expensive, but provides
© 2002 by CRC Press LLC
9588ch11 frame Page 141 Tuesday, September 11, 2001 10:16 AM
lower pressure drop and higher efficiency. When using plastic materials, care must be taken that the temperature is not too high and that oxidizing agents are not present. Ring-type packings are commonly made of metal or plastic except for Raschig rings, which are generally ceramic. Ring-type packings lend themselves to distillation because of their good turndown properties and availability in metals of all types that can be press formed. Usually ring-type packings are used in handling organic solutions when there are no corrosive problems. However, rings do not promote redistribution of liquids, and Raschig rings may even cause maldistribution. Saddles are commonly made from ceramic or plastic and give good corrosion resistance. Saddles are best for redistribution of liquid and, thus, serve as a good packing for absorption towers.
11.6.4 PACKED TOWER INTERNALS In addition to the packing, absorption towers must include internal parts to make a successful piece of operating equipment. These internals begin with a packing support plate at the bottom of the tower. The packing support plate must physically support the weight of the packing. It must incorporate a high percentage of free area to permit relatively unrestricted flow of downcoming liquid. A flat plate has a disadvantage in that both liquids and gases must pass countercurrently through the same holes. Therefore, a substantial hydrostatic head may develop. Furthermore, the bottom layer of packing partially blocks many of the openings, reducing the free space. Both of these conditions lower tower capacity. A gas-injection plate provides separate passage for gas and liquid and prevents buildup of hydrostatic head. Liquid distributors are used at all locations where an external liquid stream is introduced. Absorbers and strippers generally require only one distributor, while continuous distillation towers require at least two, at the feed and reflux inlets. The distributors should be 6 in. to 12 in. above packing to allow for gas disengagement from the bed. The distributor should provide uniform liquid distribution and a large free area for gas flow. Liquid redistributors collect downcoming liquid and distribute it uniformly to the bed below. Initially after entering the tower the liquid tends to flow out to the wall. The redistributor makes that portion of the liquid more available again to the gas flow. It also breaks up the coalescence of the downcoming liquid, and it will eliminate factors which cause a loss of efficiency in the tower and reestablish a uniform pattern of liquid irrigation. A bed depth of up to 20 ft should be sufficient before redistribution as needed. Retaining and hold-down plates are used only with ceramic or carbon tower packing. They prevent the upper portion of the packed bed from becoming fluidized and breaking up during surges in pressure or at high pressure drop. The plates rest directly on packing and restrict movement by virtue of the weight of the plate. Retainers or bed limiters prevent bed expansion or fluidization. When operating at high pressure drops, retainers are fastened to the wall. They are designed to prevent individual packing pieces from passing through the plate openings.
© 2002 by CRC Press LLC
9588ch11 frame Page 142 Tuesday, September 11, 2001 10:16 AM
11.6.5 CHOOSING
A
LIQUID–GAS FLOW RATIO
When designing an absorption tower for the clean-up of an off gas, most usually the following variables will be known: G = actual gas flow rate yA0 = mole fraction of A, gas at inlet coming from process yA1 = mole fraction of A, gas at outlet (specified by control agency regulation if discharged to the atmosphere) xA1 = mole fraction of A, liquid into tower, quite frequently is zero if solvent is used only once Based on Equation 11.24, the material balance case around the entire column can be solved for the exit liquid concentration xA0 . G x A 0 = (y A 0 − y A1 ) + x A1 L
(11.66)
Thus, if L or G/L can be found, the entire material balance will be solved. In absorption, on a plot of yA vs. xA, the equilibrium curve can be concave up or nearly a straight line, or the curve can be “S” shaped, having a concave downward portion. These situations are illustrated in the two curves of Figure 11.11 on which the operating line as specified by the material balance is plotted as well. In the case of Figure 11.11(left panel) with a concave equilibrium line, three possible operating lines are shown. Note, on these plots, L/G is the slope of the operating line. As can be seen, the line furthest to the right with the smallest slope represents the limit to which the slope of the operating line can be drawn. Thus, this slope represents a minimum L/G ratio in which xA0 and yA0 are actually in equilibrium, and the line could not be drawn with a smaller slope because it would go through equilibrium. Since true thermodynamic equilibrium can never be reached practically, this point represents a theoretical minimum L/G which never can be attained in practice.
FIGURE 11.11 Graphical absorption tower relations. © 2002 by CRC Press LLC
9588ch11 frame Page 143 Tuesday, September 11, 2001 10:16 AM
Real L/G ratios are usually set at 1.1 to 1.7 times this minimum rate. Thus, if G is known, L/G is determined and xA0 can be found. In the case of Figure 11.11(right panel), with “S”-shaped equilibrium curve, the minimum value of L/G is reached at some point within the column where the operating and equilibrium lines are tangent and thermodynamic equilibrium would be “exceeded” if the L/G ratio were any smaller.
11.6.6 DETERMINING TOWER DIAMETER — RANDOM DUMPED PACKING Knowing the L/G ratio and the overall material balance, having selected the type of packing and the pressure drop per foot of packing, the tower diameter can now be determined. Current accepted practice is to use a modified Sherwood11 flooding correlation to determine tower diameter. Such a correlation is presented in Figure 11.12 by Strigle.9 This correlation uses a linear scale for the ordinate which is expressed in terms of a capacity factor, CS. Table 11.2 presents the definition of terms used in Figure 11.12. It should be noted that the pressure drop correlation ordinate contains a term defined as the packing factor. The packing factor is a characteristic of a particular packing size and shape. Originally it was defined as a/3 where a is the interfacial area per packed volume and is the void fraction. However, this definition for F did not adequately predict the packing hydraulic performance. Therefore, Table 11.3 from Strigle9 presents packing factors which have been calculated from experimentally determined pressure drop.
FIGURE 11.12 Generalized pressure drop correlation. (Reprinted from Strigle, R. F., Packed Tower Design and Applications, Random and Structured Packings, 2nd ed., Gulf Publishing Co., Houston, 1994.) © 2002 by CRC Press LLC
9588ch11 frame Page 144 Tuesday, September 11, 2001 10:16 AM
TABLE 11.2 Variable Definitions and Units
L L G G G* ρG ρL ν F V
Flow Rates Are Now in lb-mass Not lb-moles per Unit Time = superficial liquid mass velocity in lb/ft2/h = liquid mass flow rate in lb/h = superficial gas mass velocity in lb/ft2/h = gas mass flow rate in lb/hr = superficial gas mass velocity in lb/ft2/s = gas density in lb/ft3 = liquid density in lb/ft3 = kinematic liquid viscosity in cst = packing factor = G*/ρG = superficial velocity in ft/s
CS = V
ρG = capacity factor in ft/s ρ L − ρG
Note on Viscosity Absolute viscosity = µ Kinematic Viscosity = ν = µ/ρ poise = 1 gm/cm-s stoke = 1 cm2/s cp = centipoise cst = centistoke cp = 0.01 poise cst = 0.01 stoke ν=
0.01 gm cm − s = 0.01 cm 2 s = cst gm cm 3
Since L/G is known, we can calculate the value of the abscissa in Figure 11.12, if the gas density ρG and the liquid density ρL are known. Although these densities may vary through the column, the variations will be small, especially in the dilute solution case, and an average of the top and bottom values from the column should be sufficiently accurate. If the entering gas is very dilute, the entering values of density could be used. Note also that Figure 11.12 has been altered to include the flooding line. From the abscissa, the packing factor, and the required pressure drop per foot of packing, the ordinate of the curve can be read and the value of G* in lb/ft2-s calculated. With G converted to lb/s the column cross-sectional area As is then:
( )
As ft 2 =
G(lb s) G * lb s- ft 2
(
)
(11.67)
The column diameter can be found from, D=
© 2002 by CRC Press LLC
4G πG *
(11.68)
9588ch11 frame Page 145 Tuesday, September 11, 2001 10:16 AM
TABLE 11.3 Packing Factors, F, for Random Dumped Packings Normal Packing Size (in.) 1/2 IMTP packing (metal) Hy-Pak® packing (metal) Super Intalox® saddles (ceramic) Super Intalox saddles (plastic) Pall rings (plastic) Pall rings (metal) Intalox saddles (ceramic) Raschig rings (ceramic) Raschig rings (1/32 in. metal) Raschig rings (1/16 in. metal) Berl saddles (ceramic)
5/8
3/4
1
145 255 155 220 170
41 45 60 40 55 56 92 179 115 144 110
51
95 81 200 580 300 410 240
380 170 300
1¼
125 110
1½
2
3 or 3½
24 29
12 16
40 40 52 93
18 26 30 28 26 27 40 65
83 65
57 45
18 17 18 22 37 32
Source: Strigle, R. F., Packed Tower Design and Applications, Random and Structured Packings, 2nd ed., Gulf Publishing Co., Houston, 1994.
FIGURE 11.13 Effect of L/G on packing height.
11.6.7 DETERMINING TOWER DIAMETER — STRUCTURED PACKING Parkinson and Ondrey13 report that structured packing is becoming more frequently used in air separations. They also report that structured packings are being favored because they have a higher capacity than dumped packing and scaleup is more predicable. For Intalox® Structured Packing from Saint Gobain Norpro (formerly Norton Chemical Process Products Corp.), Figure 11.13 is a capacity correlation for © 2002 by CRC Press LLC
9588ch11 frame Page 146 Tuesday, September 11, 2001 10:16 AM
nonfoaming systems. In this case the abscissa of Figure 11.13 is defined as the flow parameter X and is given by Equation 11.69. X=
L ρG G ρL
(11.69)
The efficient capacity CSC in ft/s, corrected for surface tension and viscosity effects, is calculated from the ordinate of Figure 11.13 by Equation 11.70. σ CSC = CO L 20
0.16
µL 0.2
− 0.11
(11.70)
where σL = liquid surface tension in dyne/cm µL = liquid viscosity in cp For this correlation, the limits on surface tension are 5 ≤ σL ≤ 73 dynes/cm and on viscosity, 0.07 ≤ µL ≤ 1.1 cp. Design is carried out routinely up to 90% of efficient capacity. A generalized method of predicting pressure drop of structured packing has been developed TABLE 11.4 by Bravo et al.14 A review of the methods for Packing Factors, F, for prediction of pressure drop in structured packing Intalox Structured Packing is presented by Fair and Bravo.15 Bravo, Rocha, Packing Factor and Fair16 present a new more comprehensive Below Above pressure drop model developed from distillation Packing Size 10 psia 10 psia data. Because the pressure drop curves for random and structured packings are similar, Strigle9 1T 23.5 28 reports that pressure drop for structured packing 2T 15.5 20 can be estimated from the generalized correla3T 12.5 15 4T 11 13.5 tion of Figure 11.12. However, in this case the 5T 10 12.5 packing factor is affected by the operating pressure. Useful packing factors from Strigle are Source: Strigle, R. F., Packed Tower reported in Table 11.4 for five different sizes of Design and Applications, Random Intalox® Structured Packing. The smaller packand Structured Packings, 2nd ed., ing factor should be used for pressures below Gulf Publishing Co., Houston, 1994. 10.0 psia or at liquid rates below 4 gpm/ft2.
11.6.8 CONTROLLING FILM CONCEPT The Whitman Two-Film Theory states that mass transfer can be determined by the gas–film resistance operating in parallel with the liquid film resistance. Equation 11.40 describes this action. The film that offers the predominant mass transfer resistance is called the controlling film. Equation 11.40 can be solved for Ky.
© 2002 by CRC Press LLC
9588ch11 frame Page 147 Tuesday, September 11, 2001 10:16 AM
Ky =
kykx 1 = 1 m k + mk x y + ky kx
(11.71)
Gases with a limited solubility in the liquid phase have a high value of m. Therefore, Equation 11.71 reduces Ky ≈ kx/m to implying that the liquid film resistance is controlling. Gases with a high solubility in the liquid phase have a low value of m. Therefore, Equation 11.71 reduces to Ky ≈ ky , implying that the gas film resistance is controlling.
11.6.9 A CORRELATION FOR THE EFFECT ON THE PACKING HEIGHT
OF
L/G RATIO
Many texts, including Strigle9 present a graphical correlation for determining the number of transfer units based on an essentially straight equilibrium and operating lines. This correlation is based on Equation 11.65. Henry’s Law is a straight equilibrium line, and the correlation presented in this section assumes Henry’s Law for the equilibrium relationship. At the minimum L/G ratio yA0 = mxao . Equation 11.61 can be solved for L/G and rearranged as follows, L = y A 0 − y A1 = 1 − y A1 y A 0 G min xA0 xA0 yA0
(11.72)
and then the equilibrium ratio substituted in the equation to give L = 1− y y m A1 A0 ) G min (
(11.73)
For any yA there is an xA determined by the operating line of Equation 11.60. There is also a yA* in equilibrium with the xA such that yA* /m. Assuming that fresh solvent is being used xA1 = 0.0 and Equation 11.60 for the operating line may be rewritten, yA =
y A* m
L +y A1 G
(11.74)
y A* =
m (y A − y A1 ) (L G)
(11.75)
and then solved for yA* ,
Define Ab =
(L G) m
(11.76)
which is the same as Ab in Equation 11.62. Then, define B as a multiple of (L/G)min to set the actual (L/G). Thus,
© 2002 by CRC Press LLC
9588ch11 frame Page 148 Tuesday, September 11, 2001 10:16 AM
(L G) = B (L G)min
(11.77)
and substituting Equation 11.73 Ab =
B ( L G)min = B (1 − y A1 y A 0 ) m
(11.78)
Substitute Equation 11.76 into Equation 11.75 and the following equation results, 1 y A* = y − y A1 ) Ab ( A
(11.79)
For the dilute case, Equation 11.79 is substituted into Equation 11.59. Equation 11.59 is now integrated with the following equation resulting, 1 N OG = ln (y A 0 y A1 ) (1 − 1 Ab) + 1 Ab 1 − 1 Ab
[
]
(11.80)
NUMBER OF TRANSFER UNITS, NOG
This equation is the same as Equation 11.65. Colburn12 put Equation 11.65 into graphical form which makes it easier to use. See Perry and Green10 for an example of this plot. Recall Ab is defined by Equation 11.78 as a function of B, the multiple of (L/G)min that sets the actual (L/G). If the value of (yA1/yA0) is fixed at 0.90, 0.95, and 0.99, NOG can be plotted vs. B with (yA1/yA0) as a parameter, which is somewhat different from the Colburn plot. Figure 11.14, effect of L/G on packing height, is a
MULTIPLE OF MINIMUM L/G RATIO, B
FIGURE 11.14 Capacity Correlation for Intalox® structured packing. (Courtesy of SaintGobain NorPro Corporation, Akron, Ohio.)
© 2002 by CRC Press LLC
9588ch11 frame Page 149 Tuesday, September 11, 2001 10:16 AM
plot of Equation 11.80. For any given B and percent removal, knowing G and Kyoa, HOG can be calculated, and the height of the column can be calculated from Equation 11.57. Since Equation 11.80 is derived for the dilute solution, examination of Figure 11.14 shows that the number of transfer units, NOG, cannot be greatly reduced by increasing B, the multiple of the minimum L/G ratio, above 1.70.
11.6.10 HENRY’S LAW CONSTANTS
AND
MASS-TRANSFER INFORMATION
Henry’s Law Constants can be found in the Chemical Engineers Handbook.10 A listing of these constants for 362 organic compounds in water is given by Yaws et al.17 It is also possible to calculate Henry’s Constant for solubility data, seen in the example in Table 11.5. The measurement of mass-transfer coefficients has occupied many experimenters of the past 70 years. It is surprising that there is not much data available in the open literature. The problems of making satisfactory and consistent measurements are threefold: 1. Difficulty in determining the interfacial area 2. Difficulty in determining individual coefficients from measurements of overall coefficients 3. Entrance effects The rate of mass transfer depends upon the available contact area between the phases, i.e., on the degree of subdivision of the phases. Tower packing provides the skeleton over which the liquid flows in thin turbulent films. The packing area
TABLE 11.5 Calculation of Henry’s Law Constant from Solubility Data Solubility of ClO2 in Water With a mole fraction in the vapor of yi = 0.03 Pressure = 1.00 atm Solubility = 2.70 g/l of solution mol wgt ClO2 = 67.5 xi = H=
2.7 67.5 = 0.0007216 997.3 18 + 2.7 67.5
0.030 = 41.57 atm mole fraction 0.0007216
Then Henry’s Law Constant is m=
41.57 = 41.57 1.00
Source: Perry, R. H. and Green, D. W., Chemical Engineer’s Handbook, 7th ed., McGraw-Hill Book Co., New York, 1997.
© 2002 by CRC Press LLC
9588ch11 frame Page 150 Tuesday, September 11, 2001 10:16 AM
becomes effective only if it is wetted. Thus, Kya must include a hidden factor which reflects the proportion of the packing area that is effective. This effective area is proportional to the following factors: 1. 2. 3. 4. 5.
Liquid rate Type of packing Method of packing the tower Nature of the liquid distribution Height and diameter of the tower
Data is available in the literature for many systems. A good summary of available data is presented by Perry and Green.10 Data is given in graphical form or analytical correlations as either HTUs (HOG, etc.) or mass-transfer coefficients (Kya, etc.). Table 11.6 presents mass-transfer coefficient data from Strigle.9 Mass-transfer coefficients for structured packing are generally greater than dumped packing, indicating improved mass transfer. Manufacturers of structured packing should be consulted for available mass-transfer data.
TABLE 11.6 Mass-Transfer Coefficient Data KYa = KGaP KGa Values for a Liquid–Film Controlled System Gas Scrubbing Overall KGa Valuea Contaminant Liquid (lb-mol/h-ft2-atm) Carbon dioxide Hydrogen sulfide Sulfer dioxide Hydrogen cyanide Formaldehyde Chlorine Bromine Chlorine dioxide
4% NaOH 4% NaOH Water Water Water Water 5% NaOH Water
1.5 4.4 2.2 4.4 4.4 3.4 3.7 4.4
KGa Values for Gas–Film Controlled Systems Gas Scrubbing Overall KGa Valuea Contaminant Liquid (lb-mol/h-ft2-atm) Hydrogen chloride Hydrogen fluroide Ammonia Chlorine Sulfur dioxide
© 2002 by CRC Press LLC
Water Water Dilute acid 8% NaOH 11% Na2CO3
14 6.0 13 10.8 8.9
9588ch11 frame Page 151 Tuesday, September 11, 2001 10:16 AM
TABLE 11.6 (continued) Mass-Transfer Coefficient Data Relative KGa Values for Tower Packings Size (in.) Type of Packing Plastic Super Intalox® saddles Metal Hy-Pak® packing Metal pall rings Plastic pall rings Ceramic Intalox® saddles Ceramic Raschig® rings Plastic Tellerette® packing Plastic Maspac® packing
1
1½
2
3 or 3½
1.49 1.52 1.62 1.38 1.42 1.21 1.52 —
— 1.28 1.32 1.19 1.19 1.02 — —
1.00 1.12 1.13 1.05 0.99 0.84 1.38 1.00
0.63 0.76 0.65 0.63 0.57 0.51 — 0.62
Effect of Liquid Rate on Scrubber Efficiency Liquid Rate (gpm/ft2) Relative KGa Value 2.00 3.00 4.00 5.00 6.00 8.00 10.0
0.80 0.91 1.00 1.07 1.14 1.25 1.34
a K a values apply to 2 in. plastic Super Intalox® packing at a gas velocity G of 3.5 fps and liquid rate of 4 gpm/ft2.
Source: Strigle, R. F., Packed Tower Design and Applications, Random and Structured Packings, 2nd ed., Gulf Publishing Co., Houston, 1994.
11.6.11 USING HENRY’S LAW
FOR
MULTICOMPONENT SOLUTIONS
In a paper by Carroll,18 using Henry’s Law for multicomponent solutions is considered. In this paper Carroll discusses the following cases: 1. A nonvolatile component dissolved in a solvent including the effect of electrolytes 2. The case of mixed solvents 3. The case of mixed solutes 4. Chemically reacting systems The last two cases are more applicable to the dilute case situation that is discussed in this book. For a binary solvent composed of j and k pure components, Carroll suggests
© 2002 by CRC Press LLC
9588ch11 frame Page 152 Tuesday, September 11, 2001 10:16 AM
ln(H)i,mix = x j ln(H)ij + x k ln(H)ik + a jk x jx k
(11.81)
where Hi,mix is the Henry’s constant for solute i in a mixture of j and k; Hij and Hik are the Henry’s constants for the pure solvents; xj and xk are the mole fractions of the solvents; and ajk is an interaction parameter that must be obtained from experimental data. In the absence of any other information it may be assumed that ajk is independent of i or set equal to zero. For mixed solutes at low pressure, it may be assumed that each gas is independent of the other. A pair of equations can then be written for two solutes i and j. x i H ik = y i P
(11.82)
x jH jk = y jP
(11.83)
Thus the solubility of the individual components is determined by its own partial pressure as if the other component were not present. Carroll also presents several examples of the use of these equations.
11.7 SAMPLE DESIGN CALCULATION This sample is presented to illustrate the use of the design methodology presented in this chapter for an absorption column acting to remove a dilute concentration VOC from an air emission. Therefore, the absorbing solutions will also be dilute. THE PROBLEM An air stream from a electronic circuitry manufacturer contains 50 ppm of a VOC which must be treated. The air stream is flowing at 10,000 acfm at about 1.00 atm pressure and a temperature of 20°C. The emission standard of the local control agency requires 90% removal of the VOC in this case. Therefore, the outlet concentration must be reduced to 5.0 ppm. Water, free of any of the VOC, is to be used as the absorbing liquid. It has been determined for this organic that the Henry’s Law constant is 2.00 and the mass-transfer coefficient is 4.00 lb moles/h-ft3. The molar L/G is to be 1.5 × (L/G)min. To be compatible with the two fluids, 1 in. ceramic Intalox saddles have been chosen for the packing, and the pressure drop has been selected to be 0.50 in of H2O/ft of packing. The packing factor F (Table 11.3) will be 92. At this low VOC concentration it may be assumed that the molecular mass of the gas stream is essentially that of air, i.e., 29.0. The physical properties of the water are • • • • • •
Molecular mass = 18 Temperature = 20°C Pressure = 1.0 atm Density = 62.3 lbm/ft3 Viscosity = 1.0 cp Kinematic viscosity = 1.0 cst
© 2002 by CRC Press LLC
9588ch11 frame Page 153 Tuesday, September 11, 2001 10:16 AM
Equilibrium is described by Henry’s Law with m = 2.00: y i = 2.00 x i
(11.20)
The operating line based on Equations 11.24 and 11.66 becomes y A = (L G) (x A − x A1 ) + y A1 Minimum L/G ratio can be calculated by rearranging Equation 11.66
(L G) =
(y (x
A0 A0
− y A1 ) − x A1 )
(11.66)
y A 0 = 0.000050 y A1 = 0.000005 x A1 = 0.000000 X A 0 = x A* 0 =
(L G)min =
y A 0 0.000050 = = 0.000025 m 2.00
0.000050 − 0.0000005 = 1.80 0.000025
The minimum slope operating line is
y a = 1.80 x A + 0.0000005 Operating ( L G) = 1.5 × ( L G) min = 1.5 × 1.80 = 2.70 Equation 11.66 can be solved for the operating xA0 with xA1 = 0.000000. xA0 =
xA0 =
y A 0 − y A1 L G 0.000050 − 0.000005 = 0.0000167 2.70
The operating line then becomes y a = 2.70 x A + 0.000005 The tower diameter can now be calculated. First the L/G ratio must be converted from a molar ratio to a mass ratio.
© 2002 by CRC Press LLC
9588ch11 frame Page 154 Tuesday, September 11, 2001 10:16 AM
18 lbs H 2 O lb moles H 2 O lb moles H 2 O L = 2.70 × 29 lbs air G lb moles air lb moles air lbs H 2 O L = 1.6759 lbs air G Calculate the superficial velocity from Figure 11.12. The abscissa is L ρG G ρL
0.5
0.0753 = 1.6759 62.3
0.5
= 0.058
Read the ordinate value = 1.33. Cs F 0.5 ν0.05 = 1.33 Cs =
1.33 = 0.1387 92 0.5 × 1.0
Calculate the superficial velocity V.
V=
V=
Cs ρG ρ −ρ L G
0.5
0.1387 0.5 = 3.9860 ft s 0.0753 62.3 − 0.0753
Calculate the superficial gas velocity.
G = VρG × 60 min s = 3.9860 = 18.01
lbs min- ft 2
With Q = 10,000 acfm, calculate the mass flow rate. G = ρG Q G = 10, 000 × 0.0753 = 753 lbs min Calculate the tower cross-sectional area for a circular tower.
© 2002 by CRC Press LLC
9588ch11 frame Page 155 Tuesday, September 11, 2001 10:16 AM
As =
G G
As =
753 lbs min lbs 18.01 min- ft 2
A s = 41.81 ft 2 also, As =
Q V
As =
10, 000 ft 3 min 3.9860 ft s × 60 s min
A s = 41.81 ft 2 Column diameter is given by
D=
4 As π
D=
4 × 41.81 = 7.30 ft π
Calculate the height of a transfer unit (HOG). G = 18.01
lbm × 60 min s h × 1.0 lb - mole 29 lbm min- ft 2
G = 37.25
lb -moles hr-ft 2
The mass transfer coefficient Kya is 4.0 lb-moles/h-ft3.
H OG =
G K ya
lb -moles h-ft 2 = = 9.31 ft lb -moles 4.0 3 h-ft 37.25
H OG
Calculate the number of transfer units (NOG).
© 2002 by CRC Press LLC
9588ch11 frame Page 156 Tuesday, September 11, 2001 10:16 AM
y A 0 = 0.000050, y A1 = 0.000005, x A1 = 0.000000 Because xA1 = 0.000000, Equation 11.65 applies to this case.
1 N OG = ln (y A 0 y A1 ) (1 − 1 Ab) + 1 Ab 1 − 1 Ab
[
]
(11.65)
Calculate the absorption factor Ab.
Ab =
L = 2.70 2.00 = 1.35 mG
1 N OG = ln (0.000050 0.000005) (1 − 1 1.35) + 1 1.35 1 − 1 1.35
[
]
N OG = 4.64 Calculate the height of the tower, z, from Equation 11.57. z = H OG N OG z = 9.31 × 4.64 = 43.21 ft From Figure 11.14 with B = 1.5 and yA1/yA0 = 0.90 or 90% removal, NOG = 4.6. Thus z = 9.31 × 4.6 = 42.84 ft which is within the accuracy of reading the graph. The pressure drop through the column is calculated from the original height of packing, 43.21 ft to be ∆P = 0.50 in. of H 2 O ft of packing × 43.21 ft = 21.61 in. of H 2 O The liquid flow rate QL is L = (L G)
lb H 2 O lbs air ×G lb air min-ft 2
L = 1.6759 × 18.01 = 30.18
lbm min-ft 2
lbm × 41.81 ft 2 min-ft 2 = 151.7 gpm 8.32 lb H 2 O gal
30.18 QL =
The irrigation rate is 151.7/41.81 = 3.62 gpm/ft2 of tower area. Suggested rates are between 2 and 8 gpm/ft2 of tower area. Thus the rate is in the suggested range in this case. © 2002 by CRC Press LLC
9588ch11 frame Page 157 Tuesday, September 11, 2001 10:16 AM
11.7.1 FLOODING The gas rate at flooding can be determined at the same L/G ratio, therefore the abscissa of Figure 11.12, the pressure drop curve, is the same as well. The abscissa is 0.058 and the flooding ordinate is then 2.40. Now calculate the superficial velocity V. Cs F 0.5 ν0.05 = 2.40 Cs =
V=
V=
2.40 = 0.2502 92 × 1.0 0.5
Cs ρG ρ −ρ L G
0.5
0.2502 0.5 = 7.1929 ft s 0 .0753 62.3 − 0.0753
Calculate the gas flow rate. Q = VAs Q = 7.1929 ft s × 41.21 ft 2 × 60 s min = 18, 045 acfm Actual operation is at 10,000 acfm, therefore operation is at 10, 000 × 100% = 55% 18, 045 of flooding.
11.7.2 STRUCTURED PACKING To treat additional sources or to meet higher electronic circuit production demand, consider the possibility of increasing the air flow to 20,000 acfm by switching to structured packing. Choose Intalox Structured Packing 2T.9 The X factor of Equation 11.69 has already been calculated to be 0.058. Since the same column will be used, the cross-sectional area will remain the same. Thus, the superficial velocity, V, and capacity factor, Cs, will double to 7.97 ft/s and 0.2773 ft/s, respectively. Because the operation is at 1.0 atm, the packing factor from Table 11.4 will be 20. Now calculate the ordinate of Figure 11.12 CSF 0.5 ν0.05 = 0.2773 × 20 0.5 × 1.0 = 1.2406 © 2002 by CRC Press LLC
9588ch11 frame Page 158 Tuesday, September 11, 2001 10:16 AM
From the generalized pressure drop correlation of Figure 11.12, the pressure drop is estimated to be 0.45 in of H2O/ft of packing. The tower capacity is now determined from Figure 11.13 and Equation 11.70. The X value of 0.058 is the abscissa of Figure 11.13. The ordinate value is estimated to be Co = 0.44 ft/s. The surface tension of water at 70°F is 70 dynes/ft2, and the viscosity is 0.81 cp. The tower efficient capacity from Equation 11.70 is σ CSC = CO 20 CSC
0.16
70 = 0.44 20
µ 0.20
0.16
−0.11
0.81 0.20
−0.11
(11.70) = 0.46 ft s
The actual capacity factor CS = 0.2773 ft/s is below 90% of the maximum tower efficient capacity, 0.90 × CSC = 0.4140 ft/s. Therefore, the tower, if changed to structured packing, could take even a greater air flow.
REFERENCES 1. Higbie, R., The rate of absorption of pure gas into a still liquid during short periods of exposure. Trans. A.I.Ch.E., L1, 365–389, 1935. 2. Rees, R. L., The removal of oxides of sulfur from flue gases. J. Inst. Fuel, 25, 350–357, 1953. 3. Crocker, B. B., Capture of hazardous emissions, in Proceedings, Control of Specific Toxic Pollutants, Conference, February 1979, Gainesville, FL, Air Pollution Control Assoc., Pittsburgh, PA, 1979, 414–433. 4. Crocker, B. B. and Schnelle, Jr., K. B., Air pollution control for stationary sources, in Encyclopedia of Environmental Analysis and Remediation, Meyers, R. A., Ed., John Wiley & Sons, Inc., New York, 1998, 151–213. 5. Teller, A. J., Chem. Eng. Prog., 63, 75, 1967. 6. Smith, J. M., van Ness, H. C., and Abbott, M. M., Introduction to Chemical Engineering Thermodynamics, 5th ed., McGraw-Hill Companies, Inc., New York, 2000. 7. Danckwerts, P. V., Significance of liquid film coefficients in gas absorption, Ind. Eng. Chem., 41, 1460–1467, 1951. 8. Whitman, W. G., The two film theory of gas absorption, Chem. Metal., 2(E), 146–148, 1923. 9. Strigle, R. F., Packed Tower Design and Applications, Random and Structured Packings, 2nd ed., Gulf Publishing Co., Houston, 1994. 10. Perry, R. H. and Green, D. W., Chemical Engineer’s Handbook, 7th ed., McGrawHill Book Company, New York, 1997, section 14. 11. Sherwood, T. K., Shipley, G. H., and Holloway, F. A. L., Ind. Eng.Chem., 30, 765, 1938. 12. Colburn, A. P., Simplified calculation of diffusional processes, Ind. Eng. Chem. 33, 459–467, 1961. 13. Parkinson, G. and Ondrey, G., Packing towers, Chem. Eng., Newsfront, 39, December 1999. 14. Bravo, J. L., Rocha, J. A., and Fair, J. R., Hydrocarbon Proc., 56(3), 45, 1986. 15. Fair, J. R. and Bravo, J. L., Chem. Eng. Prog., 86(1), 19, 1990. © 2002 by CRC Press LLC
9588ch11 frame Page 159 Tuesday, September 11, 2001 10:16 AM
16. Bravo, J. L., Rocha, J. A., and Fair, J. R., I. Chem. E. Symp. Series, No. 128, A439, 1992. 17. Yaws, C., Yang, H., and Pan X., Henry’s Law Constant for 362 organic compounds in water, Chem. Eng., November 1991. 18. Carroll, J. J., Use Henry’s Law for multicomponent mixtures, Chem. Eng. Prog., 53, August 1992.
© 2002 by CRC Press LLC
9588ch12 frame Page 161 Wednesday, September 5, 2001 9:54 PM
12
Adsorption for HAP and VOC Control
12.1 INTRODUCTION TO ADSORPTION OPERATIONS In adsorption operations, solids, usually in granular form, are brought in contact with gaseous or liquid mixtures. The solids must have the ability to preferentially concentrate or adsorb on their surfaces specific components from the mixture. This phenomenon is possible because the attractive forces that exist between the atoms, molecules, and ions holding the solids together are unsatisfied at the surface and are thus available for holding the components in the mixtures to be adsorbed. Consequently these components can be separated from each other and the carrier fluid. Adsorption is used broadly in the chemical process industries. Early on, one of its most significant applications was the drying of wet air over beds of solid desiccants for pneumatic control instruments. Original process applications range from solvent reclamation in dry cleaning to the recovery of ethyl acetate and toluene from cellophane drying operations. A broad area for adsorption application is in component recovery. Processes of this sort have been patented for fractionated petroleum products by oil and chemical companies. A typical early application was that of the Hypersorption process developed by the Union Oil Company of California in the mid-1940’s in which a moving bed of carbon separated light hydrocarbons.1 Another widespread application of adsorption is the recovery of valuable solvents from air streams. Of most relevance in this book are adsorption processes which are used to eliminate impurities from emissions to the ambient air. Solvent recovery, removal of other organic compounds, and odor removal are all important in producing clean effluents. The best applications of adsorption are in handling large volumes of air flow with dilute pollution levels and removal of the contaminants, especially VOCs, down to trace levels such as 1.0 ppmv. Table 12.1 summarizes some of these operations and the type of adsorbent used.
12.2 ADSORPTION PHENOMENON Adsorption is based on the capability of porous solids with large surfaces such as silicon gel, activated carbon, etc., to selectively retain and release compounds on the surface of the solid. Two general phenomena are recognized in adsorption. Physical adsorption is a low-temperature process similar to condensation. Chemisorption, which occurs at high temperatures, is a process in which forces are very strong in the nature of an actual chemical bond.
© 2002 by CRC Press LLC
9588ch12 frame Page 162 Wednesday, September 5, 2001 9:54 PM
TABLE 12.1 Adsorption Processes and Type of Adsorbent Adsorbent Substance to Be Removed Odors Oil Hydrocarbons Fluorocarbons Chlorinated hydrocarbons Organic sulfur Compounds Solvents Moisture
Activated Carbon x x x x x x x x
Activated Alumna
Silica Gel
Molecular Sieves
x x
x x x x
x
x x
x x
In gas separation, physical adsorption is of primary importance. The adsorbate molecules diffuse from the gas phase across the boundary layer to the surface of the adsorbent where they are held by fairly weak van der Waals forces. Heat is liberated approximately equivalently to the heat required for condensation. At saturation, these two adsorption processes lead to a complete covering of the solid surface with the adsorbate substance. In physical adsorption more than a monomolecular layer can build up. The packing density of molecules at saturation will reach approximately the density of the molecules in liquid form. Another important phenomenon that occurs is capillary condensation. At higher pressures, the gases and vapors begin to condense in the pores of the adsorbates. The adsorption forces reduce the vapor pressure in the capillaries so that it is possible to condense vapors at temperature well above the condensation temperature.
12.3 ADSORPTION PROCESSES The techniques used in adsorption processes include both stagewise and continuouscontacting methods applied to both continuous, and semicontinuous operations. These operations are analogous to absorption when only one component of a gas is strongly absorbed. When more than one component of the gas is strongly adsorbed, the operation is one which is analogous to fractionation, and in particular it becomes much like extraction.
12.3.1 STAGEWISE PROCESS For example, in the stagewise drying of air with silica gel, the silica gel is contacted countercurrently in the upper part of the tower with the air to be dried. The contact takes place on perforated trays in relatively shallow beds, the gel moving from tray to tray through down spouts. In the lower part of the tower, the gel is dried by similar contact with a hot gas, which desorbs and carries off the moisture. The dried gel is © 2002 by CRC Press LLC
9588ch12 frame Page 163 Wednesday, September 5, 2001 9:54 PM
recirculated to the top of the absorber by an air lift. In cases where the adsorbed component is to be recovered, for example, an organic solvent, the regeneration might include steam stripping of the adsorbent with distillation or decantation of the organic solvent from the water. The adsorbent would then be air dried and returned to the tower.
12.3.2 CONTINUOUS CONTACT, STEADY-STATE, MOVING-BED ADSORBERS Countercurrent, continuous-contact, steady-state, moving-bed adsorbers in which uniform solid flow is obtained without channeling or localized flow irregularities have been developed. One such device for the fractionation of light hydrocarbon gases is the Hypersorber built for the Union Oil Co. process previously mentioned.1 This device uses very hard active coconut shell or fruit pit activated carbon. The feed is introduced centrally, and the solids flow downward from the top. In the upper section the more readily adsorbed components are picked up by the descending solid. The top gas product contains the poorly adsorbed constituents. Solids passing the feed point contain all the feed components. In the lower section, a rising stream of gas displaces the most volatile constituents which pass upwards. The adsorbent then leaves the column rich in readily adsorbed components. In the lowest section, the adsorbent is removed from the solid by heating and by steam stripping. Part of the desorbed gas is removed as product while a portion continues up the column as reflux. The solid is recycled to the top by a gas lift.
12.3.3 UNSTEADY-STATE, FIXED-BED ADSORBERS Due to the higher cost of transporting solids in a moving bed as required in steadystate continuous operations, frequently a stationary bed of adsorbent is used. Such a bed adsorbs increasing amounts of solute in an unsteady-state process which continues until the bed is saturated. One of the most important applications of this type of adsorber is the recovery of solvent vapors. Figure 12.1 is a typical arrangement of this type of adsorption vessel. Recovery of 99 to 99.8% of solvent is possible
Screen
Steam and desorbed vapor out
Vapor-gas mixture in Adsorbent bed Drip collector Steam in
Gas out Support screen Condensate out
FIGURE 12.1 Fixed-bed adsorber. © 2002 by CRC Press LLC
9588ch12 frame Page 164 Wednesday, September 5, 2001 9:54 PM
from mixtures containing as little as 0.05% by volume of the solvent. Thus air-vapor mixtures well below the explosive limit may be handled. In most cases the pressure drop through the bed is kept small to reduce power costs. Thus granular rather than powdered adsorbents are used, and bed depths run between 0.30 m (12 in.) and 1.50 m (60 in.). The superficial gas velocity may be in the range of 0.23 to 0.56 m/s (0.75 to 1.83 ft/s). After the adsorber becomes saturated, the gas flow is diverted to a second similar vessel. The adsorbent is regenerated by low pressure steam or hot clean gases. If steam is used, the steam condenses and provides the heat of desorption as well as lowering the pressure of the vapor in contact with the solid. The steam vapor is condensed and the condensed solvent recovered by decantation if it is insoluble in water or by distillation if it is water soluble. The water-saturated adsorbent is readily dried when fresh gas is admitted to the vessel. If moisture is very undesirable in the gas to be treated, the bed can be first air dried then cooled by unheated air prior to reuse for solvent recovery. Our design considerations will be limited to these fixedbed type of adsorbers.
12.3.4 NEWER TECHNOLOGIES 12.3.4.1 Rotary Wheel Adsorber In this newer configuration, the rotary wheel adsorber, a circular medium is coated with carbon or hydrophobic molecular sieves.2 These adsorbents remove the VOC from the air as the device rotates. One part of the wheel is adsorbing while the other part is regenerating. The device is most effective for high flow rates with concentrations below 1000 ppmv and required efficiencies below 97%. 12.3.4.2 Chromatographic Adsorption In chromatographic adsorption, a cloud of solid adsorbent is sprayed into the effluent gas stream.3 The adsorbent and effluent gas travel concurrently through the containing vessel. Adsorption takes place on the adsorbent which is then removed from the gas stream in a conventional bag filter. Adsorption also takes place on the adsorbent particles trapped on the filter bags. 12.3.4.3 Pressure Swing Adsorption In pressure swing adsorption, the adsorbent bed is subjected to short pulses of high pressure gas containing the VOC to be adsorbed.3 The higher pressure results in better adsorption. The pressure is then reduced, and the adsorbed material will vaporize, regenerating adsorbent. By controlling the pressure and cycle time, the pollutant is transferred from the effluent stream to the low-pressure gas regeneration stream.
12.4 NATURE OF ADSORBENTS All solids possess an adsorptive ability. However, only certain solids exhibit sufficient specificity and capacity to make an industrially useful material. Furthermore, unlike © 2002 by CRC Press LLC
9588ch12 frame Page 165 Wednesday, September 5, 2001 9:54 PM
TABLE 12.2 Properties of Representative Adsorbents4
Particle Forma
Mesh Size
Bulk Density (lbm/ft3)
P P P G G G G G S G G G S S G P P S S
4/6 6/8 8/10 4/10 6/16 4/10 3/8 6/16 4/8 4/8 8/14 14/28 (1/4″) (1/8″) 14/28 (1/16″) (1/8″) 4/8 8/12
30 30 30 30 30 28 45 45 50 52 52 54 52 54 30 45 45 45 45
Activated carbon
Silica gel
Activated alumina
Molecular sieves
a
Effective Diameter (ft)
Internal Void Fraction ( o)
External Surface (ft2/ft3)
Reactivation Temperature (°F)
0.0128 0.0092 0.0064 0.0110 0.0062 0.0105 0.0127 0.0062 0.0130 0.0130 0.0058 0.0027 0.0208 0.0104 0.0027 0.0060 0.0104 0.0109 0.0067
0.34 0.34 0.34 0.40 0.40 0.44 0.35 0.35 0.36 0.25 0.25 0.25 0.30 0.30 0.25 0.34 0.34 0.37 0.37
310 446 645 460 720 450 230 720 300 380 480 970 200 400 970 650 400 347 565
200–1000 200–1000 200–1000 200–1000 200–1000 200–1000 250–450 250–450 300–450 350–600 350–600 350–600 350–1000 350–1000 300–600 300–600 300–600 300–600 300–600
P = pellets; G = granules; S = spheroids.
solvents for absorption, the adsorptive characteristics of solids of similar chemical composition depend mostly on their method of manufacture. All carbon is adsorptive, but only “activated” carbon is useful in industrial processes. Carbon can be activated in two ways: one is by use of a gas to create a pore structure by burning of the carbon at 700 to 1000°C followed by treatment with steam at 700 to 900°C; the other is by removing water from the pores of uncarbonized raw materials, such as sawdust, using a solution of zinc chloride, phosphoric acid, or sulfuric acid. The adsorbent must possess appropriate engineering properties, dependent on applications. If used in a fixed bed, it must not offer too great a pressure drop, nor must it be easily carried away in the flowing stream. It must have adequate strength so as not to be crushed in beds nor by being moved about in moving-bed adsorbers. If it is to be frequently transported, it must be free flowing. Table 12.2 is a summary of some of the common properties of adsorbents. A description of these common adsorbents for air-pollution control follows. 1. Activated carbon: This is made by carbonization of coconut shells, fruit pits, coal, and wood. It must be activated, essentially a partial oxidation © 2002 by CRC Press LLC
9588ch12 frame Page 166 Wednesday, September 5, 2001 9:54 PM
process, by treatment with hot air or steam. It is available in granular or pelleted form and is used for recovery of solvent vapors from gas mixtures, in gas masks, and for the fractionation of hydrocarbon gases. It is revivified for reuse by evaporation of the adsorbed gas. 2. Alumina: This is a hard, hydrated aluminum oxide which is activated by heating to drive off moisture. The porous product is available as granules or powders, and is used chiefly as a desiccant for gases and liquids. It may be reactivated for reuse. 3. Silica gel: This is a hard, granular, very porous product made from the gel precipitated by acid treatment of sodium silicate solution. Its moisture content prior to use varies from roughly 4 to 7%, and it is used principally for dehydration of air and other gases, in gas masks, and for fractionation of hydrocarbons. It is revivified for reuse by evaporation of the adsorbed matter. 4. Molecular sieves: These are porous, synthetic zeolite crystals; metal aluminosilicates. The “cages” of the crystal cell can entrap adsorbed matter, and the diameter of the passageways, controlled by the crystal composition, regulates the sizes of the molecules which may enter or be excluded. The sieves can thus separate according to molecular size, but they also separate by adsorption according to molecular polarity and degree of unsaturation. They are used for dehydration of gases and liquids, separation of gas and liquid hydrocarbon mixtures, and in a great variety of processes. They are regenerated by heating or elution.
12.4.1 ADSORPTION DESIGN
WITH
ACTIVATED CARBON
12.4.1.1 Pore Structure The pore structure determines how well an adsorbent will perform in a particular VOC recovery process. Coconut-shell-activated carbon pore diameters average less than about 20 Å. A very high surface volume results and produces a high retentivity for small organic molecules. Thus, coconut shell activated carbon is an ideal adsorbent for VOCs. A smaller portion of the porosity of coal-based activated carbon is in the lower micropore diameter size. Coal-based activated carbons are typically used to remove both low-molecular weight hydrocarbons, such as chlorinated organics, and high-molecular weight materials, like pesticides. 12.4.1.2 Effect of Relative Humidity The relative humidity severely reduces the effectiveness of activated carbon at values greater than 50% relative humidity. At this point, capillary condensation of the water becomes very pronounced, and the pores tend to fill up selectively with water molecules. To reduce relative humidity, the air stream can be cooled first to drop out the moisture, or if the relative humidity is not too high, the air stream can simply be heated 20 or 30°F, or it can be cooled first, then heated.
© 2002 by CRC Press LLC
9588ch12 frame Page 167 Wednesday, September 5, 2001 9:54 PM
12.5 THE THEORIES OF ADSORPTION When a gas is brought into contact with an evacuated solid, a part of the gas is taken up by the solid. The molecules that are taken up and enter the solid are said to be adsorbed, similar to the case of a liquid absorbing molecules. The molecules that remain on the surface of the solid are said to be adsorbed. The two processes can occur simultaneously and are spoken of as “sorption.” If the process occurs at constant volume, the gas pressure drops; if at constant pressure, the volume decreases. To study adsorption, the temperature, pressure, and composition must be such that very little absorption takes place. If a gas remains on a surface of a solid, two things may happen: there may be a weak interaction between solid and gas similar to condensation, or there may be a strong interaction similar to chemical reaction. The first interaction is termed physical adsorption or its synonym, van der Waals adsorption. The name van der Waals implies that the same forces that are active in condensation, i.e., the van der Waals forces, are also active in physical adsorption. The second interaction, in which the forces involved are strong as in chemical bonding, is termed chemical adsorption or chemisorption, or another synonym, activated adsorption. The implication here is that this type of adsorption requires an energy of activation, just as in chemical reactions. The differences between physical adsorption and chemisorption may be briefly summarized in six points. 1. The most fundamental difference between the two types of adsorption is in the forces involved. physical adsorption ≈ van der Waals forces = condensation chemisorption = chemical reactions 2. The differences manifest themselves in the strength of the binding between adsorbate and adsorbent. physical adsorption ≈ van der Waals forces = heat of condensation chemisorption = heat of reaction 3. The difference also manifests itself in the specificity of the process. At sufficiently low temperature, physical adsorption takes place between any surface and any gas, but chemisorption demands a chemical affinity between adsorbate and adsorbent. 4. In physical adsorption, the rate of adsorption is rapid, while in chemisorption the energy of activation must be supplied before the adsorbent–adsorbate complex can form. 5. The adsorption isotherm in chemisorption always indicates unimolecular adsorption, while in van der Waals adsorption, the process may be multimolecular. 6. The adsorption isobar of gases that can be adsorbed by the two processes in the same adsorbent shows both van der Waals and chemisorption regions in which the adsorption decreases with temperature.
© 2002 by CRC Press LLC
9588ch12 frame Page 168 Wednesday, September 5, 2001 9:54 PM
Essentially, physical desorption may be called surface condensation and chemisorption may be called surface reaction. Since the processes are so different, the fundamental laws that deal with the mechanisms are different. On the other hand, laws that deal with equilibrium states only, such as the Clausuis-Clapeyron equation, may be used to calculate the heat released for both physical and chemisorption. Similarly, equations such as the Freundlich Equation which merely describes the shape of the isotherm without implying any mechanisms, may be applied to both types of adsorption. One other factor distinguishes the two types of adsorption and that is the ability to readily reverse the physical adsorption process while removal of chemisorbed gases is more difficult. Simple evacuation combined with heating, or even a simple heating, will remove physically adsorbed gases leaving the chemisorbed material behind. An additional mechanism which adsorbed gases may undergo is capillary condensation. Most adsorbents are full of capillaries, and the gases make their way into these pores adsorbing on the sides of the pore. If a liquid wets the walls of a capillary, the vapor pressure will be lower than the bulk vapor pressure. Thus, it has been assumed that adsorption in capillaries takes place at a pressure considerably lower than the vapor pressure. The capillaries with the smallest diameters fill first at the lowest pressures. As the pressure is increased, larger capillaries fill until at saturation pressure all pores are filled with liquid. It is apparent that capillary condensation plays a role in physical adsorption. Multimolecular adsorption and capillary condensation are necessarily preceded by unimolecular adsorption. One complete theory must be applicable to all of this range, from capillary condensation to multimolecular adsorption. The theory credited to Brunauer, Emmett and Teller, called the BET theory, covers this entire range of adsorption. The theory is based on the assumption that the same forces that produce condensation are chiefly responsible for the binding energy of multimolecular adsorption.
12.6 THE DATA OF ADSORPTION When a gas or vapor is admitted to a thoroughly evacuated adsorbent, its molecules are distributed between the gas phase and the adsorbed phase. The rate of adsorption is so fast in some cases that it is most difficult to measure. In other instances, the rate is more moderate and can be readily measured. After a time the process stops, and a state of stable equilibrium is reached. The amount of gas adsorbed per gram of adsorbent at equilibrium is a function of temperatures and pressure, and the nature of the adsorbent and the adsorbate. a = f ( P, T) a = amount absorbed per gram of adsorbent P = equilibrium pressure T = absolute temperature
© 2002 by CRC Press LLC
(12.1)
9588ch12 frame Page 169 Wednesday, September 5, 2001 9:54 PM
When the temperature is held constant and the pressure varied, the plot produced is known as the adsorption isotherm: a = f (P)
(12.2)
If the adsorption occurs under constant pressure and variable temperature, the plot is called the adsorption isobar: a = f (T)
(12.3)
An adsorption isotere occurs when the variation of the equilibrium pressure with respect to temperature for a definite amount adsorbed is measured. P = f (T)
(12.4)
The amount adsorbed is usually expressed as the volume of gas taken up per gram of adsorbent at 0°C and 760 mm of pressure (STP) or as the weight of gas adsorbed per gram of adsorbent. The amount of adsorption decreases as temperature increases as is shown in Figure 12.2, adsorption isotherms typical of data necessary for design. Here the adsorption is expressed as a capacity by weight percent as a function of the temperature of adsorption with the abscissa being the partial pressure
FIGURE 12.2 Equilibrium adsorption on activated carbon. (Reprinted by permission from Calgon Corporation, Pittsburgh, PA, 15205.)
© 2002 by CRC Press LLC
9588ch12 frame Page 170 Wednesday, September 5, 2001 9:54 PM
of the adsorbate in the gas in psia. For example, if the partial pressure of hexane is 0.0147 psia and the temperature is 80°F, the capacity indicated is about 20%. This means that 100 lbm of carbon will adsorb 0.20 × 100 = 20 lbm of hexane at equilibrium. As a result of the shape of the openings in capillaries and pores of the solid or of other complex phenomenon such as wetting the adsorbate, different equilibria result during desorption than was present in adsorption. The adsorption process exhibits hysteresis, in other words, desorption pressure is always lower than that obtained by adsorption. In some cases it has been found that hysteresis disappears upon a thorough evaluation of the adsorbate. Thus hysteresis must be due to impurities. Some experimenters have accepted the desorption curve as the true equilibria since it represents complete wetting after removal of impurities.
12.7 ADSORPTION ISOTHERMS 12.7.1 FREUNDLICH’S EQUATION The Freundlich Equation is widely used for both liquid and gaseous adsorption. It is a simple equation but valid only for monomolecular layers. The equation may be written as V = P1 n
(12.5)
12.7.2 LANGMUIR’S EQUATION Due to the nature of Langmuir’s derivation of the adsorption isotherm, it is valid only for unimolecular layer adsorption. The isotherm can be written as V=
bPVm 1 + bP
(12.6)
where the terms are defined as follows: V = volume adsorbed Vm = volume adsorbed when surface is covered with a monomolecular layer b = a constant dependent upon molecular parameters and temperature P = the equilibrium pressure of adsorption To determine b and Vm, rearrange Equation 12.6. P P 1 = + V bVm Vm
(12.7)
Measure P and V and plot P/V vs. P. The slope is 1/Vm, and the intercept is 1/(bVm).
© 2002 by CRC Press LLC
9588ch12 frame Page 171 Wednesday, September 5, 2001 9:54 PM
12.7.3 THE BRUNNER, EMMETT, TELLER,
OR
BET, ISOTHERM
The BET isotherm can be used to describe all types of isotherms. Two forms of the isotherm are required, one neglecting capillary condensation and one accounting for capillary condensation. 12.7.3.1 Adsorption Without Capillary Condensation The BET theory assumes that the forces active in capillary condensation are similar to those active in ordinary condensation. It is also assumed that the heat of adsorption on each layer on the layers above the first is equal to the heat of condensation. The theory accounts for multilayered adsorption, and will reduce to the Langmuir monomolecular layer equation in the limit of one layer. Equation 12.8 represents the BET isotherm in this case. V cx 1 + n x n +1 − ( n + 1) x n = Vm 1 − x 1 + (c − 1) x − c x n +1 where n = EL = R = T = CE = c =
(12.8)
number of layers adsorbed heat of condensation gas constant absolute temperature a constant related to condensation and evaporation a second constant related to the energy of condensation on the monomolecular layer and on the subsequent layers
In this case x is related to pressure, temperature, and the energy of condensation. P EL x = e RT CE
(12.9)
For a monomolecular layer n = 1, Equation 12.8 reduces to V cx = Vm 1 + cx
(12.10)
Equation 12.6, the Langmuir isotherm with c = b. When n approaches an infinite number of layers, Equation 12.8 becomes V cx = Vm (1 + x) (1 − x + cx)
© 2002 by CRC Press LLC
(12.11)
9588ch12 frame Page 172 Wednesday, September 5, 2001 9:54 PM
At this condition, the pressure is approaching the saturation pressure or vapor pressure of the gas, and x → 1.0 or x=
(P CE ) e E
(
)
L
Po CE eEL
RT RT
= P Po
(12.12)
where Po = the vapor pressure. Equation 12.11 can be rearranged under these conditions to give x 1 (c − 1) x = + V(1 − x) Vm c Vm c
(12.13)
Recall that x = P/Po, and plot data in the form of x/(V(1 – x)) vs. x. The intercept will then be 1/(Vmc), and the slope will be (c – 1)/(Vmc). The method of fitting data from the plot suggested above is as follows: 1. Use Equation 12.11 up to P/Po = 0.35, where it will begin to deviate from most data. Find Vm and c as suggested above. 2. Use Equation 12.8 with this value of Vm and c, and find n by trial and error. 12.7.3.2 Adsorption with Capillary Condensation Some isotherms suggest that a complete or almost complete filling of the pores and capillaries of the adsorbent occurs at a pressure lower than the vapor pressure of the gas. This lowering of the vapor pressure indicates that as the pressure of the gas increases, an additional force appears to make the energy of binding in some upper layer to be greater than EL, the heat of liquefaction of the gas. This extra energy is due to the last adsorbed layer which is attracted to both sides of the capillary with an additional energy of binding. Assume that 2n – 1 layers build up in the capillary, then
(
)
n −1 n n +1 V 1 + 1 (2 n C E ) − n x − ( n C E − n + 1) x + ( 1 2 n C E ) x (12.14) = Vm 1 + (c − 1) x + ( 1 2 c C E − c) x n − ( 1 2 c C E ) x n +1
When the capillary forces are small, the binding energy is small, and CE → 1.0. Then Equation 12.14 reduces to Equation 12.11.
12.8 POLANYI POTENTIAL THEORY The Polanyi Potential Theory states that the free-energy change in passing from the gaseous to the liquid state is a suitable criterion of the free-energy change for a gas passing to the adsorbed state.5 The adsorption potential for a mole of material is given by
© 2002 by CRC Press LLC
9588ch12 frame Page 173 Wednesday, September 5, 2001 9:54 PM
(
= RT ln f sat fi
)
(12.15)
This potential is a function of the volume of the adsorbed phase. The potential does change appreciably with temperature. For a given adsorbent and for a class of adsorbates, the following two parameters are plotted against each,
[ ( )]
Ordinate = 100 w i ρL,i
[( )
]
(
Abscissa = T ρL,i 1.8 MW B log f sat fi wi T ρL,i (f sat/fi)
= = = =
)
weight of i adsorbed lb/lb temperature °r liquid molar density at the normal boiling point the ratio of the saturation fugacity to the fugacity of component i
At low total pressure, this ratio can be replaced by the ratio of the vapor pressure to the partial pressure. MW = molecular weight of i B = affinity coefficient for use at temperatures above critical Figure 12.3 from Grant and Manes6 is a Polanyi Potential Theory equilibrium plot for adsorption of normal paraffins on BPL activated carbon.
12.9 UNSTEADY-STATE, FIXED-BED ADSORBERS In fixed-bed adsorbers, the fluid is passed continuously over the adsorbent, initially free of adsorbate. At first the adsorbent contacts a strong solution entering the bed. Initially, the adsorbate is removed by the first portion of the bed and nearly all the solute is removed from the solution before it passes over the remaining part of the bed. Figure 12.4 illustrates the conditions for a downflow situation. In part (a) the effluent is nearly solute free. The uppermost part of the bed becomes saturated, and the bulk of the adsorption takes place over a relatively narrow portion of the bed in which concentration changes rapidly. This narrow adsorption zone moves down the bed as a concentration wave, at a rate much slower than the linear velocity of the fluid through the bed. As time progresses, the concentration of the solute in the effluent increases. When the effluent solute concentration reaches a predetermined value, set by emission standards, for example, the break-through point is reached. The solute concentration in the effluent now rises rapidly as the adsorption zone passes out the end of the bed, and the solute concentration in the effluent essentially reaches the initial concentration. The concentration volume of effluent curve in this portion is known as the breakthrough curve.
© 2002 by CRC Press LLC
9588ch12 frame Page 174 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.3 Polanyi Potential Theory equilibrium plot for adsorption of normal paraffins on BPL activated carbon. (Reprinted by permission from Grant, R. J. and Manes, M., Ind. Eng. Chem. Fundam., 3(3), Copyright 1964, American Chemical Society.)
If a vapor is being adsorbed adiabatically from a gas mixture, the evolution of the heat of adsorption causes a temperature wave to flow through the bed similar to the adsorption wave. The rise in temperature of the effluent stream may be used to predict the breakpoint. The shape and time of appearance of the breakthrough curve greatly influences the method of operating a fixed-bed absorber. The actual rate and mechanism of the adsorption process, the nature of the adsorption equilibrium, the fluid velocity, the concentration of the solute in the field, and the bed depth contribute to the shape of the curve produced for any system. The breakpoint is very sharply defined in some cases and in others poorly defined. Generally the breakpoint time decreases with decreased bed height, increased particle size of adsorbent, increased rate of flow of fluid through the bed, and increased solute concentration in the feed. Design consists, in part, by determining the breakpoint curve.
© 2002 by CRC Press LLC
9588ch12 frame Page 175 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.4 Adsorption wave passing down through activated-carbon, bed-breakpoint curve.
© 2002 by CRC Press LLC
9588ch12 frame Page 176 Wednesday, September 5, 2001 9:54 PM
12.10 FIXED-BED ADSORBER DESIGN CONSIDERATIONS There are three main types of fixed-bed adsorbers: canisters, modular, and regenerative. • Canisters: Canisters are easily installed and are returned for refilling with new adsorbent. Usual flow rates are about 100 cfm through 200 lb of adsorbent. Canisters are typically used in control of emissions from pesticide manufacture and to remove methyl and diethyl amine. • Modular: Modular adsorbers remain in place. The adsorbent is replaced when the bed becomes saturated rather than regenerate the adsorbent on site. Service life is as much as 3 months service before replacement is required. Flow rates from 400 to 1100 cfm with beds from 2 ft to 4 ft in depth. With a 5-ft depth, flow rates of up to 10,000 cfm can be sustained. • Regenerative: With high flow rates and VOC concentrations up to 2000 to 10000 ppm, it may be more economical to regenerate the adsorbent in place. Furthermore, exit concentrations in regenerative adsorbers as low as 50 to 100 ppm have been attained. Superficial velocities through the bed from 45 to 100 ft/min are common. As mentioned above, the relative humidity needs to be lowered to prevent interference with the adsorption process by the water molecules. Reduction to below 50% relative humidity is recommended, not only for regenerative beds but also for canisters and modular-type beds as well.
12.10.1 SAFETY CONSIDERATIONS Especially with activated carbon, there is danger of fire due to the heat of adsorption. Ketones are especially bad. Cyclohexanone will oxidize, polymerize, and decompose with the result being high heat generation. Some activated carbons will liberate heat by reaction with oxygen. Thus in many cases adequate air flow is needed to keep the bed cool, or heat exchange coils may need to be installed in the bed.
12.11 PRESSURE DROP THROUGH ADSORBERS The Ergun7 equation was designed to estimate pressure drop through granular solids and is, therefore, a reasonable method to determine pressure drop through adsorbers. In this equation the pressure drop is determined as a function of the bed depth, the internal void volume, the particle diameter, the bed superficial velocity, the gas density, and a Reynolds Number based on the gas properties and the particle diameter.
( )
∆P g c d p 3 150 1 − + 1.75 = x N Re ρ gVg2 1 − where ∆P = pressure drop in lbf/ft2x x = bed depth in ft © 2002 by CRC Press LLC
(12.16)
9588ch12 frame Page 177 Wednesday, September 5, 2001 9:54 PM
gc dp ρG VG
= = = = =
gravitational constant= 32.174 ft-lbm/lbf-s2 particle diameter in ft gas density in lbm/ft3 superficial velocity in ft/s internal void fraction
The Reynolds number is N Re =
d p VGρG µG
where µG = viscosity in lbm/ft-s
12.12 ADSORBER EFFECTIVENESS AND REGENERATION Adsorption systems function as constant outlet concentration devices. Furthermore, the outlet concentration from an adsorber is a function of the amount of adsorbate left on the adsorbent after regeneration. This remaining quantity is called the heel. The heel continues to build up until regeneration will no longer be effective in restoring the adsorptive surface. Until breakthrough, the outlet concentration is controlled by the amount of heel left on the adsorbent. The more vigorous the regeneration, the lower the heel that remains and the lower the outlet concentration will be before rising to breakthrough. Thus, the effectiveness of an adsorber is also controlled by the regeneration process. The common methods of regenerating adsorptive beds are with steam or hot air. If the compound being removed is a valuable condensable organic material, regeneration by steam is usually followed by condensation and separation of the organic layer from the condensed steam layer (water) in a decanter. The organic layer can then be recovered for use again in the original process.
12.12.1 STEAM REGENERATION The quantity, temperature, and pressure of the steam required for regeneration are dependent on the required outlet concentration and how much material is to be removed from the adsorption bed. The steam used must: 1. Raise the bed to the regeneration temperature. 2. Provide the heat of desorption. 3. Act as a carrier gas for the desorbed product. (This is the major portion of the steam flow — 60 to 70%.) For a solvent-recovery process, average steam requirement is in the range of 0.25 to 0.35 lb steam per lb carbon to achieve an adsorber outlet concentration of 70 ppm. For an adsorber operating at an outlet concentration in the 10 to 12 ppm range, steam requirements will be more in the range of 1.0 lb steam/lb carbon. Fair4 © 2002 by CRC Press LLC
9588ch12 frame Page 178 Wednesday, September 5, 2001 9:54 PM
recommends 3.0 to 5.0 lb steam/lb adsorbent. Peak steam demand at 2 to 2.5 times the average will occur in the first 10 to 15 min of the cycle. Figure 12.5 illustrates a fixed-bed VOC steam regeneration system with recovery of the organic material.
12.12.2 HOT AIR
OR
GAS REGENERATION
Heated air or hot off gases from an incinerator are often used for regeneration. Figure 12.6 is a schematic of a hot-gas regenerative system. If the off gases from the regeneration process contain enough organic compounds, they can be used as fuel to the incinerator. Additional fuel may have to be added to the incinerator to raise the temperature of the off gases from the incinerator to that required for regeneration. The incinerator might be a part of another waste gas cleanup process as well. The use of steam or hot gases for regeneration may result in requiring that the adsorption bed be cooled before it is used again for adsorption. In addition, if steam is used for the regeneration, the bed will have to be dried as well as cooled. Therefore, time must be allowed for regeneration, cooling, and drying. Drying and cooling a bed with air may take no more than 15 min. Regeneration could be carried out by atmospheric air. However, it is not likely that the ambient temperature will provide the vigorous regeneration conditions needed. In order to provide more time for regeneration and cooling and to make use of the entire bed of adsorbent in the fixed-bed adsorber, a three-bed system might be used. Figure 12.7 is a schematic of this kind of system. Operation of the system is illustrated by the breakthrough curves of Figure 12.8. Bed 1 is operated discharging to the atmosphere until breakthrough is encountered. Then the effluent from Bed 1 is fed to Bed 2. Bed 1 continues to operate until it reaches a predetermined effluent concentration near saturation. At this time Bed 1 is put into regeneration and cooling. Bed 2 continues to operate to the breakthrough point. Then the effluent from Bed 2 is fed to Bed 3. Bed 2 continues to operate until it reaches the predetermined effluent concentration near saturation. Now it is time for Bed 2 to be regenerated and cooled. Bed 3 continues to operate until it reaches the breakpoint. Bed 1 must be designed to be ready to receive Bed 3 effluent at this time. The process is then repeated until shutdown for replacement of the adsorbent is required.
12.13 BREAKTHROUGH MODEL For a cyclic, fixed-bed process, breakthrough relationships determine the size of the adsorber. Hougen and Marshall8 proposed a series of partial differential equation models to calculate the time–position–temperature–concentration conditions of dilute gases flowing through granular beds. The solutions to the partial differential equations are limited to isothermal conditions with a linear adsorption equilibrium relationship. The solutions are valid for single-component adsorption where mass transfer through the gas film is the controlling step. The fluid velocity is not a function of the direction of flow, and the velocity profile is uniform across the crosssection of the column. Furthermore, there is no longitudinal diffusion or axial mixing in the gas stream where the pressure is assumed constant. Graphical solutions of the © 2002 by CRC Press LLC
9588ch12 frame Page 179 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.5 Fixed-bed activated carbon volatile organic recovery system. © 2002 by CRC Press LLC
9588ch12 frame Page 180 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.6 Fixed-bed activated carbon with hot air regeneration from a thermal oxidizer. © 2002 by CRC Press LLC
9588ch12 frame Page 181 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.7 Three-fixed-bed activated carbon adsorption system.
© 2002 by CRC Press LLC
9588ch12 frame Page 182 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.8 Three-fixed-bed activated carbon adsorption system cycle operation breakthrough curves.
© 2002 by CRC Press LLC
9588ch12 frame Page 183 Wednesday, September 5, 2001 9:54 PM
equations were presented. Later Fair4 further developed this use of the model and graphical methods. More recently Ufrecht, Sommerfeld, and Lewis9 presented solutions of the equations through digital computer techniques using a standard numerical package. A computer model may be easily developed using MATHEMATICA©, a mathematical programming language, which will readily integrate the Bessel function solution to the model equations. The solutions to the partial differential equations presented by Hougen and Marshall in dimensionless form are as follows: y = 1 − e− b τ yo
w = e − ax wo
ax
∫ e I (2
)
−α
0
bτ α dα
(12.17)
)
(12.18)
0
bτ
∫ e I (2 −β
0
ax β dβ
0
where α = ax is a dummy variable proportional to bed depth, and β = bτ is a dummy variable proportional to adsorption time. The model variables and parameters are defined as follows. x τ y w
= bed depth in ft = time of bed operation in h = adsorbate content of fluid stream at τ = adsorbate content of solid at τ
Adsorbent characteristics Dp = effective particle diameter in ft av = external area of solid particles in ft2/ft3 ρB = bulk density in lb/ft3 Gas to be treated G = mass velocity in lb/h-ft2 µG = viscosity in lb/h-ft ρG = density lb/ft3 Model parameters a = 1/Hd in ft–1 b =
Gc ρB H d
in ft–1
Hd = height of a mass transfer unit in ft
© 2002 by CRC Press LLC
9588ch12 frame Page 184 Wednesday, September 5, 2001 9:54 PM
c = yo /wo yo = inlet adsorbate content of fluid stream lb/lb of fluid on an adsorbatefree basis wo = adsorbate content of solid in equilibrium with yo lb/lb of fluid on an adsorbate-free basis Data for various adsorbents as reported by Fair is shown in Table 12.2.
12.13.1 MASS TRANSFER Mass transfer is described by the HTU (height of a transfer unit) method. The height of an overall mass transfer unit HOG is given by H OG = where G Ko av MG
= = = =
G K oa v M G
gas mass velocity based on total cross-section overall mass transfer coefficient based on gas concentration external surface of packing material molecular weight of gas
Correlations are based on the Chilton–Colburn “jd” factor which is a function of the Schmidt Number NSc where K M 2 3 jd = O G N Sc G N Sc =
µG ρG DG
µG = gas viscosity ρG = gas density DG = diffusion coefficient for gas Redefining the height of an overall gas phase transfer unit in adsorption to be Hd Hd =
23 N Sc jd a v
Fair4 reports several correlations for the “jd” mass transfer factor as a function of the Reynolds Number NRe. For large packings:
© 2002 by CRC Press LLC
9588ch12 frame Page 185 Wednesday, September 5, 2001 9:54 PM
jd = 1.30( N Re ) N Re =
−0.45
d pρG VG µG
dp = effective particle diameter VG = superficial gas velocity However, this correlation produces mass-transfer rates which may be two to three times greater than is realistic. Fair4 then presents data in his paper which he states is more appropriate for the kind of adsorbent found in the usual adsorbent bed used for removal of pollutants. The following equations are deduced from the data in Fair’s paper and are a function of the mesh size of the adsorbent. For 4/6 mesh adsorbent, jd = 0.2189( N Re )
−0.2739
For 6/8 mesh adsorbent, jd = 0.1820( N Re )
−0.2762
For 8/10 mesh adsorbent, jd = 0.1424( N Re )
−0.2704
jd = 0.1404( N Re )
−0.3144
For 20/28 mesh adsorbent,
The five equations above for the mass transfer factor “jd” are plotted in Figure 12.9 which illustrates the large difference in the factor for large particles and the adsorbent size normally used in adsorption columns.
12.13.2 BREAKTHROUGH CURVE EXAMPLE Adsorption of n-hexane from natural gas Normal hexane is to be removed from natural gas (molecular weight 17.85) at 815 psia and 94°F by adsorption on silica gel. The entering gas contains 0.853 mol% hexane and has a superficial velocity of 11.4 ft/min. The bed is 43 in. deep and contains 3/8 mesh silica gel. The equilibrium concentration has been measured to be 0.17 lb hexane/lb of gel. Breakthrough data for this system have been reported by McCleod and Campbell.10
© 2002 by CRC Press LLC
9588ch12 frame Page 186 Wednesday, September 5, 2001 9:54 PM
FIGURE 12.9 Mass transfer of gases through granular solids.
Hexane–Natural Gas Measured Breakthrough Data Time in Min
y/yo
bτ
17 21 23.5 26.2 30 33 35.5 38.5 42
0.02 0.04 0.150 0.305 0.510 0.770 0.895 0.965 0.980
15.87 19.60 21.93 24.45 28.00 30.80 33.13 35.63 39.20
The breakthrough model can be tested with this data. Physical properties: Temperature = 94°F Pressure = 1.0 atm Hexane: DG = 0.0057 ft2/h (diffusivity in air) Equilibrium data: measured = 0.17 lbs hexane/lb silica gel estimated = 0.25 lbs hexane/lb silica gel © 2002 by CRC Press LLC
9588ch12 frame Page 187 Wednesday, September 5, 2001 9:54 PM
Natural gas: ρG = 2.73 lbm/ft3 µG = 0.029 lbm/ft-h Silica gel: 3/8 mesh ρB = 52 lb/ft3 dp = 0.010 ft av = 284 ft2/ft3
Summary of Variable and Parameter Values x = bed depth in ft = 3.58 ft τ = time of bed operation in h y = adsorbate content of fluid stream, lb/lb of fluid on an adsorbate-free basis at τ w = adsorbate content of solid, lb/lb of solid on an adsorbate-free basis at τ yo = inlet adsorbate content of fluid stream, lb/lb = 0.415 of fluid on an adsorbate-free basis wo = adsorbate content of solid in equilibrium with yo = 0.17, 0.25 lb/lb of solid on an adsorbate-free basis
Adsorbent Characteristics dp = effective particle diameter in ft = 0/010 ft av = external area of solid particles in ft2/ft3 = 284 ft2/ft3 ρB = bulk density in lb/ft3 = 52 lb/ft3
Gas to Be Treated VG = G = µG = ρG = DG =
superficial velocity in ft/h = 684 ft/h mass velocity in lb/h-ft2 = 1864 lbm/h-ft2 viscosity in lb/h-ft = 0.029 lbm/ft-h density in lb/ft3 = 2.73 lbm/ft3 diffusivity of vapor in gas in ft2/h = 0.0057 ft2/h
Mass-Transfer Correlation for Height of a Transfer Unit d pρG VG , Reynolds Number (unitless) = 644 µG = Chilton–Colburn analogy factor for mass transfer = 0.035 µG = , Schmidt Number (unitless) = 1.86 ρG D G
NRe = jD NSc
Hd =
(N )
23
Sc
jD a v
© 2002 by CRC Press LLC
= 0.1529 ft
9588ch12 frame Page 188 Wednesday, September 5, 2001 9:54 PM
Parameters Hd = height of a mass transfer unit in ft = 0.1529 ft c = yo /wo = 0.24 a = 1/Hd in ft –1 = 6.54 ft –1 b =
Gc in h–1 = 40 h–1 ρB H d
The model was programmed using MATHEMATICA . The resultant curve along with the measured data is plotted in Figure 12.10. Shown are curves for the measured equilibrium adsorption, the estimated equilibrium adsorption, and results for equilibrium adsorption amounts 10 and 20% greater than the measured value.
12.14 REGENERATION MODELING Fair4 suggests that the design problem in hot-gas regeneration is the determination of how long it takes the bed temperature to approach the required regenerating gas temperature. This is essentially a problem in direct-contact heat transfer. The total heat required is the sum of the heat absorbed by the vessel and any appurtances, the heat absorbed by the bed, and the heat of desorption. The heat of desorption is equivalent to the heat of adsorption. The rate of heat addition must be determined. Vessel heat-up time should include estimated heat losses to the surroundings. Bed heat-up time includes the time for desorption. An equation similar to the break-point model could be used to estimate the temperature breakthrough. After desorption is completed, the bed must be cooled back to an acceptable adsorption temperature. If steam is used, time must be allowed to dry the bed as well.
FIGURE 12.10 Adsorption of hexane from natural gas. (• = measured data.) © 2002 by CRC Press LLC
9588ch12 frame Page 189 Wednesday, September 5, 2001 9:54 PM
REFERENCES 1. Berg, A. H., Hypersorption design: modern advancements, Chem. Eng. Prog., 47(11), 585–590, 1951. 2. Humphrey, J. L., Separation processes: playing a critical role, Chem. Eng. Prog., 91(10), 31, 1995. 3. Perry, R. H. and Green, D. W., Chemical Engineer’s Handbook, 7th ed., McGrawHill Book Company, New York, 1997, Section 16. 4. Fair, J. R., Sorption processes or gas separation, Chem. Eng., 90–110, July 14, 1969. 5. Goldman, F. and Polyani, M., Zeitschrift für Physikalische Chemie, 132, 321, 1928. 6. Grant R. J. and Manes M., Correlation of some gas adsorption data extending to low pressures and supercritical temperatures, Ind. Eng. Chem. Fundam., 3(3), 1964. 7. Ergun, S., Chem. Eng. Prog., 48, 87–89, 1952. 8. Hougen, O. A. and Marshall, Jr., W. R., Adsorption from a fluid stream flowing through a stationary granular bed, Chem. Eng. Prog., 43(4), 197, 1947. 9. Ufrecht, R. H., Sommerfeld, J. T., and Lewis, H. C., Design of adsorption equipment in air pollution control, J.A.P.C.A., 30(42), 1348, 1980. 10. McCleod, H. O. and Campbell, J. M., Soc. Petrol. Engrs. J., 166, June 1966.
© 2002 by CRC Press LLC
9588ch13 frame Page 191 Wednesday, September 5, 2001 9:55 PM
13
Thermal Oxidation for VOC Control
Volatile organic compounds (VOCs) generally are fuels that are easily combustible. Through combustion, which is synomonous with thermal oxidation and incinceration, the organic compounds are oxidized to CO2 and water, while trace elements such as sulfur and chlorine are oxidized to species such as SO2 and HCl. Three combustion processes that control vapor emissions by destroying collected vapors to prevent release to the environment are (a) thermal oxidation — flares, (b) thermal oxidation and incineration, and (c) catalytic oxidation. Each of these processes has unique advantages and disadvantages that require consideration for proper application. For example, flares are designed for infrequent, large volumes of concentrated hydrocarbon emissions, while thermal oxidizers are designed for high-efficiency treatment of continuous, mixed-hydrocarbon gas streams, and catalytic oxidizers are designed to minimize fuel costs for continuous, low-concentration emissions of known composition. The design of the basic processes can be modified for specific applications, resulting in the overlap of the distinctions between processes. For example, ground flares are basically thermal oxidizers without heat recovery that frequently are used for intermittent flow of relatively low volumes of concentrated VOC streams.
13.1 COMBUSTION BASICS As every Boy Scout, Girl Scout, and firefighter knows, combustion requires the three legs of the fire triangle illustrated in Figure 13.1. The oxidizer and fuel composition, i.e., air-to-fuel ratio, is critical to combustion. If the fuel concentration in air is below the Lower Flammability Limit (LFL), also known as the Lower Explosive Limit (LEL), the mixture will be too lean to burn. If it is above the Upper Flammability Limit (UFL), it will be too rich to burn. Fuels with a wide range of flammability limits burn more easily than those with a narrow range. With a narrow range, the flame is more unstable since the interior of the flame can easily be starved for air. The heating value of the fuel — the amount of heat released by the combustion process — is determined by the heat of combustion and the concentration of the hydrocarbons in the gas stream. Values for the heat of combustion for common organic compounds are provided in Table 13.1. The heat of combustion is the same as the heat of reaction for the oxidation reaction, and therefore can be calculated from the heats of formation of the reactants and products. It is the net chemical energy that is released by the oxidation reaction when the reactants begin at 25ºC and after the reaction products are cooled to 25ºC. That the reactants are first heated to the ignition temperature and the exhaust gases are hot does not affect the value
© 2002 by CRC Press LLC
9588ch13 frame Page 192 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.1 “Fire triangle.”
for the heat of combustion, because the value includes the energy recovered by cooling the exhaust gases. Indeed, the “higher heating value” includes the energy recovered when water vapor is condensed to liquid at 25ºC, while the lower heating value is based on water remaining in the gaseous state. The flame temperature is determined by a heat balance including the energy produced by combustion, absorbed by the reactant gases, released to the exhaust gases, and lost to the surroundings by radiation. Therefore, factors such as the combustion air temperature, composition of the exhaust gases, and configuration of the combustion chamber affect the peak flame temperature. Despite exposure to flame in the presence of oxygen, not all of a hydrocarbon pollutant will react. The destruction efficiency of VOC pollutants by combustion depends on the three Ts: temperature (typically 1200 to 2000ºF), time (typically 0.2 to 2.0 s at high temperature), and turbulence. The required destruction efficiency often is expressed as 9s. Two 9s is 99% destruction efficiency, and five 9s is 99.999% destruction efficiency. Some VOCs burn easily and do not require extremely high destruction efficiency. Others, especially chlorinated hydrocarbons, do not burn as easily, and the required high destruction efficiency demands a good combination of high temperatures, adequate residence time at high temperature, and turbulence to promote mixing for good combustion of the entire gas stream. Table 13.2 lists the relative destructability for some common VOCs.
13.2 FLARES Flaring is a combustion process in which VOCs are piped to a remote location and burned in either an open or an enclosed flame. Flares can be used to control a wide variety of flammable VOC streams, and can handle large fluctuations in VOC concentration, flow rate, and heating value. The primary advantage of flares is that they have a very high turndown ratio and rapid turndown response. With this feature, they can be used for sudden and unexpected large and concentrated flow of hydrocarbons such as safety-valve discharges as well as venting-process upsets, off-spec product, or waste streams. © 2002 by CRC Press LLC
9588ch13 frame Page 193 Wednesday, September 5, 2001 9:55 PM
TABLE 13.1 Heat of Combustion for Various Compounds Compound Acetaldehyde Acetone Acetylene Ammonia Benzene Butane Carbon monoxide Chlorobenzene Chloroform Cyclohexane Dichloroethane Ethane Ethanol Ethylbenzene Ethylene Ethylene dichloride Ethylene glycol Formaldehyde Heptane Hexane Hydrogen Hydrogen sulfide Methane Methanol Methyl ethyl ketone Methylene chloride Naphthalene Octane Pentane Phenol Propane Propylene Styrene Toluene Trichloroethane Trichloroethylene Vinyl chloride Xylene
Lower Heating Value (BTU/lb) 10,854 12,593 20,776 7992 17,446 19,697 4347 11,772 1836 18,818 4990 20,432 12,022 17,779 20,295 5221 7758 7603 19,443 19,468 51,623 6545 21,520 9168 13,671 2264 16,708 19,227 19,517 13,688 19,944 19,691 17,664 17,681 3682 3235 8136 17,760
Flares cannot be used for dilute VOC streams, less than about 200 BTU/scf, without supplemental fuel because the open flame cannot be sustained. Adding supplemental fuel, such as natural gas or propane, increases operating cost. Flammable gas sensors can be used to regulate supplemental fuel. © 2002 by CRC Press LLC
9588ch13 frame Page 194 Wednesday, September 5, 2001 9:55 PM
TABLE 13.2 Relative Destructability of VOC Pollutants by Combustion VOC Alcohols Aldehydes Aromatics Ketones Acetates Alkanes Chlorinated hydrocarbons
Relative Destructability High
Low
13.2.1 ELEVATED, OPEN FLARE The commonly known flare is the elevated, open type. Elevated, open flares prevent potentially dangerous conditions at ground level by elevating the open flame above working areas to reduce the effects of noise, heat, smoke, and objectionable odors. The elevated flame burns freely in open air. A simplified flow schematic of an elevated, open flare system is shown in Figure 13.2. The typical system consists of
FIGURE 13.2 Simplified flare schematic.
© 2002 by CRC Press LLC
9588ch13 frame Page 195 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.3 Steam assisted smokeless flare tip. (Courtesy of Flare Industries, Inc.)
a header to collect waste gases, some form of assist to promote mixing (frequently steam is used), and an elevated burner tip with a pilot light. A typical burner tip is shown in Figure 13.3. Atmospheric combustion air is added by turbulence at the burner tip. Although flares have a very high turndown velocity, exit velocity extremes determine the size of the flare tip. Maximum velocities of 60 ft/s and 400 ft/s are used for waste streams with heating values of 300 BTU/scf and 1,000 BTU/scf, respectively, to prevent blowout of the flame. A correlation for maximum velocity with heating value is provided by Equation 13.1: log10 (Vmax ) =
(Bv + 1214) 852
where Vmax = maximum velocity, ft/s Bv = net heating value, BTU/scf The design volumetric flow should give 80% of the maximum velocity.
© 2002 by CRC Press LLC
(13.1)
9588ch13 frame Page 196 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.4 Steam-assisted flare: (a) steam off, (b) steam on. (Courtesy of John Zink Company, LLC.)
13.2.2 SMOKELESS FLARE ASSIST Mixing and complete combustion can be improved at the flare tip either by steamassist, air-assist, or pressure-assist mechanisms. As shown in Figure 13.4, the supplemental assist can have a dramatic positive effect on preventing the production of black smoke. A large part of the effect can be attributed to turbulence that draws in combustion air. The water molecules in steam-assisted flare headers may contribute additional benefits. They may separate hydrocarbon molecules which would prevent polymerization and formation of long-chained oxygenated compounds that burn at a reduced rate. And they may react directly with hot carbon particles through the water–gas reaction, forming CO, CO2, and H2 from soot. © 2002 by CRC Press LLC
9588ch13 frame Page 197 Wednesday, September 5, 2001 9:55 PM
Steam typically is added at a rate of 0.01 to 0.6 lb steam per lb of vented gas, depending on the carbon content of the flared gas. Typical refinery flares use about 0.25 lb steam per lb of vent gas, while many general VOC streams use about 0.4 lb steam per lb of vent gas. A useful correlation is 0.7 lb steam per lb of CO2 in the flared gas. Steam assist can produce a loud, high-frequency (above 355 Hz) jet noise in addition to the noise produced by combustion. Noise is reduced by using multiple small jets and by acoustical shrouding. Air assist is accomplished by using a fan to blow air into an annulus around the flare gas stack center channel. The turbulent air is then mixed at the burner tip. Due to the fan power requirement, air assist is not economical for high gas volumes, but is useful where steam is not available. Pressure assist relies on high pressure in the flare header and high pressure drop at the burner tip. This approach cannot be used with variable flow, greatly reducing the number of viable applications.
13.2.3 FLARE HEIGHT The required height of an elevated, open flare is determined primarily by limitation on thermal radiation exposure, although luminosity, noise, dispersion of combustion products, and dispersion of vented gases during flameout also are considerations. The maximum heat intensity for a very limited exposure period of 8 s is 1500 to 2000 BTU/h-ft2. This may give one just enough time to seek shelter or quickly evacuate the area. Most flares are designed for extended exposure at a maximum heat intensity of 500 BTU/h-ft2. The distance from the center of the flame to an exposed person is determined using Equation 13.2: D2 =
τFR 4πK
(13.2)
where D = distance from center of flame, ft τ = fraction of radiated heat that is transmitted (assume 1.0, but could be less for smoky or foggy conditions) F = fraction of heat that is radiated, function of gas composition, burner diameter, and mixing (typical values are 0.1 for H2 in a small burner to 0.3 for C4H10 in a large burner) R = net heat release, BTU/h K = allowable radiation, BTU/h-ft2 The distance from the center of the flame to an exposed person takes into account not only the height of the flare tip, but also the length of the flame and the distortion of the flame in windy conditions. The length of the flame is determined by: log10 L = 0.457 log10 ( R ) − 2.04 where L = flame length, feet © 2002 by CRC Press LLC
(13.3)
9588ch13 frame Page 198 Wednesday, September 5, 2001 9:55 PM
Elevated flare stacks typically are supported in one of three ways: (1) selfsupporting; (2) guy-wires; and (3) derrick. Self-supported stacks tend to be smaller, shorter stacks of about 30 to 100 ft, although stacks of 200 ft or more are possible, depending on soil conditions and the foundation design. Tall stacks can be supported more economically with the aid of guy-wires. Gas piping temperature fluctuations that cause expansion and contraction must be considered. A derrick structure is relatively expensive, but can be used to support the load of a very tall stack.
13.2.4 GROUND FLARE It is possible to enclose a flare tip with a shroud and bring it down to ground level. In an enclosed ground flare, the burners are contained within an insulated shell. The shell reduces noise, luminosity, heat radiation, and provides wind protection. These devices also are known as once-through thermal oxidizers without heat recovery. This type of flare often is used for continuous-flow vent streams but can be used for intermittent or variable flow streams when used with turndown and startup/shutdown controls. A common application is vapor destruction at fuel loading terminals where the vapor flow is intermittent, but predictable. Enclosed ground flares provide more stable combustion conditions (temperature, residence time, and mixing) than open flares because combustion air addition and mixing is better controlled. Maintenance is easier because the flare tip is more accessible. But a disadvantage is that ground flares cannot be used in an electrically classified area because it creates an ignition source at ground level. Temperatures are generally controlled within the range of 1400 to 2000°F using air dampers. They may use single or multiple burner tips within a refractory-lined steel shell. Multiple burners allow the number of burners in use to be staged with the gas flow. Staging can be accomplished by using liquid seal diplegs at different depths or by using pressure switches and control valves. A ground flare enclosure that contains multiple burner tips typically is sized for about 3 to 4 million BTU per hour per square foot of open area within the refractory lining of the enclosure.1 The height of the enclosure depends on the flame length, which is a function of a single burner size, rather than the total heat release. A typical height for 5 MMBTU/h burner tips is about 32 ft.
13.2.5 SAFETY FEATURES Flashback protection must be provided to avoid fire or explosion in the flare header. Protection is provided by keeping oxygen out of the flare header using gas seals, water seals, and/or purge gas, and by using flame arrestors and actuated check valves. Gas seals keep air from mixing with hydrocarbons in the vertical pipe of an elevated flare. Two types of gas seals, a dynamic seal and a density seal, are shown in Figure 13.5. A density or molecular seal forces gas to travel both up and down to get through the seal, like a P-trap water seal, and high-density (high-molecular weight) gas cannot rise through low-density gas in the top of the seal. A low purge flow of natural
© 2002 by CRC Press LLC
9588ch13 frame Page 199 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.5 Types of gas seals. (Courtesy of Flare Industries, Inc.)
gas, less than 1 ft/s, ensures that the gas in the top of the seal is more buoyant than air, and can keep the oxygen concentration in the stack below 1% with winds up to 20 mph. Density seals are recommended in larger flares with tips greater than 36 in. diameter.2 A dynamic gas seal is designed to provide low resistance to upward flow and high resistance to air flowing downward. Natural gas can be used for purge flow at about 0.04 ft/s to keep the oxygen concentration in the flare stack below 6%. Nitrogen also can be used as purge gas, and eliminates the possibility of burn-back into the flare tip at low flow rates. After high-temperature gas is flared, the stack is filled with hot gas that will shrink upon cooling, and that can tend to draw air into the stack. The purge flow compensates for the reduction in volume, and the required purge rate may be governed by the rate of cooling during this period. Flame arrestors and liquid-seal drums also are used to prevent flashback into the flare header. Liquid-seal drums have the advantage of avoiding the potential for being plugged by any liquids that might collect and congeal in the system. And they can be used as a back-pressure device to maintain positive pressure in the flare header. A disadvantage is the possibility of freezing if the liquid seal contains water. Steam coils can be used to heat the seal. Hydrocarbon liquids must be kept out of flare stacks to prevent burning liquid droplets from being emitted from the stack. Knockout drums are used to separate and collect any liquid droplets larger than about 300 to 600 µm before gases are sent to the flare. They may be of either horizontal or vertical design. Generally, knockout drums are designed based on American Petroleum Institute (API) Recommended Practices.3 © 2002 by CRC Press LLC
9588ch13 frame Page 200 Wednesday, September 5, 2001 9:55 PM
13.3 INCINERATION An incinerator, or to be politically correct, a thermal oxidizer, burns VOC-containing gas streams in an enclosed refractory-lined chamber that contains one or more burners. The incoming waste hydrocarbon vapor can be co-fired with natural gas or propane to maintain consistently high oxidation temperatures. A ground flare is one type of incinerator. Discussed below are thermal oxidizers that are designed for high destruction efficiency with heat recovery built-in to reduce fuel consumption cost. Heat recovery may be achieved with recuperative heat exchangers, with a regenerative design that employs ceramic beds, or by heating process fluids or generating steam. An advantage of thermal oxidation in an incinerator is the high destruction efficiency that can be obtained by proper control of the combustion chamber design and operation. If temperatures are maintained above 1800°F, greater than 99% hydrocarbon destruction is routinely achievable.4 This efficiency is due to the increased residence time, consistently high temperature, and thorough mixing (the three Ts: time, temperature, and turbulence) in the combustion chamber. Thermal oxidizers can be costly to install because of required support equipment, including high pressure fuel supplies (for example, natural gas), and substantial process-control and monitoring equipment. In addition, public perception of a new “incinerator” can make it difficult to locate and permit a new unit.
13.3.1 RECUPERATIVE THERMAL OXIDIZER A recuperative thermal oxidizer uses a shell-and-tube type heat exchanger to recover heat from the exhaust gas and preheat the incoming process gas, thereby reducing supplemental fuel consumption. A schematic of a recuperative thermal oxidizer is shown in Figure 13.6. Recuperative heat exchangers with a thermal energy recovery efficiency of up to 80% are in common commercial use.
13.3.2 REGENERATIVE THERMAL OXIDIZER A regenerative thermal oxidizer uses ceramic beds to absorb heat from the exhaust gas and uses the captured heat to preheat the incoming process gas stream. Destruction of VOCs is accomplished in the combustion chamber, which is always fired and kept hot by a separate burner. This system provides very high heat recovery of up to 98%, and can operate with very lean process gas streams because supplemental heat requirements are kept to a minimum with the high heat recovery. The gas steam may contain less than 0.5% VOC, and have a low heat value of less than 10 BTU/scf. A two-chamber regenerative thermal oxidizer in shown schematically in Figure 13.7. The incoming process gas passes through the warm ceramic bed and is preheated to almost the temperature of the combustion chamber. Figure 13.7 shows a typical inlet gas temperature of 100ºF exiting the first chamber at approximately 1430ºF. The combustion chamber provides time, temperature, and turbulence, with the combusted gases exiting at approximately 100 to 170ºF through the second ceramic bed. Heat is recovered in the second ceramic bed. When the process gas exit temperature reaches approximately 170ºF, valves switch the direction of flow © 2002 by CRC Press LLC
9588ch13 frame Page 201 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.6 Recuperative thermal oxidizer flow schematic.
FIGURE 13.7 Two-chamber regenerative flow schematic.
so that the incoming gas passes through the freshly warmed bed. By cycling the valves quickly, as often as every 30 to 120 s, the temperature fluctuation at any point within the bed does not exceed about 70° throughout each cycle. This requires large, © 2002 by CRC Press LLC
9588ch13 frame Page 202 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.8 Two-chamber regenerative oxidizer emissions.
rapid-cycling valves and extensive ductwork. The valves must be designed for very low leakage since any leakage contaminates the treated exhaust gases with untreated process gas. Critical high-efficiency systems use zero-leakage valves with an air purge between double-seal surfaces. If the VOC emissions from a two-chamber bed are measured, the concentration would vary as shown in Figure 13.8. Intermittent spikes in the VOC concentration would occur each time the valves switch the direction of flow, because untreated process gas would be present in the inlet bed when it is suddenly switched to the outlet. This reduces the overall VOC destruction efficiency. To overcome this problem, a third bed is used. This allows a purge step to sweep untreated process gas out of an inlet bed before it is switched to become an outlet bed. A schematic of the three-chamber design is shown in Figure 13.9. This figure shows that the purge gas can be treated process exhaust gas, which will be free of VOC. Large and small three-chamber designs are shown in Figures 13.10 and 13.11. Figure 13.12 shows a seven-chamber regenerative thermal oxidizer. Five- and seven-chamber oxidizers are used not to improve VOC destruction efficiency, but to increase capacity. Three beds are switched at a time with half of the beds serving as inlet and half as outlet beds, while the odd bed is being purged. The multiple beds are designed and sized for ease of transport and construction. The ceramic material is frequently made up of ceramic saddles of the same type that are used as packing material in packed scrubbers. Figure 13.13 shows random packing being loaded into a new bed. Random packing is less expensive and easier to install compared to structured ceramic packing. But structured ceramic packing, as shown in Figure 13.14, can be used and exhibits lower pressure drop and a lower propensity to fouling with particulate that may be in the process gas. Structured packing is made from blocks of ceramic material that contain multiple gas passages. It can provide up to 67% higher bulk density and up to 440% higher surface area
© 2002 by CRC Press LLC
9588ch13 frame Page 203 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.9 Three-chamber regenerative flow schematic.
FIGURE 13.10 Three-chamber regenerative thermal oxidizer. (Courtesy of Smith Environmental Corp.)
than random packing, making structured packing a superior heat storage and heat transfer material. Lower pressure drop results from laminar flow through the structured passages. With a superficial inlet velocity of 5.0 ft/s, structured packing provides a pressure drop of about 1.7 in. H2O per foot, as compared to approximately 5 in. H2O per foot of random packing. And the pressure drop variation with flow is linear with structured packing. The lower pressure drop reduces fan power cost or can be exploited to make a larger ceramic bed for more efficient thermal energy recovery.5
© 2002 by CRC Press LLC
9588ch13 frame Page 204 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.11 Small three-chamber regenerative thermal oxidizer. (Courtesy of Smith Environmental Corp.)
FIGURE 13.12 Seven-chamber regenerative thermal oxidizer. (Courtesy of Smith Environmental Corp.)
13.3.3 RECUPERATIVE
VS.
REGENERATIVE DESIGN SELECTION
Recuperative heat recovery tends to be less efficient, but less expensive to install, than regenerative heat recovery. Therefore, it is most economical to use this type of heat recovery for small systems with more concentrated VOC gas streams that have a high heating value. Once again, the most economical unit is the classic tradeoff of operating vs. capital cost. The cost factors that must be considered include: • Equipment capital cost • Installation cost • Auxiliary fuel costs, based on thermal efficiency © 2002 by CRC Press LLC
9588ch13 frame Page 205 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.13 Loading random media. (Courtesy of Smith Environmental Corp.)
FIGURE 13.14 Installing structured media. (Courtesy of Geoenergy International Corp.)
• Fan power, based on pressure drop and gas flow • Maintenance costs, affected by valve cycling and fouling of the heat exchanger or packing
13.4 CATALYTIC OXIDATION Like flares and incinerators, catalytic oxidation units destroy hydrocarbon vapors via thermal oxidation, but at lower temperatures with the assistance of a catalyst that promotes oxidation. This reduces fuel requirements and operating costs for catalytic oxidation systems. It also reduces NOx emissions from the combustion process, and CO emissions are low, too, because CO oxidation is promoted by the catalyst. © 2002 by CRC Press LLC
9588ch13 frame Page 206 Wednesday, September 5, 2001 9:55 PM
FIGURE 13.15 Typical catalytic oxidation system.
Typical operating temperatures of catalytic incinerators range from 400 to 650°F for heavy hydrocarbons (C4 and above), 700 to 1000°F for light hydrocarbons (C3 and below), and 400 to 900°F for halogenated hydrocarbons. Because of the lower operating temperatures, the system enclosure may not require the rugged refractory lining needed for a high-temperature combustion chamber. Stainless steels are recommended for interior surfaces and parts exposed to preheat and oxidizer temperatures.6 Catalytic oxidation units may incorporate a recuperative heat exchanger for heat recovery to save additional fuel cost. A typical system consists of a hot gas heat exchanger, a thermal preheat zone with a standard burner, and a catalyst bed as shown in Figure 13.15. Catalytic incinerators are most effective at treating low concentration vapor streams, less than one percent by volume, of known composition. Treating higher concentration vapor streams can overheat and deactivate the catalyst. Dilution of the vapor stream may be required to lower the vapor concentration to below the LEL before treatment by catalytic oxidation as well as to provide a heat sink to prevent overheating. Mixed hydrocarbon vapors from miscellaneous sources often contain something that will affect the catalyst, and frequently have highly variable heating values. Noble metals such as platinum and palladium may be used as catalysts for VOC oxidation. They may be applied to a ceramic or metal substrate with an alumina washcoat. Metal oxides, including chromia/alumina, cobalt oxide, and copper oxide/manganese oxide also are used. Each type of catalyst has an optimum temperature range in which it is effective. Generally, precious metal catalysts are optimized for VOC oxidation at higher temperatures than metal oxide catalysts. © 2002 by CRC Press LLC
9588ch13 frame Page 207 Wednesday, September 5, 2001 9:55 PM
Catalysts supported on a fixed substrate are less susceptible to attrition, thermal shock, and catalyst carryover than catalyst in packed or fluidized beds, and the substrate stucture provides relatively low pressure drop, less than 0.5 in. H2O per inch of bed depth. Catalyst pellets in packed beds can have a pressure drop of 8 to 80 in. H2O per inch of bed depth, but allow easy replacement when placed on shallow trays. Fluidized catalyst beds provide uniform heating and high surface area for catalyst activity and avoid the potential for catalyst blinding when particulate is in the process gas. Precious metal catalysts are sensitive to contaminants in the feed streams and can be poisoned easily. Lead, zinc, mercury, arsenic, phosphorous, bismuth, antimony, iron oxide, and tin are potential poisons to catalysts. Halogens, sulfur compounds, and NO2 are potential chemical inhibitors, although some inhibitors can be removed by washing with acid or alkaline solutions. Particulate can collect on fixed bed catalyst and blind or mask the active sites. Sometimes compressed air or steam is used to blow off the catalyst surface. Also, heavy hydrocarbons (even in small amounts) will tend to deposit on fixed catalyst, causing deactivation by masking. Some heavy hydrocarbons and even coke dust can be burned off of the catalyst surface to reactivate it. Eventually, the catalyst will have to be replaced. Typical catalyst life can be expected to be 2 to 5 years. Catalytic oxidation can be used as a “polishing” step, following a recovery unit (e.g., lean oil absorption or other VOC control system) which removes the majority of the hydrocarbon. Given a constant flow of low-concentration vapor feed material, catalytic incinerators can provide economical high-efficiency VOC destruction.
REFERENCES 1. Leite, O. C., Safety, noise, and emissions elements round out flare guidelines, Oil Gas J., 24, 68, 1992. 2. Leite, O. C., Design alternatives, components key to optimum flares, Oil Gas J., 23, 70, 1992. 3. American Petroleum Institute, Guide for Pressure-Relieving and Depressuring Systems, API Recommended Practice 521, 4th ed., Washington, D.C., 1997. 4. U.S. Environmental Protection Agency, Handbook — Control Technologies for Hazardous Air Pollutants, EPA-625-6-91-014, Research Triangle Park, NC, 1991. 5. Pitts, D. M., Regenerative thermal oxidizers: structured packing improves performance, Chem. Eng., 106(1), 113, 1999. 6. Clean Air Compliance Handbook, Megtec Systems, DePere, WI, 1998.
© 2002 by CRC Press LLC
9588ch14 frame Page 209 Wednesday, September 5, 2001 9:57 PM
14
Control of VOC and HAP by Condensation
14.1 INTRODUCTION Condensation of a vapor from an air stream can take place as a film of the condensed material on the wall of the condenser tube or as a series of drops that form at various points on the surface. Film-type condensation is the more common mechanism encountered in a condenser. The film uniformly coats the surface, and the thickness of the film increases with the extent of the surface. In dropwise condensation, the surface is not uniformly covered. The individual drops form and grow on the surface and tend to coalesce with neighboring drops. Adhesion of the drops is then overcome by gravitational forces, and the coalesced drops run off the surface. Impurities in the vapor stream promote dropwise condensation which results in higher heat transfer coefficients. Unfortunately there is not much information available on dropwise condensation. Therefore, design methods are limited to the film-type case. Condensers are best applied for removal of VOC and HAP from emission streams when the concentration is greater than 5000 ppmv. Removal efficiencies range from 50 to 90%. The upper end of efficiencies are practically achievable for concentrations in the range of 10,000 ppmv or greater. With high concentrations of pollutant, condensers are frequently employed as preliminary air-pollution-control devices prior to other devices such as incinerators, absorbers, or adsorbers. Flows up to 2000 scfm can be handled in condensers. In condensation, one or more volatile components of a vapor mixture are separated from the remaining vapors through saturation followed by a phase change. The phase change from gas to liquid can be achieved by increasing the system pressure at a given temperature, or by lowering the temperature at a constant pressure. The lower the normal boiling point, the more volatile the compound, the more difficult to condense, and the lower the temperature required for condensation. Refrigeration must often be employed to obtain the low temperatures required for acceptable removal efficiencies.
14.2 VOC CONDENSERS The two most common types of condensers used are surface and contact condensers. In surface condensers, the coolant does not contact the gas stream. Most surface condensers are the shell and tube type as shown in Figure 14.1. Shell and tube condensers circulate the coolant through tubes. The VOCs condense on the outside of the tubes within the shell. Plate and frame type heat exchangers are also used as condensers in refrigerated systems. In these condensers, the coolant and the vapor
© 2002 by CRC Press LLC
9588ch14 frame Page 210 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.1 Shell and tube type surface condenser schematic.
flow separately over thin plates. In either design, the condensed vapor forms a film on the cooled surface and drains away to a collection tank for storage, reuse, or disposal. In contrast to surface condensers where the coolant does not contact either the vapors or the condensate, contact condensers cool the volatile vapor stream by spraying either a liquid at ambient temperature or a chilled liquid directly into the gas stream. Spent coolant containing the VOCs from contact condensers usually cannot be reused directly and can be a waste-disposal problem. Furthermore, spent coolant is then contaminated with the VOC, and therefore, must undergo further treatment before disposal.
14.2.1 CONTACT CONDENSERS In contact condensers, a coolant, frequently water, is sprayed into the gas stream. Condensation proceeds as a heat-exchange process where the air stream containing the condensable materials is first cooled to its condensation temperature, then loses its heat of condensation. The coolant first gives up its sensible heat, then its heat of vaporization. The balancing of the heat exchange between the two streams will determine the amount of coolant needed. Design of contact condensers is based on the gas–liquid stage concept. However, spray systems operate with a high degree of back mixing of the phases. This practically limits spray chamber performance to a single equilibrium stage. For a direct contact device, this means that the temperatures of the exiting gas and liquid would be the same. Backmixing results because the chief resistance to flow is only the liquid drops. There is no degree of stabilization of the flow such as would happen in a packed tower. Anything less than perfect liquid distribution will induce large eddies and bypass streams. Thus, special care must be taken to obtain a uniform spray pattern. © 2002 by CRC Press LLC
9588ch14 frame Page 211 Wednesday, September 5, 2001 9:57 PM
14.2.2 SURFACE CONDENSERS In the shell and tube heat exchangers, the coolant typically flows through the tubes and the vapors condenser on the outside of the tubes. In these units the pollutant gas stream must be cooled to the saturation temperature on the material being removed. The problem of design is complicated by the fact that most pollutant gas streams are essentially air with a small amount of VOC or HAP included. Therefore, condensation takes place from a gas in which the major component is noncondensable. In the case of a simple air stream where the other component is condensable, condensation occurs at the dew point when the partial pressure of the condensable equals its vapor pressure at the temperature of the system. Since the coolant from surface condensers does not contact the vapor stream, it is not contaminated and can be recycled in a closed loop. Surface condensers also allow for direct recovery of VOCs from the volatile gas stream. This chapter addresses the design of surface condenser systems only. Figure 14.2 shows some typical vapor pressure curves. The more volatile the component, i.e., the lower the normal boiling point, the larger the amount that will remain uncondensed at a given temperature, hence the lower the temperature that is required to reach saturation. Condensation for this type of system typically occurs nonisothermally. The assumption of constant temperature conditions in the design of surface condensers does not introduce large errors into the calculations.
FIGURE 14.2 Typical vapor pressure curves. © 2002 by CRC Press LLC
9588ch14 frame Page 212 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.3 Shell and tube type surface condenser schematic, example calculation.
14.2.2.1 An Example — Condensation Temperature Consider an air stream flowing at 771 scfm containing 13.00 mol% benzene in which 90% removal of the benzene is required. The air flow entering the condenser is at 1.000 atm. What temperature is necessary to achieve this percent removal? The condenser is depicted in Figure 14.3 which is Figure 14.1 labeled with the conditions of operation specific to this example. The partial pressure of the benzene at the outlet of the condenser can be calculated as follows: Basis: 1.000 moles of air stream including the benzene. Assumption: Condenser operates at 1.000 atmosphere or 760 mm of Hg Moles of benzene entering = 0.1300 Moles of benzene leaving = (1 – .90) × 0.1300 = 0.0130 Moles of air + benzene leaving = 1.000 – (0.1300 – 0.0130) = 0.8830 Partial pressure of benzene leaving = (0.0130/0.8830) × 760 = 11.19 mm of Hg Refer to Figure 14.2, the vapor pressure curve. For benzene the value of the abscissa
[t
1 0.00214 = R° + . 459 67 CON
]
Solving for tCON = 6.80°F Therefore the condenser temperature must be below 6.80°F.
© 2002 by CRC Press LLC
9588ch14 frame Page 213 Wednesday, September 5, 2001 9:57 PM
TABLE 14.1 Coolant Selection Required Condensation Temperature (°F) 80 45 –30 –90
to to to to
100 60 45 –30
Coolant Water Chilled water Brine solutions Refrigerants
14.3 COOLANT AND HEAT EXCHANGER TYPE The next step is to select the coolant based on the condensation temperature required. Table 14.1 summarizes some possible coolants. In the case of water, chilled water, and brine solutions, all remain in the liquid phase as they condense the VOC. Refrigerants usually condense the VOC by absorbing the heat as they change phase from liquid to vapor. The usual refrigeration cycle is used for these refrigerants. The vapor is compressed and condensed at a higher pressure and a higher temperature by a fluid at a temperature lower than the condensation temperature. Frequently water can be used to condense the high pressure refrigerant. Most thermodynamics textbooks contain a description of a refrigeration cycle. The problem now is to determine the size and design of the particular type of heat exchanger that is required to carry out the heat transfer needed. Figure 14.1 illustrates a horizontal shell and tube heat exchanger with the coolant inside the tubes and the condensing vapor outside the tubes. Vertical shell and tube heat exchanger arrangements are shown in Figure 14.4. Advantages and disadvantages of each type are listed in Table 14.2. The design of this type of equipment requires the knowledge of suitable heat transfer coefficients. These coefficients are highly dependent on the condensing material, the coolant used, and the particular arrangement of the heat exchanger. They range from 10 to 300 BTU/(h-ft2-°F). Finally the design procedure would include determining the amount of coolant needed.
14.3.1 AN EXAMPLE — HEAT EXCHANGER AREA AND COOLANT FLOW RATE For the heat exchanger discussed previously where the flow is 771.0 scfm, the number of moles would be 2.0 moles/min or 120 moles/h. Data: Heat of condensation of benzene = 13, 230 BTU lb - mole at 1.0 atm, 176°F Specific heats; at 77°F = 25°C Air = C PA = 6.96 BTU lb - mole -°F Benzene = C PA = 19.65 BTU lb - mole -°F Heat transfer medium CPM = 0.65 BTU lb -°F © 2002 by CRC Press LLC
9588ch14 frame Page 214 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.4 Vertical shell and tube heat exchangers arrangements: (a) condensation inside tubes, downflow vapor; (b) condensation inside tubes, upflow vapor; (c) condensation outside tubes, downflow vapor. © 2002 by CRC Press LLC
9588ch14 frame Page 215 Wednesday, September 5, 2001 9:57 PM
TABLE 14.2 Advantages and Disadvantages of Shell and Tube Heat Exchanger Types Used in Condensation Shell and Tube Condenser Types Horizontal Exchanger Condensate outside tubes Condensate inside tubes Vertical Exchanger Condensate inside tubes, vertical downflow Low pressure may require large tubes Condensate inside tubes, vertical upflow
Condensate outside tubes, vertical downflow
Advantages
Disadvantages
May be operated partially flooded Liquid builds up causing slugging
Free draining
Positive venting of noncondensables
Wet tubes retain lightsoluble components
Used for refluxing Usually partially condensing Liquid and vapor remain in intimate contact High coolant side heat transfer coefficient Ease of cleaning
Requires careful distribution of coolant
On the basis of 1 h of operation, Benzene in = 0.13 × 120 = 15.60 moles Air in and out = 0.87 × 120 = 104.40 moles Benzene condensed = 0.90 × 15.6 = 14.04 moles Benzene out = 15.60 − 14.04 = 1.56 moles Air + Benzene out = 104.4 + 1.56 = 105.96 moles Refer to Figure 14.3 for temperatures. Condenser heat load, assuming no heat loss from the heat exchanger to the atmosphere, WS = 0.0, therefore ∆H = Q ∆H = ∆H uncon voc + ∆H air + ∆H cond voc ∆H uncon voc = 1.56 × 19.65 × (80 − 6.8) = 2244 BTU h ∆H air = 104.4 × 6.96 × (80 − 6.8) = 53, 189 BTU h
© 2002 by CRC Press LLC
9588ch14 frame Page 216 Wednesday, September 5, 2001 9:57 PM
To estimate the heat of condensation at T2 = (6.8 + 460) = 466.8°R, use the Watson Equation.1 ∆H voc at T2
1 − T2 TC = ∆H voc at T1 1 − T1 TC
0.38
where TC = 1012°R, the critical temperature of benzene, T1 = (176 + 460) = 636°R, and ∆Hvoc at T2 = 13,236 BTU/lb-mole. ∆H voc at T2
1 − 466.8 1012 = 13.236 1 − 636 1012
0.38
= 15243 BTU lb- mole
∆H cond voc = ∆H voc to cond temp + ∆H cond ∆H cond voc = 14.04 × 19.65 × (80 − 6.8) + 14.04 × 15, 243 ∆H cond voc = 234, 207 BTU h ∆H = 2244 + 53,180 + 234, 207 = 289, 640 BTU h Calculate the heat transfer area, Q = U A ∆Tlog mean U = heat transfer coefficient U = 40 BTU/h-ft2-°F ∆Tlog mean = log mean temperature difference For a derivation and discussion of the log mean temperature difference see Perry and Green2 or a text on heat transfer. ∆Tlog mean =
A=
(80 − 16.8) − (6.8 − (−8.2)) 80 − 16.8 ln (6.8 − ( −8.2))
= 33.51°F
289, 640 = 216 ft 2 0.65(6.8 − ( −8.2))
Calculate the coolant flow. Q = Wcool C PM (Tin − Tout ) Wcool =
© 2002 by CRC Press LLC
289, 640 = 29.707 lbs h 0.65 (6.8 − ( −8.2))
9588ch14 frame Page 217 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.5 Equilibrium dew point–bubble point curve for a binary mixture.
14.4 MIXTURES OF ORGANIC VAPORS The condensation of mixtures of organic vapors occurs over a range of temperatures, thereby complicating the design of heat exchangers for condensing these mixtures. The process for a binary mixture is illustrated in Figure 14.5 where it is presumed the pressure remains constant. A vapor at point A is cooled until it reaches its dewpoint at point B. Further reduction of temperature will cause the mixture to form two phases. At the temperature at point C, the vapor composition is given by point D and the liquid composition by point E. A constant temperature flash calculation could determine not only the compositions at this temperature but also the quantity of vapor and liquid. Continued coolant to the bubble point temperature F will produce 100% liquid with the same composition as the initial vapor. Therefore, as an organic mixture cools from its dew point to its bubble point, the condensing liquid is changing composition. This results in the heat of condensation varying throughout the cooling process. This variation in the heat of condensation should be accounted for in the determination of the area for heat exchange and will result in a greater area than would be calculated from the log mean temperature difference method. In some cases it can make a major difference in the area and, if not accounted for, can result in poor performance of the heat exchanger. For a more detailed description of the dew point, bubble point, and flash calculation methodology, refer to a thermodynamics textbook like Smith et al.1 The original model for sizing a condenser for mixtures of vapors was presented by Colburn and Hougen.3 This method was elaborated upon by Silver4 and Bell and Ghaly.5 © 2002 by CRC Press LLC
9588ch14 frame Page 218 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.6 Vertical upflow total condenser, example calculation.
14.4.1 AN EXAMPLE — CONDENSATION
OF A
BINARY MIXTURE
As an example to illustrate the methodology, consider the condensation of an isopropyl alcohol (IPA) — water mixture in a vertical, countercurrent, upflow condenser at 1 atm. The heat exchanger is to be sized to totally condense the mixture. The total flowrate is 608 lb/h at 214.4°F (101.33°C) and atmospheric pressure at a mole fraction of IPA = 0.128. Cooling water is available at 80°F with a 10°F temperature rise allowed. In the vertical, countercurrent, upflow heat exchanger the vapor is condensing inside the tubes. Figure 14.7 is the bubble point–dew point curve for the IPA–water system. It shows this system to be an azeotrope. The mixture composition we are considering is to the left or the lower IPA composition side. From Figure 14.6 for the IPA mole fraction of 0.128, the dew point is 95.8°C (204.4°F), and the bubble point is 82.6°C (180.7°F). The overall heat transfer coefficient Uo = 100 BTU/h-ft2-°F, and the gas film heat transfer coefficient hg = 7 BTU/h-ft2-°F. First calculate the heat exchange area from the log-mean temperature difference (LMTD) method with the overall heat transfer coefficient. The total heat transferred can be approximated from the latent heats of vaporization and the molar composition. On a mole basis, both latent heats of vaporization for IPA and water are about equal © 2002 by CRC Press LLC
9588ch14 frame Page 219 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.7 Bubble point–dew point curve for the isopropyl alcohol (IPA)–water system at 1 atm.
to 17,400 BTU/lb-mol. The 608 lb/h flowrate is 25.9758 lb-moles/h. Therefore, the heat transferred is Q T = 17, 400 × 25.9758 = 451, 979 BTU h Figure 14.6 is a schematic of the vertical heat exchanger. From Figure 14.6, 124.4 − 100.7 = 112.13 ln(124.4 100.7)
LMTD = Area =
451, 979 100 × 112.13
The more correct method is from Silver,4 and Bell and Ghaly.5 Based on these references, the following model is derived in Appendix A of this chapter.
Area =
∫
QT
0
zU 1 + O hg dQ T U O (TG − TL )
(14.1)
The temperature difference at a mole fraction of IPA = 0.128 between the entering temperature of 214.4°F (101.33°C) and the final temperature of 180.7°F (82.6°C) at the top of the condenser, is divided into seven segments as shown in © 2002 by CRC Press LLC
9588ch14 frame Page 220 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.8 Temperature profiles through heat exchanger. TG is the gas and TL is the liquid coolant.
Figure 14.7. To evaluate the area, the argument of the integral is calculated over each segment and plotted as a function of the heat transferred, QT. Figure 14.8 shows gas, TG, and liquid coolant, TL, temperature profiles as a function of the heat transferred QT as determined by the algorithm shown in Appendix B of this chapter. These temperature profiles seem to suggest that the LMTD should suffice because they look almost linear. However, examination of the temperature difference as a function of QT on Figure 14.9 shows a large variance from a linear curve. Therefore, the LMTD approach would not give reasonable results. Further calculations are
FIGURE 14.9 Gas–liquid temperature difference through the heat exchanger. © 2002 by CRC Press LLC
9588ch14 frame Page 221 Wednesday, September 5, 2001 9:57 PM
VALUE OF INTEGRAND
0.0020 0.0019 0.0018 0.0017 0.0016 0.0015 0.0014 0.0013 0
100000
200000
300000
400000
HEAT TRANSFERRED IN BTU/HR
FIGURE 14.10 Area integral to evaluate Equation 14.1.
made according to the algorithm in Appendix B of this chapter. Figure 14.10 presents the numerical results of the calculation produced by the algorithm for the heat exchanger of this example. Here the heat transferred, QT, is plotted vs. the integrand of the area equation. A simple “counting of squares” produces an Area = 178 ft2, considerably different from the LMTD result of 40.31 ft2.
14.5 AIR AS A NONCONDENSABLE A significant problem with polluted air streams is the large amount of noncondensable included in the air. In the case where water is in the stream, the problem is even more complex. The total pressure is now the sum of the partial pressures of the air, the miscible organics, and the water. The equilibrium of the miscibles is unaffected by the presence of the other components except that the equilibrium exists only at the sum of the partial pressures and not the operating pressure of the condenser. Since the water–air and miscibles–air mixtures attain their separate equilibrium relationships, the system may have two dew points, one for water and one for the miscible organics. For multicomponent mixtures, the calculation could become quite complex.
REFERENCES 1. Smith, J., vanVess, H. C., and Abbott, M. M., Introduction to Chemical Engineering Thermodynamics, 6th ed., McGraw-Hill Inc., New York, 2000. 2. Perry, R. H. and Green, D. A., Perry’s Chemical Engineers’ Handbook, 7th ed., McGraw-Hill, New York, 1997. 3. Colburn, A. P. and Hougan, O. A., I&E Chem., 26, 1178–1182, 1934. 4. Silver, L., Gas cooling with aqueous condensation, Trans. Inst. Chem. Eng., 25, 30–42, 1947. 5. Bell, K. G. and Ghaly, M. A., An approximate generalized design method for multicomponent partial condensers, Chem. Eng. Prog. Symp. Ser., 131, 72–79, 1973. © 2002 by CRC Press LLC
9588ch14 frame Page 222 Wednesday, September 5, 2001 9:57 PM
FIGURE 14.11 Heat transfer through a condensing film.
APPENDIX A: DERIVATION OF THE AREA MODEL FOR A MIXTURE CONDENSING FROM A GAS Refer to Figure 14.11 for a schematic of heat transfer through a condensing film. dQSV dQT TG TL Ti hg Uo
= sensible heat of vapor transferred through the gas film = latent heat and sensible heats of both vapor and liquid = gas temperature in main gas stream (condensing vapor) = liquid temperature in main liquid stream (coolant) = temperature at interface between gas film and condensing film = heat transfer coefficient of gas film = overall heat transfer coefficient through the condensing film, the tube wall, and the coolant film.
This simplified model uses the two heat transfer coefficients defined above. A more complex model would take into account the conduction through the tube wall and the coolant film with separate heat transfer coefficients. Define the heat transfer in terms of the two heat transfer coefficients.
© 2002 by CRC Press LLC
9588ch14 frame Page 223 Wednesday, September 5, 2001 9:57 PM
dQSV = h g (TG − Ti ) dA dQ T = U O (Ti − TL ) dA where A is the heat transfer area. Solve the above two equations for Ti dA. Ti dA = −
dQSV dQ T + TG dA = + TL dA hg UO
Define z, z≡
dQ SV dQ T
Note that z = 0.0 for a pure component condensing isothermally. Then dQ T zU O + dQ T = (TG − TL ) dA UO hgUO Solve for dA, zU O 1 + h g dA = dQ U O (TG − TL ) T Then integrate for the final model,
Area =
∫
QT
0
zU 1 + O hg dQ T U O (TG − TL )
(14.1)
APPENDIX B: ALGORITHM FOR THE AREA MODEL FOR A MIXTURE CONDENSING FROM A GAS • This algorithm applies specifically to binary mixtures without air but could be extended to multicomponent mixtures. Consult Bell and Ghaly5 for extensions to include noncondensables like air. • Data required: 1. Binary vapor liquid equilibria 2. Latent heat of the components of the mixture 3. Vapor and liquid specific heat
© 2002 by CRC Press LLC
9588ch14 frame Page 224 Wednesday, September 5, 2001 9:57 PM
4. Coolant specific heat 5. Heat transfer coefficients UO and hg 6. Amount of vapor to be condensed (molar flow rate required for molar latent heats and specific heats) • Assumptions: 1. Pressure near atmospheric 2. Molal average latent heats and specific heats are good approximations 3. Approximate z = dQSV/dQT by ∆QSV/∆QT .
CALCULATION PROCEDURE: For Section Zero 1. At the initial concentration, cool superheated vapor to the bubble point (removal of sensible heat). 2. Calculate the sensible heat removed. 3. Since this is simply cooling a vapor with no condensation, assume that z = 1.0. 4. Divide the temperature between the bubble point and dewpoint into five or more equal segments. For Section One: First Temperature Segment 1. Cool vapor mixture to first temperature by removal of sensible heat QSV . 2. Flash mixture isothermally at this temperature and the system pressure to determine the amount of liquid formed and vapor remaining. Since the temperature is known, the vapor and liquid compositions are known. Therefore, this calculation is only a material balance to determine the split between the vapor and liquid. 3. Calculate the latent heat removal required to condense the liquid amount determined in the flash calculation = QSL. 4. Calculate the total heat removed, in this section ∆QT = QSV + QSL. 5. Calculate Qsv /∆QT, z, and the integrand for the section. For Section Two: Second Temperature Segment 1. Cool vapor mixture to the second temperature by removal of sensible heat QSV . 2. Repeat steps 2 to 5 above, add the integrand and the ∆QT for this section to the QT calculated so far for the previous sections. For Each Succeeding Section Repeat steps indicated above until the bubble point is reached. The integrands and the ∆QT have now been summed so that a plot can be made to determine the area. Also, the total heat removed during the condensation process, QT , © 2002 by CRC Press LLC
9588ch14 frame Page 225 Wednesday, September 5, 2001 9:57 PM
is now known. The coolant flow rate, m, can be determined if the allowable temperature rise, ∆T, is set. m=
QT C p ∆T
Knowing m and ∆QT for each section, the temperature of the coolant may now be determined for each section.
© 2002 by CRC Press LLC
9588ch15 frame Page 227 Wednesday, September 5, 2001 9:58 PM
15
Control of VOC and HAP by Biofiltration
15.1 INTRODUCTION A biofilter consists of a bed of soil or compost beneath which is a network of perforated pipe. Contaminated air flows through the pipe and out the many holes in the sides of the pipe thereby being distributed throughout the bed. A biofilter works by providing an environment in which microorganisms thrive. The organic substrate provides the salts and trace elements for the bacteria, and the VOC provides the food source. This action is an adaptation of biogdegradation in which the air cleanses itself naturally. The microorganisms are the same that degrade organic wastes in nature and in wastewater treatment plants. These microorganisms in a moist environment oxidize organic compounds to CO2 and water. The soil or compost beds provide a network of fine pores with large surface areas. In soils the pores are smaller and less permeable than in compost. Therefore, soil requires larger areas for biofiltration. Biofiltration is a relatively new technology in the U.S. used for effectively controlling Volatile Organic Compound (VOC) emissions, organic and inorganic air tonics, and odor from gaseous streams. This technology has been used in Europe for many years and is considered to be a Best Available Control Technology (BACT) for treating contaminated gaseous streams. Biofilters function efficiently and economically for removing low concentrations (less than 1000 to 1500 ppm as methane) of VOCs, air tonics, and odor. Biofiltration offers many potential advantages over existing control technologies, such as low installation and operation costs, low maintenance requirements, long life for the biofilter, and environmentally safe operation. Also, many of the existing control technologies cannot be economically applied to dilute gas stream treatment. Biofilters are effective systems for removing pollutants from gaseous streams. The percent removals possible vary in the literature. For odorous compounds, 98 to 99% removal has been reported.1 Reported removal efficiencies for VOCs vary, but are generally in the range of 65 to 99%.1-3 The removal rates depend on the characteristics of the biofilter, such as the media, temperature, pH, moisture content, and gas residence time, as well as on the properties of the compounds being removed by the biofilter. Biofilters can also remove particulates and liquids from gas streams. However, care must be taken because particulates or greasy liquids can function to plug the biofilter. Biofilters have been applied for many uses. Their historical use has been for odor control. Industries including chemical manufacturing, pharmaceutical manufacturing, food processing, wastewater facilities, and compost operations have successfully used this technology for odor control. Biofiltration has also been used to
© 2002 by CRC Press LLC
9588ch15 frame Page 228 Wednesday, September 5, 2001 9:58 PM
reduce VOC emissions in aerosol propellant operations.4 Fuel and solvent operations have also successfully used biofiltration to control emissions.
15.2 THEORY OF BIOFILTER OPERATION A biofilter is a bed of media which supports the growth of microorganisms. Biotransformations act along with adsorption, absorption, and diffusion to remove contaminants from the gaseous stream. The gaseous stream is pumped through perforated pipes located at the bottom of the biofilter. The gas passes upward through the biofilter media. The contaminants in the gas are either adsorbed onto the solid particles of the media or absorbed into the water layer that exists on the media particles. The rate of adsorption is related to the contaminant type in the gas stream. The media of the filter functions both to supply inorganic nutrients and as a supplement to the gas stream being treated for organic nutrients. As the contaminated air flows upward through the bed, VOCs sorb onto the organic surface of the soil or compost. The sorbed gases are oxidized by the microorganisms to CO2. The volatile inorganics are also sorbed and oxidized to form calcium salts. The biofilters are actually a mixture of activated carbon, alumina, silica, and lime combined with a microbial population that enzymatically catalyzes the oxidation of the sorbed gases. The sorption capacity is relatively low, but the oxidation regenerates the sorption capacity. Gases are inherently more biodegradable than solids and liquids because they are more molecularly dispersed. Removal and oxidation rates depend upon the biodegradability and reactivity of the gases. Half-lives of contaminants range from minutes to months. Table 15.1 lists compounds in order of their degradability. In the case of hydrocarbons, aliphatics degrade faster than aromatics. Even though pollutants are being put into the ground, loading rates are low, gases degrade rapidly, oxygen is in excess, and the soil does not become contaminated.
TABLE 15.1 Gases Classified According to Their Degradability Rapidly Degradable VOCs Alcohols Aldehydes Ketones Ethers Esters Organic acids Amines Thiols Other molecules with O, N, or S functional groups
© 2002 by CRC Press LLC
Rapidly Reactive VOCs
Slowly Degradable VOCs
Very Slowly Degradable VOCs
H 2S NOX (not N2O) SO2 HCl NH3 PH3 SiH4 HF
Hydrocarbons Phenols Methylene chloride
Halogenated hydrocarbons Polyaromatic hydrocarbons CS2
9588ch15 frame Page 229 Wednesday, September 5, 2001 9:58 PM
The microorganisms exist in the slime layer, or biolayer on the surface of the media particles. Diffusion occurs through the water layer to the microorganisms. Once the contaminants are adsorbed or absorbed, the microorganisms begin to function. The contaminants provide a food source for the microorganisms. Through biotransformation of the food source, end products are formed, including carbon dioxide, water, nitrogen, mineral salts, and energy to produce more microorganisms. Oxidation of adsorbed compounds allows the biofilter to self regenerate. Adsorption sites are continually becoming available as oxidation by microorganisms occur. Overloading of the biofilter results when adsorption is occurring faster than oxidation. The result of overloading is to allow the contaminants to pass through the biofilter.
15.3 DESIGN PARAMETERS AND CONDITIONS A biofilter can have many design configurations, but they all function similarly, as described by the process theory discussed above. A biofilter can be open or enclosed, it can be built directly into the ground or in a reactor vessel, and it can be single or multiple bed. Figure 15.1 presents a typical biofilter configuration. The basic components of a biofilter system include the filter media packed bed, an air distribution system under the filter bed, a humidifier to saturate the incoming gas stream, and a blower to move the gas stream through the system. Optional components include a heat exchange chamber to cool or heat the gas stream to optimal temperature for the filter bed and a water sprinkler system to apply moisture directly to the filter media surface.
15.3.1 DEPTH
AND
MEDIA
OF
BIOFILTER BED
The depth of biofilter media range for 0.5 to 2.5 m, with 1 m being the typical depth of a biofilter. Many different media types have been used in biofilters. Some examples include soil, compost, sand, shredded bark, peat, heather, volcanic ash, and a mixture of these components. Figure 15.2 shows a typical biofilter bed. Often polystyrene spheres or peat granules may be added to increase the structural support of the system and to increase the adsorptive capacity of the media. The two most commonly discussed media in the literature are soil and compost. Typical parameters required for the media, regardless of which media type is chosen, include a neutral pH range, pore volumes of greater than 80%, and a total organic content of 55% or greater. The properties of the media are important to the successful operation of the biofilter Soil is a stable choice for media in that is does not degrade. However, it contains fewer and less complex microorganisms than compost media. Compost has more and more complex microorganisms than sand. It also has higher air and water permeability. The buffering capacity of compost is also very good. However, it does not have the stability of sand. With time compost decomposes, and the average particle sizes of the filter media decrease. The choice of media material depends on availability, desired characteristics of the biofilter, and the compounds that are to be removed. The useful life of the media is typically up to 5 years. After this time period, replacement is usually necessary. Fluffing, or turning, of the media material in the © 2002 by CRC Press LLC
9588ch15 frame Page 230 Wednesday, September 5, 2001 9:58 PM
FIGURE 15.1 Typical open biofilter configuration.
© 2002 by CRC Press LLC
9588ch15 frame Page 231 Wednesday, September 5, 2001 9:58 PM
FIGURE 15.2 Typical biofilter bed.
biofilter may be required at shorter intervals to prevent excessive compaction and settling. The turning and occasional replacement of the biofilter material are the two major components of maintenance required by this treatment system.
15.3.2 MICROORGANISMS Three types of microorganisms are generally present in a biofilter. These include fungi, bacteria, and actinomycetes. Actinomycetes are organisms which resemble both bacteria and fungi. The growth and activity of the microorganisms is dependent on the environment of the biofilter. The environment relies on such parameters as ample oxygen supply, absence of toxic materials, ample inorganic nutrients for the microorganisms, optimum moisture conditions, appropriate temperatures, and neutral pH range. All of these parameters must be controlled in the biofilter in ensure successful removal efficiencies. The microorganisms are fairly hearty, so staying in an acceptable range of these parameters allows microorganism survival. Start up of a biofilter process requires some acclimation time for the microorganisms to grow specific to the compounds in the gaseous stream. For easily degradable substances, this acclimation period is typically around 10 days.2 For more complex compounds or for mixtures, this acclimation process may require additional time. The acclimation process also allows the microorganisms to develop tolerance or acceptance for compounds they may find to be toxic in nature. Often, biofilters are not used continuously in the treatment process. They may be employed intermittently or seasonally, depending on the treatment process. The biomass has been shown to be able to be viable for shut downs of approximately 2 weeks. Also, if nutrient and oxygen supplies are continued, the biomass may be maintained for up to 2 months.
© 2002 by CRC Press LLC
9588ch15 frame Page 232 Wednesday, September 5, 2001 9:58 PM
15.3.3 OXYGEN SUPPLY A major factor that can limit the biooxidation rate is the oxygen available to the microorganisms. Typically, a minimum of 100 parts of oxygen per part of gas must be supplied. This is usually easily supplied in a biofilter since the gaseous streams being pumped through the biofilter usually contain excess oxygen, enough to keep the biofilter well supplied. Anaerobic zones need to be avoided to ensure that the compounds are biotransformed and to prevent any anaerobic zone odors (primarily hydrogen sulfide) from forming.
15.3.4 INORGANIC NUTRIENT SUPPLY Besides oxygen, microorganisms require certain nutrients to sustain their activity and growth. These are typically nitrogen, phosphorous, and some trace metals. Trace metals are almost always well supplied in the media material. Nitrogen and phosphorous may need to be added, depending on the media characteristics. For aerobic microorganisms, the O/N/P ratio is estimated as 100/5/1.
15.3.5 MOISTURE CONTENT The literature agrees that moisture content is the most critical operational parameter for the successful operation of a biofilter. The gaseous streams tend to dry out the biofilter media. Too little water will result in decreased activity of the microorganisms, and perhaps transfer of the adsorbed contaminants out of the filter and into the atmosphere. Too much water can also cause problems, such as anaerobic zones, with the potential of producing odors, and increases in the headloss of the system. Optimal water contents vary in the literature, but generally the range of 20 to 60% by weight is accepted. Moisture can be added to the system in two ways: humidification of the gas stream or direct application of water to the biofilter surface. Humidification of the gas stream occurs as a pretreatment to the biofilter. The humidifier process location is shown in Figure 15.1. Typically, the degree of saturation suggested2 is at least 95%,2 with saturation percentages of 99% and 100% quoted as the optimum. Surface sprays to the biofilter surface can also be used. Care must be taken that the water droplets are small. Typically water droplet diameters of less than 1 mm are suggested, in order to prevent compaction of the biofilter. The maximum water loading rate suggested3 is 0.5 gal/ft2-h.
15.3.6 TEMPERATURE The microorganisms’ activity and growth is optimal in a temperature range of 10 to 40°C. Higher temperatures will destroy the biomass, while lower temperatures will result in lower activities of the microorganisms. In winter, heating of the off gas streams may be required before passing the streams through the biofilter. This will ensure an acceptable rate of degradation by the microorganisms. High temperature off gases may need to be cooled before the biofilter to ensure the survival of the microorganisms. © 2002 by CRC Press LLC
9588ch15 frame Page 233 Wednesday, September 5, 2001 9:58 PM
15.3.7
PH OF THE
BIOFILTER
The pH in the biofilter should remain near neutral, in the range of 7 to 8. When inorganic gases are treated, inorganic acids may be produced. For example, treated H2S will produce H2SO4. Other inorganic acids which can be formed include HCl and HNO3. These acids can cause lowered pH in the media over time. Carbon dioxide production by the microorganisms can also lower the pH over time. The media typically has some inherent buffering capacity to neutralize small changes in the pH. However, if the buffering capacity is not sufficient, lime may need to be added to the biofilter for pH adjustment.
15.3.8 LOADING
AND
REMOVAL RATES
The loading rate of the biofilter can be used to determine the size of the system required. Loading rates can be expressed in three ways: flow rates of gases through the bed, gas residence times, and removal rates. Flow rates of gas into the bed range from 0.3 to 9.5 m3/min-m2. The typical range5 is 0.3–1.6 m3/min-m2. Off gas rates are typically2 around 1000 to 150,000 m3/h. Higher loading rates can result in overloading the bed and pass through of contaminants. Gas residence times, the time the gas actually spends in contact with the biofilter material, is the time available for adsorption and absorption to occur. Suggested gas residence times are a minimum of 30 s for compost media5 and a minimum of 1 min for soil media.6 Slightly longer residence times are suggested for inorganic gases. Removal rates depend on the compound and the media type in the biofilter. They are typically reported in units of g/kg of dry media/day. Williams and Miller5 provide a list of removal rates for various compounds and various media types. Generally, the lower-molecular-weight, less-complex compounds are more easily degraded and more quickly removed in a biofilter.
15.3.9 PRESSURE DROP The pressure drop through the filter bed depends on the media type, porosity, moisture content, and compaction of the media. The porosity of the media can change with time as the filter media becomes more compacted. Fluffing or replacing the media over time can help to prevent compaction and higher pressure drops. Higher pressure drops result in more energy required to overcome the back pressure of the filter bed. Typical pressure drops range from 1 to 3 in. of water.7 Typical power consumption2 for a biofilter is in the range of 1.8 to 2.5 KWh/1000 m3. The pressure drop is related to the surface load of contaminants and the media type.
15.3.10 PRETREATMENT
OF
GAS STREAMS
As discussed previously, humidification of the gas stream may be required prior to the biofilter to provide adequate moisture for the microorganisms. Other pretreatment necessary may include removing particulates. Though the biofilter is capable of removing particulates, the solid matter can cause clogging of the biofilter and gas distribution system. The gas stream also may need to be heated or cooled to meet the temperature requirements of the microorganisms. © 2002 by CRC Press LLC
9588ch15 frame Page 234 Wednesday, September 5, 2001 9:58 PM
15.4 BIOFILTER COMPARED TO OTHER AVAILABLE CONTROL TECHNOLOGY Other control technology for the control of VOCs and air toxics include incineration, carbon adsorption, condensation, and wet scrubbing. The advantage that biofilters have over all of these technologies is their ability to treat dilute gas streams in a cost-effective manner. Shortcomings associated with the other available technologies include high fuel use, high maintenance requirements, high capital costs, and the pollution of wash water or air streams in the removal process. Other technologies often take the pollution from one form and place it in another, for example, removing contamination from an air stream and placing it in the wash water. Biofilters allow the biotransformation of the pollution to less- or nontoxic forms and reduced volumes. Incineration works as a control technology for highly concentrated waste streams. For dilute streams, the process is too energy intensive to be practical. It is also more expensive to install and operate than a biofilter system. Also, there has been much public opposition to incineration treatment methods. Carbon adsorption is a very effective technology. However, it is very expensive to use, which is especially prohibitive to small operations. If the carbon is regenerated on site, the costs will be less than if it is not regenerated on site. Condensation is an effective technology for treating concentrated and pure off gases. As with incinerators, the treatment of dilute streams is too energy intensive to accomplish cost effectively. Wet scrubbing technology is also more expensive than biofilter systems.
15.5 SUCCESSFUL CASE STUDIES Throughout the literature there are successful case studies quoted for a variety of applications of the biofilter. For example, gases from an animal rendering plant process were treated in a soil biofilter for odor removal. Removal rates of 99.9% were obtained.7 Another application used a sludge compost biofilter to treat a gas stream containing volatile amine compounds. Removals exceeding 95% were obtained.1 A prototype biofilter with soil media was used to treat light aliphatic compounds and trichloroethylene from aerosol propellant releases. Reduction rates of 90% were obtained.4 The various case studies reinforce that fact that this technology can be successfully applied to various gas stream treatments.
15.6 FURTHER CONSIDERATIONS Biofiltration offers a cost-competitive and competent technology alternative for the treatment of gas streams containing VOCs, air toxics, and odors. Its success has been proven in Europe and is starting to be applied more in the U.S. As the U.S. Clean Air Act begins to focus more on smaller generators of VOCs and air toxics, the biofilter will most likely see more and broader applications. Adler8 discusses current usage of biofiltration in the U.S. and Europe. He presents guidelines for scaleup and design of biofiltration processes. He also presents economic data for two cases comparing biofiltration to other means of control. In the case of methanol, © 2002 by CRC Press LLC
9588ch15 frame Page 235 Wednesday, September 5, 2001 9:58 PM
a readily biodegradable molecule, biofiltration appears to be exceptionally good when compared to other technologies. The second case involved toluene. Here biofiltration is only in the middle range of costs compared to other technologies. Design of a biofilter may require a pilot study, especially if the gas stream contains a mixture of compounds. Often, co-metabolism will occur which will affect the degradation rates and perhaps some of the design parameters. Successful biofiltration requires a design to ensure a proper environment for the microorganisms. This includes being able to control and monitor such parameters as moisture content, pH, temperature, and nutrient supply.
REFERENCES 1. Williams, T. O. and Miller, F. C., Odor control using biofiltration, BioCycle, 72–77, October 1992. 2. Leson, G. and Winer, A. M., Biofiltration: An innovative air pollution control technology for VOC emissions, J. Air Waste Manage. Assoc., 41(8), 1045–1054, 1991. 3. Speece, R. E., Biofiltration of gaseous contaminants, State-of-the-art report to Weyerhauser Corporation, May 24, 1995. 4. Kampbell, D. H. et al., Removal of volatile aliphatic hydrocarbons in a soil bioreactor, J. Air Poll. Contr. Assoc., 37(10), 1236–1240, 1987. 5. Williams, T. O. and Miller, F. C., Biofilters and facility operations, BioCycle, 75–79, November, 1992. 6. Bohn, H. L., Soil and compost filters of malodorous gases, J. Air Poll. Contr. Assoc., 25(9), 953–955, 1975. 7. Bohn, H. L. and Bohn, R. K., Soil beds weed out air pollutants, Chem. Eng., 95(6), 73–76, 1988. 8. Adler, S. F., Biofiltration — a primer, Chem. Eng. Progr., 97(4), 33–41, April 2001.
© 2002 by CRC Press LLC
9588ch16 frame Page 237 Wednesday, September 5, 2001 10:00 PM
16
Membrane Separation
16.1 OVERVIEW Membrane separation has developed into an important technology for separating VOCs and other gaseous air pollutants from gas streams during the past 15 years. The first commercial application was installed in 1990, and more than 50 systems have been installed in the chemical process industry worldwide.1 The technology utilizes a polymeric membrane that is more permeable to condensable organic vapors, such as C3+ hydrocarbons and aromatics, than it is to noncondensable gases such as methane, ethane, nitrogen, and hydrogen. The air stream to be treated is separated into a permeate that contains concentrated VOCs and a treated residue stream that is depleted of VOC. Because the technology concentrates the VOC gas stream, it can be used with a condenser to recover the VOC. It is best suited for relatively low-flow streams containing moderate VOC concentration. The typical overall VOC recovery process consists of two steps: (1) compression and condensation, and (2) membrane separation.2 A mixture of vapor and air is compressed to about 45 to 200 psig. The compressed mixture is cooled and condensed vapor is recovered. Uncondensed organics are separated from the gas stream and concentrated in the permeate by the membrane. The treated gas is vented from the system and the permeate is drawn back to the compressor inlet.
16.2 POLYMERIC MEMBRANES The polymeric membrane consists of a layer of nonwoven fabric that serves as the substrate, a solvent-resistant microporous support layer for mechanical strength, and a thin film selective layer that performs the separation. It is manufactured as flat sheet and is wrapped into a spiral-wound module. Feed gas enters the module and flows between the membrane sheets. Spacers on the feed and permeate side of the sheets create flow channels.3
16.3 PERFORMANCE Membranes are best suited for treating VOC streams that contain more than 1,000 ppmv of organic vapor where recovered product has value. Typical VOC recovery using membrane separation ranges from 90 to 99%, and can reduce the VOC content of the vented gas to 100 ppm or less.3,4 A list of VOCs that can be recaptured using membrane separation is provided in Table 16.1.
© 2002 by CRC Press LLC
9588ch16 frame Page 238 Wednesday, September 5, 2001 10:00 PM
TABLE 16.1 VOCs That Can Be Captured with Membrane Technology2 Acetaldehyde Acetone Acetonitrile Benzene Butane Carbon tetrachloride CFC-11 CFC-12 CFC-113 Chlorine Chloroform Ethylene dichloride Ethylene oxide HCFC-123
Hexane Methanol Methyl bromide Methyl chloride Methyl chloroform Methyl isobutyl ketone Methylene chloride Perfluorocarbons Propylene oxide Styrene Toluene Trichloroethylene Vinyl chloride Xylenes
16.4 APPLICATIONS Applications for membrane separation include vent streams from the production and processing of vinyl chloride, ethylene, propylene, methylene chloride, and ammonia. In polyolefin plants, purification of ethylene and propylene feedstock in a splitter column is a common first step. When nitrogen, hydrogen, and methane are present in the feed, they build up in the column overhead stream and must be vented. Vent streams from reactor recycle and reactor purge also must be treated. The vent streams may be fed to a membrane separator where valuable feedstock is recovered as the permeate. In several membrane applications where the primary objective is product recovery, the residue stream, which still contains a small amount of VOC that did not permeate through the membrane, is sent to a flare. Vent gases from ammonia plant reactors typically contain hydrogen, nitrogen, methane, and argon. Glassy polymer membranes, such as polysulfone, are much more permeable to hydrogen than to the other components. Approximately 87% of the hydrogen can be recovered from the vent gas and recycled.5
REFERENCES 1. Lokhandwala, K. A. and Jacobs, M., New membrane applications in gas processing, presented at the 79th Annual Gas Processors Assoc. Conv., Atlanta, GA, March 2000. 2. Simmons, V. et al., Membrane systems offer a new way to recover volatile organic air pollutants, Chem. Eng., 101(9), 92, September 1994. 3. Jacobs, M., Gottschlich, D., and Buchner, F, Monomer recovery in polyolefin plants using membranes — an update, presented at the 1999 Petrochemical World Review, Houston, TX, March 23–25, 1999. © 2002 by CRC Press LLC
9588ch16 frame Page 239 Wednesday, September 5, 2001 10:00 PM
4. Baker, R. W. and Jacobs, M., Improve monomer recovery from polyolefin resin degassing, Hydrocarbon Proc., 75(3), 49, March 1996. 5. Baker, R. W. et al., Recover feedstock and product from reactor vent streams, Chem. Eng. Progr., 99(12), 51, 2000.
© 2002 by CRC Press LLC
9588ch17 frame Page 241 Wednesday, September 5, 2001 10:01 PM
17
NOx Control
There are a number of oxides of nitrogen, including nitrous oxide (N2O), nitric oxide (NO), nitrogen dioxide (NO2), nitrogen trioxide (N2O3), and nitrogen pentoxide (N2O5), that are referred to collectively as NOx. The two oxides of nitrogen that are of primary concern to air pollution are NO and NO2. NO is a colorless gas that is a precursor to NO2 and is an active compound in photochemical reactions that produce smog. NO2 is a reddish brown gas that gives color to smog and can contribute to opacity in flue gas plumes from stacks. NO2 is a criteria pollutant with a National Ambient Air Quality Standard of 100 µg/m3, or .053 ppm, annual average. It is also a precursor to nitric acid, HNO3, in the atmosphere and is a major contributor to acid rain, although less important than SO2, which is discussed in the next chapter. Nitric acid contributes only one proton per molecule while sulfuric acid has two protons per molecule, and mass emissions of sulfur compounds are larger than oxides of nitrogen. Finally, NOx and volatile organic compounds (VOC) react photochemically in a complex series of reactions to produce smog, which includes ozone, NO2, peroxyacetyl nitrate (PAN), peroxybenzoyl nitrate (PBN) and other trace oxidizing agents. By far the largest source of NOx is combustion, although there are other industrial sources such as nitric acid manufacturing. Figure 17.1 shows the relative contribution from NOx emission sources. The large amount of NOx generated at coal-fired electric power plants is evident, and the very large contribution from motor vehicles and other forms of transportation, including ships, airplanes, and trains, is pronounced. Figure 17.2 shows that total NOx emissions have been fairly steady at about 23 tons per year, despite industrial growth and a growing number of vehicles on the road. Preventing an increase in total NOx emissions can be attributed to the increased use of NOx controls, especially in automobiles and in industrial fuel consumption.
17.1 NOX FROM COMBUSTION NOx is generated during combustion from three mechanisms: (1) thermal NOx, (2) prompt NOx, and (3) fuel NOx. Understanding these mechanisms enables one to utilize control methods for NOx emissions.
17.1.1 THERMAL NOX The thermal NOx mechanism was first proposed by Zeldovich1 and involves radicals to produce the overall reaction of combining oxygen and nitrogen: O 2 ↔ 2O
© 2002 by CRC Press LLC
(17.1)
9588ch17 frame Page 242 Wednesday, September 5, 2001 10:01 PM
FIGURE 17.1 NOx emission sources.
FIGURE 17.2 NOx emission trends in the U.S.
O + N 2 ↔ NO + N
(17.2)
N + O2 ↔ NO + O
(17.3)
N 2 + O2 ↔ 2 NO
(17.4)
The overall reaction that produces NO2 is NO + 12 O2 ↔ NO2 © 2002 by CRC Press LLC
(17.5)
9588ch17 frame Page 243 Wednesday, September 5, 2001 10:01 PM
TABLE 17.1 Equilibrium Constants for NO and NO2 Formation N2 + O2 ↔ 2NO KP1
°F 80 1340 2240 3500
1.0 7.5 1.1 3.5
× × × ×
NO + ½O2 ↔ NO2 KP2
10–30 10–9 10–5 10–3
1.4 1.2 1.1 2.6
× × × ×
106 10–1 10–2 10–3
TABLE 17.2 Equilibrium Concentrations Air 21% O2, 79% N2
Flue Gas 3.3% O2, 76% N2
°F
NO (ppm)
NO2 (ppm)
NO (ppm)
NO2 (ppm)
80 980 2060 2912
3.4 × 10–10 2.3 800 6100
2.1 × 10–4 0.7 5.6 12
1.1 × 10–10 0.8 250 2000
3.3 × 10–5 0.1 0.9 1.8
Both thermodynamics and kinetics are important to the formation of thermal NOx, so both concentration and temperature influence the amount of NOx produced. The thermodynamic equilibrium concentrations for reactions 17.4 and 17.5 are
[P ]
2
K P1 =
NO
[P ][P ] N2
KP2 =
[P ] [ P ][ P ] NO2
NO
(17.6)
O2
1 2
(17.7)
O2
Equilibrium constants at different temperatures are listed in Table 17.1. Equilibrium concentrations calculated from Equations 17.6 and 17.7 are presented in Table 17.2 for oxygen and nitrogen concentrations in air and in a typical combustion source flue gas. Based on thermodynamic equilibrium alone, calculated NOx concentrations in flame zones at 3000 to 3600°F would be about 6000 to 10,000 ppm, and the NO to NO2 ratio would be 500:1 to 1000:1. At typical flue gas exit temperatures of 300 to © 2002 by CRC Press LLC
9588ch17 frame Page 244 Wednesday, September 5, 2001 10:01 PM
600°F, the NOx concentration would be very low at less than 1 ppm, and the NO to NO2 ratio would be very low at 1:10 to 1:10,000. Yet typical NOx emissions from uncontrolled natural-gas fired boilers are 100 to 200 ppm. Typical NOx emissions from uncontrolled fuel-oil-fired and coal-fired boilers, which have higher flame temperatures, are 200 to 400 ppm and 300 to 1200 ppm, respectively. And the typical NO to NO2 ratio in boiler emissions is 10:1 to 20:1. The reason for the observed NOx concentrations being so different from equilibrium expectations is the effect of kinetics. The reaction rate is a strong function of temperature. Gases reside in the flame zone of a burner for a very short time, less than 0.5 s. The time required to produce 500 ppm NO at 3600°F is only about 0.1 s, but at 3200°F the required time is 1.0 s. Once the gases leave the flame zone, reaction rates are reduced by orders of magnitude, so NO formation stops quickly. Also, the reversible reactions shown by Equations 17.4 and 17.5 slow to nearly a halt, thereby “freezing” the NOx concentration and the ratio of NO to NO2.
17.1.2 PROMPT NOX NOx concentrations near the flame zone for hydrocarbon fuels demonstrate less temperature dependence than would be expected from the thermodynamic and kinetics considerations of the Zeldovich mechanism discussed above for thermal NOx. Near the flame zone, radicals such as O and OH enhance the rate of NOx formation. Hence, some NOx will form despite aggressive controls on flame temperature and oxygen concentration.
17.1.3 FUEL NOX Some fuels contain nitrogen, e.g., ammonia or organically bound nitrogen in hydrocarbon compounds. For coal-fired burners, fuel-NOx typically falls in the range of 50 to 70% of the total NOx emissions.2 Nitrogen in the fuel reacts with oxygen regardless of the flame temperature or excess oxygen concentration in the combustion air. Carbon–nitrogen bonds are broken more easily than diatomic nitrogen bonds, so fuel-NOx formation rates can be higher than thermal-NOx. Combustion control techniques that aim at reducing thermal-NOx formation by reducing flame temperature may not be effective for fuels that have high nitrogen content.
17.2 CONTROL TECHNIQUES Two primary categories of control techniques for NOx emissions are (1) combustion controls, and (2) flue gas treatment. Very often more than one control technique is used in combination to achieve desired NOx emission levels at optimal cost. When evaluating control technology, it is desirable to quantify the capability for percent reduction of NOx. This can be difficult, however, because the baseline operations may or may not be established at good combustor operation, and because the performance of individual technologies is not additive. And there are a number of techniques that can be used in a wide variety of combinations.
© 2002 by CRC Press LLC
9588ch17 frame Page 245 Wednesday, September 5, 2001 10:01 PM
17.2.1 COMBUSTION CONTROL TECHNIQUES A variety of combustion control techniques are used to reduce NOx emissions by taking advantage of the thermodynamic and kinetic processes described above. Some reduce the peak flame temperature; some reduce the oxygen concentration in the primary flame zone; and one, reburn, uses the thermodynamic and kinetic balance to promote reconverting NOx back to nitrogen and oxygen. 17.2.1.1 Low-Excess Air Firing Combustors tend to be easier to operate when there is plenty of oxygen to support combustion, and operators like to adjust the air-to-fuel ratio to produce a stable and hot flame. By simply cutting back the amount of excess air, the lower oxygen concentration in the flame zone reduces NOx production. In some cases where too much excess air has become normal practice, thermal efficiency is improved. However, low excess air in the resulting flame may be longer and less stable, and carbon monoxide emissions may increase. Tuning the combustion air requires minimal capital investment, possibly some instrumentation and fan or damper controls, but it does require increased operator attention and maintenance to keep the system in optimal condition. Depending on the prior operating conditions, combustion air tuning can produce NOx reduction of 0 to 25%.3 Tuning ranges from simple adjustments to advanced modeling that incorporates neural networks. Applying advanced optimization systems at four coal-fired power plants resulted in NOx emission reductions of 15 to 55%.4 17.2.1.2 Overfire Air The primary flame zone can be operated fuel rich to reduce oxygen concentration, then additional air can be added downstream. This overfire air provides oxygen to complete combustion of unburned fuel and oxidizes carbon monoxide to carbon dioxide, creating a second combustion zone. Because there is so little fuel in this overfire zone, the peak flame temperature is low. Thus, NOx formation is inhibited in both the primary and overfire combustion zones. 17.2.1.3 Flue Gas Recirculation In this technique, some of the flue gas, which is depleted in oxygen, is recirculated to the combustion air. This has two effects: (1) the oxygen concentration in the primary flame zone is decreased, and (2) additional nitrogen absorbs heat, i.e., acts as a heat sink, and reduces the peak flame temperature. NOx reduction as a function of the amount of recirculated flue gas is plotted in Figure 17.3.5 17.2.1.4 Reduce Air Preheat Combustion air often is preheated in a recuperator with the heat from the flue gas. This conserves energy by recovering the heat in the flue gas. However, it also raises the peak flame temperature because the combustion air absorbs less heat from the
© 2002 by CRC Press LLC
9588ch17 frame Page 246 Wednesday, September 5, 2001 10:01 PM
FIGURE 17.3 Effectiveness of flue gas recirculation. (Reproduced with permission of the American Institute of Chemical Engineers, Copyright © 1994 AIChE. All rights reserved.)
combustor prior to reacting with the fuel. Reducing air preheat lowers the flame temperature to reduce the formation of thermal NOx. 17.2.1.5 Reduce Firing Rate Peak flame temperature is determined by the complete heat balance in the combustion chamber, including radiant heat losses to the walls of the chamber. Reducing both air and fuel proportionately would result in the same flame temperature if only fuel, air, and combustion products were considered. However, reducing fuel and air in a fixed size chamber results in a proportionately larger heat loss to the chamber walls and peak flame temperature is reduced. 17.2.1.6 Water/Steam Injection Injecting water or steam into the combustion chamber provides a heat sink that reduces peak flame temperature. However, a greater effect is believed to result from the increased concentration of reducing agents within the flame zone as steam dissociates into hydrogen and oxygen. Compared to standard natural draft, in natural gas-fired burners, up to 50% NOx reduction can be achieved by injecting steam at a rate up to 20 to 30% of the fuel weight.6 17.2.1.7 Burners out of Service (BOOS) In a large, multiburner furnace, selected burners can be taken out of service by cutting their fuel. The fuel is redistributed to the remaining active burners, and the total fuel rate is not changed. Meanwhile, combustion air is unchanged to all burners. This becomes an inexpensive way to stage the combustion air. The primary flames
© 2002 by CRC Press LLC
9588ch17 frame Page 247 Wednesday, September 5, 2001 10:01 PM
operate fuel rich and depleted in oxygen, reducing NOx formation. Outside the hot flame zone, but still inside the combustion chamber where combustion goes to completion, the additional combustion air burns the remaining fuel at a reduced flame temperature. Test results on a coal-fired boiler demonstrated NOx emission reduction of 15 to 30%.7 17.2.1.8 Reburn A second combustion zone after the primary flame zone can be established by adding additional hydrocarbon fuel outside of the primary flame zone. NOx is reduced by reaction with hydrocarbon radicals in this zone.8 Overfire air is added after reburn to complete the combustion process at a low temperature flame. Results from five coal-fired boilers from 33 to 158 MW net capacity show NOx reduction from baseline levels of 58 to 77%.9 17.2.1.9 Low-NOx Burners Low-NOx burners are designed to stage either the air or the fuel within the burner tip. The principle is similar to overfire air (staged air) or reburn (staged fuel) in a furnace. With staged-air burners, the primary flame is burned fuel rich and the low oxygen concentration minimizes NOx formation. Additional air is introduced outside of the primary flame where the temperature is lower, thereby keeping the thermodynamic equilibrium NOx concentration low, but hot enough to complete combustion. The concept of a staged-air burner is illustrated in Figure 17.4. Staged-fuel burners introduce fuel in two locations. A portion of the fuel is mixed with all of the combustion air in the first zone, forming a hot primary flame with abundant excess air. NOx formation is high in this zone. Then additional fuel is introduced outside of the primary flame zone, forming a low-oxygen zone that is still hot enough for kinetics to bring the NOx concentration to equilibrium in a short period of time. In this zone, NOx formed in the primary flame zone reverts back to nitrogen and oxygen. A staged fuel burner is illustrated in Figure 17.5. Low NOx burners can reduce NOx emissions by 40 to 65% from emissions produced by conventional burners. Because low-NOx burners stage either the air or the fuel, the flame zone is lengthened. The typical flame length of low-NOx burners is about 50 to 100% longer than that of standard burners. This can cause a problem in some retrofit applications if the longer flame impinges on the walls of the combustion chamber. Flame impingement can cause the chamber walls to erode and fail. While burner replacement may be an easy retrofit technique for NOx control for many furnaces, it cannot be used in all situations. It is recommended that the flame length should be kept to a third of the firebox height for long vertical cylindrical heaters, and to no more than two thirds of the firebox height for low-roof cabin heaters.10 Low-NOx burners also have been developed for coal-fired applications, where NOx concentrations are significantly higher than produced in liquid and gaseous fuel applications. Using low-NOx burners alone, a NOx emission level of 90 to 140 ppm at 3% O2 can be achieved.11 © 2002 by CRC Press LLC
9588ch17 frame Page 248 Wednesday, September 5, 2001 10:01 PM
FIGURE 17.4 Staged air low-NOx burner. (Courtesy of John Zink Company, LLC.)
FIGURE 17.5 Staged fuel low-NOx burner. (Courtesy of John Zink Company, LLC.) © 2002 by CRC Press LLC
9588ch17 frame Page 249 Wednesday, September 5, 2001 10:01 PM
17.2.1.10 Ultra Low-NOx Burners Ultra low-NOx burners have been developed that incorporate mechanisms beyond simply staging air or fuel as designed in low-NOx burners. They may incorporate flue gas recirculation within the furnace that is induced by gas flow and mixing patterns, and use additional levels of air and/or fuel staging. High fuel gas pressure or high liquid fuel atomization pressure is used to induce recirculation. Also, ultra low-NOx burners may use inserts to promote mixing to improve combustion despite low oxygen concentrations in the flame. Remember the “three Ts” of good combustion discussed in Chapter 13 — time, temperature, and turbulence. Good combustion at low oxygen concentration is essential to balance low NOx formation while avoiding soot and excess CO emissions. Ultra low-NOx burners for gas-fired industrial boilers and furnaces have demonstrated the capability of achieving 10 to 15 ppm NOx on a dry basis corrected to 3% oxygen.12
17.2.2 FLUE GAS TREATMENT TECHNIQUES 17.2.2.1 Selective Noncatalytic Reduction (SNCR) Selective noncatalytic reduction uses ammonia (NH3) or urea (H2NCONH2) to reduce NOx to nitrogen and water. The overall reactions using ammonia as the reagent are 2 NH3 + 2 NO + 1 2 O2 ↔ 2 N 2 + 3H 2O
1600 –1900°F
(17.8)
2 NH3 + 2 NO + O2 + H 2 ↔ 2 N 2 + 4H 2O
1300 –1900°F
(17.9)
The intermediate steps involve amine (NHi) and cyanuric nitrogen (HNCO) radicals. When urea is used, it first dissociates to the primary reactants of ammonia and isocyanic acid.13 No catalyst is required for this process; just good mixing of the reactants at the right temperature and some residence time. The key to this process is operating within the narrow temperature window. Sufficient temperature is required to promote the reaction. The presence of hydrogen in the flue gas, if there is a source of it such as dissociation of steam, increases the operable temperature range at the cooler end. At higher temperatures, ammonia oxidizes to form more NO, thereby wasting ammonia reagent and creating the pollutant that was intended to be removed. Above 1900°F, this reaction dominates. 4 NH3 + 5O2 ↔ 4 NO + 6H 2O
(17.10)
The effect of temperature on SNCR performance is illustrated in Figure 17.6. The critical dependence of temperature requires excellent knowledge of the temperature profile within the furnace for placement of reagent injection nozzles. Computational fluid dynamic (CFD) models often are used to gain this required knowledge. © 2002 by CRC Press LLC
9588ch17 frame Page 250 Wednesday, September 5, 2001 10:01 PM
FIGURE 17.6 SNCR temperature window.
A significant complication for a practical system is designing the system for the variable temperature profiles with turndown of a boiler. Operating a furnace at half load obviously will impact the temperature profile. Nozzles may be installed at multiple locations, then reagent is injected at only the locations appropriate for the load conditions. A second complicating factor is the availability of residence time at the proper temperature. The available residence time also may change with load conditions due to the flue gas flow and the boiler configuration. In a typical application, SNCR produces about 30 to 50% NOx reduction. Some facilities that require higher levels of NOx reduction take advantage of the low capital cost of the SNCR system, then follow the SNCR section with an SCR system (discussed in the following section). Capital costs may be lower than an SCR system alone because the catalyst bed for the SCR can be smaller due to the lower NOx removal requirement for SCR after the SNCR system has removed a significant portion of the NOx. 17.2.2.2 Selective Catalytic Reduction (SCR) A catalyst bed can be used with ammonia as a reducing agent to promote the reduction reaction and to lower the effective temperature. An SCR system consists primarily of an ammonia injection grid and a reactor that contains the catalyst bed. A simplified sketch of the system is shown in Figure 17.7. The following reactions result in reducing NOx in an SCR system. Reaction 17.11 is dominant. Since the NO2 concentration in the flue gas from combustion systems usually is low, then reactions 17.13, 17.14, and 17.15 are not particularly significant to the overall NOx reduction or to the reagent requirement. © 2002 by CRC Press LLC
9588ch17 frame Page 251 Wednesday, September 5, 2001 10:01 PM
FIGURE 17.7 Selective catalytic reduction process schematic.
4 NO + 4 NH3 + O2 → 4 N 2 + 6H 2O
(17.11)
6 NO + 4 NH3 → 5N 2 + 6H 2O
(17.12)
2 NO2 + 4 NH3 + O2 → 3N 2 + 6H 2O
(17.13)
6 NO2 + 8NH3 → 7N 2 + 12 H 2O
(17.14)
NO + NO2 + 2 NH3 → 2 N 2 + 3H 2O
(17.15)
SCR operating considerations include ammonia storage and handling. Ammonia can be in either the anhydrous or aqueous form. A small amount of ammonia, about 5 to 20 ppm, will pass, or “slip,” through the catalyst, which creates an emission of a small amount of a hazardous air pollutant in exchange for reducing NOx. A variety of catalyst types are used for SCR. Precious metals are used in the low temperature ranges of 350 to 550°F. Vanadium pentoxide supported on titanium dioxide is a common catalyst for the temperature range of 500 to 800°F. Zeolites, which are various alumino silicates, are used as high temperature catalysts in the range of 850 to 1100°F. Besides temperature, another catalyst issue is oxidation of SO2 to SO3 in flue gases from fuels that contain sulfur. As discussed in Chapter 18, SO3 results in sulfuric acid mist emissions, which can create opacity that is expensive to control. Tungsten trioxide and molybdenum trioxide are catalysts that minimize sulfur oxidation. Dust loading and catalyst fouling is a problem when there is a significant amount of particulate in the gas stream. SCR systems currently are being retrofit into some coal-fired power plants as a result of stringent NOx control regulations. The catalysts are configured into structured grids to minimize dust accumulation. Some catalyst beds are fit with steam-operated sootblowers to remove dust.
© 2002 by CRC Press LLC
9588ch17 frame Page 252 Wednesday, September 5, 2001 10:01 PM
SCR systems are capable of 70 to 90% NOx reduction. In the common powergeneration application of gas-fired turbines, less than 5 ppm NOx at 15% O2 can be achieved. 17.2.2.3 Low-Temperature Oxidation with Absorption A recently commercialized, proprietary technology for NOx removal is low-temperature oxidation of NOx species to highly soluble N2O5, followed by absorbing the N2O5 in a wet absorption tower. Ozone is used as the oxidizing agent for the reactions: NO + O3 → NO2 + O2
(17.16)
NO2 + O3 → N 2O5 + O2
(17.17)
N 2O5 + H 2O → HNO3
(17.18)
A simplified process schematic is shown in Figure 17.8. Oxidation with ozone takes place at a low temperature of about 300°F, in the temperature range after the combustion air heater and/or economizer in a typical boiler. At high temperatures above 500°F, ozone decomposes rapidly. Ozone can be generated from either ambient air or pure oxygen. For typical small boilers, it is often economical to generate oxygen on site rather than use ambient air.
FIGURE 17.8 Low-temperature oxidation process. (Courtesy of BOC Gases, Inc.)
© 2002 by CRC Press LLC
9588ch17 frame Page 253 Wednesday, September 5, 2001 10:01 PM
The absorption step is accomplished in a spray tower as described in Chapter 11. Caustic is used to neutralize the nitric acid that is formed. Kinetics are a key to this process. Oxidation of NO2 is faster than oxidation of NO, so NO2 concentration is not increased. Also, competing oxidation reactions with CO and SO2 in combustion exhaust gases are relatively slow and do not compete for ozone consumption. CO + O3 → CO2 + O2
(17.19)
SO2 + O3 → SO3 + O2
(17.20)
An advantage of this process over other downstream treatment processes is very high NOx removal efficiency, with 99% removal being reported for an industrial boiler.14 Some facilities may already have a wet caustic absorber for SO2 control, so only the ozone generation and injection systems need to be added. A possible disadvantage for some facilities would be additional nitrate in the wastewater discharge, since NOx is removed in the form of nitric acid. 17.2.2.4 Catalytic Absorption A proprietary catalytic absorption technology called SCONOx™ also has been commercialized recently. The system utilizes a single catalyst for removal of both NOx and CO. First, NO, CO, and hydrocarbons are oxidized to NO2 and CO2. Then NO2 is absorbed in a coating of potassium carbonate on the catalyst. 2 NO2 + K 2CO3 → CO2 + KNO2 + KNO3
(17.21)
After the carbonate coating has been depleted, it is regenerated by passing a dilute stream of hydrogen and carbon dioxide over the catalyst in the absence of oxygen. KNO2 + KNO3 + 4H 2 + CO2 → K 2CO3 + 4H 2O + N 2
(17.22)
Because the regeneration cycle must take place in an oxygen-free environment, a section of catalyst undergoing regeneration must be isolated from the exhaust gases. This is accomplished by dividing the catalyst bed into approximately 5 to 15 or more sections using louvers upstream and downstream of each section to isolate the section for regeneration. Eighty percent of the bed remains on-stream while 20% is being regenerated. One section is always in the regeneration cycle, which lasts about 3 to 5 min, so each oxidation/absorption cycle lasts for 9 to 15 min. The process can operate effectively at temperatures ranging from 300 to 700°F. Significant advantages of this process include the simultaneous removal of CO, hydrocarbons, and NOx to very low levels, and the lack of ammonia storage and emissions. Less than 2 ppm NOx has been demonstrated when used in conjunction with other NOx control technologies, e.g., water injection, that limit the SCONOx inlet NOx concentration to 25 ppm.15 © 2002 by CRC Press LLC
9588ch17 frame Page 254 Wednesday, September 5, 2001 10:01 PM
17.2.2.5 Corona-Induced Plasma Nonthermal plasma consists of ionized gas that can be generated by corona-discharge reactors or electron beams. Plasmas produce chemically active radicals that can oxidize NO to NO2 and N2O5. As discussed above, these NOx species are water soluble and can be removed by absorption. One form of plasma generation is the conventional electrostatic precipitator, which is discussed in Chapter 24. Another specialized generator is the pulse-corona-discharge reactor.16 Corona discharge technology is in the advanced stages of development. However, it has not yet achieved commercial application.
REFERENCES 1. Zeldovich, Y. A., Oxidation of Nitrogen in Combustion, Academy of Sciences of USSR, Institute of Chemical Physics, Moscow-Leningrad, 1947. 2. Pershing, D. W. and Wendt, J. O. L., Relative contributions of volatile nitrogen and char nitrogen to NOx emissions from pulverized coal flames, Ind. Eng. Chem. Proc. Design and Dev., 18(60), 1979. 3. Gregory, M. G., Cochran, J. R., Fischer, D. M., and Harpenau, M. G., The cost of complying with NOx emission regulations for existing coal fueled boilers, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997. 4. Booth, R. C., Kosvic, T. C., and Parikh, N. J., The emissions, operational, and performance issues of neural network control applications for coal-fired electric utility boilers, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997. 5. Wood, S. C., Select the right NOx control technology, Chem. Eng. Progr., 90(1), 32, 1994. 6. John Zink Company, Burner design parameters for flue gas NOx control, Technical Paper 4010B, 1993. 7. Himes, R., Scharnott, M., and Hoyum, R., Fuel system modifications and boiler tuning to achieve early election compliance on a 372-MWe coal-fired tangential boiler, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997. 8. Wendt, J. O. L. et al., Reduction of sulfur trioxide and nitrogen oxides by secondary fuel injection, in Proc. 14th Int. Symp. Combustion, 897, 1973. 9. Folsom, B. A. et al., Field experience — reburn NOx control, presented at EPRIDOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997. 10. Garg, A., Specify better low-NOx burners for furnaces, Chem. Eng. Progr., 90(1), 46, 1994. 11. Sivy, J. L., Sarv, H., and Koslosky, J. V., NOx subsystem evaluation of B&W’s advanced coal-fired low emission boiler system at 100 Million BTU/hr, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997. 12. Bortz, S. J. et al., Ultra-low NOx rapid mix burner demonstration at Con Edison’s 59th Street Station, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997.
© 2002 by CRC Press LLC
9588ch17 frame Page 255 Wednesday, September 5, 2001 10:01 PM
13. Chen, W. et al., Deviation and application of a global SNCR model in maximizing NOx reduction, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symposium, Washington, D.C., August 25–29, 1997. 14. Ferrell, R., Controlling NOx emissions: a cooler alternative, Poll. Eng., 4, 50, 2000. 15. Reyes, B. E. and Cutshaw, T. R., SCONOx™ catalytic absorption system, Western Energy, 13, March 1999. 16. Haythornthwaite, S. et al., Stationary source NOx control using pulse-corona induced plasma, presented at EPRI-DOE-EPA Combined Utility Air Pollutant Control Symp., Washington, D.C., August 25–29, 1997.
© 2002 by CRC Press LLC
9588ch18 frame Page 257 Wednesday, September 5, 2001 10:02 PM
18
Control of SOx*
This chapter focuses primarily on sulfur dioxide emissions because they are the largest source of sulfur emissions and the primary contributor to acid rain. Other forms of sulfur emissions, including H2S, SO3, and sulfuric acid mist will be discussed. And, because some of the SO2 control technologies are directly applicable to HCl control, there will be brief discussion of HCl emissions as well. By far the largest source of sulfur emissions is from burning coal to generate electricity. An approximate distribution of sources that generate SO2 is presented in Figure 18.1. The declining trend in SO2 emissions, which is largely as a result of efforts to control SO2 as a source of acid rain, is plotted in Figure 18.2. Note in particular the sharp decline that occurred in 1995, which was a direct result of implementing the Phase I acid rain controls to comply with Title IV of the Clean Air Act Amendments. Sulfur occurs naturally in fuels. In coal, it is bound as iron pyrite, FeS2, mineral sulfates, elemental sulfur, and in organic compounds and mercaptans. High sulfur coals typically contain 2 to 5% sulfur. Low sulfur coals have less than 1% sulfur. Besides burning coal, sources of sulfur emissions include petroleum refining, oil and gas production, sulfur and sulfuric acid manufacturing, ore smelting, waste incineration, and petroleum coke calcining. Sulfur emissions as a source of air pollution can be avoided by using processes that remove sulfur from coal before it is burned. Washing coal removes some of the mineral sulfur, sometimes as much as 30 to 50% of sulfur in coal. But washing can be a relatively costly process, and research continues for froth flotation, magnetically enhanced washing, sonic enhancement, chemical oxidation, and selective agglomeration.
18.1 H2S CONTROL H2S is a common pollutant in oil and natural-gas processing facilities. Many facilities have sulfur recovery units that convert H2S to elemental sulfur using the Claus process. A simplified flow diagram for this process is illustrated in Figure 18.3. In this two-step process, a fraction of the H2S is burned to SO2. The combustion process must be carefully controlled to obtain the correct molar ratio of 2 moles of H2S for every mole SO2. The second step is to pass the mixture of H2S and SO2 over catalyst, where H2S is oxidized and SO2 is reduced to produce elemental sulfur by the reaction: 2 H 2S + SO2 → 2 H 2O + 3S
(18.1)
* Various sections of this chapter are based on Brown, C., Chem. Eng. Progr., 94(10), 63, 1998.
© 2002 by CRC Press LLC
9588ch18 frame Page 258 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.1 SO2 emission sources.
FIGURE 18.2 SO2 emission trend.
A 93 to 97% sulfur recovery can be obtained with the Claus process. However, the exhaust gas from the process, called tail gas, may contain small amounts of unreacted H2S, SO2, as well as carbon disulfide (CS2), carbonyl sulfide (COS), and sulfur vapor (S8). Some facilities simply incinerate the tail gas to convert the sulfur species to SO2 before exhausting to the atmosphere. But a variety of approaches are used to eliminate the SO2 emissions. The sulfur species may be hydrogenated to H2S, and then an H2S removal process treats the tail gas. Alternatively, the H2S and SO2 may be absorbed and a liquid phase reaction used to produce sulfur. Another alternative is to use an SO2 removal system for the SO2 in the tail gas.
© 2002 by CRC Press LLC
9588ch18 frame Page 259 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.3 Oil and gas processing sulfur recovery units.
18.2 SO2 (AND HCL) REMOVAL A variety of processes are available for control systems to treat SO2 and HCl emissions.1,2 Selection of the best process for each facility must, of course, include a traditional assessment of capital vs. operating costs. Additional considerations include operability, maintainability, plus site-specific preferences for the handling of slurries, aqueous solutions, and dry powder. SO2 control processes are used for coal-fired industrial boilers, coke calciners, and catalyst regenerators. SO2 and HCl controls are required for hazardous and municipal solid waste combustors. HCl control is used for aluminum furnaces fluxed with chlorine and regenerators for chlorinated solvent drums. Flue Gas Desulfurization (FGD) is well known to the coal-fired electric utility industry. Many facilities in that industry use wet limestone scrubbers that have a relatively high capital cost in order to utilize inexpensive limestone reagent, although other systems sometimes are used. Smaller, industrial-scale facilities typically use more expensive reagents in systems with lower equipment costs.
18.2.1 REAGENTS Reagent selection is a key decision that affects both process design and operating cost. Common reagents and approximate reagent costs are listed in Table 18.1. 18.2.1.1 Calcium-Based Reactions Limestone is an inexpensive rock that is quarried and crushed. It can be used directly as a reagent either in an aqueous slurry or by injection into a furnace where the heat decarbonates the limestone. Quicklime is produced by calcining limestone, so quicklime is more expensive than limestone because of the high energy requirement for calcination. CaCO3 + heat → CaO + CO2
© 2002 by CRC Press LLC
(18.2)
9588ch18 frame Page 260 Wednesday, September 5, 2001 10:02 PM
TABLE 18.1 Reagent Chemicals Common Name or Mineral Limestone Lime, quicklime Lime, slaked lime, hydrated lime Soda ash Caustic soda Nahcolitee Tronaf
Chemical
Formula
Cost ($/ton)
Calcium carbonate Calcium oxide Calcium hydroxide Sodium carbonate Sodium hydroxide Sodium bicarbonate Sodium sesquicarbonate
CaCO3 CaO Ca(OH)2 Na2CO3 NaOH NaHCO3 NaHCO3 ·Na2CO3 ·2H2O
$25a $57b $70b $105c $200d $260c $65c
a
Delivered. Cost will be lower for very large quantities delivered by barge. Free on board, supplier’s plant. Many locations throughout the United States. c Free on board, Wyoming. d Freight equalized (to be competitive, supplier offers same freight as closer competitor). Based on dry weight of NaOH in 50% solution. e Nahcolite is naturally occurring sodium bicarbonate that contains impurities. Sodium bicarbonate can be refined to remove impurities. f Trona is naturally occurring sodium sesquicarbonate that contains impurities. Sodium sesquicarbonate can be refined to remove impurities. b
Slaking or hydrating quicklime produces more expensive slaked or hydrated lime: CaO + H 2O → Ca(OH)2
(18.3)
Wet limestone scrubbing produces calcium sulfite and calcium sulfate reaction products. Oxidation of sulfite to sulfate can be inhibited by adding emulsified sulfur, which forms the thiosulfite ion. Alternatively, oxidation can be enhanced by blowing air into the slurry in the reactor holding tank. CaCO3 + SO2 + 1 2 H 2O → CaSO3 ⋅ 1 2 H 2O + CO2
(18.4)
2CaSO3 ⋅ 1 2 H 2O + 3H 2O + O2 → 2CaSO4 ⋅ 2 H 2O
(18.5)
Wet lime scrubbing, lime spray drying, and hydrated lime processes also form a mixture of calcium sulfite and sulfate reaction products:
© 2002 by CRC Press LLC
Ca(OH)2 + SO2 → CaSO3 ⋅ 1 2 H 2O + 1 2 H 2O
(18.6)
Ca(OH)2 + SO2 + 1 2 O + H 2O → CaSO4 ⋅ 2 H 2O
(18.7)
9588ch18 frame Page 261 Wednesday, September 5, 2001 10:02 PM
18.2.1.2 Calcium-Based Reaction Products Calcium sulfite is the reaction product from the inhibited wet limestone scrubber process. It forms needle-like crystals that are hard to de-water because of their high surface area. It has no market value, and it has a chemical oxidation demand (COD) if ponded. It can be landfilled, but must be stabilized (typically with flyash) to improve load-bearing properties. On the other hand, calcium sulfate product from the forced oxidation process has some desirable features. It forms block-like crystals that are easy to de-water. Also, pure calcium sulfate is gypsum, which can be used to manufacture wallboard. The dry solid waste product from dry calcium-based systems typically contains about 75% calcium sulfite and 25% calcium sulfate. It can be landfilled, but any unreacted reagent in the waste product will result in a leachate with a high pH. 18.2.1.3 Sodium-Based Reactions Wet Sodium-Based Scrubbers — Either soda ash or caustic soda may be used as reagents. They produce a clear scrubber liquor solution with a high pH. The two reagents often are cost competitive with each other on a weight basis, although soda ash tends to be a little less expensive. Caustic soda and soda ash solutions can be used interchangeably in most scrubbers. Caustic soda typically is sold as a 50% solution with pricing on a dry ton NaOH basis. A separate solids storage silo, solids feeder, and dissolution vessel are required to prepare soda ash solution. The market price for caustic soda tends to fluctuate more than other reagents due to market demand. To be competitive, caustic suppliers frequently offer shipping “freight equalized.” This means they will offer the same freight cost as a closer competitor despite being further away. Soda ash is dissolved in water to make the scrubber liquor solution: Na 2CO3 (s) + H 2O → 2 Na + (aq ) + CO3= (aq ) + H 2O
(18.8)
CO3= (aq ) + H 2O ↔ HCO3− (aq ) + OH −
(18.9)
Caustic soda typically is sold as a 50% solution, which eliminates the need for solids handling equipment. NaOH (s) + H 2O → Na + (aq ) + OH − + H 2O
(18.10)
The first step in alkaline scrubbers is absorption of SO2 into the aqueous solution. The alkalinity keeps the following equilibrium reactions progressing to the right, which prevents buildup of sulfurous acid from limiting the solubility of gaseous SO2: SO2 (g) + H 2O ↔ H 2SO3 (aq )
© 2002 by CRC Press LLC
(18.11)
9588ch18 frame Page 262 Wednesday, September 5, 2001 10:02 PM
Sulfurous acid dissociates to form bisulfite or sulfite, depending on the pH: H 2SO3 (aq ) ↔ HSO3− + H + ↔ SO3= + 2 H +
(18.12)
Therefore, the overall reactions with SO2 produce a mixture of sodium sulfite, sodium sulfate, and sodium bisulfite. The exact proportions of the sulfur species depend on the pH and degree of oxidation. The simplified overall reactions are 2 Na + + 2OH − + SO2 → Na 2SO3 (aq ) + H 2O
(18.13)
2 Na + + 2OH − + SO2 + 1 2 O2 → Na 2SO 4 (aq ) + H 2O
(18.14)
Na + + OH − + SO2 → NaHSO3 (aq )
(18.15)
pH is an important variable affecting the solubility of SO2 gas as well as reagent consumption. It takes two moles of sodium to remove one mole of SO2 as sodium sulfite or sulfate, but only one mole of sodium to remove one mole of SO2 as sodium bisulfite. However, a signficantly higher scrubbing liquor flow rate may be required to overcome the lower equilibrium concentration of total dissolved sulfur species at the lower pH where bisulfite is predominant. Also, if aeration is required to remove the chemical oxidation demand of sulfite and bisulfite in discharged wastewater, the final waste product is sodium sulfate, which requires two moles of sodium despite the pH. Dry Sodium-Based Systems — When exposed to heat, dry sodium bicarbonate decomposes to produce dry, high-surface-area soda ash. The soda ash in turn reacts with SO2. This can be achieved at moderate temperatures of 300 to 600°F, which is in the range of typical exhaust temperatures for many processes. 2 NaHCO3 + heat → Na 2CO3 + CO2 + H 2O
(18.16)
Na 2CO3 + SO2 → Na 2SO3 + CO2
(18.17)
Sodium bicarbonate may be purchased as a refined mineral, or as nahcolite, a naturally occurring mineral. Trona, which is mined as naturally occurring sodium sesquicarbonate, also can be used as a dry reagent. Its composition, shown in Table 18.1, is half sodium bicarbonate and half sodium carbonate. 18.2.1.4 Sodium-Based Reaction Products Sodium-based processes produce sodium bisulfite (NaHSO3), sodium sulfite (Na2SO3), and sodium sulfate (Na2SO4). These sodium salts are water soluble, which
© 2002 by CRC Press LLC
9588ch18 frame Page 263 Wednesday, September 5, 2001 10:02 PM
may create a disposal problem in some locations. The liquid waste from these wet scrubber systems cannot be discharged to fresh receiving waters. However, in locations near the ocean, wastewater disposal from wet systems is simplified because the wastewater can be discharged directly after pH adjustment and aeration. Because they are water soluble, dry reaction products from sodium-based powder injection systems produce leachate with high dissolved solids content.
18.2.2 CAPITAL
VS.
OPERATING COSTS
The classic tradeoff of capital vs. operating costs requires a good estimate of total installed cost for the system. Capital cost comparisons have been published for large, coal-fired power plants. However, these estimates may not scale down accurately for smaller industrial-scale systems. Industrial systems cover a wide range of sizes, and a traditional capital cost estimate should be developed during process selection. 18.2.2.1 Operating Costs The major operating cost is the reagent, which can be estimated for a wide range of system sizes in terms of dollars per ton SO2 and HCl removed. Power and waste product disposal also are significant operating costs that depend upon the process. The wet limestone scrubber, reagent, and power and waste product costs contribute about 33% each to the total operating cost. For the lime spray dryer or circulating lime systems, each of these components contributes approximately 60%, 15%, and 25%, respectively, to the operating costs. Also, operating labor and maintenance costs should be included if significant differences between processes can be estimated. The quantity of reagent added to the process is quantified in terms of the reagent ratio. This is defined as the ratio of the amount of reagent added to the stoichiometric amount of reagent required to react with the pollutants in the gas stream. Calcium Reagent Ratio =
(18.18)
moles Calcium added moles Ca ++ required by stoichiometry to remove 100% SO2 & HCl in gas stream
Note that this definition of reagent ratio is used by the dry and semi-dry acid gas scrubbing industry. It is different from the usual definition of reagent ratio used for wet limestone scrubbers, which is the ratio of moles calcium added per mole SO2 removed. To be consistent, reagent ratio in this chapter is based on moles pollutant in the incoming gas stream. Sodium Reagent Ratio = moles Na + added moles Na required by stoichiometry to remove 100% SO2 & HCl in gas stream +
© 2002 by CRC Press LLC
(18.19)
9588ch18 frame Page 264 Wednesday, September 5, 2001 10:02 PM
The reagent cost per ton of pollutant removed is $ mole Ca ++ or Na + required mole reagent = reagent ratio × × ton pollutant remove mole pollutant mole Ca ++ or Na + × ×
MWreagent MWpollutant
×
% reagent purity 100%
(18.20)
100% $reagent + freight × % pollutant removal ton reagent
18.2.3 SO2 REMOVAL PROCESSES Several commercially available and demonstrated processes for SO2 removal are summarized in Table 18.2 and are discussed further below. 18.2.3.1 Wet Limestone The process flow sheet for the wet limestone scrubbing process is shown in Figure 18.4. Equipment typically includes limestone crusher, storage silo, corrosion resistant absorber tower with mist eliminator, holding tank, slurry pumps, settler, vacuum filter, corrosion resistant ductwork, induced draft (ID) fan, and reheat or corrosion resistant stack. Additional blowers are required for the forced oxidation process. Particulate removal is typically done upstream by electrostatic precipitator or baghouse, but can be done downstream or as an integral part of the absorber. For example, a venturi scrubber for particulate control could double as the absorber when limestone slurry is used as the liquid. Wet limestone scrubbing is the workhorse process for coal-fired electric utility power plants. The high capital cost and the cost of operating and maintaining a complex system is offset by the low cost of limestone used to remove very large quantities of SO2. Originally, wet limestone scrubbers were difficult to operate because they were plagued by scaling problems. Partial oxidation of calcium sulfite to calcium sulfate causes sulfate crystals to build up on vessels, pipe walls, and appurtenances. This problem has been largely solved with the development of inhibited oxidation and forced oxidation technologies. Today, wet limestone scrubbers are much more reliable. Single absorbers are considered for a boiler unit at significant cost savings over multiple absorbers. Inhibited oxidation uses emulsified sulfur as an additive to produce the thiosulfate ion, which inhibits the oxidation of sulfite to sulfate. S + SO3= → S2O3=
(18.21)
Thiosulfate stays in solution and is recycled back to the absorber tower. The reaction product of the inhibited oxidation process is calcium sulfite. In the forced oxidation process, air is injected into the scrubber liquor to oxidize all of the sulfite to sulfate. This produces a large amount of seed crystals. As calcium © 2002 by CRC Press LLC
9588ch18 frame Page 265 Wednesday, September 5, 2001 10:02 PM
TABLE 18.2 Summary of Common Processes for Acid Gas Control Capital Cost
Reagent Cost
Process
Efficiency
Complexity
Wet limestone
High
High
Low
High
Wet soda ash/caustic
High
Moderate
High
Moderate
Lime spray dryer
Moderate
Moderate
Moderate
Moderate
Circulating lime reactor
Moderate to high
Moderate
Moderate
Moderate
Sodium bicarbonate/trona injection
Moderate
Low
High
Low
Comments Low reagent cost offsets high cost of operation and maintenance in very large systems. No slurry or solids handling. Very effective for smaller systems. Mature technology widely used for industrial applications. Subject to deposits accumulation during upset conditions. High solids circulation rate prevents deposits accumulation, enabling slightly higher reactivity or lower reagent cost than lime spray dryer. Lower cost of trona an advantage in HCl applications, but mostly offset by lower reactivity in SO2 applications.
sulfate precipitates, the crystals grow instead of forming scale. The byproduct of forced oxidation is calcium sulfate. The disadvantage of forced oxidation is the equipment and operating cost associated with blowers for air injection. SO2 and HCl removal efficiencies greater than 95% are attainable with wet limestone scrubbers using a reagent ratio of about 1.1. The performance is a function of the absorber configuration, liquid surface area for gas–liquid contact in the absorber, and slurry alkalinity. 18.2.3.2 Wet Soda Ash or Caustic Soda A simplified process flow sheet for a wet soda ash or caustic soda scrubber is shown in Figure 18.5. Equipment includes soda ash storage silo or caustic tank, corrosion © 2002 by CRC Press LLC
9588ch18 frame Page 266 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.4 Simplified wet limestone process flow diagram. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
resistant absorber with mist eliminator, holding tank, recirculation pumps, corrosion resistant ductwork, ID fan, and reheat or corrosion resistant stack. Particulate removal is typically done upstream of the absorption tower. Wet soda ash or caustic scrubbing is simpler than wet limestone scrubbing, since the reagent and the waste products are water soluble. There are no slurries or solid waste products to handle. At the same time, very high acid gas removal efficiency can be obtained. A common application for wet soda ash or caustic scrubbing is catalyst regeneration for fluid catalytic crackers in the refinery industry. One disadvantage of this process is the relatively high reagent cost, which is tolerable only for smaller systems. Also, the use of aqueous solutions instead of dry powders may be considered a disadvantage by some people, although others dislike handling powders so much that this is considered an advantage. A potential problem that can occur if SO3 is present when saturating the gas stream with water is the formation of submicron sulfuric acid mist. Once formed, submicron acid mist can pass through the scrubber and pose a difficult particulate collection or emission problem. Some midsize soda ash/caustic systems have been installed because they were simple and effective. However, they may have reagent costs that are higher than necessary. It is possible to reduce reagent cost signficantly by retrofitting lime treatment. Calcium hydroxide regenerates the sodium ion by ion exchange. Some © 2002 by CRC Press LLC
9588ch18 frame Page 267 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.5 Soda ash wet scrubber. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
additional equipment is required, including a lime storage silo, solids feeder, slaker, contact tank, pump, settler, and vacuum filter. This modified system is called “dual alkali” because both sodium- and calcium-based materials are used. 18.2.3.3 Lime Spray Drying The simplified lime spray dryer process flow sheet is shown in Figure 18.6. Widespread use has resulted in spray drying as a mature, developed technology for smaller and low-sulfur coal-fired boilers and for solid waste incinerators. Equipment includes carbon steel spray dryer vessel, rotary atomizer or two-fluid abrasion resistant nozzles requiring compressed air, lime storage silo, solids feeder, slaker, mix tank, slurry pumps, particulate collector, carbon steel ductwork, ID fan, stack, optional recycle mix tank and slurry pumps, and optional reheat. Spray drying with slaked lime slurry is relatively simple compared to a wet scrubber. Carbon steel vessels and ductwork can be used because the flue gas is kept above its saturation temperature. However, the process does require slaking and slurry handling equipment, plus careful control of operating conditions. SO2 removal performance is enhanced by the presence of surface moisture on the solid lime particles, but excess moisture can result in accumulation of deposits in the spray dryer vessel. The optimum temperature is maintained by control of the approach-to-adiabatic saturation (approach). This is the difference between the spray dryer exit temperature and the adiabatic saturation temperature. For air/water systems, the adiabatic saturation temperature can be estimated by measuring the wet bulb temperature. © 2002 by CRC Press LLC
9588ch18 frame Page 268 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.6 Simplified spray dryer flow diagram. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
Operating conditions have a marked effect on SO2 removal performance. The approach temperature and reagent ratio are the two major factors. Other variables include SO2 concentration and inlet gas temperature. The use of a baghouse instead of an electrostatic precipitator can enhance SO2 removal performance by forcing intimate contact between the gas stream and unreacted reagent in the dust cake. SO2 removal efficiency of 90% is attainable with a lime spray dryer under good operating conditions. Typical good operating conditions to achieve this level of performance require a reagent ratio of 1.3 at an approach of 20°F. Very high inlet temperature or high inlet SO2 concentration will reduce the level of performance. Performance is strongly affected by both approach temperature and reagent ratio at ratios below about 2.0 moles Ca/mole SO2. Increasing the reagent ratio above this level has a diminishing effect on improving performance. Calcium chloride plays a major role in selecting the desired approach temperature. It is a deliquescent salt, which means that it absorbs moisture then dissolves in the absorbed moisture. Spray dryer solids that contain calcium chloride will be sticky when cool. While this improves acid gas removal performance, it can lead to accumulation of deposits. To avoid this problem, municipal solid waste incinerator systems that scrub both SO2 and HCl operate at an approach of 50 to 100°F above adiabatic saturation, while spray dryers for coal-fired boilers typically operate at an approach of 20 to 50°F. Small changes in flue gas chloride content have a pronounced effect on SO2 removal performance. A change in residual chloride content in coal from 0.05 to 0.25% can increase SO2 removal performance by 8 to 10 percentage points in a coal-fired power plant application.3 © 2002 by CRC Press LLC
9588ch18 frame Page 269 Wednesday, September 5, 2001 10:02 PM
HCl is removed in a spray dryer more readily than SO2. Therefore, SO2 removal usually is the limiting criteria for performance. The reagent requirement should consider HCl to be completely removed first, followed by the quantity required for SO2 removal. It is possible to run a spray dryer system using soda ash solution instead of slaked lime slurry as the reagent. Soda ash precludes the need for a slaker and slurry handling. Deposit buildup can still be an issue, however, and soda ash is significantly more expensive than lime. Therefore, this option in not often used since the technology provides only moderate performance. The expense of soda ash is accepted in wet scrubbers that are capable of high SO2 removal efficiency. 18.2.3.4 Circulating Lime Reactor Simplified process flow sheets for circulating lime reactors using quicklime and hydrated lime are shown in Figures 18.7 and 18.8, respectively. Equipment includes a carbon steel reactor, lime storage silo, particulate precollector, final particulate collector, carbon steel ductwork, ID fan, and stack. Either a hydrator or a slaker is required to use less expensive quicklime reagent. Hydrated lime can be used with less equipment, but a hydrator or slaker usually can pay for itself quickly even in small systems. The circulating lime reactor process is similar to the spray drying process, but has one significant difference: in this system a much larger quantity of solids can be recycled from the particulate collectors to the reactor because the solids recycle rate is not limited by the water balance and maximum pumpable slurry concentration. The larger solids recycle produces two advantages. First, it enhances reagent utilization by providing additional gas–solid contact time with additional passes of solids through the reactor. Second, the recycled solids provide surface area to absorb
FIGURE 18.7 Simplified hydrated lime reactor flow diagram: lime slurry. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
© 2002 by CRC Press LLC
9588ch18 frame Page 270 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.8 Hydrated lime reactor flow diagram: humidification and hydrated lime. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
moisture and scour the walls of the reactor vessel. The second advantage is the more significant of the two. It allows the reactor to operate at a lower approach temperature than a spray dryer, without experiencing deposits accumulation. Results show that, under otherwise identical conditions, 90% SO2 removal can be obtained at a reagent ratio of 1.2 and approach of 12°F with a circulating lime reactor.4 This compares to a reagent ratio of 1.3 at an approach of 18°F for a spray dryer. At the same operating conditions, there is little difference in the performance between the circulating lime reactor and the spray dryer with optional solids recycle in the slurry.5 However, high removal efficiency performance levels of 98% can be achieved with the proper combination of high reagent ratio (greater than 1.5), low approach temperature, and sufficient solids chloride content.6 Cooling is required to promote the reaction between lime and SO2 in the presence of surface moisture on lime particles. Vendors of circulating lime reactor systems use different methods of cooling, including prehumidification, humidification in the reactor, slurry spray (with quicklime reagent), and heat exchange. Air dilution can also be used, although it increases the gas flow and requires a larger baghouse and ID fan. Prehumidification of acid gases must be done in a properly designed humidification chamber to avoid corrosion. Two-fluid nozzles are used to atomize the water spray. In larger systems, the cost of compressed air is significant. Humidification within the reactor vessel avoids the corrosion problem because the alkalinity of the reagent neutralizes any acid. Simpler water nozzles can be used because the solids absorb moisture and a very fine spray is not required. Both prehumidification and humidification systems use hydrated lime as the reagent. Hydrated lime powder can be produced from quicklime using a hydrator. Small users may purchase hydrated lime, which is more expensive than quicklime. © 2002 by CRC Press LLC
9588ch18 frame Page 271 Wednesday, September 5, 2001 10:02 PM
Slaked lime slurry can be used to humidify and inject lime in one step, but requires a slaker, slurry pumps, and an abrasion-resistant slurry spray nozzle. It also requires compressed air to atomize the slurry. Cooling with an air-to-gas heat exchanger avoids the use of water, but adds the cost of the exchanger. This is an attractive approach in applications where water is scarce or there is a use for the recovered low-grade heat. Because the circulating lime process can operate at a lower approach temperature than a lime spray dryer, the circulating lime process has slightly better reagent utilization. This gives a reagent cost advantage to the circulating lime process when quicklime is used. 18.2.3.5 Sodium Bicarbonate/Sodium Sesquicarbonate Injection A process flow sheet for the sodium bicarbonate process is shown in Figure 18.9. The basic flowsheet for sodium sesquicarbonate injection is the same, although the reagent reactivity and costs are different. Equipment includes reagent storage, solids feeder, blower for pneumatic injection, particulate collector, carbon steel ductwork, ID fan, and stack. This is a very simple system that has minimal operation and maintenance requirements. Sodium bicarbonate decarbonates in the temperature range of 300 to 500°F. This is a typical range for exhaust gases from combustion systems with air heaters or heat recovery. The decarbonation process causes particles to “popcorn,” creating high surface area reagent and exposing fresh reagent that was covered by reaction products. While the decarbonated reagent is Na2CO3, injecting less expensive Na2CO3 does not work well because the popcorn effect is important to reactivity.
FIGURE 18.9 Sodium bicarbonate flow diagram. (Reproduced with permission of the American Institute of Chemical Engineers. Copyright © 1998 AIChE. All rights reserved.)
© 2002 by CRC Press LLC
9588ch18 frame Page 272 Wednesday, September 5, 2001 10:02 PM
Ninety percent SO2 removal performance can be achieved with sodium bicarbonate at a reagent ratio of approximately 1.2 moles Na/mole SO2.7 Trona, which is mined as naturally occurring sodium sesquicarbonate, is an alternate reagent. Its use can reduce reagent cost, particularly in HCl applications. In SO2 applications, the performance of trona is lower than sodium bicarbonate, which reduces its cost advantage. To achieve 90% SO2 removal performance with trona, a relatively high reagent ratio of about 1.5 to 1.9 moles Na/mole SO2 is required.7,8 In HCl applications, however, the performance of trona is nearly equal to sodium bicarbonate at the same reagent ratio.8 The estimated reagent ratio to achieve 90% HCl removal using trona is approximately 1.2 moles Na/mole HCl. A disadvantage of sodium bicarbonate injection for SO2 applications is the potential for formation of a brown, NO2 plume. A NO2 plume can develop under certain combinations of SO2, NO, moisture, and temperature. The necessary combination is typical of flue gas from coal-fired power plants. Overall NOx removal of about 20% can be obtained with the process, but some NO is oxidized to NO2, resulting in increased NO2 concentrations despite overall NOx removal. NO2 emissions can be controlled with additives such as ammonia, ammonium bicarbonate, or urea.7 The plume problem does not arise at elevated temperatures (>400°F), at high moisture concentrations, or in HCl removal applications where SO2 is not present. The low cost, simple sodium bicarbonate system comes with a very high reagent cost of $260/ton plus freight from Wyoming. That is the only location in the U.S. where sodium bicarbonate is mined commercially. Freight makes up a substantial portion of the reagent cost and must be included in a site-specific cost analysis. The high reagent cost makes economic sense only when the quantity of pollutant is low. Trona, at $65/ton plus freight from Wyoming, is much less expensive than sodium bicarbonate. Since the reactivity for HCl removal is almost the same as sodium bicarbonate, the cost advantage for HCl removal is huge. Much of the cost advantage is lost in SO2 removal applications, however, due to lower reactivity with SO2. A reagent ratio of 1.9 may be required to achieve 90% removal in typical SO2 applications. 18.2.3.6 Other SO2 Removal Processes Several other processes, such as duct injection, duct spray drying, furnace injection, economizer injection, ADVAnced siliCATE (ADVACATE), E-SOx, and HYbrid Pollution Abatement System (HYPAS) have been piloted or developed, but are not widely used for industrial systems. However, a basic understanding of the reagents and reaction mechanisms and the inherent advantages and disadvantages of the processes described above will enable one to evaluate modifications of these processes as well as other new processes that may be offered.
18.2.4 EXAMPLE EVALUATION An industrial facility has a 100,000 acfm exhaust gas stream at 400°F that contains 1000 ppm SO2 and 200 ppm HCl. Each pollutant requires 90% removal efficiency. This facility wants a 5-year payback on any capital investment that reduces operating
© 2002 by CRC Press LLC
9588ch18 frame Page 273 Wednesday, September 5, 2001 10:02 PM
costs, using a 10% interest rate. The facility is located next to the ocean, so dissolved sodium salts could be discharged after aeration. The operators have expressed a dislike for slurry handling systems. Which system is recommended? An evaluation of capital and operating costs, summarized in Table 18.3, shows that all of the sodium-based reagents have very high reagent costs for this application. The cost savings of calcium-based systems are significantly greater that the extra cost of landfilling the waste product. Also, the high capital cost of a wet limestone scrubber makes it expensive to recover the small savings in reagent cost. Given the choice between a lime spray dryer and a circulating lime reactor at the same capital cost, a small savings in reagent requirement for the circulating lime reactor, and the operators’ preference for avoiding slurry handling, then a circulating lime system that uses water instead of slurry for humidification is recommended for this hypothetical case.
18.3 SO3 AND SULFURIC ACID 18.3.1 SO3
AND
H2SO4 FORMATION
An interesting aspect of sulfur oxide emissions is the oxidation of a small fraction of SO2 to SO3. Oxidation is promoted by the presence of metals in contact with the flue gas that catalyze the reaction. Some catalysis may occur from iron on boiler tubes. Fly ash from coal combustion may contain metals that catalyze the oxidation of SO2. Petroleum coke typically has a relatively high vanadium content, which comes from crude oil, so petroleum coke combustion and calcining can have a high oxidation rate. Also, fluid catalytic cracker regenerator flue gas contains entrained catalyst. SO3 combines readily with water vapor in the temperature range of 400 to 900°F, producing sulfuric acid vapor. The equilibrium relationship between SO3, H2O, and H2SO4 is given by Gmitro and Vermeulen:9 298 81016.1 9643.04 ln K p = −6.71464 ln − − + 14.74965 T T2 T
(18.22)
− 0.009458 T + 0.00000219062 T 2 where Kp =
pSO3 p H2O p H2SO4
, atm
T = temperature, °K Using this equilibrium relationship, the fraction of SO3 converted to H2SO4 as a function of temperature and water vapor concentration in flue gas is plotted in Figure 18.10. Condensed sulfuric acid is extremely corrosive, and, as noted in the discussion of wet limestone scrubbing, requires the use of corrosion-resistant materials where © 2002 by CRC Press LLC
System Total installed cost Capital recovery cost Reagent ratio for SO2 Reagent ratio for HCl Reagent use (tons/yr) Reagent cost Power cost Landfill cost Total annual cost
© 2002 by CRC Press LLC
Wet Limestone Scrubber
Lime Spray Dryer
Circulating Lime Reactor
Soda Ash Scrubber
Caustic Scrubber
Sodium Bicarbonate Injection
Trona Injection
$7,000,000 $1,847,000 1.0 1.0 4600 $115,000 $115,000 $115,000 $2,192,000
$4,000,000 $1,055,000 1.3 1.0 3280 $187,000 $47,000 $78,000 $1,367,000
$4,000,000 $1,055,000 1.2 1.0 3040 $174,000 $47,000 $78,000 $1,354,000
$6,000,000 $1,583,000 1.0 1.0 4880 $512,000 $115,000 $0 $2,210,000
$6,000,000 $1,583,000 1.0 1.0 3680 $736,000 $115,000 $0 $2,434,000
$2,500,000 $659,000 1.2 1.2 9270 $2,967,000 $47,000 $0 $3,673,000
$2,500,000 $659,000 1.7 1.2 11420 $1,427,000 $47,000 $0 $2,133,000
9588ch18 frame Page 274 Wednesday, September 5, 2001 10:02 PM
TABLE 18.3 Example Evaluation
9588ch18 frame Page 275 Wednesday, September 5, 2001 10:02 PM
FIGURE 18.10 SO3/H2SO4 equilibrium.
the flue gas temperature is below the acid dew point. When the temperature is below the acid dew point, sulfuric acid vapor condenses into liquid aerosol droplets. Haase and Borgmann10 proposed a simple correlation for the acid dew point based on experimental data: Tdp, C = 255 + 27.6 log PH2O + 18.7 log PSO3
(18.23)
where Tdp,C = sulfuric acid dew point, °C P = partial pressure, atmospheres Although useful because of its simplicity, it does not predict dew point accurately at high temperatures. Other correlations do not show a linear relation between dew point and the logarithm of the SO3 partial pressure. Verhoff and Banchero11 proposed another equation for sulfuric acid dew point: 1 Tdp, K
= 0.002276 − 0.00002943 ln PH2O − 0.0000858 ln PSO3
(
)(
+ 0.0000062 ln PH2O ln PSO3 where Tdp,K = sulfuric acid dew point, °K P = partial pressure, mm Hg
© 2002 by CRC Press LLC
)
(18.24)
9588ch18 frame Page 276 Wednesday, September 5, 2001 10:02 PM
Okkes and Badger12 proposed a correlation that is based on the simplicity of the correlation of Haase and Borgmann,10 but is adjusted to curve-fit data:
(
Ta , C = 203.25 + 27.6 log PH2O + 10.83 log PSO3 + 1.06 log PSO3 +8
)
2.19
(18.25)
where Ta,C = sulfuric acid dew point, °C P = partial pressure, atmospheres One problem with using the acid dew point correlations is determining the partial pressure of SO3. The oxidation of SO2 to SO3 is affected by a number of variables, including oxygen and SO2 concentrations, temperature, and the presence of catalysts that may be in entrained particulate or on metal boiler tubes. Neglecting the influence of catalysts, thermodynamic equilibrium may be used to estimate the SO3 concentration at temperatures above 1000°C where kinetics do not hinder the reaction rate by using the relationship: Kp =
PSO3
( )
(18.26)
0.5
PSO2 PO2
The equilibrium constant, Kp, may be calculated from: ln K p =
12120 3.1 (18.27) 1 − (0.000942 T) + 7.02 × 10 −8 T 2 − 1.08 × 10 −5 T ln T − T T
(
) (
)
where T = temperature, °K The SO3 concentration in cooled flue gases can be estimated using the relationship in Equation 18.25 at a temperature of 1000°C by assuming slow kinetics “freezes” the concentration at that value. An alternative to calculating acid dew point from equations, assumptions, and empirical correlations is to measure it with a commercially available acid dew point analyzer. Typical coal-fired boilers have acid dew points of approximately 225 to 275°F. Formation of sulfuric acid mist presents another unique problem to wet SO2 absorbers. Submicron mist can form immediately at the entrance of a wet absorber as the flue gas is saturated with water and before gas phase SO3 and H2SO4 diffuses to large droplets of absorber liquor solution. Once the submicron mist is formed, it is difficult to remove with a wet scrubber because the mechanisms of interaction and interception are weak for removing submicron particulate (droplets of sulfuric acid mist). This can result in significant sulfuric acid mist emissions, which can form a visible plume. This has been an aggravating problem for coal-fired utility boilers that retrofitted wet SO2 absorbers downstream of existing electrostatic precipitators to meet SO2 emission control requirements. While succeeding in removing substantial amounts of SO2, some of them went from clear stacks to a stack that emitted a bluish-gray haze.13 © 2002 by CRC Press LLC
9588ch18 frame Page 277 Wednesday, September 5, 2001 10:02 PM
18.3.2 TOXIC RELEASE INVENTORY Until recent years, sulfuric acid mist generated by combustion processes was sometimes overlooked and unreported for the annual SARA 313 Toxic Release Inventory. Also until recently, coal-fired utilities were exempt from SARA reporting. But when reported, the quantity of sulfuric acid mist generated by combustion processes is a very large number. Interestingly, the reporting requirements for sulfuric acid mist exclude SO3, but include H2SO4 in both the vapor and liquid droplet forms.14 This is one of those many oddities that can be found in the regulations for reporting. But it means that knowing the conversion of SO3 to H2SO4 is important for accurate reporting.
REFERENCES 1. Brown, C., Pick the best acid-gas emission controls for your plant, Chem. Eng. Progr., 94(10), 63, 1998. 2. Lunt, R. R. and Cunic, J. D., Profiles in Flue Gas Desulfurization, AIChE, New York, 2000. 3. Brown, C. A. et al., Results from the TVA 10-MW spray dryer/ESP evaluation., presented at EPA/EPRI First Combined FGD and Dry SO2 Control Symp., St. Louis, MO, October 25–28, 1988. 4. Hedenhag, J. G. and Goss, W. L., Gas suspension absorption: A new approach in FGD systems for boilers and incinerators, presented at the 88th Annual Meeting Air & Waste Management Assoc., San Antonio, TX, June 18–23, 1995. 5. Lepovitz., L. R. et al., Results of the recent testing of the 10-MW gas suspension absorption flue gas desulfurization technology, presented at 88th Annual Meeting of the Air & Waste Management Assoc., San Antonio, TX, June 18–23, 1995. 6. Moore, S. R., Toher, J. G., and Sauer, H., Update of the EEC/Lurgi high efficiency, dry circulating fluid bed scrubber experience, presented at EPRI Conf. on Improved Technology for Fossil Fueled Power Plants — New and Retrofit Application, Washington, D.C., March 1, 1993. 7. Bland, V. V. and Martin, C. E., Full-scale demonstration of additives for NO2 reduction with dry sodium desulfurization, Electric Power Research Institute, Palo Alto, CA, EPRI GS-6852, 1990. 8. Baldwin, A. B. Trona use in dry sodium injection for acid gas removal, presented at Society of Mining Engineers, Denver, CO, February 1995. 9. Gmitro, J. I. and Vermeulen, T., Vapor-liquid equilibria for aqueous sulfuric acid, AIChE, 10, 740, 1964. 10. Haase, R. and Borgmann, H. W., Korrosion, 15, 47, January 1981. 11. Verhoff, F. H. and Banchero, J. T., Predicting dew points of flue gases, Chem. Eng. Progr., 70(8), 71, 1974. 12. Okkes, A. G. and Badger, B. V., Get acid dew point of flue gas, Hydrocarbon Proc., 66(7), 53, 1987. 13. Jones, C. and Ellison, W., SO3 tinges stack gas from scrubbed coal-fired units, Power, 142(4), 73, 1998. 14. Emergency Planning and Community Right-To-Know Act — Section 313: Guidance for Reporting Sulfuric Acid, U.S. EPA, Office of Pollution Prevention and Toxics, Washington, D.C., EPA-745-R-97-007, 1998.
© 2002 by CRC Press LLC
9588ch19 frame Page 279 Wednesday, September 5, 2001 10:03 PM
19
Fundamentals of Particulate Control
To understand particulate control, one first must understand some fundamental concepts and properties of particulate. Figure 19.1 shows common terms associated with particulate material as a function of particle diameter. Particles of concern to air pollution are typically measured in microns (i.e., micrometers, or 1 × 10–6 m). Large or coarse particles are those considered to be well above 10 microns. Note for perspective that the diameter of a human hair is approximately 50 to 110 microns. Very small or fine particles are considered to be those less than one micron, or submicron. This size range includes smoke and fumes. Also notice that the size range considered “lung damaging dust” ranges from approximately 0.7 to 7 microns. Dust in this size range gets into lungs and is the most difficult dust to collect with particulate control equipment for reasons that will be discussed later in this chapter.
19.1 PARTICLE-SIZE DISTRIBUTION Particles frequently are described by their diameter. The amount of the particulate of a given diameter is very informative. But pay attention to the number distribution and the mass distribution. Table 19.1 illustrates the distinction. Given 100,000 particles of one micron diameter and assigning each particle a unit mass of one gives a total mass of 100,000 units. Adding 1,000 particles with a diameter of 10 microns, plus 10 particles with a diameter of 100 microns provides a size distribution consisting of one, 10, and 100 micron particles. There are 101,010 particles, of which 99% are one micron in diameter. Because the volume, and therefore the mass of each particle varies with the cube of the diameter, the mass of one-micron particles is only 9% are the total mass of all particles. Size distributions commonly are expressed in terms of the mass distribution. It is always best to be very clear whether the distribution is a mass or a number distribution. Sample particle size distribution data are listed in Table 19.2. Data are divided into six size bins, the first being zero to 2 microns, and the last being greater than 25 microns. Note that the last size bin is open ended. The mass fraction of particulate within each size range is provided. The next column gives the cumulative weight percent less than the top size listed in each size range. Cumulative size distributions are commonly plotted on probability paper. Probability paper is based upon the normal distribution, a bell shaped curve, with the highest density in the center and the lowest densities at each extreme. The x-axis on probability paper is different from logarithmic graph paper, where the highest density would be at the extreme top or right. The y-axis on probability paper may be either linear or logarithmic. The example data listed in Table 19.2 are plotted on
© 2002 by CRC Press LLC
9588ch19 frame Page 280 Wednesday, September 5, 2001 10:03 PM
FIGURE 19.1 Common particulate terms and size ranges.
TABLE 19.1 Number Fraction vs. Mass Fraction dj, m
Number
1 10 100 Total
100,000 1000 10 101,010
Number Fraction
Mass of Particle
Total Mass
1 1000 106
105 106 107 1.11 × 107
0.990000 0.009900 0.000099 1.0
TABLE 19.2 Sample Particle Size Distribution Data Size Range (m) 0–2 2–5 5–9 9–15 15–25 >25
© 2002 by CRC Press LLC
Mass Fraction in Size Range, (mj)
Cumulative % Less Than Top Size
0.005 0.195 0.400 0.300 0.080 0.020
0.5 20.0 60.0 90.0 98.0 100.0
Mass Fraction 0.009 0.090 0.900 1.0
9588ch19 frame Page 281 Wednesday, September 5, 2001 10:03 PM
FIGURE 19.2 Sample particle size distribution on linear-probability plot.
FIGURE 19.3 Sample particle size distribution on log-probability plot.
linear probability paper in Figure 19.2, and on log-probability paper in Figure 19.3. On probability paper with a linear y-axis, a normal distribution would plot as a straight line. On log-probability paper, a log normal distribution would plot as a
© 2002 by CRC Press LLC
9588ch19 frame Page 282 Wednesday, September 5, 2001 10:03 PM
FIGURE 19.4 Particle size bins plotted on linear graph paper.
straight line. The sample particle size distribution in Table 19.2 plots as a straight line on log-probability paper, so it is a log-normal distribution. This data can be plotted on linear graph paper giving the mass fraction in equal micron size range bins, which would show a skewed distribution as shown in Figure 19.4. The same distribution, but with the mass fraction bins plotted on a log scale, gives the distribution shown in Figure 19.5. The distribution produces a bellshaped curve when plotted on the log-scale, indicative of a log-normal distribution. When the same data are plotted as a cumulative distribution, i.e., as the total percentage less than the specified particle size, an S-shaped curve is produced. The curve for a log-normal distribution is skewed when plotted on linear graph paper,
FIGURE 19.5 Particle size bins plotted on semi-logarithmic graph paper.
© 2002 by CRC Press LLC
9588ch19 frame Page 283 Wednesday, September 5, 2001 10:03 PM
FIGURE 19.6 Sample cumulative size distribution on linear paper.
FIGURE 19.7 Sample cumulative size distribution on semi-logarithmic paper.
as shown in Figure 19.6. But when plotted on semi-logarithmic paper, the curve is symmetrical, as shown in Figure 19.7. Log-normal distributions are common for many particulate emission sources because a large amount of mass is concentrated in a very few large particles. While common, other distributions are certainly found. Bimodal distributions, those with a large mass of particles in two different size fractions, sometimes are found. They may be indicative of two different mechanisms for generating the particles. For example, larger particles in the distribution may have formed from a grinding process, while smaller particles may have formed from a condensation process.
© 2002 by CRC Press LLC
9588ch19 frame Page 284 Wednesday, September 5, 2001 10:03 PM
19.2 AERODYNAMIC DIAMETER The diameter of the particle is a common descriptor. But there are two diameters that are commonly used as descriptors: physical diameter and aerodynamic diameter. The physical diameter, of course, is the actual diameter of a spherical or nearly spherical particle. The aerodynamic diameter is the diameter of a spherical particle with the density of one gram per cubic centimeter that behaves aerodynamically in the same manner as the subject particle. That is, the actual particle and the spherical particle with density of 1 g/cm3 have the same momentum and drag characteristics. As a practical example, they have the same terminal settling velocity, which is an aerodynamic property. Remember that terminal settling velocity results from simple force balance between the force of gravity and resisting drag force.
19.3 CUNNINGHAM SLIP CORRECTION When airborne particles are so small that the particle size approaches the mean free path of gas molecules, less than 5 microns, drag on on the particles tends to be reduced. Drag is created as gas molecules impact a moving particle. But when the mean free path is approached, a moving particle will tend to “slip” between the gas molecules with less resistance. This phenomena is of importance to particulate collection devices and the term Cunningham slip correction factor will be found in many small particle correlations. The following empirical correlation for the Cunningham slip correction factor was developed by Davies:1 C′ = 1 + 2
λ dp
dp 1.257 + 0.4 exp −0.55 λ
(19.1)
where C′ = cunningham slip correction factor λ = mean free path, meters dp = particle diameter, microns The mean free path, λ, is given by: λ=
µ 0.499 ρg u m
where µ = gas viscosity, kg/m-s ρg = gas density, kg/m3 um = mean molecular speed, m/s The mean molecular speed, um, is given by:
© 2002 by CRC Press LLC
(19.2)
9588ch19 frame Page 285 Wednesday, September 5, 2001 10:03 PM
um =
8RT π MW
(19.3)
where MW = molecular weight of the gas R = universal gas constant, 8315 g m2/gmole-°K-s2 T = absolute temperature, °K By the ideal gas law, density is ρg =
m PMW = V RT
(19.4)
So the gas mean free path can also be expressed as: µ
λ= 0.499P
8MW π RT
(19.5)
where P = Pressure, Pa The Cunningham slip correction factor for air at 1.0 atm is plotted in Figure 19.8. It can be seen that the correction factor has a major effect when the particle diameter is less than 1 micron.
FIGURE 19.8 Cunningham slip correction factor for air at 1 atm.
© 2002 by CRC Press LLC
9588ch19 frame Page 286 Wednesday, September 5, 2001 10:03 PM
19.4 COLLECTION MECHANISMS 19.4.1 BASIC MECHANISMS: IMPACTION, INTERCEPTION, DIFFUSION Consider a particle in a gas stream moving toward or being carried toward a target. If the particle touches the target, it likely will stick to the target due to intersurface forces. The target may be a liquid droplet, as in the case of wet scrubbers, or a fiber, as in a fabric filter baghouse. Three mechanisms by which the particle touches the target are illustrated in Figure 19.9. Small, medium, and large size particles are depicted as being carried by the gas stream toward round targets. The gas flow streamlines are shown as diverging as they approach the target, then moving around the target. In each of these mechanisms, a large number of targets will increase the probability that a particle will touch a target. Therefore, having abundant targets enhances collection efficiency.
FIGURE 19.9 Basic particle collection mechanisms.
© 2002 by CRC Press LLC
9588ch19 frame Page 287 Wednesday, September 5, 2001 10:03 PM
19.4.1.1 Impaction In the mechanism called impaction, large particles moving toward the target have mass, and therefore momentum, which causes each particle to travel in a straight line toward the target. The particle leaves the streamline as the streamline bends to move around the target. The greater the mass of the particle, the more likely that it will travel in a straight line. Also, as the velocity difference between the particle and the target increases, the particle will have increased momentum and will be more likely to be carried into the target. The radius of curvature of the bend in the streamline has a very important effect on the probability that a particle will be carried into the target. The smaller the radius of curvature, the less likely that a particle will follow the streamline. Therefore, small targets are more likely to be impacted than large targets. 19.4.1.2 Interception Interception is the mechanism by which particles of roughly 0.1 to 1 micron diameter are carried by the gas streamline sufficiently close to the surface of the target that the particle touches the target. These particles have insufficient inertia to leave the gas streamline and are carried with the streamline. Some gas will flow very close to the particle. Interception is a relatively weak mechanism for particle collection compared to impaction and, as discussed in the next section, diffusion. It is coincidental that the path of the streamline and the particle happens to be close to the target. It is for this reason that particles in this size range are difficult to collect compared to larger and smaller particles. For the same reason, particles in this size range are not collected by natural cleaning mechanisms in nasal and tracheobronchial passages, and enter the lungs where they can lodge in the alveoli. 19.4.1.3 Diffusion Diffusion of extremely small, submicron particles is a result of Brownian motion. These particles are so small that the mass of the particles is very small and the number of collisions with air molecules is low. Therefore, random collisions with air molecules cause the particle to bounce around. They are moved from one gas streamline to the next by random motion. If sufficient time is allowed, and if the distance to the target is small, then diffusion can be an effective collection mechanism. This is why fabric filter baghouses can be effective for collecting submicron particles, and why it is difficult for wet venturi scrubbers to collect these particles.
19.4.2 OTHER MECHANISMS 19.4.2.1
Electrostatic Attraction
If particles acquire a charge and are placed in an electric field, the electrostatic force will move the particles across gas flow streamlines. Electrostatic forces on small
© 2002 by CRC Press LLC
9588ch19 frame Page 288 Wednesday, September 5, 2001 10:03 PM
particles can be quite large, making this a very effective mechanism for particle collection. This mechanism is utilized in electrostatic precipitators. 19.4.2.2 Gravity The force of gravity is sufficient to pull very large particles out of a gas stream. Some mechanical separators are designed to slow a gas stream to allow particles to settle. However, gravity is a weak mechanism for all but the heaviest particles. 19.4.2.3 Centrifugal Force Centrifugal force is the basis for cyclonic separation as a dusty gas is spun into a circle. Cyclones are discussed in Chapter 21. 19.4.2.4 Thermophoresis When a temperature gradient exists across a gas space, there will be a small temperature difference from one side of a particle to the other side. Gas molecules on the high-temperature side of the particle collide with the particle with more energy than gas molecules on the cooler side. This causes the particle to move slightly toward the cold side. Thermophoresis is a relatively weak mechanism for particle collection, but it can have a small effect on collection efficiency. 19.4.2.5 Diffusiophoresis Diffusiophoresis can be illustrated by considering the example of water vapor in a gas stream condensing on a cold target. As water vapor molecules are removed from the gas stream by condensation in the vicinity of the target, the concentration of water molecules, and hence the partial pressure of water vapor, is decreased. The concentration gradient causes water molecules from the bulk gas space move toward the cold target. The moving water vapor molecules collide with particles, causing them to be driven slightly toward the cold target. Again, this is a relatively weak mechanism that can have a small effect on particulate collection efficiency.
REFERENCE 1. Davies, C. N., Definitive equations for the fluid resistance of spheres, Proc. Phys. Soc., 57, 259, 1945.
© 2002 by CRC Press LLC
9588ch20 frame Page 289 Wednesday, September 5, 2001 10:06 PM
20
Hood and Ductwork Design
20.1 INTRODUCTION The design of hoods and ductwork is often a very important part of air-pollution control. Hoods and the air exhausted must be adequate to prevent escape of contaminants to the atmosphere. On the other hand, the air exhausted through a hood must usually be treated to remove the contaminant. Therefore, to keep capital and operating costs of control equipment to a minimum, no more air should be exhausted than necessary for complete capture. By designing the hood with the minimum openings necessary, the air quantity to be exhausted can often be decreased. When an exhaust system must exhaust gases from a number of points, it is important that the ductwork sizing and layout be carefully engineered for the proper flow and velocity in all branches, both for conveying velocity and pressure drop. It is axiomatic that the pressure drop through each branch at its design flow must be the same from its intake to the point of common junction. If it is not, the flow will redistribute itself in operation to create the same pressure drop in each branch. When handling abrasive dusts, duct wear can be quite severe. Situations are known to have occurred where ¼-in.-thick elbows have been worn through in 2 weeks time in poorly designed exhaust systems. Therefore, when handling abrasive dusts, the duct routing should be as simple and direct as possible. Bends, where necessary, should be gradual with long radii. Velocity should be kept as low as possible, consistent with keeping the dust particles in suspension. Where bends in the ductwork are necessary and rapid wear is encountered, designs can be developed which employ easily replaceable wear pads on the bends. These pads can be thick metal, made of wear-resistant steel, castings, hard-surfaced with special abrasionresistant alloys such as stellite, or have thick rubber-coated linings. A number of good reference sources are available for the design of hoods and ductwork and should be consulted before design of an elaborate dust-collecting network of ducts. Among the better general references recommended are: Dalla Valle,1 Hemeon,2 American Conference of Governmental Industrial Hygienists,3 ASHRAE Handbook,4 and Buonicore and Davis.5 A recent article by R. H. King6 describes the proper installation of fans for optimal system performance. A concise summary of exhaust system design was prepared by Brandt.7 While it is an excellent article on hood and duct design, it was written in 1945. Thus, it was written more from the standpoint of industrial ventilation rather than pollution control. The information presented is still accurate and useful. However, it must be understood that statements concerning control velocity
© 2002 by CRC Press LLC
9588ch20 frame Page 290 Wednesday, September 5, 2001 10:06 PM
which relate to capturing sufficient contaminants to prevent a worker health hazard, must now be interpreted as meaning capture of contaminants sufficient to prevent pollution of air. The principle in design of hoods and ducts is to choose a velocity that fits the situation. For both hoods and ducts, the velocity must be sufficient to overcome the pressure drop. For hoods, the material must be drawn up and into the duct. For ducts, the velocity must be sufficient to keep any particles suspended. Once the operating velocity is set, the flow is governed by the following law for volumetric flow. Q = AV
(20.1)
Here Q is the volumetric flow rate, V is the velocity chosen, and A is the required area of flow. Once a velocity is chosen for a hood, the area required to cover the source from which the pollutant must be removed determines the flow rate. The flow rate needed in a duct sets the area of the duct.
20.2 HOOD DESIGN The purpose of a hood is to collect contaminants from a workplace. Significant amounts of air are also drawn into the hood. The air flow is set by the distance between the source and the hood and by the pressure loss created by the air entering the duct. A sophisticated approach is given by Goodfellow.3 Brandt7 lists the following four major groups of hoods and designates the relationship governing the flow into the hood. 1. 2. 3. 4.
Enclosing hoods Rectangular or round hoods Slot hoods Canopy hoods
In each case the minimum control velocity must first be selected. Table 20.1 is a guide for the selection of this control velocity.
20.2.1 FLOW RELATIONSHIP
FOR THE
VARIOUS TYPES
OF
HOODS
20.2.1.1 Enclosing Hoods An enclosing hood completely shuts off the ineffective outside area. Paint booths and laboratory hoods are typical examples of an enclosing hood. Equation 20.1 describes this type of hood where the area, A, is the area of any opening into the hood. This opening is necessary to assure air flow. However, the area should be kept to a minimum for good performance. 20.2.1.2 Rectangular or Round Hoods This type of hood is used for welding, stone surfacing, cleaning and degreasing, and drilling. The shape of the velocity pattern in front of these hoods determines the © 2002 by CRC Press LLC
9588ch20 frame Page 291 Wednesday, September 5, 2001 10:06 PM
TABLE 20.1 Minimum Recommended Control Velocities Condition of Release of Contaminant Released with no significant velocity into quiet air Released with low initial velocity into moderately quiet air Released with considerable velocity or into zone of rapid air movement Released with high velocity or into zone of rapid air movement
Example of Process or Operations Evaporation from open vessels Spray paint booths, welding, dumping of dry materials into containers Spray painting in small booths with high pressure, active barrel or container filling, conveyor loading Grinding, abrasive blasting, surfacing operations on rock
Minimum Control Velocity (ft/min) 100 100–200 200–500
500–2000
velocity into the hood. The total air flow entering the hood is determined by a point at x distance from an imagined suction point. Thus the air velocity V is measured at a distance x from this suction point. The area A is essentially a spherical surface with area = 4πx2 = 12.57x2. Equation 20.1 then becomes, Q = 12.57x 2 V
(20.2)
By experiment Dalla Valle1 noted that the contour shape actually changes and flattens slightly in front of the hood and, thus, he modified this theoretical relationship to the following,
(
)
Q = 10 x 2 + a V
(20.3)
where x = distance in feet along hood centerline from the face of the hood to the point where the air velocity is V ft/min a = area in ft2 of the hood opening This equation is applied to the centerline or axial velocity and not to the velocity at any point. Consequently Dalla Valle1 or Brandt7 should be consulted before applying this equation. 20.2.1.3 Slot Hoods Slot hoods are lateral hoods recommended for ventilation at tanks used for degreasing, pickling, or plating. These hoods are an extreme form of rectangular hood with 50 ft or more of hood opening and are very narrow, with as little as 4 in. of height. © 2002 by CRC Press LLC
9588ch20 frame Page 292 Wednesday, September 5, 2001 10:06 PM
The opening can be visualized as cylindrical surface with an area of 2πrL. Hence Equation 20.1 becomes Q = 2 πrL = 6.28rL
(20.4)
where r = radius in ft or distance from source of suction to point where the air velocity is V L = length of cylinder in ft Brandt7 modifies this equation to account for the actual noncylindrical form of the cylinders. The modified expression is Q = kLWV
(20.5)
where L = length of hood in ft W = tank width in ft (distance from hood to remotest source of contamination) k = constant k = 6.28 for a freely suspended slot hood with cylindrical contours k = 3.27 for freely suspended slot hoods k = 2.8 for slot hoods adjacent to tank tops k = 1.5 if slot hood has flanges or other restricting surfaces at right angles to each other so that air can enter from only one quadrant 20.2.1.4 Canopy Hoods Canopy hoods are a class of rectangular or round hoods. They are used for tanks and furnaces. They are more effective if the contaminate air is warmer than the surrounding air. In this case Brandt7 recommends that the area A be replaced by PY where, P = the perimeter of the hood face in ft Y = the perpendicular distance in ft from the hood face to the top of the tank Therefore, Q = PYV
(20.6)
where V = the average velocity through the opening between the hood edge and the tank Della Valle1 found that for canopy hoods located between 3.5 and 4 ft above the source of contamination, the velocity at the top edge of the tank was about 0.7 of the average velocity. Equation 20.6 was then modified to Q = 1.4 PDV © 2002 by CRC Press LLC
(20.7)
9588ch20 frame Page 293 Wednesday, September 5, 2001 10:06 PM
where V is now the minimum control velocity given in Table 20.1. Note that the constant could be as low as 1.0 if the canopy hood is close to the surface from which this contaminant source is coming. Also, the constant could be greater than 1.4 if the distance between the hood and the contaminant source is much greater than 4 ft.
20.3 DUCT DESIGN Ducts have the purpose of carrying the contaminated air from a hood, a piece of process equipment, or another piece of control equipment to another piece of equipment or to the discharge stack. Ducts can be water cooled, refractory lined, or made of stainless steel or plain carbon steel. For corrosive materials in the air or temperatures in the range of 1150 to 1500°F, stainless steel is used. At lower temperature and noncorrosive materials in the air, plain carbon steel may be used.
20.3.1 SELECTION
OF
MINIMUM DUCT VELOCITY
The ductwork, if carrying particulates, must be designed to keep the particulates in suspension. This means that carrying velocities must be sufficiently high to prevent settling of the largest particles being conveyed. An empirical formula recommended by Brandt7 in use for estimating duct velocity required to prevent settling is S V = 15, 700 S + 1
dP
(20.8)
where V = duct velocity in feet per minute S = specific gravity of the particle d = diameter in inches of the largest particle to be conveyed The above equation has been developed for use with ambient air. While it considers the effect of density of the particle, it ignores the density of the conveying gas. Where the gas density is considerably different from sea level ambient air, the need to alter the equation could be anticipated. Although the velocity chosen by Equation 20.8 is to convey particulates, it is generally desirable in exhaust ductwork to avoid long horizontal runs where possible and to provide some slope to the essentially horizontal portions of the ductwork. In addition, moist and sticky particulates can produce duct buildup, and the velocities predicted by the above equation are not adequate to prevent duct-wall caking in such situations. Higher duct velocities, providing frequent duct cleanouts, and fluorocarbon-sheet lining of the duct are practices employed in such situations. Table 20.2 should be consulted for determining the minimum duct velocity. The area depends on the source of the air flow. If the duct work originates from a hood, the flow rate will be determined from that hood as suggested in Section 20.2.1 If the duct work originates from a piece of process equipment or another piece of control equipment, that equipment will set the flow rate. Knowing the flow rate from
© 2002 by CRC Press LLC
9588ch20 frame Page 294 Wednesday, September 5, 2001 10:06 PM
TABLE 20.2 Minimum Recommended Duct Velocities
Nature of Contaminant Vapors, gases, smoke, fumes, very light dusts Medium density dry dusts Average industrial dust Heavy dust Large particles of heavy moist materials
Examples
Minimum Control Velocity (ft/min)
VOC, all smoke, acid gases
2000
Cotton, jute lint, wood, grain, rubber, polymers Wool, wood, sand blast, wood shavings Lead, foundry emissions, metal turnings Foundry dust, wet lead
3000 4000 5000 5000 and over
either source and the desired velocity estimated from Table 20.2, for example, the area for flow can be determined from Equation 20.1. Then the duct work can be designed. Fluid flow in the duct is described by the mechanical energy balance presented in the next section.
20.3.2 THE MECHANICAL ENERGY BALANCE The following equation comes from Chapter 8. Here the ∆ represents the difference between the output and input value of the variable. ∆U 2 M ∆H + + ∆z g g C = Q + WS 2g C
(8.6)
In this equation, written for turbulent flow where, α = 1.0, the fundamental equation for enthalpy with no phase change or chemical reaction can be written dH = TdS + vdP where S = entropy v = specific volume Then from the definition of entropy, this equation can be rewritten dH = dQ + vdP then P2
∆H = Q +
∫ vdP P1
© 2002 by CRC Press LLC
(20.9)
9588ch20 frame Page 295 Wednesday, September 5, 2001 10:06 PM
And then the mechanical energy balance results from substituting Equation 20.9 into Equation 8.6 above. P2
WS =
∫
vdP +
P1
∆U 2 + g g C ∆z 2g C
(20.10)
This equation applies strictly to a reversible idealized process. Because mechanical energy is dissipated into heat through friction, a term is added for friction. The equation then can be used to describe real situations of fluid flow. Equation 20.10 now becomes P2
WS =
∫
vdP +
P1
∆U 2 + g g C ∆z + F 2g C
(20.11)
where F is the added friction term. Furthermore, for incompressible fluids, P2
∫ vdP = v∆P = P1
∆P ρ
(20.12)
where ρ is the fluid density. Since WS is the shaft work done on a system, the equation can be rewritten to include the efficiency of the fan and motor used in this case. If η is the efficiency, then WS = ηW
(20.13)
where W = the work done on the system by the fan whose efficiency is η Now the mechanical energy balance becomes ηW =
∆P ∆U 2 + + g g C ∆z + F ρ 2g C
(20.14)
The usual practice is to consider the velocity head U2, and the friction head, F, when making a calculation for the total pressure for a fan to encounter, discounting the potential energy loss due to change in elevation ∆z because it will be so small and the change in pressure ∆P will be small since the flow is nearly incompressible. 20.3.2.1 Velocity Head For the average velocity, U = V, the velocity head HV is HV = © 2002 by CRC Press LLC
V2 (in ft of fluid) 2g
(20.15)
9588ch20 frame Page 296 Wednesday, September 5, 2001 10:06 PM
To convert to inches of H2O for the standard conditions of 70°F, 50% air humidity, and 1 atm pressure, this equation becomes
(VP) =
V 4005
2
(20.16)
The velocity head is now designated as the velocity pressure (VP) in inches of H2O. 20.3.2.2 Friction Head The static pressure is sometimes called the friction pressure or friction head. In ducts the friction pressure is due to skin friction generated by flow and energy losses. It is also generated due to turbulence in bends, fittings, obstructions, and sudden expansion and contractions. The friction loss in smooth circular pipes and ducts can be calculated from L V H f = 4f D c 2g
(20.17)
where f = friction factor Dc = duct diameter McCabe et al.8 report that the friction factor, f, can be calculated from the von Karmen equation.
(
)
1 = 4.07 log10 N Re f − 0.60 f
(20.18)
where NRe is the Reynolds Number, N Re =
D C Vρ µ
(20.19)
A nomograph based on this type equation is given in Figure 20.1, friction losses for air in circular ducts. For noncircular, square ducts it is possible to use the hydraulic radius concept. rH ≡
S Lp
where rH = hydraulic radius S = cross-sectional area of the channel LP = perimeter of the channel in contact with the fluid © 2002 by CRC Press LLC
(20.20)
9588ch20 frame Page 297 Wednesday, September 5, 2001 10:06 PM
FIGURE 20.1 Friction losses for air in circular ducts — U.S. customary units. (Copyright 1985, American Society of Heating Refrigeration and Air-Conditioning Engineers Inc., www.ashrae.org. Reprinted by permission from ASHRAE 1985 Handbook — Fundamentals.) © 2002 by CRC Press LLC
9588ch20 frame Page 298 Wednesday, September 5, 2001 10:06 PM
FIGURE 20.2 Equivalent rectangular and circular ducts having equal pressure drop and flow rate. (With permission from Crawford, M., Air Pollution Control Theory, McGraw-Hill Book Co., New York, 1976.)
The diameter used in the Reynolds Number calculation is taken as four times the hydraulic radius. This concept is especially good for square ducts. It is better to use Figure 20.2, equivalent rectangular and circular ducts having equal pressure drop (Crawford9), for nonsquare, rectangular ducts. The effect of bends, fittings, obstructions, and sudden expansion and contractions can be accounted for through a relationship where the head loss is proportional to the velocity in the pipe section squared. H fx = K x
V2 2g c
(20.21)
where Kx = proportionality constant McCabe et al.8 list the following formulas for head loss due to a contraction HfC. S K C = 0.4 1 − D SU
(20.22)
and the head loss due to an expansion, HfE, S K E = 1 − U SD © 2002 by CRC Press LLC
2
(20.23)
9588ch20 frame Page 299 Wednesday, September 5, 2001 10:06 PM
where SU = upstream cross-sectional area SD = downstream cross-sectional area
TABLE 20.3 Head Loss Constant for Fittings and Branches
Cooper and Alley9 have adapted the fitting coefficients listed in Table 20.3 from Industrial Ventilation3 for head loss, HfF, in fittings and branches. For each of these cases where the friction head has been calculated, the head is reported in feet of fluid flowing. The conversion factor to in. of H2O is accomplished by making the following substitution with V in ft/min, which now becomes the velocity pressure VP(std) at standard conditions. VP(std ) =
V2 V = 2g 4005
Fitting Tee 90° elbow 60° elbow 45° elbow Branch into duct 30° angle 45° angle
KfF 2.0 0.9 0.6 0.45 0.2 0.3
2
(20.24)
This velocity pressure, VP(std), is for air flowing at 70°F and 1.0 atm, where the air density is ρ = 0.075 lbm/ft3. A correction can be made for other temperatures as follows, VP(act ) ρ (act ) = VP(std ) ρ (std )
(20.25)
If the pressure is nearly atmospheric, which it most generally is, then the ideal gas law can be applied, and the density ratio can be replaced by the inverse temperature ratio VP(act ) ρ (act ) 530 = = VP(std ) ρ (std ) T (act )
(20.26)
20.4 EFFECT OF ENTRANCE INTO A HOOD The hood static pressure, SPH, measured a short distance from the hood is a direct measurement of the energy required to accelerate the fluid from rest to the duct velocity and to account for the turbulence losses due to the shape of the hood structure. The hood entry losses, SPEH, can be expressed as a function of the velocity pressure as with the fittings. Thus, SPEH = K EH VP
(20.27)
Goodfellow5 made a detailed presentation of this situation. Table 20.4 has been adapted from his work to apply to the hood types described above. © 2002 by CRC Press LLC
9588ch20 frame Page 300 Wednesday, September 5, 2001 10:06 PM
TABLE 20.4 Entrance Loss Coefficients for Hoods Type of Entrance
KEH
Square entrance Round entrance Slot with bend Canopy
0.7–1.25 0.5–0.9 1.6 0.5
The total effect is then the sum of the entry loss, SPHE, and the acceleration to get the air up to the duct velocity which is 1.0 VP. The total static pressure due to the entrance at the hood is then SPH = (1 + K HE ) VP(std )
(20.28)
20.5 TOTAL ENERGY LOSS The static pressure is the same as the friction head. The total pressure, TP, is then the sum of the static pressure, SP, and the velocity pressure, VP. This can be expressed as the sum of duct, hood, and fittings losses.
[
TP = f (D V) + (1 + K H ) + ΣK x
]
(20.29)
Here f(D/V) for the duct is found from Figure 20.1.
20.6 FAN POWER In the case of ductwork requiring a fan, the operating cost is mostly related to the cost of operating the fan. The work of the fan can be calculated from Wf =
K Q ∆Pf η
(20.30)
where k = constant dependent on the units of the other parameters η = mechanical efficiency For Q in acfm, ∆Pf in inches of H2O,
(
k = 0.0001575 HP ft 3 -in. of H 2 O
© 2002 by CRC Press LLC
)
9588ch20 frame Page 301 Wednesday, September 5, 2001 10:06 PM
FIGURE 20.3 Schematic of a hood-duct system.
and Wf is in HP. For Q in m3/s and ∆Pf in Pa, k = 1.0 and Wf is in J/s or watts. The fan static pressure is then ∆Pf = TPoutlet − TPinlet
(20.31)
TPi = SPi + VPi
(20.32)
where
20.7 HOOD-DUCT EXAMPLE Figure 20.3 is a schematic of a hood-duct system to be installed in a chemical plant. One branch of the ductwork begins in a canopy hood. The other branch of the duct work begins in a flanged slot hood. The ductwork ends in an air-pollution-control apparatus. The pressure is 20 in. of H2O at this end of the ductwork due to the pressure drop through the control apparatus. The air is flowing at standard conditions of 1.0 atm and 70°F. The fan which is to be installed has a mechanical efficiency of 83%. Determine the horsepower of the motor required for the fan. Hood Information Hood 1: V = 100 fpm, Y = 3.0 ft, P = 40 ft, KH = 0.5 Q = PYV = 40 × 3 × 100 = 12,000 scfm Hood 2: V = 175 fpm, L = 18 ft, W = 5.33 ft, k = 1.5, KH = 1.0 Q = kLWV = 1.5 × 18 × 8 × 175 = 37,800 scfm Duct Information Duct Area: A = Q/V © 2002 by CRC Press LLC
Duct Diameter: D = (4A/π)1/2
9588ch20 frame Page 302 Wednesday, September 5, 2001 10:06 PM
Determine duct velocity and calculate duct area. The ducts will all be sized as round ducts. Then calculate duct diameter. Round off diameter to the next highest or lowest whole number.
Duct
Flow (scfm)
Velocity (V in fpm)
Area (A in ft2)
D (ft)
Dact (ft)
Aact (fy2)
Vact (fpm)
A B C D
12,000 37,800 49,800 49,800
2000 2000 2000 1000
6.0 18.9 24.9 49.8
2.76 4.91 5.63 7.96
3.0 5.0 5.0 8.0
19.64 19.64 19.64 50.26
1698 1925 2536 990
[
TP = f (D V) + (1 + K H ) + ΣK x Duct A: V = 1698 fpm
]
L = 55 ft 2
1698 V(std ) = = 0.18 4005 f (D V) = (2 in. 100 ft ) × 55 100 = 1.10 in. of H 2 O 1 + K H = 1 + 0.5 = 1.5 K x = 0.45 + 0.30 = 0.75 elbow
branch
TP = (1.10 + 1.5 + 0.75) × 0.18 = 0.60 in. of H 2 O Duct B: V = 1925 fpm
L = 51 ft 2
1925 V(std ) = = 0.23 4005 f (D V) = (1.4 in. 100 ft ) × 51 100 = 0.71 in. of H 2 O 1 + K H = 1 + 1.0 = 2.0 K x = 0.0 TP = (0.71 + 2.0 + 0.0) × 0.23 = 0.62 in. of H 2 O The two branches are nearly balanced, therefore no more calculations are required.
© 2002 by CRC Press LLC
9588ch20 frame Page 303 Wednesday, September 5, 2001 10:06 PM
Duct C: V = 2536 fpm
L = 20 ft 2
2536 V(std ) = = 0.40 4005 f (D V) = (2.6 in. 100 ft ) × 20 100 = 0.52 in. of H 2 O 1 + K H = 0.9 ( no hood ) K x = 0.0 ( no fittings) TP = (0.52 + 0.0 + 0.0) × 0.40 = 0.21 in. of H 2 O Total TP UP to fan: TP = –(0.62 + 0.21) = –0.83 in of H2O Duct D: V = 990 fpm
L = 25 ft
2
990 V(std ) = = 0.06 ft 4005 f (D V) = (0.22 in. 100 ft ) × 25 100 = 0.055 in. of H 2 O 1 + K H = 0.0 ( no hood ) K x = expansion = (1 − 8 12) = 0.11 2
TP = (0.055 + 0.0 + 0.11) × 0.06 + negligible
20.0
at entrance to control equipment
= 20.0 in. of H 2 O
FAN: Q = 49,800 scfm ∆P = 20 – (–0.83) ≈ 21 in. of H2O η = 0.83 Wf =
0.0001575 × 49, 800 × 21 ≈ 200 HP 0.83
REFERENCES 1. Dalla Valle, J. M., Exhaust Hoods, Industrial Press, New York, 1952. 2. Hemeon, W. E. L., Plant and Process Ventilation, Industrial Press, New York, 1954. 3. American Conference of Governmental Industrial Hygienists, Committee on Industrial Ventilation, Industrial Ventilation, A Manual of Recommended Practice, 9th ed., ACGIH, Lansing, MI, 1966.
© 2002 by CRC Press LLC
9588ch20 frame Page 304 Wednesday, September 5, 2001 10:06 PM
4. American Society of Heating, Refrigerating, and Air Conditioning Engineers, ASHRAE Handbook — Heating, Ventilating, and Air Conditioning Systems and Application, Atlanta, GA, 1987. 5. Goodfellow, H. D., Auxiliary equipment for local exhaust ventilation systems, in Air Pollution Engineering Manual, Buonicore, A. J. and Davis, W.T., Eds., Air and Waste Management Association, Van Nostrand Reinhold, New York, 1992, chap. 6. 6. King R. H., Chem. Eng. Progr., 60–69, May, 1997. 7. Brandt, A. D., reference section of Heating and Ventilating, May, 1945. 8. McCabe, W. L., Smith, J. C., and Harriott, P., Unit Operations in Chemical Engineering, 4th ed., McGraw-Hill Book Co., New York, 1985. 9. Cooper, C. D. and Alley, F. C., Air Pollution Control, 2nd ed., Waveland Press, Inc., Prospect Heights, IL, 1994.
© 2002 by CRC Press LLC
9588ch21 frame Page 305 Wednesday, September 5, 2001 10:07 PM
21
Cyclone Design
Cyclones are very common particulate control devices used in many applications, especially those where relatively large particles need to be collected. They are not very efficient for collecting small particles because small particles have little mass that can generate a centrifugal force. Cyclones are very simple devices that use centrifugal force to separate particles from a gas stream. They commonly are constructed of sheet metal, although other materials can be used. They have a low capital cost, small space requirement, and no moving parts. Of course, an external device, such as a blower or other source of pressure, is required to move the gas stream. Cyclones are able to handle very heavy dust loading, and they can be used in hightemperature gas streams. Sometimes they are lined with castable refractory material to resist abrasion and to insulate the metal body from high-temperature gas. A typical cyclone is illustrated in Figure 21.1. It has a tangential inlet to a cylindrical body, causing the gas stream to be swirled around. Particles are thrown toward the wall of the cyclone body. As the particles reach the stagnant boundary layer at the wall, they leave the flowing gas stream and presumably slide down the wall, although some particles may be re-entrained as they bounce off of the wall back into the gas stream. As the gas loses energy in the swirling vortex, it starts spinning inside the vortex and exits at the top. The vortex finder tube does not create the vortex or the swirling flow. Its function is to prevent short-circuiting from the inlet directly to the outlet. Cyclones will work without a vortex finder, although the efficiency will be reduced.
21.1 COLLECTION EFFICIENCY When a particle moves at a constant speed in a circular direction, the velocity vector changes continuously in direction, although not in magnitude. This creates acceleration resulting from a change in direction of the velocity, which is just as real and just as much an acceleration as that arising from the change in the magnitude of velocity. By definition, acceleration is the time rate of change of velocity, and velocity, being a vector, can change in direction as well as magnitude. Force, of course, is defined by Newton’s Second Law (F = ma). Centrifugal force is given by: F= where F = m = V = r =
mV 2 r
centrifugal force mass of particle velocity of particle, assumed to equal inlet gas velocity radius of cyclone body
© 2002 by CRC Press LLC
(21.1)
9588ch21 frame Page 306 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.1 Schematic of standard cyclone.
Because the operating principle of a cyclone is based on using centrifugal force to move particles to the cyclone wall, a simple mistake in the piping configuration, shown in Figure 21.2a, reduces efficiency. Ensure that particles are given a head start in the right direction by using the configuration shown in Figure 21.2b.
21.1.1 FACTORS AFFECTING COLLECTION EFFICIENCY Several factors that affect collection efficiency can be predicted. Increasing the inlet velocity increases the centrifugal force, and therefore the efficiency, but it also increases the pressure drop. Decreasing the cyclone diameter also increases centrifugal force, efficiency, and pressure drop. Increasing the gas flow rate through a given cyclone has the effect of efficiency shown in Equation 21.2: Pt 2 Q1 = Pt 1 Q 2 where Pt = penetration (Pt = 1 – η) η = particle removal efficiency Q = volumetric gas flow © 2002 by CRC Press LLC
0.5
(21.2)
9588ch21 frame Page 307 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.2 Inlet piping configuration.
Interestingly, decreasing the gas viscosity improves efficiency, because drag force is reduced. Centrifugal force drives the particle toward the wall of the cyclone, while drag opposes the centrifugal force. The terminal velocity of the particle toward the wall is the result of the force balance between the centrifugal and drag forces. Increasing gas to particle density difference affects penetration as shown in Equation 21.3: Pt 2 µ 2 = Pt1 µ1
0.5
(21.3)
where: µ = gas viscosity. Note that decreasing the gas temperature increases the gas density, but contrary to intuition, decreases the gas viscosity, which reduces drag force and results in a small efficiency improvement. However, decreasing the gas temperature also decreases the volumetric flow rate, which affects efficiency as described above in Equation 21.2. Finally, particle loading also affects efficiency. High dust loading causes particles to bounce into each other as they move toward the wall, driving more particles toward the wall and their removal. Pt 2 L1 = Pt1 L 2
0.18
where L = inlet particle concentration (loading).
© 2002 by CRC Press LLC
(21.4)
9588ch21 frame Page 308 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.3 Generalized efficiency relationships.
Figure 21.3 shows generalized efficiency relationships for high-efficiency conventional and high-throughput cyclones. It simply demonstrates that the dimensions of the cyclones can be tuned to the application. Figure 21.4 and Table 21.1 illustrate typical cyclone dimensions. Relative dimensions are based upon the diameter of the body of the cyclones. High-efficiency cyclones tend to have long, narrow bodies, while high-throughput cyclones generate less pressure drop with fat bodies.
21.1.2 THEORETICAL COLLECTION EFFICIENCY The force balance between centrifugal and drag forces determines the velocity of the particles toward the wall. Resident time of particles in the cyclone, which allows time for particles to move toward the wall, is determined by the number of effective turns that the gas path makes within the cyclone body. An empirical relationship for the number of effective turns is provided in Equation 21.5: Ne = where Ne = H = Lb = Lc =
L 1 L + c H b 2
(21.5)
number of effective turns height of the tangential inlet length of cyclone body length of cyclone lower cone
The theoretical efficiency of a cyclone can be calculated by balancing the terminal velocity with the residence time resulting from a distance traveled in the cyclone. This force and time balance results in Equation 21.6: © 2002 by CRC Press LLC
9588ch21 frame Page 309 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.4 Cyclone dimensions.
TABLE 21.1 Typical Cyclone Dimensions High Efficiency Inlet height Inlet width Gas exit diameter Body length Cone length Vortex finder Dust outlet diameter
H/D W/D De /D Lb /D Lc /D S/D Dd /D
d px
Standard
0.44 0.21 0.4 1.4 2.5 0.5 0.4
0.5 0.25 0.5 1.75 2.0 0.6 0.4
x 9µW = 100 π N e Vi ρp − ρg
(
)
0.8 0.35 0.75 1.7 2.0 0.85 0.4
0.5
where dpx = diameter of a particle with x% removal efficiency µ = viscosity © 2002 by CRC Press LLC
High Throughput
(21.6)
9588ch21 frame Page 310 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.5 Lapple’s efficiency curve.
W Ne Vi ρp ρg
= = = = =
inlet width number of effective turns inlet velocity density of particle density of gas
21.1.3 LAPPLE’S EFFICIENCY CORRELATION Unfortunately, the theoretical efficiency relationship derived above does not correlate well with real data. The relationship works reasonably well for determining the 50% cut diameter (the diameter of the particle that is collected with 50% efficiency). To better match data with reasonable accuracy, the efficiency of other particle diameters can be determined from Lapple’s empirical efficiency correlation,1 which is shown in Figure 21.5. This correlation can be set up for automated calculations using the algebraic fit given by Equation 21.7: ηj =
© 2002 by CRC Press LLC
1 d 1 + p 50 d pj
2
(21.7)
9588ch21 frame Page 311 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.6 Effect of slope parameter, B.
where ηj = collection efficiency of particle with diameter j dp50 = diameter of particles with 50% collection efficiency dpj = diameter of particle j Lapple’s efficiency curve was developed from measured data for cyclones with the “standard” dimensions shown in Table 21.1. The efficiency curve can be tailored for different industrial cyclone dimensions by adding a slope parameter, B, to the correlation: ηj =
1 d 1 + p 50 d pj
B
(21.8)
where B = slope parameter, typically ranging from 2 to 6. Figure 21.6 illustrates the effect of the slope parameter, B. Note that the larger value for B results in a sharper cut. Since more mass is associated with larger particles, the sharper cut results in higher overall mass removal efficiency.
21.1.4 LEITH
AND
LICHT EFFICIENCY MODEL
Other models have been developed to predict cyclone performance. One is the Leith and Licht model2 shown in Equation 21.9: © 2002 by CRC Press LLC
9588ch21 frame Page 312 Wednesday, September 5, 2001 10:07 PM
(
η = 1 − exp − Ψ d M p M=
)
(21.9)
1 m +1
(21.9a)
0.3 T m = 1 − 1 − 0.67D0c .14 283
(
)
(21.9b)
M
K Qρp C′ (m + 1) 2 Ψ = 2 18 µ D3C where dp DC T K Q ρp C′ µ
= = = = = = = =
(21.9c)
particle diameter in meters cyclone body diameter in meters gas temperature, °K dimensional geometric configuration parameter volumetric gas flow particle density cunningham slip correction factor gas viscosity
The geometric configuration parameter is estimated based on the cyclone configuration. Table 21.2 shows relative dimensions for three types of cyclones: the standard cyclone, the Stairmand design,3 and the Swift design.4 Note that the Stairmand and the Swift cyclones have smaller inlet openings than the standard design, which means a higher inlet velocity for the same size body. This results in more centrifugal force and increased efficiency. In the Leith and Licht model, a larger geometric configuration parameter results in a higher predicted efficiency.
TABLE 21.2 Geometric Configuration Parameter
Inlet height Inlet width Gas exit diameter Body length Cone length Vortex finder Dust outlet diameter Geometric configuration paramater
© 2002 by CRC Press LLC
H/D W/D De /D Lb /D Lc /D S/D Dd /D K
Standard
Stairmand
0.5 0.25 0.5 2.0 2.0 0.625 0.25 402.9
0.5 0.2 0.5 1.5 2.5 0.5 0.375 551.3
Swift 0.44 0.21 0.4 1.4 2.5 0.5 0.4 699.2
9588ch21 frame Page 313 Wednesday, September 5, 2001 10:07 PM
FIGURE 21.7 Cyclone efficiency curves.
21.1.5 COMPARISON
OF
EFFICIENCY MODEL RESULTS
Efficiency models are adequate for getting a fair idea of performance, but there can be a rather wide variation in model predictions. Part, but not all, of the variation can be explained by empirical factors for the cyclone configuration. Figure 21.7 shows cyclone efficiency curves as a function of particle diameter based on several sources. Each curve is based upon the same gas flow and gas and particle conditions. The lowest efficiency is predicted by Lapple’s curve for a standard cyclone. Interestingly, the Leith and Licht model for the same standard cyclone predicts a significantly higher efficiency. The Leith and Licht model for the higher efficiency Stairmand and Swift cyclone designs shows incremental improvement over the standard design. Vendor data also were collected for the same set of gas and particle conditions, with significant predicted performance improvement. Perhaps the vendors were being overoptimistic about their designs, or perhaps there have been significant improvements in cyclone design over the years. It does point out that performance guarantees for cyclones must be written with specific information about the gas and particle properties, including the particle size distribution, to ensure that vendor guarantees can be measured and substantiated after installation.
21.2 PRESSURE DROP Pressure drop provides the driving force that generates gas velocity and centrifugal force within a cyclone. Several attempts have been made to calculate pressure drop from fundamentals, but none of them has been very satisfying. Most correlations are based on the number of inlet velocity heads as shown in Equation 21.10:
© 2002 by CRC Press LLC
9588ch21 frame Page 314 Wednesday, September 5, 2001 10:07 PM
∆P = where ∆P ρg Vi NH
= = = =
1 ρ V2 N 2gc g i H
(21.10)
pressure drop gas density inlet gas velocity pressure drop expressed as number of the inlet velocity heads
One of the correlations for number of inlet velocity heads is by Miller and Lissman:5 D N H = K ∆P1 De
2
(21.11)
where K∆P1 = constant based on the cyclone configuration and operating conditions D = diameter of the cyclone body De = diameter of the exit tube A typical value for K∆P in the Miller and Lissman correlation is 3.2. For the standard cyclone configuration described above, the Miller and Lissman correlation results in 12.8 inlet velocity heads. Another correlation for number of inlet velocity heads is by Shepherd and Lapple:6 N H = K ∆P 2 where K∆P2 H W De
= = = =
HW De2
(21.12)
constant for cyclone configuration and operating conditions height of the inlet opening width of the inlet opening diameter of the exit tube
The value for K∆P in the Shepherd and Lapple correlation is different, typically ranging from 12 to 18. The Shepherd and Lapple correlation results in 8 inlet velocity heads for the standard cyclone dimensions, 6.4 inlet velocity heads for the Stairmand cyclone design, and 9.24 inlet velocity heads for the Swift cyclone design. As can be seen, there is a substantial difference among the correlations. Again, it is best to rely upon vendors’ experience when your own experience is lacking; however, to enforce a performance guarantee, ensure that the specification is well-written and can be documented for the expected conditions.
© 2002 by CRC Press LLC
9588ch21 frame Page 315 Wednesday, September 5, 2001 10:07 PM
21.3 SALTATION The previous discussion of efficiency and pressure drop leaves the impression that continually increasing the inlet gas velocity can give incrementally increasing efficiency. However, the concept of “saltation” by Kalen and Zenz7 indicates that, more than just diminishing return with increased velocity, collection efficiency actually decreases with excess velocity. At velocities greater than the saltation velocity, particles are not removed when they reach the cyclone wall, but are kept in suspension as the high velocity causes the fluid boundary layer to be very thin. A correlation for the saltation velocity was given by Koch and Licht:8
(
ρp − ρg Vs = 2.055D0.067Vi0.667 4gµ 3ρ2g where Vs = D = Vi = g = µ = ρp = ρg = W =
)
0.333
W 0.4 D 0.333 1 − W D
(21.13)
saltation velocity, ft/s cyclone diameter, ft inlet Velocity, ft/s acceleration of gravity, 32.2 ft/s2 gas viscosity, lbm/ft-sec particle density, lbm/ft3 gas density, lbm/ft3 width of inlet opening, ft
The maximum collection efficiency occurs at Vi = 1.25Vs, which typically is between 50 and 100 ft/s.
REFERENCES 1. Lapple, C. E., Processes use many collector types, Chem. Eng., 58, 5, May 1951. 2. Leith, D. and Licht, W., The collection efficiency of cyclone type particle collectors — A new theoretical approach, AIChE Symp. Series, 126 (68), 1972. 3. Stairmand, C. J., The design and performance of cyclone separators, Trans. Ind. Chem. Eng., 29, 1951. 4. Swift, P., Dust control in industry, Steam Heating Eng., 38, 1969. 5. Miller and Lissman, Calculation of cyclone pressure drop, presented at meeting of American Soc. of Mech. Eng., New York, December 1940. 6. Shepherd, C. B. and Lapple, C. E., Flow pattern and pressure drop in cyclone dust collectors, Ind. Eng. Chem., 32(9), 1940. 7. Kalen, B., and Zenz, F., Theoretical empirical approach to saltation velocity in cyclone design, AIChE Symp. Series, 70(137), 1974. 8. Koch, W. H. and Licht, W., New design approach boosts cyclone efficiency, Chem. Eng., 84(24), 1977.
© 2002 by CRC Press LLC
9588ch22 frame Page 317 Wednesday, September 5, 2001 10:08 PM
22
Design and Application of Wet Scrubbers
22.1 INTRODUCTION In wet scrubbing, an atomized liquid, usually water, is used to capture particulate dust or to increase the size of aerosols. Increasing size facilitates separation of the particulate from the carrier gas. Wet scrubbing can effectively remove fine particles in the range from 0.1 µm to 20 µm. The particles may be caught first by the liquid, or first on the scrubber structure, and then washed off by the liquid. Because most conventional scrubbers depend upon some form of inertial collection of particulates as the primary mechanism of capture, scrubbers when used in a conventional way have a limited capacity for controlling fine particulates. Unfortunately inertial forces become insignificantly small as particle size decreases, and collection efficiency decreases rapidly as particle size decreases. As a result, it becomes necessary to greatly increase the energy input to a wet scrubber to significantly improve the efficiency of collection of fine particles. Even with great energy inputs, wet scrubber collection efficiencies are not high with particles less than 1.0 µm in size. Wet scrubbers have some unique characteristics useful for fine particulate control. Since the captured particles are trapped in a liquid, re-entrainment is avoided, and the trapped particles can be easily removed from the collection device. Wet scrubbers can be used with high-temperature gases where cooling of the gas is acceptable and also with potentially explosive gases. Scrubbers are relatively inexpensive when removal of fine particulates is not critical. Also, scrubbers are operated more easily than other sophisticated types of particulate removal equipment. Wet scrubbers can be employed for the dual purpose of absorbing gaseous pollutants while removing particulates. Both horizontal and vertical spray towers have been used extensively to control gaseous emissions when particulates are present. Cyclonic spray towers may provide slightly better particulate collection as well as higher mass transfer coefficients and more transfer units per tower than other designs. Although there is theoretically no limit to the number of transfer units that can be built into a vertical countercurrent packed tower or plate column, if it is made tall enough, there are definite limits to the number of transfer units that can be designed into a single vertical spray tower. As tower height and gas velocities are increased, more spray particles are entrained upward from lower levels, resulting in a loss of true countercurrency. Achievable limits have not been clearly defined in the literature, but some experimental results have been provided.1 There have been reports of 5.8 transfer units in a single vertical spray tower and 3.5 transfer units in horizontal spray chambers. Researchers have attained 7 transfer units in a single commercial cyclonic spray tower. Theoretical discussion and a design equation for
© 2002 by CRC Press LLC
9588ch22 frame Page 318 Wednesday, September 5, 2001 10:08 PM
cyclonic spray towers of the Pease-Anthony type are available. Whenever more transfer units are required, spray towers can be used in series. When heavy particulate loads must be handled or are of submicron size, it is common to use wet particulate collectors that have high particle collection efficiencies along with some capability for gas absorption. The Venturi scrubber is one of the more versatile of such devices, but it has absorption limitations because the particles and spray liquid have parallel flow. It has been indicated that venturi scrubbers may be limited to three transfer units for gas absorption.1 The liquidsprayed wet electrostatic precipitator is another high-efficiency particulate collector with gas absorption capability. Limited research tests have indicated that the corona discharge enhances mass-transfer absorption rates, but the mechanism for this has not been established. The disadvantages of wet scrubbers include the necessity of reheating cooled scrubber effluents for discharge up a stack. Furthermore, the water solutions may freeze in winter and become corrosive at other times. In some cases, the resultant liquid sludge discharge may have to be treated for disposal. It should be noted also that operating costs can become excessive due to the high energy requirements to achieve high collection efficiencies for removal of fine particulates.
22.2 COLLECTION MECHANISMS AND EFFICIENCY In wet scrubbers, collection mechanisms such as inertial impaction, direct interception, Brownian diffusion, and gravity settling apply in the collection process. Most wet scrubbers will use a combination of these mechanisms, therefore, it is difficult to classify a scrubber as predominately using one particular type of collection mechanism. However, inertial impaction and direct interception play major roles in most wet scrubbers. Thus, in order to capture finer particles efficiently, greater energy must be expended on the gas. This energy may be expended primarily in the gas pressure drop or in atomization of large quantities of water. Efficiency of collection may be unexpectedly enhanced in a wet scrubber through methods that cause particle growth. Particle growth can be brought about by vapor condensation, high turbulence, or thermal forces in the confines of the narrow passages in the scrubber structure. Condensation, the most common growth mechanism, occurs when a hot gas is cooled or compressed. The condensation will occur preferentially on existing particles rather than producing new nuclei. Thus, the dust particles will grow larger and will be more easily collected. When hydrophobic dust particles must be collected, there is evidence that the addition of small quantities of nonfoaming surfactants may enhance collection. The older literature is contradictory on this point, but careful experiments by Hesketh2 and others indicate enhancement can definitely occur.
22.3 COLLECTION MECHANISMS AND PARTICLE SIZE When a gas stream containing particulates flows around a small object such as a water droplet or a sheet of water, the inertia of the particles causes them to move
© 2002 by CRC Press LLC
9588ch22 frame Page 319 Wednesday, September 5, 2001 10:08 PM
toward the object where some of them will be collected. This phenomenon is known as inertial impaction, which customarily describes the effects of small-scale changes in flow direction. Because inertial impaction is effective on particles as small as a few tenths of a micrometer in diameter, it is the most important collection mechanism for wet scrubbers. Since this mechanism depends upon the inertia of the particles, both their size and density are important in determining the efficiency with which they will be collected. All important particle properties may be lumped into one parameter, the aerodynamic impaction diameter which can be calculated from the actual particle diameter by the following relationship:
(
d ap = d p p p C′ where dap dp pp C′
= = = =
)
12
(22.1)
aerodynamic impaction diameter in µm-gm/cm3 physical diameter in µm density of particle in gms/cm3 Cunningham’s correction factor
By a fortunate circumstance, most methods for measuring particle size determine the aerodynamic impaction diameter. The Cunningham correction factor is given by the following formulas: C′ = 1 +
0.55d p 2λ 1.257 + 0.400 exp − dp λ λ=
where λ dp µ MW ρg R T
= = = = = = =
µ 8RT πMW 0.499 ρg
(22.2)
(22.3)
mean free path of the gas in m diameter of particle in m gas viscosity in N-s/m2 or kg/m-s mean molecular weight of the gas gas density in kg/m3 universal gas constant (8.3144 J/kg-mol-K) gas temperature in K
For air at room temperature and pressure, Equation 22-4 is a good approximation of C′: C′ = 1.0 +
© 2002 by CRC Press LLC
0.16 dp
(22.4)
9588ch22 frame Page 320 Wednesday, September 5, 2001 10:08 PM
Knowing the value of the mean free path of molecules at a given temperature and pressure, the mean free path at other conditions can be calculated from Equation 22.5: µ λ = λo µo
T T o
12
Po p
(22.5)
where λo = 0.0653 µm for air at 23°C and 1.0 atm µo, To, Po = viscosity, temperature, and pressure, respectively, at the same conditions for which λo is known
22.4 SELECTION AND DESIGN OF SCRUBBERS Calvert3 and co-workers have prepared an extensive report of wet scrubbers from both theoretical considerations and literature data. In considering the types of scrubbers to use for a particular application, the designer must have in mind the required collection efficiency for a particular size emission. The data of Table 22.1 can be used as a rough guide for initial consideration of adequacy of different devices.
22.5 DEVICES FOR WET SCRUBBING The following material is a compilation of facts and figures for typical wet scrubbers. Table 22.2 serves as a guideline to the general operational characteristics of various types of devices. Following Table 22.2 are Figures 22.1 through 22.6 which are schematics illustrating the six type of scrubbers listed in the table. The scrubbers depicted in Figures 22.1 and 22.2 are the same as Figures 11.2 and 11.3 shown in
TABLE 22.1 Particle Size Collection Efficiency of Various Wet Scrubbers4-6 Type of Scrubber Gravity spray towers Cyclonic spray towers Impingement scrubbers Packed and moving bed scrubbers Plate and slot scrubbers Fiber bed scrubbers Water jet scrubbers Dynamic Venturi a
Pressure Drop in Pa
Minimum Collectible Particle Diametera in m
125–375 500–2500 500–4000 500–4000 1200–4000 1000–4000 — — 2500–18,000
10 2–6 1–5 1–5 1–3 0.8–1 0.8–2 1–3 0.5–1
Minimum particle size collected with approximately 85% efficiency.
© 2002 by CRC Press LLC
9588ch22 frame Page 321 Wednesday, September 5, 2001 10:08 PM
TABLE 22.2 Characteristics of Wet Scrubbers
Efficiency (dp-µm) Velocity (ft/s) Nozzle pressure (psig) Pressure drop (in. of H2O) Liquid to gas ratio (gal/1000 ft3) Power input (HP/1000 cfm)
Spray Tower
Cyclonic Spray Tower
Self-Induced Sprays
Plate Scrubbers
Venturi
Venturi Jet
90% >8 3–6
95% >5 150–250 inlet
90% >2 —
97 >5 —
95 >0.2 150–500 throat
92 >1.0 —
35–50
—
—
—
—
50–150
1–4
4–8
8–12
8–12
—
10–20
3–6
0.5
2–3
3–10
2–4 (Draft) 30–80
0.5–2
1–3.5
2–4
2–5
3–12
—
Chapter 11, absorption for HAP and VOC control. This emphasizes the fact that these devices may be used to collect both particles, primarily by inertial impaction, and to absorb gases, usually with a solvent that also promotes chemical reaction.
22.6 THE SEMRAU PRINCIPLE AND COLLECTION EFFICIENCY7,8 In order to capture fine particles, greater energy must be expended on the gas. There are two ways to do this: 1. Increase the gas pressure 2. Atomize large quantities of water Efficiency of collection may be unexpectedly enhanced in a wet scrubber through methods that will cause particle size growth. Particle growth can be brought about by: • Lower temperatures that cause vapor condensation • Increased flow rates that increase turbulence • Thermal gradients in the narrow passages of the scrubber which increases diffusion of particles into the liquid Condensation is the most common growth mechanism. The hot gasses are cooled by the lower temperatures resulting from contact with the scrubbing liquid. The gasses may also be compressed in the narrow passages of the scrubber, which would tend to enhance condensation. The condensation occurs on the existing particles rather than the new nuclei. Thus the dust particles will grow larger and will be more easily collected. © 2002 by CRC Press LLC
9588ch22 frame Page 322 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.1 Spray tower (same as Figure 11.2 for absorption): • Countercurrent vertical tower • Droplets sufficiently large so that the settling velocity is greater than the upward gas velocity • Droplet size controlled to optimize particle contact and to provide easy droplet separation
In general the efficiency of a wet scrubber is directly related to the energy expended to produce the gas–liquid contact. The more energy expended, the greater the turbulence in the contacting process and the higher the efficiency of collection. Semrau7,8 defined the contacting power as the energy dissipated per unit volume of gas treated. Contacting power should be determined from the friction loss across the wetted portion of the scrubber. Pressure losses due to the gas stream kinetic energy should not be included. However, energy provided by the mechanical devices along with the energy provided by the gas and liquid are part of the contacting power. Semrau treated scrubber efficiency by relating the number of transfer units to the contacting power as follows: © 2002 by CRC Press LLC
9588ch22 frame Page 323 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.2 Cyclonic spray tower (same as Figure 11.3 for absorption): • Gas is introduced tangentially which increases the forces of collision and relative velocity of the droplets and gas stream • Well designed cyclonic spray towers greatly increase the collection of particles smaller than 10 µm when compared to simple countercurrent spray towers • Droplets produced by spray nozzles • Droplets collected by centrifugal force • Two types: (1) spinning motion imparted by tangential entry, (2) spinning motion produced by fixed vanes
N t = α Ptβ where: Nt = number of transfer units, dimensionless Pt = contacting power, hp/1000 cfm or kWh/1000 m3 © 2002 by CRC Press LLC
(22.6)
9588ch22 frame Page 324 Wednesday, September 5, 2001 10:08 PM
Fan
Outlet
Inlet Baffle
Liquid level
FIGURE 22.3 Self-induced spray tower: • Air impinges on a liquid surface then on a series of baffles • Particles are initially captured in pool of water by direct interception or inertial impingement • Some water is atomized into spray droplets which aids collection • A final change in gas direction, or by baffles, serves as an entrainment separator • The water circulation rate is low, and water is primarily required to replace evaporation losses • Droplets are formed by breaking through a sheet of liquid or by impinging on a pool of water • Droplets collected by gravity attraction
α = coefficient to make Nt dimensionless β = dimensionless exponent The overall efficiency, ηO, of the scrubber can be calculated from the following: ηo = 1 − exp( − N t ) © 2002 by CRC Press LLC
(22.7)
9588ch22 frame Page 325 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.4(a) Impingement plate scrubber.
The following plot from Semrau, Figure 22.7, is a performance curve for a venturi scrubber collecting a metallurgical fume.8 Table 22.3 reports values of the parameters that could be used in Semrau’s equation for the number of transfer units.7
22.7 A MODEL FOR COUNTER-CURRENT SPRAY SCRUBBERS Drops are formed by atomizer nozzles and then sprayed into the gas stream. In the counter-current tower, drops settle vertically against the rising gas stream which is carrying the particles. Atomization provides a wide variety of droplet size. It is customary to take the Sauter mean drop diameter equivalent to the volume/surface area ratio and defined by the following equation to represent all the droplets.
dd =
© 2002 by CRC Press LLC
58, 600 σ L Vg ρL
0.5
µL + 597 0.5 ( σ L ρL )
0.45
QL 1000 QG
1.5
(22.8)
9588ch22 frame Page 326 Wednesday, September 5, 2001 10:08 PM
Bubble cap plate
Sieve plate
Liquid out
Perforations
Liquid
Plate
Gas
Gas
(b)
FIGURE 22.4(b) Several plate types. • Plates of all types used — sieve plates, slot plates, valve trays, and bubble cap trays • One modification, the turbulent contact absorber, uses a layer of fluidized plastic spheres
where dd ρL σL µL Vg QL QG
= Sauter mean droplet diameter, µm = Density of the liquid, gm/cm3 = Liquid surface tension, dyne/cm = Liquid viscosity, poise = Superficial gas velocity, cm/s = Volumetric liquid flow rate, M3/s = Volumetric gas flow rate, M3/s
Inertial impaction is depicted in Figure 22.8, primary capture mechanism. In this case of inertial impaction, a particle is carried along by the gas stream. Approaching the collecting body which is a water droplet in the case of a spray scrubber, the particles tend to follow the streamlines. However, for many particles, their inertia will result in the particle separating from the gas stream and striking the water droplet. The result is for the water droplet to collect the particle. The separation number in Figure 22.8, NSi, is the same as the inertial impaction parameter, Kp, defined by the following equation:
© 2002 by CRC Press LLC
9588ch22 frame Page 327 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.5 Venturi scrubber: • Gas accelerated at throat • Atomized water droplets added at throat as a spray or jet, collect particles • Can be combined with a cyclonic collector to disengage water droplets from air stream • Has a large pressure drop
Nsi = K ρ = K mρp D2p where C′ ρP dP VP µg
= = = = =
Vp 18µ g D b
=
C′ ρρ d ρ2 Vp 18µ g d d
=
d ap2 Vp 18µ g d d
(22.9)
Cunningham correction factor particle density, gm/cm3 physical particle diameter, cm particle velocity, cm/s gas viscosity, poise
Figure 22.9 exhibits single-droplet target efficiency for ribbons, spheres, and cylinders. The curves apply for conditions in which Stokes’ Law holds for the motion of the particle. Equation 22.10 is an approximate equation for a single-droplet target efficiency, ηd. Kρ ηd = K ρ + 0.35
© 2002 by CRC Press LLC
2
(22.10)
9588ch22 frame Page 328 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.6 Venturi jet scrubber: • Used for fume scrubbing • High pressure water atomized from a jet nozzle into a throat of a Venturi which induces the flow of the gas to be scrubbed
22.7.1 APPLICATION
TO A
SPRAY TOWER
The principles stated above can be used to derive a model for the design of a spray tower. This model can be used along with particle distribution to determine the overall penetration or efficiency of a spray tower making use of the grade efficiency calculation method. The basic assumptions for the model are 1. Droplets are of uniform size and immediately reach the terminal velocity. 2. Droplets do not channel down to the scrubber walls. Figure 22.10 depicts the relative velocities of a water droplet and a particle. In this case we can define the following parameters: Vdt = droplet terminal velocity, cm/s Vpt = particle terminal velocity, cm/s Vg = superficial gas velocity, cm/s © 2002 by CRC Press LLC
4
96
3
95 90 o
2
80
o o 1 0.9 0.8 0.7 0.6 0.5 0.4
o
70
o
60
o
Efficiency, percent
Number of transfer units, Nt
9588ch22 frame Page 329 Wednesday, September 5, 2001 10:08 PM
50 40 1
2
3
4
5
6 7 8 9 10
Contacting power, hp/1000 cfm FIGURE 22.7 Performance curve for a Venturi scrubber collecting a metallurgical fume. (Used with permission from Semrau, K. T., J. Air Poll. Contr. Technol. Assoc., 13(12), 587, 1963.)
TABLE 22.3 Correlation Parameters for Semrau’s Equation Correlation Parameter Aerosol Lime Kiln Dust and Fume Raw gas (lime dust and soda fume) Prewashed gas (soda fume) Talc dust Black liquor recovery furnace fume Cold scrubbing water humid gases Hot fume solution for scrubbing (humid gases) Hot black liquor for scrubbing (dry gases) Phosphoric acid mist Foundry cupola dust Open hearth steel furnace fume Talc dust Ferrosilicon furnace fume
Scrubber
Venturi and cyclonic spray Venturi, pipeline and cyclonic spray Venturi Orifice and pipeline Venturi and cyclonic spray
1.47 0.915
1.05 1.05
2.97 2.70 1.75
0.362 0.362 0.620
Venturi, pipeline, and cyclonic spray Venturi evaporator Venturi Venturi Venturi Cyclone Venturi and cyclonic spray
0.740
0.861
0.522 1.33 1.35 1.26 1.16 0.870
0.861 0.647 0.621 0.569 0.655 0.459
Source: Used with permission from Semrau, K. T., J. Air Poll. Contr. Technol. Assoc., 10(3), 200, 1960.
© 2002 by CRC Press LLC
9588ch22 frame Page 330 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.8 Primary capture mechanism.
1.0
D
D
bb
0.7
b
on
0.8
re
D
b
Ri
de
Cy
lin
0.5
r
he
0.6
Sp
Target efficiency, ηt
b
0.9
0.4 0.3 0.2
Intercepts: Ribbon or cylinder: 1/16 Sphere: 1/24
0.1 0 0.01
0.1
1.0
10
100
Separation Number, utvo/gLDb
FIGURE 22.9 Single-droplet target efficiency for ribbons, spheres, and cylinders.
Vg = QG/A QG = Gas flow rate in m3/s A = cross sectional area of tower, m2 It is assumed that the particle travels with velocity, Vp, equal to the gas velocity, i.e., Vp = Vg A mass balance is made next, based on Figure 22.11, mass balance in tower cross-section. The mass balance:
© 2002 by CRC Press LLC
9588ch22 frame Page 331 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.10 Relative velocities of a water droplet and a particle.
FIGURE 22.11 Mass balance in tower cross-section.
Mass in − Mass out − Mass collected = Accumulation C Q G − (C + dCi ) Q G − M c = 0 The total number of drops entering the cross-section per unit of time: QL πd d3 6 The mass of particles collected by each drop per unit time:
© 2002 by CRC Press LLC
(22.11)
9588ch22 frame Page 332 Wednesday, September 5, 2001 10:08 PM
(
)
ηd Vdt − Vpt Ci
πd d2 4
(22.12)
The time for the droplet to pass down through the section dz, dz Vdt − Vg
(22.13)
This is essentially the contact time for the droplet. The mass of particles collected by one droplet during this contact time is then, πd d2 dz ηd Vdt − Vpt Ci 4 Vdt − Vg
(
)
(22.14)
Multiply Equation 22.14 by Equation 22.11, the total amount of drops, and this will be Mc, the total mass collected. The mass balance may then be written, −Q G dCi =
3 Vdt − Vpt Q L η C dZ 2 d Vpt − Vg d d i
(22.15)
Separate the variables and integrate:
−
∫
C
dCi 3 = ηd 2 Co C i
∫
z
o
Vdt − Vpt Q dZ L V −V Q d dt g G d
(22.16)
resulting in Pt =
3 V − V Q Z C pt L = exp − ηd dt Q d 2 Co V V − g g d dt
(22.17)
Application of the equation usually involves the following assumptions: 1. Vdt Vpt 2. At Calvert’s suggestion, (QL/QG) is multiplied by 0.2 to correct for wall effects and other loss of effectiveness by the falling droplets. Then the final formula is V Q Z dt L Pt = exp −0.30 ηd Q d − V V dt g G d © 2002 by CRC Press LLC
(22.18)
9588ch22 frame Page 333 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.12 The effect of the model parameters on penetration.
Figure 22.12 illustrates the effect of the model parameters on penetration. As the penetration decreases, the efficiency increases. Therefore, increasing ηd, QL, or Z will increase efficiency, while increasing dd or decreasing Qg will decrease efficiency. Note that as dd becomes smaller, the efficiency should increase. In practice, this is true until the droplet diameter, dd, becomes so small that the drag coefficient results in a force large enough so that the effect of the water spray is reduced. Thus the spray becomes less effective in collecting particulates, and the efficiency decreases again. There should, therefore, be an optimum drop size where the efficiency is the maximum. Figure 22.13 presents data to confirm this conclusion.
22.8 A MODEL FOR VENTURI SCRUBBERS Calvert et al.3 have developed a model similar to Equation 22.18 for several different types of scrubbers. Following is a model for Venturi scrubbers. Q V ρ d Pt = exp L G L d B 55Q G µ G K f + 0.7 0.49 1 B = −0.7 − K p f + 1.4 ln p + 0.7 0.7 + K p f K p © 2002 by CRC Press LLC
(22.19)
9588ch22 frame Page 334 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.13 Optimum droplet size for collection by inertial impaction when droplets are moving in the gravitational field of the earth in a spray tower. (With permission from Stairmand, C. J., Transactions of the Institution of Chemical Engineers, 28, 130, 1950.)
where Kp = inertial impaction parameter at throat entrance f = empirical factor (f = 0.25 for hydrophobic particles, f = 0.50 for hydrophilic particles) This model works well for f = 0.50 for a variety of large-scale venturi scrubbers and other spray scrubbers where the spray is atomized by the gas.
22.9 THE CALVERT CUT DIAMETER DESIGN TECHNIQUE The cut diameter method of wet scrubber design was devised by Calvert and his coworkers.3 The method is based on the concept that the most significant single parameter to define both the difficulty of separating particles from the carrier gas and the performance of a scrubber, is the particle diameter for which collection efficiency is 50%. As noted previously, aerodynamic diameter defines the particle properties of importance in designing wet scrubbers which depend on inertial impaction as the collection mechanism. In most cases of particle clean-up, a range of particle sizes is involved. The overall collection efficiency will depend on the amount of each size present and on the efficiency of collection for that size. In order to account for the size distribution effects, the difficulty of separation is defined as the aerodynamic diameter at which collection efficiency (or penetration) must be 50% in order that the required overall efficiency for the entire size distribution be attained. This particle size is defined as the separation cut diameter (dRC). The Calvert design technique is based on a lognormal distribution of particle sizes and relates the separation cut diameter to the overall penetration and the size distribution parameters. © 2002 by CRC Press LLC
9588ch22 frame Page 335 Wednesday, September 5, 2001 10:08 PM
TABLE 22.4 Values of exponent B In Equation 22.20 Type of Scrubber
Value of B
Centrifugal scrubber Packed towers Sieve plates Venturi scrubbers
0.67 2.0 2.0 2.0
In order to design a wet scrubber, the separation cut diameter is determined from the particle size distribution parameter and the required penetration. A performance cut diameter (dPC) is measured as a function of the varying characteristics of many types of scrubbers. The design process consists of setting the performance cut diameter equal to the separation cut diameter, (dPC = dRC) and then looking in a catalog or handbook for the design parameter of the particular type scrubber of interest. In order to be effective, the process obviously requires a series of extensive measurements on many scrubber types. Calvert et al.3 list performance cut diameter curves for many types of scrubbers. The open literature reports other performance cut diameter curves.9 The technique depends upon an exponential relationship for penetration as a function of aerodynamic diameter for inertial impaction collection equipment:
(
Pt d = exp − Ad Bpa
)
(22.20)
This relationship can be simplified and based on actual particle diameter without introducing too much error for larger particles or where the particle distribution is log normal in terms of physical diameter:
(
Pt d = exp − A p d Bp
)
(22.21)
Packed towers, centrifugal scrubbers, sieve plates, and venturi scrubbers follow the above relationship where B is given in Table 22.4. From Table 22.4, it can be seen that the last three listings are gas-atomized liquid type of wet scrubbers. Performance of these types of scrubbers fit a value of B = 2.0 over a large portion of their operating range. These are scrubbers whose collection mechanism is essentially inertial impaction. Therefore, B = 2.0 is representative of scrubbers operating in the inertial impaction range. With dW/W = the weight fraction of dust in a given size interval, the overall penetration, Pt, of any device on a dust of that type of size distribution will be Pt =
dW
∫ Pt W
(22.22)
Equation 22.22 has been solved by Calvert for a dust which is log-normally distributed with collection efficiency or penetration defined by Equation 22.20. © 2002 by CRC Press LLC
9588ch22 frame Page 336 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.14 Penetration, Pt, vs. the ratio of aerodynamic cut diameter to aerodynamic 50/d , with B(ln σ ) as a parameter. geometric mean particle diameter, d ap apg g
Figure 22.14 is a plot of penetration, Pt vs. the ratio of aerodynamic cut diameter to 50 /d , with B(ln σ ) as a parameter. aerodynamic geometric mean particle diameter, d ap apg g dap50 = “cut diameter” or the aerodynamic particle diameter collected with 50% efficiency dapg = aerodynamic geometric mean particle diameter σg = geometric standard deviation It should be noted that: σg =
d d a 84.13 = apg d apg d a15.87
(22.23)
Figure 22.15 presents the special case where B = 2 with σg as the parameter. Summarizing the design technique, first determine that the particle size distribution by weight fraction is log normal. If the distribution is obtained from a cascade impactor, the particle size will be in aerodynamic dimensions. From the required efficiency η, the penetration, Pt, can be calculated as Pt = 1 – η. The particle distribution will provide the geometric standard deviation σg and the value of the
© 2002 by CRC Press LLC
9588ch22 frame Page 337 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.15 Penetration, Pt, vs. the ratio of aerodynamic cut diameter to aerodynamic 50/d , for the special case where B = 2 and with σ as geometric mean particle diameter, d ap apg g a parameter.
geometric mean particle diameter dapg. For a wet scrubber in which the collection 50 /d ) action is largely dependent upon inertial impaction, B = 2, and the ratio (d ap pg can be found from Figure 22.15 knowing the penetration. The separation cut diameter 50 . is the aerodynamic particle diameter collected with 50% efficiency, thus dRC = d ap The design method simply matches the performance cut diameter to the separation cut diameter. d PC = d RC
(22.24)
Performance cut diameter plots can then be searched to find feasible scrubber types and their process parameters. The following six curves are presented in Appendix A. Figure 22.17 Figure 22.18 Figure 22.19 Figure 22.20 Figure 22.21 Figure 22.22
© 2002 by CRC Press LLC
Vertical countercurrent flow spray towers. Cross-current flow spray towers. Sieve plate column. Impingement plate column. Packed columns. Hydrophobic particles in Venturi scrubber.
9588ch22 frame Page 338 Wednesday, September 5, 2001 10:08 PM
22.9.1 AN EXAMPLE CALCULATION An air stream containing dust must be cleaned to remove 98% of all the particles. The dust is log-normally distributed with σg = 3.0 and dapg = 20 µmA. The dust density is 3 gm/cm3. Pt = 1.00 − 0.98 = 0.02 µmA 50, from Figure 22.15, Determine d ap
50 d ap d = 0.85 apg 50 d ap = 0.085 × 20 − 1.70 µmA 50 d RC = d ap = 1.70 µmA
The performance cut diameter is then dPC = 1.70 µmA. Performance cut diameter curves for various types of wet scrubbers such as shown in Figures 22.17 through 22.22 can now be searched for a suitable scrubber with dPC = 1.70 µmA.
22.9.2 SECOND EXAMPLE PROBLEM A vertical countercurrent spray chamber has a 2.0 m contact zone and operates with a liquid-to-gas ratio of 1.0 l/m3. The average droplet size is 300 µm. The following data was recorded during a test run of the apparatus: Average operating conditions: 80°F, 1.0 atm Gas velocity = 0.60 m/s Inlet loading = 1.5 grains/ft3 Particle density = 2.50 gms/cm3 The particle size distribution was obtained by a cascade impactor. From a logprobability plot of the particle size distribution it was found that The geometric mean diameter, dapg = 9.7 µm The geometric standard deviation, σg = 2.22 Determine the efficiency of the scrubber by the Calvert cut diameter technique. Examining the plots of Figures 22.17 to 22.22, it can be determined that Figure 22.17 for a vertical countercurrent flow spray tower can be used. Tower data: Z = 2.0 m, Q L Q G = 1.0 l m 3 , d d = 300 µm, U G = 0.60 m s © 2002 by CRC Press LLC
9588ch22 frame Page 339 Wednesday, September 5, 2001 10:08 PM
The performance cut diameter can be read from Figure 22.17. d PC = 3.3 µm The separation cut diameter and the cut diameter are therefore 50 d ap = d RC = d PC = 3.3 µm
To find penetration Pt calculate 50 d ap d apg = 3.3 9.7 = 0.34
then from Figure 22.16 at σg = 2.22 Pt = 0.15 or 15.0% Thus the overall efficiency for this scrubber would be 85.0%. 3
Scrubber power, hp/1,000 ft /min 5
0.4 0.5
1.0
2
3
4
5
10
20
30
4
2
5
3
1a
Cut diameter, µmA
2
1b
1.0
3a
4
0.5 0.4 0.3
0.2
3b
Notes: 3b. Same as 3a except 0.004-in.-dia. fibers. 1a. Sieve-plate column with foam density of 0.4 g/cm3 and 0.2-in. hole dia. The number 3c. Same as 3a except 0.002-in.-dia. Fibers. of plates does not affect the relationship much. (Experimental data and mathematical 4. Gas-atomized spray. (Experimental data from large venturis, orifices, and rod-type model.) units, plus mathematical model.) 1b. Same as 1a except 0.125-in. hole dia. 2. Packed column with 1-in. rings or saddles. Packing depth does not affect the relationship much. (Experimental data and mathematical model.)
3c
5. Mobile bed with 1 to 3 stages of fluidized hollow plastic spheres. (Experimental data from pilot-plant and large-scale power-plant scrubbers.)
3a. Fibrous packed bed with 0.012-in-dia. Fiber - any depth. (Experimental data and mathematical model.)
0.1 1.0
2
3
4
5
10
20
30
40
50
100
Gas-phase pressure drop, in. H 2O
FIGURE 22.16 Cut/power relationship for several scrubber types. (With permission from Calvert, S., Chem. Eng., 29, 54–68, 1977.) © 2002 by CRC Press LLC
9588ch22 frame Page 340 Wednesday, September 5, 2001 10:08 PM
22.10 THE CUT-POWER RELATIONSHIP Calvert10 has related the performance cut diameter to gas phase pressure drop or power input to the scrubber. This makes a simple relationship that describes the performance on many scrubbers. Performance tests on many scrubbers combined with Calvert’s mathematical model have led to the refined cut/power relationship for several types of scrubbers shown in Figure 22.16.
REFERENCES 1. Crocker, B. B. and Schnelle, Jr., K. B., Air pollution control for stationary sources, in Environmental Analysis and Remediation, Meyers, R. A. (Ed.), John Wiley & Sons, Inc., New York, 1998, pp. 151–213. 2. Hesketh, H. E., Atomization and cloud behavior in wet scrubbers, US-USSR Symp. Control of Fine Particulate Emissions (1), 15, 1974. 3. Calvert, S., Goldshmidt, F., Leith, D., and Mehta, D., Scrubber Handbook, NTIS Publication PB-213016 and PP-213017, July–August 1972. 4. Porter, H. F., Schurr, G. A., Wells, D. F., and Semrau, K. T., in Chemical Engineers’ Handbook, 6th ed., McGraw-Hill Book Co., New York, 1984, pp. 20–77 to 20–110. 5. Sargent, G. D., Dust collection equipment, Chem. Eng., 76, 130–150, 1969. 6. Celenza, G. F., Designing air pollution control systems, Chem. Eng. Prog., 66(11), 31, 1970. 7. Semrau, K. T., Correlation of dust scrubber efficiency, J. Air Poll. Contr. Technol. Assoc., 10(3), 200, 1960. 8. Semrau, K. T., Dust scrubber design — a critique on the state of the art, J. Air Poll. Contr. Technol. Assoc., 13(12), 587, 1963. 9. Calvert, S., Engineering design of fine particle scrubbers, J. Air Poll. Contr. Assoc., 24(10), 929, 1974. 10. Calvert, S., How to choose a particulate scrubber, Chem. Eng., 54–68, August 29, 1977.
ADDITIONAL REFERENCES Licht, W., Air Pollution Control Engineering, Basic Calculations for Particulate Collection, 2nd ed., Marcel Dekker, Inc., New York, 1988. Loftus, P. J., Stickler, D. B., and Diehl, R. C., A confined vortex scrubber for fine particulate removal from flue gases, Environ. Prog., 11, 27–32, 1992. Blackwood, T. R., An evaluation of fine particle wet scrubbers, Environ. Prog., 7, 71–75, 1988.
© 2002 by CRC Press LLC
9588ch22 frame Page 341 Wednesday, September 5, 2001 10:08 PM
APPENDIX A: CALVERT PERFORMANCE CUT DIAMETER DATA 100
100
3
1
10
dPC
dPC
2
QL/QG = 0.5 L/m uG = 0.6 m/sec 1 0.1
2
10
3
QL/QG = 0.5 L/m 3 uG = 0.9 m/sec
1.0
1 0.1
10
1.0
Z(m) (A) 100 3
QL/QG = 1 L/m uG = 0.6 m/sec
3
2
dPC
2
dPC
10
Z(m) (B)
100
10
3
1
1 0.1
1.0
3
10
1 0.1
10
1.0
Z(m) (D)
Z(m) (C) CURVE NO. DROP DIA, µm
1
2
200
500
FIGURE 22.17 Vertical countercurrent flow spray towers.
© 2002 by CRC Press LLC
QL/QG = 1 L/m 3 uG = 0.9 m/sec
3 1,000
10
9588ch22 frame Page 342 Wednesday, September 5, 2001 10:08 PM
100
dPC
1
2
3
10
3
QL/QG = 0.5 L/m
1 0.1
1.0
10
h(m) CURVE NO. dD, µm
1
2
200
500
3 1,000
100
dPC
1
2
3
10
QL/QG = 1 L/m3
1 0.1
1.0
h(m)
FIGURE 22.18 Cross-current flow spray towers.
© 2002 by CRC Press LLC
10
9588ch22 frame Page 343 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.19 Sieve plate column.
FIGURE 22.20 Impingement plate column. © 2002 by CRC Press LLC
9588ch22 frame Page 344 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.21 Packed columns, DC = packing diameter, cm; = bed porosity.
© 2002 by CRC Press LLC
9588ch22 frame Page 345 Wednesday, September 5, 2001 10:08 PM
FIGURE 22.22 Hydrophobic particles In Venturi scrubber.
© 2002 by CRC Press LLC
9588ch23 frame Page 347 Wednesday, September 5, 2001 10:10 PM
23
Filtration and Baghouses
23.1 INTRODUCTION “Baghouse” is a common term for the collection device that uses fabric bags to filter particulate out of a gas stream. The filter bags are mounted on a tubesheet and enclosed in a sheet-metal housing. The housing is visible and the single word “baghouse” is easy to pronounce, but “filtration” is more technically descriptive of the process. Frequently, the term “fabric filtration” is used, partly to be technically accurate and partly to distinguish the technology from water filtration. While filtration of particles from air commonly employs fabric bags as the filter media, porous ceramic candles and paper cartridges also are used to clean gas streams. Finally, a fabric filter “baghouse” system includes the bag cleaning system, dust collection hoppers, and dust removal system, so the total system involves more than just filtration. It must be understood that the mechanism that achieves filtration of small particles from a gas stream is not simple sieving. The spacing between fabric threads may be on the order of 50 to 75 microns, yet particles of 1 micron diameter and less are collected efficiently. Indeed, the primary collection mechanisms include impaction, interception, and diffusion, as discussed in Chapter 19. Initially, on a clean filter before any dust accumulates, the fabric threads and fibers are stationary targets for the particles. As soon as a layer of dust (dust cake) accumulates, however, the stationary particles in the dust cake become targets for the particles in the gas stream. This explains an interesting phenomenon about fabric filtration: emissions from new, clean bags tend to be higher than from used bags. Used bags have been “seasoned,” that is, a number of particles have been lodged in the fabric (cleaning is not perfect and there is always some residual dust after cleaning) that serve as small targets for collection. These embedded particles also tend to fill the gaps between threads, reducing the opening size and increasing the probability for collection by impaction, interception, and diffusion. Filtration is effective at removing submicron particles because of the diffusion mechanism, especially after a dust cake has been established. The space between target fibers is small, so particles do not have to diffuse a great distance to be collected. And after the dust cake is established, the space between target particles is very small, and the gas path through the dust layer becomes rather long and tortuous.
© 2002 by CRC Press LLC
9588ch23 frame Page 348 Wednesday, September 5, 2001 10:10 PM
23.2 DESIGN ISSUES The basic design parameters for a fabric filter baghouse include: • Cleaning mechanism – Shake/deflate – Reverse air – Pulse jet • Size – Air-to-cloth ratio – Can velocity • Pressure drop – Fan power – Vacuum/pressure rating • Fabric – Material – Weave • Bag life – Cleaning frequency – Gas composition – Inlet design
23.3 CLEANING MECHANISMS As dust collects on the fabric, a dust layer builds up, which increases the pressure drop requirement to move gas through the dust cake. Eventually the dust layer becomes so thick that the pressure drop requirement is exceeded and the dust cake needs to be removed. Three types of dust cake removal (cleaning) systems are used.
23.3.1 SHAKE/DEFLATE The oldest cleaning mechanism is to stop the gas flow through the fabric bags and shake the bags to knock off the dust cake. As shown in Figure 23.1, the dust cake typically collects on the inside of the bags as the gas flows upward through a cell plate or tubesheet near the bottom of the housing and through the bags. The bags are suspended on a rod or frame and the open end at the bottom is clamped onto a thimble on the tubesheet. Cleaning is accomplished by moving the upper support frame, typically back and forth, up and down, or, if the driver is mounted to an eccentric rod, in a sinusoidal motion. The duration typically is from 30 s to a few minutes, may have a frequency of several times per second, an amplitude of a fraction of an inch to a few inches, and an acceleration of 1 to 10 g. Typically the motion is imparted by an electric motor, but may be done using a hand crank on a small baghouse that does not require frequent cleaning. Stopping the gas flow, or deflating the bags, greatly increases the effectiveness of cleaning. If the process gas flow cannot be interrupted, multiple parallel compartments are required so that one can be isolated. Many shaker baghouses are used in © 2002 by CRC Press LLC
9588ch23 frame Page 349 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.1 Shaker baghouse.
batch applications or noncritical flow applications where both the process and the baghouse designs are kept very simple intentionally. The dust is allowed to fall to hoppers in the bottom of the baghouse before being immediately re-entrained and re-collected. Also, the bag is looser and moving the top of a bag imparts more motion to the rest of the bag when it does not have pressure on the inside of the bag.
23.3.2 REVERSE AIR Reverse air cleaning involves gently blowing clean gas backwards through the fabric bag to dislodge the dust cake. A schematic of the required baghouse arrangement is shown in Figure 23.2. The system requires multiple parallel modules that can be isolated, which typically is accomplished using “poppet” valves, or large disks mounted on a shaft that moves up and down, much like a valve in a car engine. Like the shake/deflate configuration described above, gas flow enters the bag from the bottom and dust collects on the inside of the bag. To clean, a portion of the cleaned gas is withdrawn from the clean-side manifold using a fan. The reverse air valve opens, and low-pressure clean gas is gently blown backwards through the fabric. The reverse air fan develops a head of only a few inches of water pressure. The entire cleaning process is sequenced and takes a couple of minutes, including time to close the main discharge valve and let the bag collapse, then open the reverse air valve for 10 to 30 s, close the reverse air valve and let the dust settle, and finally open the main gas discharge valve. © 2002 by CRC Press LLC
9588ch23 frame Page 350 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.2 Reverse air cleaning.
Blowing gas backwards through the bag from the outside to the inside would cause a 20 to 30 ft long bag to collapse flat. This would not be conducive to allowing a dust cake to drop. To prevent complete collapse, reverse air bags have stiff anticollapse rings sewn into them at about 3 to 4 ft spacing. The partial collapse of the bag flexes the bag, which dislodges the dust cake. The particles are not “blown off” the bag by the gentle reverse air flow. A primary advantage of reverse air cleaning is that very large bags can be used. The bags can be 12 or more inches in diameter and 30 to 40 ft long. Thus, a very large reverse air baghouse can have a smaller footprint and fewer bags than a pulse jet baghouse, which is described in the next section. Several very large reverse air baghouses at a coal-fired power plant are shown in Figure 23.3. Another advantage of reverse air cleaning is the potential for increased bag life from the gentle cleaning action. The gentle action minimizes abrasion, which often is the limiting factor for bag life. However, there are several factors that could limit bag life, including buildup of residual dust cake after cleaning, in which case the more vigorous cleaning action of pulse jet could result in longer bag life.
23.3.3 PULSE JET (HIGH PRESSURE) A vigorous and very common cleaning mechanism is high-pressure pulse jet. Highpressure pulse jet cleaning uses a very short blast of compressed air (70 to 100 psi) to deform the bag and dislodge the dust cake. The common term is simply “pulse
© 2002 by CRC Press LLC
9588ch23 frame Page 351 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.3 Large reverse air baghouse.
jet,” but there are baghouse designs, that also are called “pulse jet,” that employ air at 7 to 14 psi and are sufficiently different to warrant a separate discussion in the next section. A schematic of a pulse jet baghouse is shown in Figure 23.4. Note that in this configuration, the bags are hung from a tubesheet located near the top of the housing, gas flow is from the outside to the inside of the bag, and dust is collected on the outside. To keep the bag from collapsing during normal operation, wire cages are used on the inside of the bags. A compressed air pipe is located over each row of bags, and there is a small hole in the pipe over each bag. A diaphragm valve with a separate solenoid valve operator admits compressed air into the blowpipe, so bags are cleaned one row at a time. A venturi is used at the top of each cage to direct the pulse of compressed air. The compressed air pulse duration is very short, being about 100 to 200 msc. The cleaning action often is described as a shock wave or an air bubble that travels down the length of the bag. While conceptually descriptive, this may not be technically accurate. In any case, the pulse distends the bag and dislodges the dust cake. Pulse jet cleaning can be done on line or off line. The obvious advantage to online cleaning is that the gas flow is not interrupted. With small, one-compartment baghouses, this is critical. Disadvantages of on-line cleaning are that much of the dust is likely to be re-entrained and re-deposited on the bags before falling to the hoppers, and the bags tend to snap back harshly onto the cages at the end of the pulse, aided by the normal gas flow. This can cause excessive bag wear. Cages typically are constructed with either 10 or 20 vertical wires. 20-wire cages are more expensive because they have almost twice the wire as 10-wire cages (both require wire circles to hold their shape) and they require more spot welding. The advantage is that with less space between supporting wires, bag flexing is minimized, resulting in less abrasion.
© 2002 by CRC Press LLC
9588ch23 frame Page 352 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.4 Schematic of pulse-jet baghouse.
23.3.4 PULSE JET (LOW PRESSURE) Some baghouses use air at 7 to 14 psi for cleaning. Although they are called “pulse jet,” the action is different from the high-pressure pulse described above. The bags are distended during cleaning, which dislodges the dust cake. But the pulse of air is longer and less vigorous than a high-pressure pulse. One design uses a single blow pipe, fixed on one end, that travels in a circle over the bags. When a cleaning cycle is triggered, the blow pipe makes one revolution. Other baghouse designs use intermediate air pressure for cleaning. The air supply is around 40 psi.
23.3.5 SONIC HORNS Sonic or acoustic horns sometimes are used to create low-frequency (150 to 200 Hertz, a very deep bass) sound-wave-induced vibrations to promote cleaning. They are powered by compressed air, and generate about an average of 120 to 140 decibels in a compartment. Sound waves create fluctuations in the static pressure that cause vibrations, which help to loosen particulate deposits. Typically, horns are used to assist reverse-air, but can be used as the sole cleaning mechanism in applications © 2002 by CRC Press LLC
9588ch23 frame Page 353 Wednesday, September 5, 2001 10:10 PM
where the dust cake releases easily.1 Sonic horns also are used in baghouse hoppers to prevent accumulated dust from sticking to the sides and bridging across the hopper.
23.4 FABRIC PROPERTIES Key performance properties for fabric filtration media selection include maximum allowable temperature, chemical resistance, abrasion resistance, weave, weight, and strength. Some of these properties are listed in Table 23.1. Temperature is a key flue gas property that deserves first consideration in bag material selection. The choice of fabrics that withstand temperatures above 400ºF is limited and high-temperature fabrics are expensive. Cooling often is used to reduce the baghouse temperature to an operable and economic value, although each method of cooling has its disadvantages. Adding cold air increases the volume of gas that must be treated by the baghouse and moved by fans. Air-to-gas heat exchangers are expensive. And spraying water into the flue gas must be done carefully to avoid wetting duct walls and causing local corrosion. When the operating temperature exceeds 500ºF, ceramic fabrics or candles can be used, although they are very expensive. Flue gas chemistry is the second key flue gas property that demands consideration in fabric selection. Many applications are in acidic or alkaline environments, and flue gas moisture can promote chemical attack as well as affect dust cake cohesivity.
TABLE 23.1 Filter Material Properties Recommended Max
Material
Operating
Excursion
Temp (°F)
Temp (°F)
Chemical Resistance Acid
Base
Abrasion Resistance
Cost (per 8-ft bag)
180 200 200 200 275 260 375 375 450 500 900
200 230 250 200 300 285 400 400 500 550 1050
Poor Good Poor Excellent Good Good Fair Excellent Excellent Good Good
Good Poor Good Excellent Fair Fair Good Excellent Excellent Good Good
Good Fair Excellent Excellent Excellent Good Excellent Excellent Fair Fair Fair
$8 — — $8 $9 $13 $22 — $26 $24 $150
1650
1830
—
—
—
$1000a
Cotton Wool Nylon Polypropylene Polyester Acrylic Nomex® Ryton® Teflon® Fiberglass Coated highpurity silica Ceramic candle a
60 mm diameter × 1.5 m.
© 2002 by CRC Press LLC
9588ch23 frame Page 354 Wednesday, September 5, 2001 10:10 PM
23.4.1 WOVEN BAGS Once the material is chosen, the next key selection parameters are the weave and the weight. Woven fabric threads include the warp, which is the thread that runs lengthwise in woven goods, and the fill, which is the thread that interlaces the warp. There are many weave patterns, including plain, twill, and sateen. Selection of the weave pattern is of minor importance compared to the basic choice of woven or felted fabric. Woven fabrics are stronger than felted and can be expected to last longer. Typically, shaker and reverse air baghouses employ woven fabrics. Pulse jet baghouse employ both woven and felted fabrics.
23.4.2 FELTED FABRIC Felted fabrics have a woven base scrim to give structure to the cloth, with the scrim filled in with random needle-punched fibers. The felting process is economical because the felting machines can be run at high speed. From a filtration point of view, the random individual fibers make better targets for the collection mechanisms of impaction and interception, because individual fibers have smaller diameters than woven threads. Felted fabrics also may be thicker than woven fabrics for the same weight, so more time is available for diffusion to be an effective cleaning mechanism. Therefore, new felted fabric can produce higher particulate removal efficiency than new woven fabrics. This advantage does not last long, however. As soon as a dust cake builds up, it becomes the filtering media while the fabric serves merely to support the dust cake. After cleaning to remove the dust cake, some residual particles remain on the fabric, so that older bags never lose their dust cake entirely. This is the reason for the interesting observation that “seasoned” bags often exhibit higher collection efficiency than new bags. With pulse jet cleaning, the vigorous, high-energy pulse can cause the threads in woven fabrics to separate slightly, resulting in increased bleed-through emissions. This is why felted fabrics sometimes are specified for pulse jet applications, even though the lower strength of felted fabrics might shorten bag life.
23.4.3 SURFACE TREATMENT Surface treatment and finishes commonly are used to modify fabric properties. Fiberglass has become a popular bag material despite its relatively low chemical and abrasion resistance because these weaknesses are overcome with treatment. Silicone, graphite, and fluorocarbon, used alone or in combination, provide lubrication to resist abrasion and protection from acid attack. A new, inorganic, hightemperature coating on high purity silica fibers allows use of woven bags in pulsejet applications up to 900°F.
23.4.4 WEIGHT Finally, the fabric weight is chosen. It is measured as the weight of one square yard of fabric, or as the denier, which is the weight per unit length. Common fabric weights range from 5 oz to 26 oz. More fabric adds strength to the fabric and © 2002 by CRC Press LLC
9588ch23 frame Page 355 Wednesday, September 5, 2001 10:10 PM
increases the target area for particulate collection. Of course, higher fabric density costs more, and adds to the pressure drop of the cloth.
23.4.5 MEMBRANE FABRICS A unique material, which might be considered to be a surface treatment but changes the concept of fabric filtration sufficiently to warrant a separate discussion, is an expanded polytetrafluoroethylene (PTFE) membrane that is applied to one side of conventional material. Membrane-coated fabrics are commonly known as GoreTex®, although the patent for the material has expired and other manufacturers now produce it. The PTFE membrane has extremely fine diameter fibers that are small enough and spaced closely enough together that they act as very efficient primary targets for the impaction and interception collection mechanisms. It is a very thin membrane, so pressure drop is low. Since the membrane serves as the primary target for dust collection, a dust cake is not needed to provide good collection efficiency. And residual dust cake buildup is minimized because dust cake release from PTFE is excellent and little particulate penetrates the membrane. Therefore, membrane bags can operate efficiently with very low pressure drop. The only two disadvantages of this unique material are that it is expensive, and it cannot be used in applications that contain even small amounts of hydrocarbons in the gas stream. The base material serves as a support for the membrane, not as the target for dust collection. Since PTFE has higher temperature resistance than common bag materials and excellent chemical resistance, the temperature and chemical resistance of the base material limits the material selection. The membrane can be used with most common base materials, including fiberglass.
23.4.6 CATALYTIC MEMBRANES A new feature available in fabric filter bags is the addition of catalyst to the felted support fabric of PTFE membrane material. This transforms the filter bag into a multifunctional reactor where the membrane provides high efficiency particulate removal and the catalytic support fabric promotes gas phase reactions. This technology is being applied to reduce dioxin/furan emissions from incinerators, metals plants, and crematoria by more than 99%.2
23.4.7 PLEATED CARTRIDGES Pleated cartridge filter elements are becoming popular for many applications. Their advantage is much higher collection area per linear foot of element. This allows a more compact baghouse for an original design, or allows the air-to-cloth ratio of an older pulse-jet baghouse retrofit with cartridges to be decreased. Cartridge filter elements typically are shorter than bags, but the increased area from the pleats more than makes up for the difference in length. Cartridges originally were available in cellulose or paper, like air filter for a car, for low-temperature nuisance dust applications. They are now available in polyester and Nomex®, and can be provided with a PTFE membrane. To make rigid pleats that hold their shape, the materials must be constructed differently from fabric for © 2002 by CRC Press LLC
9588ch23 frame Page 356 Wednesday, September 5, 2001 10:10 PM
flexible bags. Polyester can be spun-bonded, and Nomex® is impregnated with a resin.
23.4.8 CERAMIC CANDLES Rigid filter elements that are made in the shape of cylinders are called “candles.” Conceptually, there is no difference in the filtering mechanism between rigid candles and fabric; candles just don’t flex when pulsed. The porous media provides the initial targets for particle collection until a dust cake forms; then the dust cake becomes the primary medium for collection by impaction, interception, and diffusion. Candles are made of ceramic materials, either in a monolithic structure or as composites that contain ceramic fibers. Ceramic candles can be used in very high temperature applications from 1650 to 2000°F. They are used in extreme services such as pressurized fluid bed combustors, combined cycle combustors, coal gasification, and incinerators where they are exposed to high temperature and pressure as well as alkali, sulfur, and water vapor. Typical monolithic candles may be clay-bonded silicon carbide, silicon nitride, or aluminum oxide particles. In high-temperature applications with alkaline ash, silicon carbide and silicon nitride may oxidize and degrade slowly, while oxide materials will not be further oxidized. A concern with rigid candles is susceptibility to thermal and mechanical shock that can result in a complete failure if cracked. In monolithic materials, the combination of a high elastic modulus and high coefficient of thermal expansion can result in excess thermal stresses. Candles composed of ceramic fiber composites resist breaking when cracked, which is a significant advantage for this design. One type of composite ceramic fiber material is constructed of continuous ceramic fibers for structural reinforcement and discontinuous ceramic fibers for filtration. The filtration fibers have a small mean diameter of 3.5 microns, which aids in efficient capture. The structural and filtration fibers are bonded with a chemical binder that converts to a stable bond phase with heat treatment.3
23.5 BAGHOUSE SIZE 23.5.1 AIR-TO-CLOTH RATIO The air-to-cloth ratio is simply the gas flow rate divided by the fabric collection area. Volume per unit time divided by area reduces to units of length per unit time, so the air-to-cloth ratio also is called the superficial velocity. A high air-to-cloth ratio requires a smaller baghouse, which is less expensive. If the air-to-cloth ratio is too high, the baghouse may experience difficulty in maintaining the desired pressure drop despite frequent cleaning. A low air-to-cloth ratio provides a large collection area, so dust cake buildup and pressure drop increase at a lower rate than a high air-to-cloth ratio. When cleanon-demand cleaning is used, the overall baghouse pressure drop is set by the pressure drop triggers, so to say that low air-to-cloth ratio reduces pressure drop can be misleading. Rather, a thicker dust cake can be accumulated and time between cleaning is longer with a low air-to-cloth ratio. © 2002 by CRC Press LLC
9588ch23 frame Page 357 Wednesday, September 5, 2001 10:10 PM
Because air-to-cloth ratio is related to the rate of pressure drop increase, the optimum ratio depends upon the dust permeability (particle size and cohesivity) and dust loading. The long-term rate of blinding and desired bag life also are factors to be considered. Because these factors are difficult to quantify, reasonable ratios generally are chosen based on experience. There are several tables of typical pulsejet air-to-cloth ratios for specific applications available in the literature; however, many of these tables are dated and will not be repeated here to prevent their use in light of experience. Users’ experience with a large number of problem baghouses is moving recommended design to lower air-to-cloth ratios as the tradeoffs between initial investment, maintenance cost, troubleshooting cost, and capacity for future growth are weighed. Typical air-to-cloth ratios for shaker and reverse air baghouses are 2.0 to 2.5 cfm/ft2. Typical ratios for pulse-jet baghouses range from 3 to 10 cfm/ft2, with recent design practice being close to 4.0 cfm/ft2 and lower.
23.5.2 CAN VELOCITY Can velocity is an important sizing criteria for on-line pulse-jet cleaning. As dust is cleaned from the bags, gravity will cause it to fall toward the hopper. But when cleaning on-line, gas flow is interrupted only momentarily by the pulse. Typical configuration is upward flow with the gas brought in at the bottom. To allow the dust some chance to settle, the upward velocity should be limited. The upward velocity is described as the “can velocity,” which is the air-flow rate divided by the horizontal cross-sectional area of the baghouse less the cross-sectional area of the bags. The can velocity should not exceed about 2.5 to 3.5 ft/s, with the lower value more suitable for fine dust that does not settle easily.
23.6 PRESSURE DROP Because flow between fibers of fabric cloth and particles in the dust cake is laminar, pressure drop across the filter media will be directly proportional to gas flow, as shown in Equation 23.1. ∆P = SV
(23.1)
where S = filter drag, in. H2O-min/ft V = superficial velocity Note that the superficial velocity is the actual gas flow divided by the filter area; it is not the actual velocity between fibers or dust particles. By this definition, it is frequently called the gas-to-cloth or air-to-cloth ratio, which has units of volume per time divided by area and reduces to distance per unit time. Pressure drop across the filter media, which is commonly measured with a local differential pressure gauge for each compartment or module, does not include the pressure drop associated with the inlet and outlet ductwork, which commonly is measured and transmitted to a recorder and is often used to trigger cleaning. Because © 2002 by CRC Press LLC
9588ch23 frame Page 358 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.5 Overall pressure drop variation with time.
flow in the ductwork is turbulent, the duct pressure drop varies with the square of the flow. Typically, however, the duct pressure drop is small compared to the drop across the filter media. The largest contributor to pressure drop typically is the dust cake, although residual pressure drop across plugged fabric may be larger. As illustrated in Figure 23.5, there will be fluctuations in pressure drop as the bags are cleaned and as the gas flow varies. To eliminate gas flow as a variable, the filter drag, S, is defined as: S=
∆P V
(23.2)
When plotted as a function of dust loading on the fabric, drag increases linearly with dust loading, as shown in Figure 23.6. Collecting data for a given type of dust with a given fabric as the filter media provides values for clean fabric and dust cake coefficients in the linear drag equation. Drag becomes a useful approach to determine the air-to-cloth ratio required to meet a pressure drop limitation between reasonable cleaning cycle intervals for the dust/fabric combination for which data are available. S = K e + Ks W where S = Ke = Ks = W=
(23.3)
filter drag, in. H2O-min/ft clean cloth filter drag coefficient, in. H2O-min/ft dust cake coefficient, in. H2O-min/ft dust loading, lbm/ft2
Plotting drag data as a function of dust loading after cleaning also provides insight into cleaning effectiveness. Drag and residual dust loading remain high after poor cleaning. © 2002 by CRC Press LLC
9588ch23 frame Page 359 Wednesday, September 5, 2001 10:10 PM
FIGURE 23.6 Determine ke and ks from data.
Particle-size distribution has a dramatic effect on the dust cake coefficient. Small particles pack closely together and leave very small openings for gas flow, resulting in high pressure drop. Dust cohesivity also affects the resistance of gas flow through the dust cake. Particles that have high cohesivity stick to each other and tend to remain on the surface of the fabric, forming a porous dust cake. Low-cohesivity particles can work into the fabric interstices and blind the bag. Particle size, shape, and moisture content can greatly affect the cohesivity of the dust cake. Additives can condition dust cake properties to improve fabric filter performance. Ammonia and SO3 are two gaseous additives that are used to change the cohesive properties of some dusts, but they have the disadvantage of having health, safety, and hazardous waste issues associated with them. Also, SO3 can aggravate acid attack of the fabric. Alternatively, proprietary conditioning agents are being developed to modify dust cake properties and improve fabric filter performance4.
23.7 BAG LIFE 23.7.1 FAILURE MODES Bag life can be a significant factor in the operating cost of a baghouse. Although 2 to 5 years is a typical range for bag life, it may be much shorter or longer, depending on the application and the conditions. Common modes of bag failure include: • Blinding by particles embedded in the fabric • Blinding by sticky compounds • Holes from abrasion © 2002 by CRC Press LLC
9588ch23 frame Page 360 Wednesday, September 5, 2001 10:10 PM
• Holes from weakened fibers that suffered chemical attack or high temperature excursions • Burn holes from hot material • Broken seams In some cases, sticky compounds that blind bags are soluble in water or solvent and can be removed by laundering the bags.
23.7.2 INLET DESIGN The inlet design configuration can have a direct bearing on bag life because of abrasion from high velocity dust impinging on the bags. It also can affect dust reentrainment from the hopper. The inlet typically is near, or directed toward, the bottom of the baghouse because bags fill most of the compartment and the highvelocity inlet cannot be directed straight at the bags. A simple baffle plate often is used. However, a baffle plate will not distribute the flow evenly over the horizontal cross-section of the baghouse by the time it reaches the bags. Dust entrained in the high velocity streamlines can abrade the bags, especially at the bottom. Some vendors offer inlet designs that diffuse the inlet gas flow. The additional expense may warrant the benefits of reduced entrainment and reduced abrasion.
23.7.3 STARTUP SEASONING It is common practice for baghouse vendors to specify an initial coating of a largediameter, multidimensional dust to “season” the bags. The intent is to avoid filling the interstices between the fibers with fine dust that blinds the bags at the very beginning of their life, and to create an initial dust layer that has good permeability. Larger particles may embed within the fabric also; indeed, a portion of the initial seasoning particulate should stay on the bags for it to be of benefit. Large particles do not blind the fabric completely as small particles are able to do. There is some question as to the necessity and the lasting benefit of pre-seasoning, but that depends largely on the application. It could be very beneficial in applications where very fine particles or fume could embed in the fibers.
REFERENCES 1. Schimmoller, B. K., Tuning in to acoustic cleaning, Power Eng., 103(107), 19, 1999. 2. Plinke, M. et al., Catalytic filtration – dioxin destruction in a filter bag, in Recent Developments in Air Pollution Control, Topical Conf. Proc. AIChE Spring National Mtg., Atlanta, 167, 2000. 3. Wagner, R. A., Ceramic composite hot-gas filter development, presented at Symp. on High-Temperature Particulate Cleanup, Birmingham, AL, April 20–23, 1998. 4. Bustard, C. J. et al., Demonstration of novel additives for improved fabric filter performance, presented at EPRI/DOE Int. Conf. Managing Hazardous and Particulate Air Pollutants, Toronto, August 15–18, 1995.
© 2002 by CRC Press LLC
9588ch24 frame Page 361 Wednesday, September 5, 2001 10:11 PM
24
Electrostatic Precipitators
24.1 EARLY DEVELOPMENT The phenomena of electrostatic attraction amuses children who like to stick balloons to their heads. That opposite charges attract and like charges repel is a basic law of physics. It was noted as early as 600 B.C. that small fibers would be attracted by a piece of amber after it had been rubbed. Modern knowledge of electrostatics was developed throughout the last four hundred years, including the work of Benjamin Franklin on the effect of point conductors in drawing electric currents. The first demonstrations of electrostatic precipitation to remove aerosols from a gas were conducted in the early 1800s with fog and tobacco smoke. The first commercial electrostatic precipitator (ESP) was developed by Sir Oliver Lodge and his colleagues, Walker and Hutchings, for a lead smelter in North Wales in 1885. Unfortunately, this application was unsuccessful because of problems with the high-voltage power supply and the high resistivity of the lead oxide fume. As will be discussed in this chapter, resistivity is an extremely important factor affecting ESP performance. In the U.S., Dr. Frederick Cottrell, professor of chemistry at the University of California at Berkeley, and his colleagues developed and improved the technology for industrial application. Cottrell established the nonprofit Cottrell Research Corporation, which supported the experimental studies that formed the fundamental basis of precipitator technology. The technology was applied successfully to control sulfuric acid mist in precious metal recovery kettles. Cottrell installed the next commercial system at a lead smelter. Although the high resistivity of the dust again made it a difficult application, the high-voltage power supply issues were resolved sufficiently well so that the ESPs could operate at about 80 to 90% removal efficiency. Within a few years, ESPs were being installed in Portland cement plants, pulp and paper mills, and blast furnaces. The first installation on a coal-fired boiler was at Detroit Edison Company’s Trenton Channel Station in 1924. Eventually, ESPs were specified for most coal-fired boilers until there were more than 1300 installations servicing about 95% of the coal-fired boiler applications.
24.2 BASIC THEORY An ESP controls particulate emissions by: (1) charging the particles, (2) applying an electric field to move the particles out of the gas stream, then (3) removing the collected dust. Particles are charged by gas ions that are formed by corona discharge from the electrodes. The ions become attached to the particles, thus providing the charge.
© 2002 by CRC Press LLC
9588ch24 frame Page 362 Wednesday, September 5, 2001 10:11 PM
FIGURE 24.1 Tubular collection electrode. (Courtesy of Geoenergy International, Inc.)
In a typical ESP, vertical wires are used as the negative discharge electrode between vertical, flat, grounded plates. The dirty gas stream passes horizontally between the plates and a dust layer of particulate collects on the plates. The typical spacing between the discharge electrode and the collector plate is 4 to 6 in. The dust layer is removed from the plates by “rapping,” or in the case of a wet ESP, by washing with water. An alternative to the plate and wire design is the tube and wire design, in which the discharge electrode wire is fixed in the center of a vertical tubular collection electrode. In this configuration, the gas flow is parallel to the discharge electrode. This configuration, shown in Figure 24.1, is common for wet ESP.
24.2.1 CORONA FORMATION An electrical potential of about 4000 volts/cm is applied between the wires (discharge electrodes) and collecting plates of the ESP. In most cases, the wires are charged at 20 to 100 kV below ground potential, with 40 to 50 kV being typical. For cleaning indoor air, the wires can be charged positively to avoid excessive ozone formation. However, the negative corona is more stable than the positive corona, which tends to be sporadic and cause sparkover at lower voltages, so negative corona is used in the large majority of industrial ESP. In the intense electric field near the wire, the gas breaks down electrically, producing a glow discharge or “corona” without sparkover, as depicted in Figure 24.2. In a negative corona, ionized molecules are formed from the corona glow caused by the high electrical gradient around the discharge wire. The space outside the corona is filled with a dense cloud of negative ions. The dust particles will collide with some of the ions giving them a negative charge. These charged particles will be driven by the electric field toward the plates where they are collected.
© 2002 by CRC Press LLC
9588ch24 frame Page 363 Wednesday, September 5, 2001 10:11 PM
FIGURE 24.2 Corona formation — plan view plate and wire configuration.
FIGURE 24.3 Particle charging.
24.2.2 PARTICLE CHARGING As particles move through the electric field they acquire an electrostatic charge by two mechanisms, bombardment charging and diffusion charging, as illustrated in Figure 24.3. Both types of particle charging act simultaneously, but bombardment charging is of greater importance for larger particles and diffusion charging is more important for submicron particles. The magnitude of the charging for both mechanisms is lowest for particles in the size range of 0.1 to 1 microns, therefore, the minimum collection efficiency will occur for this size range. However, a well designed ESP will be capable of collecting greater than 90% of even these difficult to collect particles.
© 2002 by CRC Press LLC
9588ch24 frame Page 364 Wednesday, September 5, 2001 10:11 PM
Bombardment charging is of primary importance for particles greater than 1 micron. Ions and electrons move along the lines of force between the electrodes normal to the direction of flow of particles in the gas stream. Some of the ions and electrons are intercepted by uncharged particles, and the particles become charged. Because the particles are now charged, ions of like charge are now repulsed by the particle, thus reducing the rate of charging. After a time, the charge on the particles will reach a maximum that is proportional to the square of the particle diameter. Because extremely small particles (less than 0.1 micron) have an erratic path in the gas stream due to Brownian motion, they can acquire a significant charge by diffusion charging. Thus, an ESP can be an efficient collection device for submicron particles. However, these particles represent only a small fraction of the mass of dust entering an ESP, so they are often neglected in studies of ESP performance, even though they can be of great importance to particulate emissions.
24.2.3 PARTICLE MIGRATION Most charged particles migrate under the influence of the electric field towards the plate, although a few particles in the vicinity of corona discharge will migrate towards the wire. The presence of charged particles in the gas space affects the overall electric field. Near the plate, the concentration of charged particles will be high, and interparticle interferences can occur. Finally, particles will collect as a dust layer on the plates, and a portion of their charge may be transferred to the collecting electrode. Ideally, charged particles will migrate to the plate before exiting the ESP, as illustrated in Figure 24.4, and will stick to the dust layer on the collecting electrode until it is cleaned. When the plate is rapped, the dust layer should fall as a sheet into dust collection hoppers without re-entraining into the gas stream.
FIGURE 24.4 Migration velocity vs. treatment time.
© 2002 by CRC Press LLC
9588ch24 frame Page 365 Wednesday, September 5, 2001 10:11 PM
The velocity at which charged particles migrate towards the plate can be calculated by balancing the electrical forces with the drag force on the particle moving through the flue gas. The electric field produces a force on the charged particle proportional to the magnitude of the field and the charge: Fe = qE
(24.1)
where Fe = force due to electric field q = charge on particle E = strength of the electric field (volts/cm) However, several simplifying assumptions are needed for calculation of balancing electrical force with drag force: • • • • • •
Repulsion effects between particles of like charge are neglected The effect of the movement of gas ions (electric wind) is neglected Gas flow within the ESP is turbulent Stokes’ Law can be applied for drag resistance in the viscous flow regime Particles have been fully charged by bombardment charging There are no hindered settling effects in the concentrated dust near the plate.
After applying these simplifying assumptions, the migration velocity for particles larger than 1 micron charged by bombardment charging is calculated using Equation 24.2: 3D ε E E d o c p p ω = D+2 C′ 3 µg where D = εo = Ec = Ep = dp = µg = C′ =
(24.2)
dielectric constant for the particle permittivity, 8.854 × 10–12 coulombs/volt-meter strength of the charging electric field strength of precipitating (collecting) electric field particle diameter gas viscosity Cunningham slip correction factor
Note that the migration velocity is proportional to the square of the electrical field strength, directly proportional to the particle diameter, and inversely proportional to the gas viscosity.
© 2002 by CRC Press LLC
9588ch24 frame Page 366 Wednesday, September 5, 2001 10:11 PM
24.2.4 DEUTSCH EQUATION Using the migration velocity to complete a material balance for particles moving toward the ESP plates and particles being carried through the ESP with the gas flow, a common description of particle collection efficiency for monodisperse (same size) particles can be derived: A η = 1 − exp −ω Q where η = ω = A = Q =
(24.3)
fractional collection efficiency migration velocity plate area volumetric gas flow
Any consistent set of units can be used for ω, A, and Q. The expression A/Q is the specific collection area (SCA) of the ESP, commonly expressed as square feet per thousand actual cubic feet per minute (ft2/kacfm). When calculating plate area, remember that the surface area of interior plates includes area exposed to gas flow on both sides of the plate, while the two exterior plates are exposed on only one side. An inherent assumption in the Deutsch Equation is that when particles reach the plates, they are permanently removed from the gas stream. This assumption works reasonably well for low-efficiency ESPs. However, when the collection efficiency is high (greater than 99%), mechanisms other than balancing migration velocity with treatment time dominate the particle emissions. Sneakage, rapping reentrainment, scouring re-entrainment, low-resistivity re-entrainment, and poor gas distribution can become controlling non-ideal effects that limit collection efficiency. For very high efficiency ESPs, empirical modifications of the Deutsch Equation have been used to fit observed data. These include the Hazen Equation: ω A η = 1 − 1 + nQ
−n
(24.4)
where n = empirical constant with typical values of 3 to 5 to fit most data and the Matts–Ohnfeldt Equation: −ω A η = 1 − exp Q where x = empirical constant typically set at 0.5.
© 2002 by CRC Press LLC
x
(24.5)
9588ch24 frame Page 367 Wednesday, September 5, 2001 10:11 PM
A more rigorous approach to calculating ESP efficiency uses a computer model that is based on the Deutsch Equation, but is applied to individual small band widths of the particle size distribution and accounts for the non-ideal effects of sneakage, rapping reentrainment, non-rapping re-entrainment, space charge, and flow distribution. These factors are accounted for by either experience factors or modeling of fundamental mechanisms. Modeling also can account for changes in electrical conditions as particles are collected.1 24.2.4.1 Sneakage Sneakage occurs when gas bypasses the electric field by sneaking under or over the field in the space between the ends of the plates and the ESP enclosure. The high voltage wires and grounded plates must be electrically insulated, and some gas flows above the plates by the insulators and some gas flows through the dust collection hoppers beneath the plates. Proper baffling minimizes sneakage. 24.2.4.2 Rapping Re-Entrainment Another non-ideal effect in a dry ESP is rapping re-entrainment. The dust layer of collected particles on the collection plates is knocked loose periodically by “rapping” or knocking the plates, often with a trip hammer. Most of the dust falls as a sheet into collection hoppers, but some particulate is re-entrained into the gas stream. Factors affecting rapping re-entrainment include the aspect ratio of the ESP (length of the ESP divided by plate height), rapping intensity, dust cohesivity, and dust cake thickness (rapping frequency). With a low aspect ratio, dust has further to fall to reach the hopper before it would exit the ESP. Particles in a cohesive dust cake will tend to stick together as a falling sheet when the plates are rapped. This minimizes re-entrainment. The rapping intensity needs to be strong enough to shear the dust cake from the plate, but not strong enough to produce a cloud. Increasing dust cohesivity with conditioning additives is one of the primary mechanisms for improving fine particle collection. The frequency of rapping should be adjusted to allow a sufficient dust layer to accumulate so that the layer will fall as a cohesive sheet. Experimental studies with fly ash have shown that a re-entrainment cloud forms when the plate loading is below 0.1 g/cm2, while the dust layer develops a more cohesive sheet when rapped at a higher loading. However, if the dust layer becomes too thick, it can act as an insulator and cause a potential gradient to build up within the layer. This reduces the electric field strength in the gas space, and could lead to sparking within the dust layer with subsequent re-entrainment. 24.2.4.3 Particulate Resistivity Once particles reach the dust layer on the collecting electrode, they must stick to the surface until it is cleaned. This is not a problem in a wet ESP because the particle sticks to the wet collection surface until they are washed off by flushing. But in a dry ESP, re-entrainment resulting from dust resistivity that is either too high or too low can reduce the collection efficiency of the ESP. To achieve high collection © 2002 by CRC Press LLC
9588ch24 frame Page 368 Wednesday, September 5, 2001 10:11 PM
FIGURE 24.5 Voltage gradient in dust layer.
efficiency when re-entrainment is a factor, the ESP must be oversized to allow particles to be captured again. The forces that hold particles onto the plate include molecular adhesive forces of the London-van der Waals type and electrostatic forces. The optimum resistivity for good removal in a dry ESP is approximately 1 × 109 to 1 × 1010 ohm-cm. When charged particles arrive at the plate, they are partially discharged. The extent of electrostatic adhesion depends on the rate at which charge leaks away from the particles, which depends on the resistivity of the dust layer. The resistivity of some dusts, including lead smelter fume and coal-fired-boiler fly ash from low-sulfur or alkaline coals, is relatively high. When the resistivity is high, the rate of discharge from the collected particle layer is low. A potential gradient builds up within the layer of collected particles. Figure 24.5 illustrates the potential gradient as voltage vs. distance between the discharge and collection electrodes. Two points on the curve are fixed. The discharge electrode is charged to the maximum voltage for the limits of the power supply. The collection electrodes are grounded. Without a resistive dust layer, the potential gradient will appear as in Figure 24.5a, with the greatest gradient at the discharge electrode where corona is formed. Figure 24.5b illustrates the effect of a highly resistive dust layer. A substantial portion of the voltage drop occurs across the dust layer, leaving a reduced potential gradient across the gas space. With the lower gradient, the driving force for particle migration is reduced. If the dust resistivity is sufficiently high, the steep potential gradient within the dust layer itself can begin to breakdown of the gases between the dust particles. This is “back corona.” Ions of both charges, including the opposite charge from the discharge electrode, are formed and charge particles. These opposite-charge particles are re-entrained as they migrate back toward the discharge electrodes. Sometimes the potential gradient within the dust layer can be severe enough to cause a spark within the dust layer, which violently re-entrains some dust and can limit the maximum voltage that can be maintained by the power supply. © 2002 by CRC Press LLC
9588ch24 frame Page 369 Wednesday, September 5, 2001 10:11 PM
Low-resistivity dust also can result in a re-entrainment problem. The particle charge is lost quickly when the dust has low resistivty. A dust layer of uncharged particles is not held against the collecting plate by the potential gradient from the discharge electrode.2 Carbon dust and moist, low-temperature particles are examples of dusts that have a low resistivity. Two gas properties that have a significant effect on particle resistivity are temperature and humidity. At high temperatures, above about 400°F, volume conduction of electric charge through the particles tends to control resistivity. Such passage obviously depends upon the temperature and composition of the particles. For most materials the relationship between resistivity and temperature is given by an Arrhenius-type equation: −E ρe = A exp kT where ρe = A = E = k = T =
(24.6)
resistivity constant electron activation energy (a negative value) Boltzmann’s constant absolute temperature
Thus, resistivity decreases as temperature increases. At lower temperatures, less than 200°F, surface conduction is the predominant mechanism of charge transfer. Electric charges are carried in a surface film adsorbed on the particulate. The presence of moisture increases surface conduction. Humidification of the flue gas upstream of an ESP both decreases temperature and increases moisture content, which reduces particle resistivity. 24.2.4.4 Gas-Flow Distribution An idealized assumption that is used when applying the Deutsch Equation is that the gas flow and the particulate concentration in the gas are distributed uniformly. Customized flow vanes, baffles, and/or perforated-plate gas distributors often are used at the inlet to produce uniform flow. Sometimes these devices are used at the outlet also. A typical specification for uniform flow distribution requires that 85% of the velocity distribution is within 1.15 times the average velocity, and 99% of the velocity distribution is within 1.40 times the average velocity.3 Two approaches are used to ensure uniform velocity distribution: scale-model studies and Computational Fluid Dynamics (CFD) modeling. CFD modeling is relatively new, but is becoming common as software, computing power, experience, and availability have enabled this tool to be used in a variety of fluid-flow applications. Although uniform gas distribution is generally accepted as the ideal gas flow distribution, computer modeling and a full-scale demonstration at a coal-fired power station in South Africa show that a skewed distribution reduced particulate emissions by more than 50%.4,5 In this patented configuration, the inlet flow distribution is skewed with low flow at the top of the precipitator and higher flow at the bottom. © 2002 by CRC Press LLC
9588ch24 frame Page 370 Wednesday, September 5, 2001 10:11 PM
FIGURE 24.6 Skewed gas flow distribution.
At the outlet, the gas flow is skewed with high flow at the top of the precipitator and low flow at the bottom, as shown in Figure 24.6. This distribution utilizes the fact that collected dust exits the precipitator by falling to the bottom. Dust cake dislodged by rapping is less likely to be re-entrained when the distance that it must fall is short. Thus, particles near the bottom are more likely to be removed than particles near the top of the precipitator. At the inlet, a low velocity gives those particles near the top more treatment time for better collection. At the outlet, particles still near the top have not yet worked their way down the precipitator, so are likely to be emitted anyway, so it is better to maximize the collection efficiency of those particles that have been worked toward the bottom and still can be collected. During operation, flow distribution can be affected by deposits that accumulate on the gas distribution devices. Sometimes, rappers or vibrators are used to remove these deposits.
24.3 PRACTICAL APPLICATION OF THEORY 24.3.1 EFFECTIVE MIGRATION VELOCITY In most cases, it is far more practical and reliable to determine an “effective migration velocity” from operating experience than it is to calculate the migration velocity from Equation 24.2. Then the effect of many unknown properties, including particle size distribution, and simplifying assumptions are buried in the measured performance. The fractional particulate removal efficiency is determined by measuring the inlet and outlet loading in either a pilot-scale, or better a full-scale, ESP. The effective migration velocity, ω, is calculated after rearranging Equation 24.3: ω=−
Q ln (1 − η) A
(24.7)
Having the effective migration velocity enables sizing the required collection area for the desired efficiency under similar conditions, bearing in mind the simplifying assumptions and limitations of the Deutsch Equation discussed previously. © 2002 by CRC Press LLC
9588ch24 frame Page 371 Wednesday, September 5, 2001 10:11 PM
24.3.2 AUTOMATIC VOLTAGE CONTROLLER The potential gradient is the source of corona formation and the driving force for charged particle migration. Equations 24.2 and 24.3 can be used to estimate the effect of increasing voltage for a given application. The automatic voltage controller (AVC) increases the secondary (i.e., DC) voltage that is applied to an ESP field until either: • The spark rate limit is reached; or • The current limit of the power supply is reached A spark is an electrical breakdown of the gas space. Modern electronics are able to detect an incipient spark and immediately reduce the voltage to quench the spark, after which the voltage is slowly increased again.
24.4 FLUE GAS CONDITIONING Flue gas conditioning has been successfully used to lower fly ash resistivity in coldside ESP for a number of years and, more recently, has been demonstrated effective in hot-side precipitator applications as well. There are several mechanisms by which conditioning may affect ESP performance including: • Reducing back corona and increasing potential gradient in the gas space by lowering fly ash resistivity. • Reducing re-entrainment by increasing the cohesive properties of fly ash. • Increasing agglomeration or growth of small particles to form larger particles. • Increasing space charge to produce a more uniform potential gradient in the interelectrode space, thereby allowing operation at higher voltages. In cold-side ESP applications, conditioning agents that have been effective include: • • • • • •
Water vapor Sulfuric acid or SO3 Ammonia Ammonium sulfate Triethylamine Proprietary additives (e.g., ADA-23)
24.4.1 HUMIDIFICATION Cooling a hot flue gas stream by evaporating a spray of fine water droplets produces a net decrease in the gas volumetric flow rate, increases the gas density, increases the moisture content of the gas stream, and reduces the particulate resistivity. Increasing both the gas density and the moisture content, increases the spark-over voltage at which the gas breaks down. Therefore, higher field strength can be achieved before spark rate limits further voltage increases. © 2002 by CRC Press LLC
9588ch24 frame Page 372 Wednesday, September 5, 2001 10:11 PM
A key concern with spraying water droplets is that the water droplets are completely evaporated before they impact the interior surfaces in ductwork. If water wets the walls of the ductwork, particulate may stick and accumulate and corrosion may be accelerated rapidly. Generally, at least 1 s residence time for drying in a straight section of duct is desired for a fine spray with a Sauter mean diameter of 50 microns.6 Dual-fluid atomizing nozzles are typically used to achieve the fine spray, because high-pressure hydraulic nozzles would require 500 to 5000 psi with very small orifices that are prone to plugging and wear.
24.4.2 SO3 Addition of sulfuric acid or SO3 is a common method of lowering particulate resistivity. Sulfamic acid has been used as a source of SO3 as it decomposes at flue gas temperatures upstream of the air heater. The conditioning effect is attributed to the formation of sulfuric acid as SO3 combines with water and condenses on the particulate surfaces, and/or to the direct adsorption of SO3 on the surface of the particles with the subsequent formation of sulfates which act as electrolytes and enhance surface conduction. Because the mechanism of SO3 conditioning relies on condensation of H2SO4, the method is not effective at temperatures above 375°F. Therefore, it is not used for “hot-side” ESPs, which are located upstream of the air heater in a power boiler. Also, neutralization of acid by basic components such as calcium oxide in the fly ash may produce insoluble sulfate salts having a high resistivity. Thus, fly ash alkalinity is another factor in determining the effectiveness of SO3 conditioning.
24.4.3 AMMONIA Addition of ammonia or ammonia compounds is another method of conditioning that has been used to improve ESP performance, particularly in the petroleum refining industry on fluid catalytic cracking (FCC) units. Catalyst dust from FCC units typically has a high resistivity. Several hypotheses for the mechanism for improved ESP performance by NH3 conditioning have been proposed. Explanations include neutralization of sulfuric acid in the case of low-resistivity fly ash;7 reduction of back corona as characteristics of the gas are changed;8 and higher voltage operation due to an enhanced potential gradient resulting from space charge effects.9,10 The presence of very fine ammonium sulfate particles produced by the reaction of ammonia and SO3 increases space charge, which would decrease the electric field strength near the corona discharge and allow a steeper gradient near the collecting plate. Although excessive space charge can lead to corona quenching, moderate space charge produces a higher driving force for particle migration outside of the corona discharge region. The space charge effect can be beneficial when the enhancement in the collecting electric field more than compensates for the decreased corona discharge. Another explanation is that ammonia reacts with sulfuric acid mist in the flue gas, forming ammonium bisulfate, NH4HSO4, and ammonium sulfate, (NH4)2SO4. Ammonium bisulfate is deliquescent (absorbs water readily, then dissolves in the absorbed water) and has
© 2002 by CRC Press LLC
9588ch24 frame Page 373 Wednesday, September 5, 2001 10:11 PM
a melting point of 296.4°F.10 Therefore, it would form a cohesive, sticky material in the ESP. Recent work with FCC units indicates that ammonia increases the breakdown strength of the gas space between particles in the dust layer. Sparking within the dust layer occurs when the electric field in the dust layer exceeds the breakdown strength of the gas in the interparticle spaces. Since the dust layer in FCC unit applications has a high resistivity, the potential gradient within the dust layer is high. It has been demonstrated that ammonia conditions the gas rather than the dust as evidenced by the lack of residual ammonia in collected dust and a rapid response to changes in concentration.11 Unfortunately, ammonia conditioning generates emissions of unreacted ammonia. This disadvantage has become more apparent in recent years with public attention focused by the Toxic Release Inventory reporting requirements and the emphasis to reduce hazardous air pollutants.
24.4.4 SO3
AND
AMMONIA
The addition of both SO3 and ammonia would provide ESP performance enhancements by most of the mechanisms discussed above for ammonia alone, but allows control over the amount of each additive and their ratio. The normal flue gas SO3 concentration produced by coals with the same sulfur content may vary considerably due to basic components in the coal such as calcium oxide, and to trace metal catalysts such as vanadium which would convert SO2 to SO3.
24.4.5 AMMONIUM SULFATE The addition of ammonium sulfate rather than ammonia and SO3 gases separately also can improve ESP performance. In this case, the primary mechanism was attributed to adsorption of SO3 on the fly ash after ammonium sulfate decomposed to SO3 and NH3. Supplemental benefits may have resulted from the coprecipitation of undecomposed ammonium sulfate particles with the fly ash, although there was no indication of agglomeration or particle growth or generation of fine fume to enhance space charge, and rapping emission reductions were attributed to improved collection in the inlet fields rather than to increased cohesion.12
24.4.6 PROPRIETARY ADDITIVES A new approach to flue gas conditioning is the use of proprietary phosphaste-based additive solutions that have been developed and commercialized to overcome dust resistivity issues. They have demonstrated dramatic reductions in resistivity of a lignite flyash over a wide temperature range in a full-scale coal-fired application. Resistivity was reduced by as much as four orders of magnitude at 380°F, and as much as two orders of magnitude at 700°F.13 Opacity from the stack of a coal-fired boiler with a cold-side (downstream of the air heater) ESP was reduced from 15% to less than 5%.14 Advantages to this method of conditioning include low capital cost for equipment to inject the additive solution, and that the chemicals are relatively
© 2002 by CRC Press LLC
9588ch24 frame Page 374 Wednesday, September 5, 2001 10:11 PM
nontoxic compared to traditional conditioning agents SO3 (which forms H2SO4) and ammonia.
24.5 USING V-I CURVES FOR TROUBLESHOOTING Much troubleshooting of ESP problems can be accomplished by evaluating the electrical characteristics of the ESP. A powerful troubleshooting tool is the V-I curve, which is simply a plot of the secondary current that is produced as the secondary voltage is increased. To generate a V-I curve, the voltage on one bus section is reduced to zero, then manually increased in about 10% increments. Record the secondary voltage and current, and continue stepping up the voltage until 100% capacity is reached. The entire procedure takes only a few minutes, but the section will be operating at less than full power during this time. The secondary current is plotted on rectangular coordinates as a function of secondary voltage. Example V-I curves are shown in Figure 24.7. Curve 1 is typical of normal operation. As the voltage is increased from zero, there is no current. At some voltage, current flow will begin. This occurs at the onset of corona discharge. Current increases with increasing voltage until the current limit of the power supply is reached. Curves 2 through 7 in Figure 24.7 indicate problems. Curve 2 shows current flow commencing immediately as the voltage is increased, and current increasing with a steep slope until the current limit is reached. This is symptomatic of a direct short to ground, which may be due to a cracked insulator or bridging of dust between the electrodes. Curve 3 shows corona forming at a low voltage, then voltage and current increasing until sparking occurs at a relatively low voltage. Remember that corona
FIGURE 24.7 V-I curves.
© 2002 by CRC Press LLC
9588ch24 frame Page 375 Wednesday, September 5, 2001 10:11 PM
is induced by a steep potential gradient. Early onset of corona is due to an unusually steep gradient, which occurs when the physical spacing between the electrodes is reduced. Also, gas breakdown or sparking occurs when the gap between the electrodes is low. Thus, curve 3 represents a severe misalignment between the emitting electrodes and the collecting plates. Curve 4 shows normal corona formation, but an unusual current increase that actually can have a backward curve. This unusual shape results from back-corona that forms in the dust layer in addition to the corona formed at the emitting electrodes. Back-corona is formed in high-resistivity dust by the steep potential gradient within the dust layer. Curve 5 is similar to curve 4, but ends with a spark in the dust layer. Curve 6 is a result of corona not forming until the voltage is very high, then a spark may occur with a small increase in voltage. A likely cause is deposits buildup on the emitting electrodes, which can blunt the sharp edges of the emitting electrode. Since corona forms at the high potential gradient at sharp edges, corona formation is suppressed. Curve 7 shows normal onset of corona, but the current does not increase with increasing voltage. In this case, severe space charge by charged submicron particles in the gas space flattens the potential gradient sufficiently to suppress additional corona formation. Air load V-I curves on a new unit can ensure that the unit is installed and aligned correctly. Baseline V-I curves with flue gas at operating temperature will be different than air-load curves. These baseline curves will be helpful in monitoring changes in the curves as the precipitator ages. At higher temperatures, the flue gas is less dense and will break down at lower voltages. However, high flue gas moisture content increases the breakdown voltage of the gas, in addition to affecting the dust resistivity.
REFERENCES 1. McDonald, J. R., Computer simulation of the electrostatic precipitation process, in Proc. Int. Conf. Electrostatic Precipitation, Air Pollution Control Assoc., Pittsburgh, October 1981. 2. Katz, J., Factors affecting resistivity in electrostatic precipitation, J. Air Poll. Contr. Assoc., 30(1), 165, 1980. 3. Gas Flow Model Studies, Industrial Gas Cleaning Institute, Pub. No. E-P7, Rev I, Washington, D.C., 1969. 4. Hein, A. G., Dust reentrainment, gas distribution and electrostatic precipitator performance, J. Air Poll. Contr. Assoc., 39(5), 766, 1989. 5. The McIlvaine Company, Skewed gas flow technology demonstrated in South Africa, Precip. Newsletter, 241, 1996. 6. Butz, J. R., Baldrey, K. E., and Sam, D. O., Computer modeling of ESP performance improvement due to spray cooling, presented at EPRI/DOE Int. Conf. on Managing Hazardous and Particulate Air Pollutants, Toronto, August 15–18, 1995. 7. Reese, J. T. and Greco, J., Electrostatic precipitation, Mech. Eng., 90(10), 13-7, 1968. 8. Watson, K. S. and Blecher, K. J., Investigation of electrostatic precipitators for large P.F. fired boilers, presented at Clean Air Conference, Sydney, Australia, 1965.
© 2002 by CRC Press LLC
9588ch24 frame Page 376 Wednesday, September 5, 2001 10:11 PM
9. Dismukes, E. B., Conditioning of Fly Ash with Sulfur Trioxide and Ammonia, Environmental Protection Agency, EPA-600/2-75-015, TVA-F75 PRS-5, 1975. 10. Krigmont, H. V. and Coe, Jr., E. L., Experience with dual flue gas conditioning of electrostatic precipitators, presented at Eighth Symp. on Transfer and Utilization of Particulate Control Technology, San Diego, March 20–23, 1990. 11. Durham, M. D., personal communication, 2000. 12. Gooch, J. P., Bickelhaupt, R. E., and Dismukes, E. B., Investigation of Ammonium Sulfate Conditioning for Cold-Side Electrostatic Precipitators — Volume 1: Field and Laboratory Studies, Electric Power Research Institute, EPRI CS-3354, 1, 1984. 13. Durham, M. D., Bustard, C. J., and Martin, C. E., New ESP additive controls particulates, Power Eng., 101(06), 44, 1997. 14. Durham, M. D. et al., Full-scale experience with ADA-34 2nd generation flue gas conditioning for hot-side and cold-side ESPs, in EPRI-DOE-EPA Combined Utility Air Pollution Control Symp. The MEGA Symp., EPRI, 1999.
© 2002 by CRC Press LLC